Use of Sensors and Machine Learning for Signal Discovery in a Solvent Extraction Process – 23280

Reprocessing is an important step in the nuclear fuel cycle where usable nuclear materials are extracted from spent fuel for recycling. The extraction of materials for reuse simultaneously reduces not only the volume of nuclear waste, but its decay time to radioactivity levels similar to that of the originating uranium ore. As part of an initiative to steward research, development, and innovation into the nuclear fuel cycle, Idaho National Laboratory is designing and constructing a solvent extraction testbed named Beartooth. Beartooth will allow researchers to refine extraction processes, test innovative extraction processes, and give early career scientists opportunities to gain skills in performing separations chemistry that uses centrifugal contactors. In addition, the Beartooth testbed is being uniquely designed to enable novel technologies including machine learning capabilities for the characterization of chemical process operations in near real-time. To aid in the design of Beartooth, a team of researchers are installing a variety of atypical sensors into a system of contactors for signal discovery. The team will implement machine learning methods on sensor data to determine signal features with the goal of providing a process operator with a deeper understanding of the chemical process and equipment usage. This work will summarize sensors utilized and preliminary results from an infrared camera.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling the Pseudomonas Sulfur Regulome by Quantifying the Storage and Communication of Information

ABSTRACT Bacteria are not simply passive consumers of nutrients or merely steady-state systems. Rather, bacteria are active participants in their environments, collecting information from their surroundings and processing and using that information to adapt their behavior and optimize survival. The bacterial regulome is the set of physical interactions that link environmental information to the expression of genes by way of networks of sensors, transporters, signal cascades, and transcription factors. As bacteria cannot have one dedicated sensor and regulatory response system for every possible condition that they may encounter, the sensor systems must respond to a variety of overlapping stimuli and collate multiple forms of information to make “decisions” about the most appropriate response to a specific set of environmental conditions. Here, we analyze Pseudomonas fluorescens transcriptional responses to multiple sulfur nutrient sources to generate a predictive, computational model of the sulfur regulome. To model the regulome, we utilize a transmitter-channel-receiver scheme of information transfer and utilize principles from information theory to portray P. fluorescens as an informatics system. This approach enables us to exploit the well-established metrics associated with information theory to model the sulfur regulome. Our computational modeling analysis results in the accurate prediction of gene expression patterns in response to the specific sulfur nutrient environments and provides insights into the molecular mechanisms of Pseudomonas sensory capabilities and gene regulatory networks. In addition, modeling the bacterial regulome using the tools of information theory is a powerful and generalizable approach that will have multiple future applications to other bacterial regulomes. IMPORTANCE Bacteria sense and respond to their environments using a sophisticated array of sensors and regulatory networks to optimize their fitness and survival in a constantly changing environment. Understanding how these regulatory and sensory networks work will provide the capacity to predict bacterial behaviors and, potentially, to manipulate their interactions with an environment or host. Leveraging the information theory provides useful quantitative metrics for modeling the information processing capacity of bacterial regulatory networks. As our model accurately predicted gene expression profiles in a bacterial model system, we posit that the information theory-based approaches will be important to enhance our understanding of a wide variety of bacterial regulomes and our ability to engineer bacterial sensory and regulatory networks.

Larsen, Peter E.↗

Self-powered ocean buoy using a disk-type triboelectric nanogenerator with a mechanical frequency regulator

Triboelectric nanogenerator (TENG) systems have been demonstrated to generate power with high density. However, the electrical output power obtained from wave energy harvesting using TENG systems is typically limited to several milliwatts. To address this limitation and support various ocean buoy systems, an efficient method to scale-up TENG systems is required. In this paper, we present a self-powered ocean buoy (SPOB) incorporating a disk-type, soft-contact, mechanical frequency regulator TENG (DSMFR-TENG). The mechanical frequency regulator (MFR) enables the conversion of low-frequency wave energy to high-speed mechanical rotation, facilitating high power generation with the disk-type TENG. Here, the SPOB was tested in a wave tank, reaching a peak power output of 470 mW and an average power output of 130 mW after the MFR released the rotational energy. To further enhance the functionality of the buoy, the DSMFR-TENG and a microcontroller, temperature sensor, and acoustic transmitter were integrated with the SPOB. The acoustic transmitter successfully transmitted signals 7, 23, and 30 times over a one-minute period at wave frequencies of 0.33 Hz, 0.5 Hz, and 1 Hz, respectively, thereby demonstrating the power supply capability of the TENG system for ocean buoys.

42 ENGINEERING↗

Methods to prepare stable electrolytes for iron redox flow batteries

An iron redox flow battery system, comprising a redox electrode, a plating electrolyte tank, a plating electrode, a redox electrolyte tank with additional acid additives that may be introduced into the electrolytes in response to electrolyte pH. The acid additives may act to suppress undesired chemical reactions that create losses within the battery and may be added in response to sensor indications of these reactions.

25 ENERGY STORAGE↗

Methods to prepare stable electrolytes for iron redox flow batteries

An iron redox flow battery system, comprising a redox electrode, a plating electrolyte tank, a plating electrode, a redox electrolyte tank with additional acid additives that may be introduced into the electrolytes in response to electrolyte pH. The acid additives may act to suppress undesired chemical reactions that create losses within the battery and may be added in response to sensor indications of these reactions.

25 ENERGY STORAGE↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The effect of non-uniform temperature and velocity fields on long range ultrasonic measurement systems in MYRRHA

SCK.CEN, the Belgian Nuclear Research Center, is developing MYRRHA, a generation IV liquid metal cooled nuclear research reactor. As the liquid metal coolant is opaque to light, normal visual feedback during fuel manipulations is not available and must therefore be replaced by a system that is not hindered by the opacity of the coolant. In this respect ultrasonic based instrumentation is under development at SCK.CEN to provide feedback during operations under liquid metal. One of the tasks that will be tackled using ultrasound is the detection and localization of a potentially lost fuel assembly. In this application, the distance between ultrasonic sensor and target may be as large as 2.5 m. At these distances, non uniform velocity and temperature fields in the liquid metal potentially influence the propagation of the ultrasonic signals, affecting the performance of the ultrasonic systems. In this paper, we investigate how relevant temperature and velocity gradients inside the liquid metal influence the propagation of ultrasonic waves. The effect of temperature and velocity gradients are simulated by means of a newly developed numerical ray-tracing model. The performance of the model is validated by dedicated water experiments. The setup is capable of creating velocity and temperature gradients representative for MYRRHA conditions. Once validated in water, the same model is used to make predictions for the effect of gradients in the MYRRHA liquid metal environment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method for measuring thermal accommodation coefficients of gases on thin film surfaces using a MEMS sensor structure

A method for measuring the thermal accommodation coefficient α for surface-/gas interfaces is presented. It allows the determination of α for thin films produced by a variety of deposition technologies, such as chemical vapor deposition, physical vapor deposition, and atomic layer deposition (ALD). The setup is based on two microelectromechanical systems (MEMS) Pirani sensors facing each other in a defined positioning. Because these MEMS sensors show a very high sensitivity in their individual molecular flow regimes, it is possible to measure the accommodation coefficients of gases without the disturbing influence of the transition regime. This paper presents the analytical background and the actual measurement principle. The results for air and nitrogen molecules on sputtered Au and Pt surfaces are presented.

42 ENGINEERING↗

High-Accuracy and High-Stability Fiber-Optic Temperature Sensors for Coal Fired Advanced Energy

A research team at Michigan State University, led by Dr. Ming Han, has developed a revolutionary fiber-optic thermometer for use in next-generation coal-fired power plants. Funded by the U.S. Department of Energy, this new sensor is designed to measure extremely high temperatures with unmatched accuracy and long-term stability. Unlike conventional optical sensors that can give false readings due to mechanical strain and often drift out of calibration at high heat, this new technology uses a sealed gas chamber as its core. By measuring the temperature-dependent properties of the gas (air or argon), the sensor’s readings remain absolute and reliable, completely unaffected by the physical stresses on the surrounding equipment. The breakthrough design eliminates the need for complex and costly correction systems. It represents a fundamental shift in sensing technology, paving the way for a primary thermometer that maintains calibration and provides foundational accuracy essential for advanced energy systems.

01 COAL, LIGNITE, AND PEAT↗

Radiometric and geometric analysis of hyperspectral imagery acquired from an unmanned aerial vehicle

During the summer of 2010, an Unmanned Aerial Vehicle (UAV) hyperspectral in-flight calibration and characterization experiment of the Resonon PIKA II imaging spectrometer was conducted at the U.S. Department of Energy’s Idaho National Laboratory (INL) UAV Research Park. The purpose of the experiment was to validate the radiometric calibration of the spectrometer and determine the georegistration accuracy achievable from the on-board global positioning system (GPS) and inertial navigation sensors (INS) under operational conditions. In order for low-cost hyperspectral systems to compete with larger systems flown on manned aircraft, they must be able to collect data suitable for quantitative scientific analysis. The results of the in-flight calibration experiment indicate an absolute average agreement of 96.3%, 93.7% and 85.7% for calibration tarps of 56%, 24%, and 2.5% reflectivity, respectively. The achieved planimetric accuracy was 4.6 meters (based on RMSE).

42 ENGINEERING↗

Sensor systems for the Altair Lunar Lander:

The Altair Lunar Lander will enable astronauts to learn to live and work on the moon for extended periods of time, providing the experience needed to expand human exploration farther into the solar system. My overriding recommendation: Use independent and complementary [sometimes referred to as 'orthogonal'] techniques to disambiguate confounding/interfering signals. E.g.: a mass spectrometer ['MS'], which currently serves as a Majority Constituent Analyzer ['MCA'] can be very valuable in detecting the presence of a gaseous specie, so long as it falls on a mass-to-charge ratio ['m/z'] that is not already occupied by a majority constituent of cabin air. Consider the toxic gas, CO. Both N{sub 2} and CO have parent peaks of m/z = 28, and CO{sub 2} has a fragment peak at m/z = 28 [and at 16 and 12], so the N{sub 2} and CO{sub 2} m/z=28 signals could mask low, but potentially-dangerous levels of CO. However there are numerous surface-sensitive CO detectors, as well as tunable-diode-laser-based CO sensors that could provide independent monitoring of CO. Also, by appending a gas chromatograph ['GC'] as the front-end sample processer, prior to the inlet of the MS, one can rely upon the GC to separate CO from N{sub 2} and CO{sub 2}, providing the crew with another CO monitor. If the Altair Lunar Lander is able to include a Raman-based MCA for N{sub 2}, O{sub 2}, H{sub 2}O, and CO{sub 2}, then each type of MCA would have cross-references, providing more confidence in the ongoing performance of each technique, and decreasing the risk that one instrument might fail to perform properly, without being noticed. See, also Dr. Pete Snyder's work, which states 'An orthogonal technologies sensor system appears to be attractive for a high confidence detection of presence and temporal characterization of bioaerosols.' Another recommendation: Use data fusion for event detection to decrease uncertainty: tie together the outputs from multiple sensing modalities - eNose, solid-state sensors, GC-IMS, GC-MS - via nonlinear algorithms, such as an 'artificial neural net.' MA Ryan at the JPL and Henry Abarbanel at UCSD are possible candidates to implement such an approach.

42 ENGINEERING↗

Notes on Asay Foil Analysis

As is the norm for momentum diagnostic analyses (i.e., both piezopin and Asay foil measurements), we begin by assuming all particles are created instantaneously at the moment of shock breakout; that all particles move collinearly through a perfect vacuum from source to sensor with a long mean free path to scattering (i.e., so that particle velocities and areal masses do not change in flight); and that the particles collide perfectly inelastically with the sensor. We also assume the foil supports have a negligible effect on the trajectory, as has been demonstrated experimentally, and the foil is sufficiently thin that corrections for thick-plate effects (e.g., time delays between particle impacts on the collecting side and velocity changes on the probe side) can be disregarded. We seek an exact analytic treatment of an ideal system that perfectly embodies these characteristics.

36 MATERIALS SCIENCE↗

Performance of commercial off-the-shelf microelectromechanical systems sensors in a pulsed reactor environment

Prompted by the unexpected failure of piezoresistive sensors in both an elevated gamma-ray environment and reactor core pulse tests, we initiated radiation testing of several MEMS piezoresistive accelerometers and pressure transducers to ascertain their radiation hardness. Some commercial off-the-shelf sensors are found to be viable options for use in a high-energy pulsed reactor, but others suffer severe degradation and even catastrophic failure. Although researchers are promoting the use of MEMS devices in radiation-harsh environment, we nevertheless find assurance testing necessary.

36 MATERIALS SCIENCE↗

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗