Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SU-G-IeP2-09: Iodine Imaging at Spectral CT with a Dual-Layer Detector

Purpose: To evaluate the attenuation response of iodine and the accuracy of iodine quantification on a detector-based spectral CT scanner. Methods: A Gammex 461A phantom was scanned using a dual-layer detector (IQon, Philips) at 120 kVp using helical acquisition with a CDTIvol of 15 mGy to approximate the hospital’s clinical body protocol. No modifications to the standard protocol were necessary to enable spectral imaging. Iodine inserts at 6 concentrations (2, 5, 7.5, 10, 15, 20 mg/ml) were scanned individually at the center of the phantom and the 20 mg/ml insert was additionally scanned at the 3, 6, and 12 o’clock positions. Scans were repeated 10 times. Conventional, virtual monoenergetic (40–200 keV) and iodine-no-water images (with pixel values equal to iodine concentration of corresponding tissue) were reconstructed from acquired data. A circular ROI (diameter=30 pixels) was used in each conventional and monoenergetic image to measure the mean and standard deviation of the CT number in HU and in each iodine-no-water image to measure iodine concentration in mg/ml. Results: Mean CT number and contrast-to-noise ratio (CNR) measured from monoenergetic images increased with decreasing keV for all iodine concentrations and matched measurements from conventional images at 75 keV. Measurements from the 20 ml insert showed the CT number is independent of location and CNR is a function only of noise, which was higher in the center. Measured concentration from iodine-no-water images matched phantom manufacturer suggested concentration to within 6% on average for inserts at the center of the phantom. Measured concentrations were systematically higher due to optimization of iodine quantification parameters for clinical mixtures of iodine and blood/tissue. Conclusion: Spectral acquisition and reconstruction with a dual-layer detector represents the physical behavior of iodine as expected and accurately quantifies the material concentration. This should permit a variety of clinical applications including lesion characterization, vessel patency, and myocardial perfusion. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

Protecting qubit coherence by spectrally engineered driving of the spin environment

Abstract Modern quantum technologies rely crucially on techniques to mitigate quantum decoherence; these techniques can be either passive, achieved for example via materials engineering, or active, typically achieved via pulsed monochromatic driving fields applied to the qubit. Using a solid-state defect spin coupled to a microwave-driven spin bath, we experimentally demonstrate a decoherence mitigation method based on spectral engineering of the environmental noise with a polychromatic drive waveform, and show that it outperforms monochromatic techniques. Results are in agreement with quantitative modeling, and open the path to active decoherence protection using custom-designed waveforms applied to the environment rather than the qubit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of Simulations of Double-detonation Type Ia Supernovae to Integration Methodology

Abstract We study the coupling of hydrodynamics and reactions in simulations of the double-detonation model for Type Ia supernovae. When assessing the convergence of simulations, the focus is usually on spatial resolution; however, the method of coupling the physics together as well as the tolerances used in integrating a reaction network also play an important role. In this paper, we explore how the choices made in both coupling and integrating the reaction portion of a simulation (operator/Strang splitting versus the simplified spectral deferred corrections method we introduced previously) influences the accuracy, efficiency, and nucleosynthesis of simulations of double detonations. We find no need to limit reaction rates or reduce the simulation time step to the reaction timescale. The entire simulation methodology used here is GPU-accelerated and made freely available as part of the Castro simulation code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complete particle-pair annihilation as a dynamical signature of the spectral singularity

Motivated by the physical relevance of a spectral singularity of interacting many-particle system, we explore the dynamics of two bosons as well as fermions in one-dimensional system with imaginary delta interaction strength. Based on the exact solution, it shows that the two-particle collision leads to amplitude-reduction of the wave function. For fermion pair, the amplitude-reduction depends on the spin configuration of two particles. In both cases, the residual amplitude can vanish when the relative group velocity of two single-particle Gaussian wave packets with equal width reaches the magnitude of the interaction strength, exhibiting complete particle-pair annihilation at the spectral singularity. - Highlights: • We investigate the physical relevance of a spectral singularity. • The two-particle collision leads to amplitude-reduction of the wave function. • There is a singularity spectrum which leads to complete particle-pair annihilation. • Complete particle-pair annihilation can only occur for two distinguishable bosons and singlet fermions. • Pair annihilation provides a detection method of the spectral singularity in the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may be used to reliably measure the neutron spectrum of a radiotherapy beam in less than 1 h, including setup and data unfolding. This work thus represents a new, fast, and practical method for neutron spectral measurements in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Variational AutoEncoders Reveal Intensifying GPP Extremes in Continental United States based on CESM2 Simulations

Climate extremes significantly impact terrestrial carbon cycle dynamics, necessitating robust methods for detecting and analyzing anomalous behavior in plant productivity. This study presents a novel application of variational autoencoders (VAE) for identifying extreme events in gross primary productivity (GPP) from Community Earth System Model version 2 simulations across four AR6 regions in the Continental United States. We compare VAE-based anomaly detection with traditional singular spectral analysis (SSA) methods across three time periods: 1850-80, 1950-80, and 2050-80 under SSP5-8.5 scenario. The VAE architecture employs three dense layers and a latent space with input sequence length of 12 months, training on normalized GPP time series to reconstruct the GPP and identify anomalies based on reconstruction errors. Extreme events are defined using 5th percentile thresholds applied to both VAE and SSA anomalies. Results demonstrate strong regional agreement between VAE and SSA methods in spatial patterns of extreme event frequencies, despite VAE consistently producing higher threshold values (179-756 GgC for VAE vs. 100-784 GgC for SSA across regions and periods). Both methods reveal increasing magnitudes and frequencies of negative carbon cycle extremes toward 2050-80, particularly in Western and Central North America. The VAE approach shows comparable performance to established SSA techniques while offering computational advantages and enhanced capability for capturing non-linear temporal dependencies in carbon cycle variability. This research demonstrates the potential of deep learning approaches for extremes detection and provides a foundation for improved understanding of future carbon cycle risks under future conditions.

Sharma, Bharat [ORNL] (ORCID:0000000266982487)↗

Graph Metric Learning Quantifies Morphological Differences between Two Genotypes of Shoot Apical Meristem Cells in Arabidopsis

We present a method for learning “spectrally descriptive” edge weights for graphs. We generalize a previously known distance measure on graphs (Graph Diffusion Distance), thereby allowing it to be tuned to minimize an arbitrary loss function. Because all steps involved in calculating this modified GDD are differentiable, we demonstrate that it is possible for a small neural network model to learn edge weights which minimize loss. We apply this method to discriminate between graphs constructed from shoot apical meristem images of two genotypes of Arabidopsis thaliana specimens: wild-type and trm678 triple mutants with cell division phenotype. Training edge weights and kernel parameters with contrastive loss produces a learned distance metric with large margins between these graph categories. We demonstrate this by showing improved performance of a simple k-nearest-neighbors classifier on the learned distance matrix. We also demonstrate a further application of this method to biological image analysis. Once trained, we use our model to compute the distance between the biological graphs and a set of graphs output by a cell division simulator. Comparing simulated cell division graphs to biological ones allows us to identify simulation parameter regimes which characterize mutant vs. wild-type Arabidopsis cells. We find that trm678 mutant cells are characterized by increased randomness of division planes and decreased ability to avoid previous vertices between cell walls.

59 BASIC BIOLOGICAL SCIENCES↗

Photon production rate from Transverse-Longitudinal ( T – L) mesonic correlator on the lattice

Thermal photons from the QGP provide important information about the interaction among plasma constituents. The photon production rate from a thermally equilibrated system is proportional to the transverse spectral function ρ T (ω = |k → |,k → ). One can also calculate the photon production rate from the difference between ρ T (ω, k → ) (transverse) and ρ L (ω, k → ) (longitudinal) projections, as ρL vanishes on the photon point. Because the UV part of ρ T – ρ L is suppressed, the corresponding Euclidean correlator receives most of its contribution from the IR part. We calculate the T – L correlator on N f = 2 + 1 flavour HISQ configurations with m l = m s /5 at temperature of about 1.15T ρc (220 MeV). We have used two ansätze for the spectral function: 1) A polynomial connected to the UV region consistent with OPE expansion and 2) a hydro-inspired spectral function. We have also applied the Backus-Gilbert method to estimate the spectral function. All these different approaches are combined to estimate the photon production rate.

Bala, Dibyendu↗

Restricted active space calculations of L-edge X-ray absorption spectra: From molecular orbitals to multiplet states

The metal L-edge (2p → 3d) X-ray absorption spectra are affected by a number of different interactions: electron-electron repulsion, spin-orbit coupling, and charge transfer between metal and ligands, which makes the simulation of spectra challenging. The core restricted active space (RAS) method is an accurate and flexible approach that can be used to calculate X-ray spectra of a wide range of medium-sized systems without any symmetry constraints. Here, the applicability of the method is tested in detail by simulating three ferric (3d{sup 5}) model systems with well-known electronic structure, viz., atomic Fe{sup 3+}, high-spin [FeCl{sub 6}]{sup 3−} with ligand donor bonding, and low-spin [Fe(CN){sub 6}]{sup 3−} that also has metal backbonding. For these systems, the performance of the core RAS method, which does not require any system-dependent parameters, is comparable to that of the commonly used semi-empirical charge-transfer multiplet model. It handles orbitally degenerate ground states, accurately describes metal-ligand interactions, and includes both single and multiple excitations. The results are sensitive to the choice of orbitals in the active space and this sensitivity can be used to assign spectral features. A method has also been developed to analyze the calculated X-ray spectra using a chemically intuitive molecular orbital picture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and localization of rotational spectra using recurrent neural networks

A method of identifying molecular parameters in a complex mixture may include receiving a set of combined transition frequencies and analyzing the set of combined transition frequencies using a first trained artificial neural network to generate a plurality of separated transition frequency sets. Each of the plurality of separated frequency sets may be analyzed using a second trained artificial neural network to generate a respective set of estimated spectral parameters. The method may include identifying a set of molecular parameters corresponding to the set of separated transition frequencies.

Prozuments, Kirills↗

Measuring the 3D clustering of undetected galaxies through cross correlation of their cumulative flux fluctuations from multiple spectral lines

We discuss a method for detecting the emission from high redshift galaxies by cross correlating flux fluctuations from multiple spectral lines. If one can fit and subtract away the continuum emission with a smooth function of frequency, the remaining signal contains fluctuations of flux with frequency and angle from line emitting galaxies. Over a particular small range of observed frequencies, these fluctuations will originate from sources corresponding to a series of different redshifts, one for each emission line. It is possible to statistically isolate the fluctuations at a particular redshift by cross correlating emission originating from the same redshift, but in different emission lines. This technique will allow detection of clustering fluctuations from the faintest galaxies which individually cannot be detected, but which contribute substantially to the total signal due to their large numbers. We describe these fluctuations quantitatively through the line cross power spectrum. As an example of a particular application of this technique, we calculate the signal-to-noise ratio for a measurement of the cross power spectrum of the OI(63 μm) and OIII(52 μm) fine structure lines with the proposed Space Infrared Telescope for Cosmology and Astrophysics (SPICA). We find that the cross power spectrum can be measured beyond a redshift of z = 8. Such observations could constrain the evolution of the metallicity, bias, and duty cycle of faint galaxies at high redshifts and may also be sensitive to the reionization history through its effect on the minimum mass of galaxies. As another example of this technique, we calculate the signal-to-noise ratio for the cross power spectrum of CO line emission measured with a large ground based telescope like the Cornell Caltech Atacama Telescope (CCAT) and 21-cm radiation originating from hydrogen in galaxies after reionization with an interferometer similar in scale to the Murchison Widefield Array (MWA), but optimized for post-reionization redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

The spectral irradiance traceability chain at PTB

Spectral irradiance is a fundamental radiometric unit. Its application to measurement results requires qualified traceability to basic units of the international system of units (Systeme international d'unites, SI). The Physikalisch-Technische Bundesanstalt (PTB) is amongst other national metrological institutes (NMIs) responsible for the realization, maintenance and dissemination of various radiometric and photometric units based on and traceable to national standards. The unit of spectral irradiance is realized and represented by a blackbody-radiator as the national primary standard of the PTB. Based on Planck's radiation law, the irradiance is calculated and realized for any wavelength taking into account the exact knowledge of the radiation temperature and the geometrical parameters. Using a double-monochromator-based spectroradiometer system, secondary standard lamps can be calibrated by direct comparison to the blackbody-radiator (substitution method). These secondary standard lamps are then used at the PTB to calibrate standard lamps of customers. The customers themselves use these so-called transfer standards to calibrate their working standard lamps. These working standards are then used to calibrate own spectroradiometers or sources. This rather complex calibration chain is a common procedural method that for the customers generally leads to satisfying measurement results on site. Nevertheless, the standard lamps in use have to fulfill highest requirements concerning stability and reproducibility. Only this allows achieving comparably low transfer measurement uncertainties, which occur at each calibration step. Thus, the PTB is constantly investigating the improvement and further development of transfer standards and measurement methods for various spectral regions. The realization and dissemination of the spectral irradiance using the blackbody-radiator at the PTB is accomplished with worldwide approved minimized measurement uncertainties confirmed by international intercomparisons among NMIs. Ultimately, the spectral irradiance can be realized with expanded measurement uncertainties of far less than 1 % over a wide spectral range. Thus, for customers with high demands on low measurement uncertainties, it is possible to calibrate their working standards directly against the blackbody-radiator, taking into account the higher necessary effort. In special cases it is possible to calibrate the customer's spectroradiometric facilities directly in front of the blackbody-radiator. In the context of the European Metrology Research Project Traceability for surface spectral solar ultraviolet radiation, the traceability chain will be improved and adapted.

58 GEOSCIENCES↗

Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factorization-based texture segmentation

This study introduces a factorization-based approach that efficiently segments textured images. We use local spectral histograms as features, and construct an M × N feature matrix using M-dimensional feature vectors in an N-pixel image. Based on the observation that each feature can be approximated by a linear combination of several representative features, we factor the feature matrix into two matrices-one consisting of the representative features and the other containing the weights of representative features at each pixel used for linear combination. The factorization method is based on singular value decomposition and nonnegative matrix factorization. The method uses local spectral histograms to discriminate region appearances in a computationally efficient way and at the same time accurately localizes region boundaries. Finally, the experiments conducted on public segmentation data sets show the promise of this simple yet powerful approach.

97 MATHEMATICS AND COMPUTING↗