Thermal investigation of a large lunar telescope

Recent interest in construction of a large telescope on the lunar surface (Nein and Davis, 1991; Bely, Burrows, and Illingworth, 1989) has prompted this feasibility study of a thermal control system for a 16 meter diameter telescope located near the lunar equator. In addition to detailed analyses for a telescope located in a flat area near the equator, the thermal effect of locating the telescope in a crater, on a hill, and at higher latitude sites is discussed. Because an unprotected telescope experiences a wide range of temperature swings, several thermal protection schemes have been examined, including domes, sunshades, and ground shields to limit the temperature excursions of the primary mirror. Results of these analyses indicate that mirror temperature excursions can be limited to less than 100 Kelvin (K) per lunar cycle with an appropriate passive thermal protection system (dome), and that the telescope primary mirror can be maintained at less than 100 K for at least 7 days of each lunar cycle. However, such a dome precludes observations during the lunar day. Mirror temperature excursions can be reduced by incorporating thermal enclosures or shades in the design or by placing the telescope at a higher latitude.

Walker, Sherry T.↗

Temperatures and Stresses on Hollow Blades For Gas Turbines

The present treatise reports on theoretical investigations and test-stand measurements which were carried out in the BMW Flugmotoren GMbH in developing the hollow blade for exhaust gas turbines. As an introduction the temperature variation and the stress on a turbine blade for a gas temperature of 900 degrees and circumferential velocities of 600 meters per second are discussed. The assumptions onthe heat transfer coefficients at the blade profile are supported by tests on an electrically heated blade model. The temperature distribution in the cross section of a blade Is thoroughly investigated and the temperature field determined for a special case. A method for calculation of the thermal stresses in turbine blades for a given temperature distribution is indicated. The effect of the heat radiation on the blade temperature also is dealt with. Test-stand experiments on turbine blades are evaluated, particularly with respect to temperature distribution in the cross section; maximum and minimum temperature in the cross section are ascertained. Finally, the application of the hollow blade for a stationary gas turbine is investigated. Starting from a setup for 550 C gas temperature the improvement of the thermal efficiency and the fuel consumption are considered as well as the increase of the useful power by use of high temperatures. The power required for blade cooling is taken into account.

Pollmann, Erich↗

Long-term ultrasonic monitoring of concrete affected by alkali-silica reaction

This article presents continuous monitoring results of alkali-silica reaction (ASR) development in concrete specimens for over 400 days using ultrasonic testing and expansion measurements. Eight concrete specimens with nonreactive aggregate (Control), reactive coarse aggregate, and reactive fine aggregates were cast with two reinforced confinement conditions. The specimens were conditioned in an environmental chamber with high temperature and humidity (38°C and 90% relative humidity) to accelerate the ASR development. A multichannel ultrasonic monitoring system was developed to collect ultrasonic signals automatically, and the expansions in three directions were measured periodically. Results showed that the relative velocity change could detect the ASR initiation in all reactive specimens and show a correlation with expansion in the early stage. However, these correlations are inconsistent for different ASR specimens, and the velocity change becomes less sensitive to ASR damage in the late stage (after 300 days). Irrecoverable velocity drop was observed during every chamber shutdown period, especially in specimens with higher levels of ASR damage. This phenomenon suggests that the nonlinear ultrasonic response caused by the ambient temperature variation may indicate the ASR damage.

Engineering↗

Paramagnetic resonance and susceptibility of ilmenite, FeTiO3 crystal

Large high-purity single crystals of FeTiO3 with ilmenite structure have been grown from a stoichiometric melt of Fe2O3 and TiO2 under an inert atmosphere using the modified Czochralski technique. Susceptibility and X-band paramagnetic resonance studies have been performed. Susceptibility measurements indicate a Neel temperature of about 59 K. The paramagnetic resonance spectrum for magnetic field perpendicular to the crystal c axis consists of a portion of a single, very intense approximately Lorentzian absorption line with its peak at about 600 G and half width at half maximum almost 1200 G. The absorption extends to zero magnetic field. For magnetic field approximately parallel to the c axis, the paramagnetic absorption is much smaller and may be considered a superposition of two approximately Lorentzian line shapes. The magnetic resonance measurements indicate a weak temperature dependence and large angular anisotropy.

Mcdonald, P. F.↗

The critical currents in superconducting tin films

The nonlinear current-voltage curves exhibited by tin films in the flux flow state have made studies of the amount of heating present in the sample necessary. The samples in this work consisted of an evaporated tin film on one side of a 2 mm thick crystal quartz substrate and a carbon film of the same configuration as the tin film on the back of the substrate. The carbon film was used as a thermometer to measure the temperature rise of the tin film above the bath temperature. The heating results indicate negligible effects in the samples. Temperature ratios as small as 0.80 for the tin samples have been investigated and the current-voltage characteristics are still nonlinear, indicating that the source of the nonlinearity is not Joule heating in the samples.

Payne, J. E.↗

Effects of Long-Term Thermal Exposure on Commercially Pure Titanium Grade 2 Elevated-Temperature Tensile Properties

Elevated-temperature tensile testing of commercially pure titanium (CP Ti) Grade 2 was conducted for as-received commercially produced sheet and following thermal exposure at 550 and 650 K (531 and 711 F) for times up to 5000 h. The tensile testing revealed some statistical differences between the 11 thermal treatments, but most thermal treatments were statistically equivalent. Previous data from room temperature tensile testing was combined with the new data to allow regression and development of mathematical models relating tensile properties to temperature and thermal exposure. The results indicate that thermal exposure temperature has a very small effect, whereas the thermal exposure duration has no statistically significant effects on the tensile properties. These results indicate that CP Ti Grade 2 will be thermally stable and suitable for long-duration space missions.

Ellis, David L.↗

Fluorine negative ion detachment kinetics

A study of the rate of F(-) detachment by O and H atoms via the reactions F(-) + O yields FO + e and F(-) + H yields FH+ e was undertaken using a drift tube to produce F(-) ions at various drift velocities and therefore different ion temperatures. Preliminary mobility measurements of F(-) ions in Ar were made, indicating that ion temperatures in the 300 K to 5000 K range could be achieved; however due to numerous difficulties experienced in obtaining a reliable F(-) ion source, the study could not be completed.

Burke, R. R.↗

Recovery and Time-response Characteristics of Six Thermocouple Probes in Subsonic and Supersonic Flow

Experimental data obtained from three shielded and three unshielded thermocouple probes are presented. Data taken in air at room temperature over the ranges 0.2 to 2.2 Mach number and 0.2 to 2.2 atmospheres total pressure show reproducible systematic variations of recovery with Mach number, ambient pressure, flow angle, and probe design. Time-constant data determined at Mach 0.2 and room temperature and pressure indicate that unshielded probes are several times faster in response to temperature changes than shielded probes.

Stickney, Truman M↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing Satellite- and Ground-Based Observations of Cloud Occurrence Over High Southern Latitudes

The 2B-CLDCLASS-LIDAR R05 (2BCL5) and the raDAR/liDAR (DARDAR) satellite retrievals of cloud occurrence are compared as a function of altitude and latitude. The largest disparities are observed at low altitudes over high southern latitudes. These data sets are cross referenced to ground-based measurements from the Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) campaign at McMurdo Station, Antarctica. Compared with AWARE observations, both 2BCL5 and DARDAR underestimate cloud occurrence below 1.5 km, with 2BCL5 and DARDAR distinguishing roughly one third of cloud occurrences observed by AWARE at 0.5 km. While DARDAR identifies greater cloud occurrences than 2BCL5 below 1.5 km, cloud occurrence values for the two data sets have similar differences relative to ground-based measurements. Therefore, the DARDAR retrievals of greater cloud occurrence at low altitudes are likely due to a larger quantity of false positives associated with radar ground clutter or attenuated lidar retrievals. DARDAR cloud occurrences match better with AWARE than 2BCL5 above 5 km. However, the likely underestimation of ground-based measurements at higher altitudes suggests DARDAR may underestimate high level cloud occurrence. Finally, both data sets indicate the presence of liquid containing clouds at temperatures within the homogeneous freezing regime, despite the fact that the ECMWF-AUX data set implemented in their processing clearly indicates temperatures below -38°C. Finally, using AWARE radiosonde (ECMWF-AUX) temperature data, we find that 2BCL5 detects 13.3% (13.8%) of mixed phase clouds below -38°C, while DARDAR detects 5.7% (6.6%) of mixed phase and 1.1% (1.3%) of liquid phase clouds below -38°C.

54 ENVIRONMENTAL SCIENCES↗

Pioneer Saturn infrared radiometer - Preliminary results

Preliminary results of the infrared radiometer experiment on Pioneer Saturn are reported. The instrument made use of two broadband channels centered at 20 and 45 microns which scan at a fixed 75-deg angle with respect to the spacecraft spin axis to acquire 10,000 image pairs of Saturn and its rings in the 2.5 h before closest approach, as well as several observations of Titan. The intensities of radiation observed in both bands indicate an effective temperature of 94.4 + or - 3 K for the planet, implying a total emission greater than twice the absorbed sunlight. Infrared data also indicates a molecular abundance of 0.85 for H2 relative to H2 + He, which can be improved by comparing the derived temperature profiles and radio occultation data. Planetary temperatures are found to range from a minimum of 83 to 140 K at the 1 bar level, with differences of 2.5 K between belts and zones up to the 0.06-bar level, while ring temperatures range from 60 to 70 K on the illuminated side and from less than 60 to 67 K in the planet's shadow and average 55 K on the unilluminated side. Preliminary estimates indicate a 45-micron brightness temperature of 80 + or - 10 K for Titan.

Ingersoll, A. P.↗

Describing the Mechanism of Instability Suppression Using a Central Pilot Flame With Coupled Experiments and Simulations

Pilot flames are commonly used to extend combustor operability limits and suppress combustion oscillations in low-emissions gas turbines. Combustion oscillations, a coupling between heat release rate oscillations and combustor acoustics, can arise at the operability limits of low-emissions combustors where the flame is more susceptible to perturbations. While the use of pilot flames is common in land-based gas turbine combustors, the mechanism by which they suppress instability is still unclear. In this study, we consider the impact of a central jet pilot on the stability of a swirl-stabilized flame in a variable-length, single-nozzle combustor. Previously, the pilot flame was found to suppress the instability for a range of equivalence ratios and combustor lengths. We hypothesize that combustion oscillation suppression by the pilot occurs because the pilot provides hot gases to the vortex breakdown region of the flow that recirculate and improve the static, and hence dynamic, stability of the main flame. This hypothesis is based on a series of experimental results that show that pilot efficacy is a strong function of pilot equivalence ratio but not pilot flow rate, which would indicate that the temperature of the pilot products as well as the combustion intensity of the pilot flame play more of a role in oscillation stabilization than the length of the pilot flame relative to the main flame. Further, the pilot-flame efficacy increases with pilot-flame equivalence ratio until it matches the main-flame equivalence ratio; at pilot equivalence ratios greater than the main equivalence ratio, the pilot-flame efficacy does not change significantly with pilot equivalence ratio. To understand these results, we use large-eddy simulation (LES) to provide a detailed analysis of the flow in the region of the pilot flame and the transport of radical species in the region between the main flame and pilot flame. Furthermore, the simulation, using a flamelet/progress variable-based chemistry tabulation approach and standard eddy viscosity/diffusivity turbulence closure models, provides detailed information that is inaccessible through experimental measurements.

42 ENGINEERING↗

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Structural, Electronic, and Thermal Properties of CdSnAs 2

Structural, electrical, and thermal properties of CdSnAs 2 , with analyses from temperature-dependent transport properties over a large temperature range, are reported. Phase-pure microcrystalline powders were synthesized that were subsequently densified to a high-density homogeneous polycrystalline specimen for this study. Temperature-dependent transport indicates n-type semiconducting behavior with a very high and nearly temperature independent mobility over the entire measured temperature range, attributed to the very small electron effective mass of this material. The Debye model was successfully applied to model the thermal conductivity and specific heat. Furthermore, this work contributes to the fundamental understanding of this material, providing further insight and allowing for investigations into altering this and related physical properties of these materials for technological applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Primordial refractory metal particles in the Allende meteorite

Refractory metal particles containing Os, Re, W, Mo, Ir, and Ru were observed in a Ca-Al-rich inclusion in the Allende meteorite. These particles are the closest to unaltered primordial metal condensates from a nebula yet reported, and appear to have been isolated from the nebula before the condensation of refractories was complete. Computer calculations of condensation indicate that the temperature of isolation appears to be close to the calculated temperature of first formation of oxides (about 1620 K at 0.0001 atm) indicating that isolation may have been effected by coating of the particles by oxides.

Blander, M.↗

Topoclimatological survey of Switzerland

The application of Heat Capacity Mapping Mission data to subsynoptic climate analysis of Switzerland was examined. The data included the surface temperature distributions of urban heat islands and the Swiss Alps. Analog and digital data evaluation procedures are described as well as the ground truth acquisition and comparison program. The dependence of the temperature distributions on topography and surface coverage types is assessed. The results indicate that air temperature inversion zones are detectable.

Winiger, M.↗