Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tabulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Time-Spectral Analysis Methods for Spent Fuel Assay Using Lead Slowing-Down Spectroscopy of Spent Fuel

Nondestructive techniques for measuring the mass of fissile isotopes in spent nuclear fuel is a considerable challenge in the safeguarding of nuclear fuel cycles. A nondestructive assay technology that could provide direct measurement of fissile mass, particularly for the plutonium (Pu) isotopes, and improve upon the uncertainty of today’s confirmatory methods is needed. Lead slowing-down spectroscopy (LSDS) has been studied for the spent fuel application previously, but the nonlinear effects of assembly self shielding (of the interrogating neutron population) have led to discouraging assay accuracy for realistic pressurized water reactor fuels. In this paper, we describe the development of time-spectral analysis algorithms for LSDS intended to overcome these self-shielding effects. The algorithm incorporates the tabulated energy-dependent cross sections from key fissile and absorbing isotopes, but leaves their mass as free variables. Multi-parameter regression analysis is then used to directly calculate not only the mass of fissile isotopes in the fuel assembly (e.g., Pu-239, U-235, and Pu-241), but also the mass of key absorbing isotopes such as Pu-240 and U-238. Modeling-based assay results using a first-order self-shielding relationship indicate that LSDS has the potential to directly measure fissile isotopes with less than 5% average relative error, over a wide fuel burnup range. Shortcomings in the first-order self-shielding model and methods to improve the formulation are described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Description of Freudenthalidium gen. nov. and Halluxium gen. nov. to Formally Recognize Clades Fr3 and H as Genera in the Family Symbiodiniaceae (Dinophyceae)

The Symbiodiniaceae are a family of marine dinoflagellates known mostly for their endosymbiotic interactions with invertebrates and protists, but facultatively and exclusively free‐living life histories in this family are also evident. A recent systematic revision of the Symbiodiniaceae replaced the clade‐based nomenclature of seven divergent lineages of “ Symbiodinium ” sensu lato with one based on formally described genera. The revised taxonomy was not extended to the whole group because type species to describe a new genus for each of the remaining clades and subclades were lacking. In an effort to characterize benthic habitats of symbiodiniaceans in sediments at Heron Island (Great Barrier Reef, Australia), we isolated >100 monoclonal Symbiodiniaceae cultures. Four of these belonged to Symbiodiniaceae ‘subclade’ Fr3, and three to Clade H, based on nucleotide sequence similarity (ITS2, LSU, cp23S, and mtCOB), representing the first cultures of these taxa. Based on these isolates, we propose two new genera: Freudenthalidium gen. nov. and Halluxium gen. nov., circumscribing Clades Fr3 and H, respectively. Three new species are described: Freudenthalidium heronense , F. endolithicum , and Halluxium pauxillum . Kofoidian tabulations of motile cells confirm previous observations that amphiesmal vesicle arrangements are generally conserved across the family. These descriptions are an important step toward completing the systematic revision of the Symbiodiniaceae. That this contribution was enabled by isolates from an endopsammic habitat highlights the potential of discovering new symbiodiniacean species in the environment, the study of which will lead to a deeper understanding of free‐living versus symbiotic life histories in this ecologically important family of dinoflagellates.

Nitschke, Matthew R.↗

Numerical Investigation of a Central Fuel Property Hypothesis Under Boosted Spark-Ignition Conditions

In the present work, a central fuel property hypothesis (CFPH), which states that fuel properties are sufficient to provide an indication of a fuel’s performance irrespective of its chemical composition, was numerically investigated. In particular, the objective of the study was to determine whether Research Octane Number (RON) and Motor Octane Number (MON), as fuel properties, are sufficient to describe a fuel’s knock-limited performance under boosted spark-ignition (SI) conditions within the framework of CFPH. To this end, four TPRF-bioblendstock surrogates having different compositions but matched RON (=98) and MON (=90), were first generated using a non-linear regression model based on artificial neural network (ANN). Additionally, three unconventional bioblendstocks were included in the analysis: di-isobutylene (DIB), isobutanol, and Anisole. Skeletal reaction mechanisms were generated for the TPRF-DIB, TPRF-isobutanol, and TPRF-anisole blends from a detailed kinetic mechanism. Thereafter, numerical simulations were performed for the fuel surrogates using the skeletal mechanisms and a virtual cooperative fuel research (CFR) engine model, under a representative boosted operating condition. In the computational fluid dynamics (CFD) model, the G-equation approach was employed to track the turbulent flame front and the well-stirred reactor model combined with the multi-zone binning strategy was used to capture auto-ignition in the end-gas. In addition, laminar flame speed (LFS) was tabulated for each blend as a function of pressure, temperature, and equivalence ratio a priori, and the lookup tables were used to prescribe laminar flame speed as an input to the G-equation model. Parametric spark timing sweeps were performed for each fuel blend to determine the corresponding knock-limited spark advance (KLSA) and 50% burn point (CA50) at the respective KLSA timing. It was observed that despite same RON, MON, and engine operating conditions, the TPRF-anisole blend exhibited markedly different knock-limited performance from the other three blends. This deviation from the octane index (OI) expectation was shown to be caused by differences in laminar flame speed. However, it was found that relatively large fuel-specific differences in LFS (>20%) would have to be present to cause any appreciable deviation from the OI framework. Otherwise, RON and MON would still be robust enough to predict a fuel’s knock-limited performance.

42 ENGINEERING↗

A High-Fidelity Modeling Tool to Support the Design of Oxy-Combustors for Direct-Fired Supercritical CO2 Cycles

The challenge in the design of oxy-combustors for direct-fired supercritical CO 2 (sCO 2 ) cycles is in addressing disparate performance metrics and objectives. Key design parameters to consider include, among others, injector design for mixing and flame stability, split of recycled CO 2 diluent between injectors and cooling films, target flame temperatures to control noncondensable products, and strategies to inject the diluent CO 2 for film cooling and thermal control. In order to support novel oxy-combustor designs, a high-fidelity yet numerically efficient modeling framework based on the CRUNCH CFD® flow solver is presented, featuring key physics-based submodels relevant in this regime. For computational efficiency in modeling large kinetic sets, a flamelet/progress variable (FPV) based tabulated-chemistry approach is utilized featuring a three-stream extension to allow for the simulation of the CO 2 film cooling stream in addition to the fuel and oxidizer streams. Finite rate chemistry effects are modeled in terms of multiple progress variables for the primary flame as well as for slower-evolving chemical species such as NO x and SO x contaminants. Real fluid effects are modeled using advanced equations of states. The predictive capabilities of this computationally tractable design support tool are demonstrated on a conceptual injector design for an oxy-combustor operating near 30 MPa. Simulations results provide quantitative feedback on the effectiveness of the film cooling as well as the level of contaminants (CO, NO, and N) in the exhaust due to impurities entering from the injectors. These results indicate that this framework would be a useful tool for refining and optimizing the oxy-combustor designs as well as risk mitigation analyses.

Engineering↗

Thermal Aging Effects on the Yield and Tensile Strength of 9Cr-1Mo-V (Grade 91)

The long-term exposure of 9Cr-1Mo-V (Grade 91) steel to elevated temperature can have a significant effect on reducing its yield and tensile strength. The yield and tensile strength changes, in turn, have potential implications to the assurance of the integrity of components constructed with this material over their design or intended lifetime. The ASME Boiler & Pressure Vessel Code (BPVC), Section III, Division 5 (III-5, high temperature reactors) provides tabulated reduction factors for Grade 91 yield and tensile strength as a function of exposure temperature and time up to 300,000 h. ASME BPVC III-5 s intent to extend these factors to an exposure duration of 500,000 h, the lack of available historic information to support the existing factors, and the recent development of a physics-based prediction model for ASME BPVC application are prime motivation for this study. This work describes results of the conventional time-temperature Hollomon–Jaffe parameter, strength reduction ratio prediction method using an updated, extensive Grade 91 unaged and related aged material strength database. The method, previously used by Oak Ridge National Laboratory in its evaluation of Grade 91 and likely used in development of the existing BPVC III-5 reduction factors, provides strength reduction ratio predictions useful for general component fitness-for-service assessments and for computing BPVC III-5 reduction factors as defined. Specific reduction factors to 500,000 h at 650 °C applicable to ASME BPVC III-5 are computed from the strength reduction ratios.

36 MATERIALS SCIENCE↗

Numerical Investigation of a Central Fuel Property Hypothesis under Boosted Spark-ignition Conditions

In the present work, a central fuel property hypothesis (CFPH), which states that fuel properties are sufficient to provide an indication of a fuel's performance irrespective of its chemical composition, was numerically investigated In particular, the objective of the study was to determine whether Research Octane Number (RON) and Motor Octane Number (MON), as fuel properties, are sufficient to describe a fuel's knock-limited performance under boosted spark-ignition (SI) conditions within the framework of CFPH. To this end, four TPRF-bioblendstock surrogates having different compositions but matched RON (= 98) and MON (= 90), were first generated using a non-linear regression model based on artificial neural network (ANN). Three unconventional bioblendstocks were included in the analysis: Di-isobutylene (DIB), Isobutanol and Anisole. Skeletal reaction mechanisms were generated for the TPRF-DIB, TPRF-isobutanol and TPRF-anisole blends from a detailed kinetic mechanism. Thereafter, numerical simulations were performed for the fuel surrogates using the skeletal mechanisms and a virtual cooperative fuel research (CFR) engine model, under a representative boosted operating condition. In the computational fluid dynamics (CFD) model, the G-equation approach was employed to track the turbulent flame front and the well-stirred reactor model combined with multi-zone binning strategy was used to capture auto-ignition in the end-gas. In addition, laminar flame speed was tabulated for each blend as a function of pressure, temperature and equivalence ratio a priori, and the lookup tables were used to prescribe laminar flame speed as an input to the G-equation model. Parametric spark timing sweeps were performed for each fuel blend to determine the corresponding knock-limited spark advance (KLSA) and 50% burn point (CA50) at the respective KLSA timing. It was observed that despite same RON, MON and engine operating conditions, the TPRF-Anisole blend exhibited markedly different knock-limited performance from the other three blends. This deviation from the octane index (DI) expectation was shown to be caused by differences in laminar flame speed (LFS). However; it was found that relatively large fuel-specific differences in LFS (> 20%) would have to be present to cause any appreciable deviation from the 01 framework. Otherwise, RON and MON would still be robust enough to predict a fuel's knock-limited performance.

Pal, Pinaki↗

SURROGATE MODEL DEVELOPMENT AND VALIDATION FOR RELIABILITY ANALYSIS OF REACTOR PRESSURE VESSELS

In nuclear light water reactors (LWRs), the reactor coolant, core and shroud are contained within a massive, thick walled steel vessel known as a reactor pressure vessel (RPV). Given the tremendous size of these structures, RPVs typically contain a large population of pre-existing flaws introduced in the manufacturing process. After many years of operation, irradiation-induced embrittlement makes these vessels increasingly susceptible to fracture initiation at the locations of the pre-existing flaws. Because of the uncertainty in the loading conditions, flaw characteristics and material properties, probabilistic methods are widely accepted and used in assessing RPV integrity. The Fracture Analysis of Vessels – Oak Ridge (FAVOR) computer program developed by researchers at Oak Ridge National Laboratory is widely used for this purpose. This program can be used in order to perform deterministic and probabilistic risk-informed analyses of the structural integrity of an RPV subjected to a range of thermal-hydraulic events. FAVOR uses a one-dimensional representation of the global response of the RPV, which is appropriate for the beltline region, which experiences the most embrittlement, and employs an influence coefficient technique to rapidly compute stress intensity factors for axis-aligned surface-breaking flaws. The Grizzly code is currently under development at Idaho National Laboratory (INL) to be used as a general multiphysics simulation tool to study a variety of degradation mechanisms in nuclear power plant components. The first application of Grizzly has been to study fracture in embrittled RPVs. Grizzly can be used to model the thermo-mechanical response of an RPV under transient conditions observed in a pressurized thermal shock (PTS) scenario. The global response of the vessel provides boundary conditions for local 3D models of the material in the vicinity of a flaw. Fracture domain integrals are computed to obtain stress intensity factors, which can in turn be used to assess whether a fracture would initiate at a pre-existing flaw. To use Grizzly for probabilistic analysis, it is necessary to have a way to rapidly evaluate stress intensity factors. To accomplish this goal, a reduced order model (ROM) has been developed to efficiently represent the behavior of a detailed 3D Grizzly model used to calculate fracture parameters. This approach uses the stress intensity factor influence coefficient method that has been used with great success in FAVOR. Instead of interpolating between tabulated solutions, as FAVOR does, the ROM approach uses a response surface methodology to compute fracture solutions based on a sampled set of results used to train the ROM. The main advantages of this approach are that the process of generating the training data can be fully automated, and the procedure can be readily used to consider more general flaw configurations. This paper demonstrates the procedure used to generate a ROM to rapidly compute stress intensity factors for axis-aligned flaws. The results from this procedure are in good agreement with those produced using the traditional influence coefficient interpolation procedure, which gives confidence in this method. This paves the way for applying this procedure for more general flaw configurations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A model for calculating resputter rates in codeposition

The ability to calculate composition in composition spread thin films is a powerful tool in combinatorial research. This ability is pivotal in high-throughput studies, where the time and effort required to determine elemental compositions using standard techniques can be prohibitive. Calculating codeposited film composition from single-source deposition profiles requires a model for film growth in codeposition. In dc magnetron sputtering, modeling film growth as the simple addition of individual rates can lead to significant errors, primarily due to resputtering of film atoms by energetically reflected gas atoms. We develop a model which includes the definition of a resputter coefficient that is used to calculate resputtering rates in the codeposition of an arbitrary number of sources. The accuracy of the model is demonstrated for the codeposition of Pt and Pb. In the development of the model, useful parametrizations of fundamental quantities of sputter dynamics are presented, and the authors also present tabulated values of the resputter coefficient for 27 commonly sputtered elements at select sputter voltages.

36 MATERIALS SCIENCE↗

Estimating radiological background using imaging spectroscopy

Optical imaging spectroscopy is investigated as a method to estimate radiological background by spectral identification of soils, sediments, rocks, minerals and building materials derived from natural materials and assigning tabulated radiological emission values to these materials. Radiological airborne surveys are undertaken by local, state and federal agencies to identify the presence of radiological materials out of regulatory compliance. Detection performance in such surveys is determined by (among other factors) the uncertainty in the radiation background; increased knowledge of the expected radiation background will improve the ability to detect low-activity radiological materials. Radiological background due to naturally occurring radiological materials (NORM) can be estimated by reference to previous survey results, use of global 40K, 238U, and 232Th (KUT) values, reference to existing USGS radiation background maps, or by a moving average of the data as it is acquired. Each of these methods has its drawbacks: previous survey results may not include recent changes, the global average provides only a zero-order estimate, the USGS background radiation map resolutions are coarse and are accurate only to 1 km – 25 km sampling intervals depending on locale, and a moving average may essentially low pass filter the data to obscure small changes in radiation counts. Imaging spectroscopy from airborne or spaceborne platforms can offer higher resolution identification of materials and background, as well as provide imaging context information. AVIRIS hyperspectral image data is analyzed using commercial exploitation software to determine the usefulness of imaging spectroscopy to identify qualitative radiological background emissions when compared to airborne radiological survey data.

background radiation estimation↗

Energy-range relation and mean energy variation in therapeutic particle beams

Analytical expressions for the mean energy and range of therapeutic light ion beams and low- and high-energy electrons have been derived, based on the energy dependence of their respective stopping powers. The new mean energy and range relations are power-law expressions relevant for light ion radiation therapy, and are based on measured practical ranges or known tabulated stopping powers and ranges for the relevant incident particle energies. A practical extrapolated range, R{sub p}, for light ions was defined, similar to that of electrons, which is very closely related to the extrapolated range of the primary ions. A universal energy-range relation for light ions and electrons that is valid for all material mixtures and compounds has been developed. The new relation can be expressed in terms of the range for protons and alpha particles, and is found to agree closely with experimental data in low atomic number media and when the difference in the mean ionization energy is low. The variation of the mean energy with depth and the new energy-range relation are useful for accurate stopping power and mass scattering power calculations, as well as for general particle transport and dosimetry applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comments on shielding for dual energy accelerators

Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1x16.2 cm{sup 2} for 6 MV and 14.1x16.8 cm{sup 2} for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm{sup 2}, respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm{sup 2} for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 deg. was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 deg. were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fundamental x-ray interaction limits in diagnostic imaging detectors: Frequency-dependent Swank noise

A frequency-dependent x-ray Swank factor based on the ''x-ray interaction'' modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI{sub 2}) for incident photon energies between 10 and 150 keV and various converter thicknesses. When scaled by the quantum efficiency, the x-ray Swank factor describes the best possible detective quantum efficiency (DQE) a detector can have. As such, this x-ray interaction DQE provides a target performance benchmark. It is expressed as a function of (Fourier-based) spatial frequency and takes into consideration signal and noise correlations introduced by reabsorption of Compton scatter and photoelectric characteristic emissions. It is shown that the x-ray Swank factor is largely insensitive to converter thickness for quantum efficiency values greater than 0.5. Thus, while most of the tabulated values correspond to thick converters with a quantum efficiency of 0.99, they are appropriate to use for many detectors in current use. A simple expression for the x-ray interaction DQE of digital detectors (including noise aliasing) is derived in terms of the quantum efficiency, x-ray Swank factor, detector element size, and fill factor. Good agreement is shown with DQE curves published by other investigators for each converter material, and the conditions required to achieve this ideal performance are discussed. For high-resolution imaging applications, the x-ray Swank factor indicates: (i) a-Si should only be used at low-energy (e.g., mammography); (ii) a-Se has the most promise for any application below 100 keV; and (iii) while quantum efficiency may be increased at energies just above the K edge in CsI and PbI{sub 2}, this benefit is offset by a substantial drop in the x-ray Swank factor, particularly at high spatial frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

More accurate fitting of {sup 125}I and {sup 103}Pd radial dose functions

In this study an improved functional form for fitting the radial dose functions, g(r), of {sup 125}I and {sup 103}Pd brachytherapy seeds is presented. The new function is capable of accurately fitting radial dose functions over ranges as large as 0.05 cm{<=}r{<=}10 cm for {sup 125}I seeds and 0.10 cm{<=}r{<=}10 cm for {sup 103}Pd seeds. The average discrepancies between fit and calculated data are less than 0.5% over the full range of fit and maximum discrepancies are 2% or less. The fitting function is also capable of accounting for the sharp increase in g(r) (upturn) seen for some sources for r<0.1 cm. This upturn has previously been attributed to the breakdown of the approximation of the sources as a line, however, in this study we demonstrate that another contributing factor is the 4.5 keV characteristic x-rays emitted from the Ti seed casing. Radial dose functions are calculated for 18 {sup 125}I seeds and 9 {sup 103}Pd seeds using the EGSnrc Monte Carlo user-code BrachyDose. Fitting coefficients of the new function are tabulated for all 27 seeds. Extrapolation characteristics of the function are also investigated. The new functional form is an improvement over currently used fitting functions with its main strength being the ability to accurately fit the rapidly varying radial dose function at small distances. The new function is an excellent candidate for fitting the radial dose function of all {sup 103}Pd and {sup 125}I brachytherapy seeds and will increase the accuracy of dose distributions calculated around brachytherapy seeds using the TG-43 protocol over a wider range of data. More accurate values of g(r) for r<0.5 cm may be particularly important in the treatment of ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An EGSnrc Monte Carlo-calculated database of TG-43 parameters

Monte Carlo methods are used to calculate a complete TG-43 dosimetry parameter data set for 27 low-energy photon emitting brachytherapy sources (18 {sup 125}I and 9 {sup 103}Pd). All Monte Carlo calculations are performed using the EGSnrc user-code BrachyDose. TG-43 dosimetry parameters, including dose rate constants, radial dose functions (with functional fitting parameters), and anisotropy data, are calculated with finer spatial resolution, greater range of distances, and smaller uncertainties than data currently available in the literature for many of these sources. In particular, for most of the seeds, this is the first time that anisotropy data have been tabulated at distances less than 0.5 cm from the source. These calculations employ the state-of-the-art XCOM photon cross sections, and detailed source geometries are modeled using Yegin's multigeometry package. This data set serves as a completely independent verification of the currently available dosimetry parameters calculated using other Monte Carlo codes, including MCNP and PTRAN. This report also describes the Carleton Laboratory for Radiotherapy Physics TG-43 Parameter Database, a publicly accessible web site (at http://www.physics.carleton.ca/clrp/seed{sub d}atabase/) through which all of the data calculated for this study can be accessed. Also available on the web site are descriptions of the methods and Monte Carlo models used in this study and comparisons of data calculated in this study with data calculated by other authors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reference dosimetry condition and beam quality correction factor for CyberKnife beam

This article is intended to improve the certainty of the absorbed dose determination for reference dosimetry in CyberKnife beams. The CyberKnife beams do not satisfy some conditions of the standard reference dosimetry protocols because of its unique treatment head structure and beam collimating system. Under the present state of affairs, the reference dosimetry has not been performed under uniform conditions and the beam quality correction factor k{sub Q} for an ordinary 6 MV linear accelerator has been temporally substituted for the k{sub Q} of the CyberKnife in many sites. Therefore, the reference conditions and k{sub Q} as a function of the beam quality index in a new way are required. The dose flatness and the error of dosimeter reading caused by radiation fields and detector size were analyzed to determine the reference conditions. Owing to the absence of beam flattening filter, the dose flatness of the CyberKnife beam was inferior to that of an ordinary 6 MV linear accelerator. And if the absorbed dose is measured with an ionization chamber which has cavity length of 2.4, 1.0 and 0.7 cm in reference dosimetry, the dose at the beam axis for a field of 6.0 cm collimator was underestimated 1.5%, 0.4%, and 0.2% on a calculation. Therefore, the maximum field shaped with a 6.0 cm collimator and ionization chamber which has a cavity length of 1.0 cm or shorter were recommended as the conditions of reference dosimetry. Furthermore, to determine the k{sub Q} for the CyberKnife, the realistic energy spectrum of photons and electrons in water was simulated with the BEAMnrc. The absence of beam flattening filter also caused softer photon energy spectrum than that of an ordinary 6 MV linear accelerator. Consequently, the k{sub Q} for ionization chambers of a suitable size were determined and tabulated as a function of measurable beam quality indexes in the CyberKnife beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectroscopic output of {sup 125}I and {sup 103}Pd low dose rate brachytherapy sources

The spectroscopic output of low dose rate (LDR) brachytherapy sources is dependent on the physical design and construction of the source. Characterization of the emitted photons from 12 {sup 125}I and 3 {sup 103}Pd LDR brachytherapy source models is presented. Photon spectra, both along the transverse bisector and at several polar angles, were measured in air with a high-purity reverse electrode germanium (REGe) detector. Measured spectra were corrected to in vacuo conditions via Monte Carlo and analytical methods. The tabulated and plotted spectroscopic data provide a more complete understanding of each source model's output characteristics than can be obtained with other measurement techniques. The variation in fluorescence yield of the {sup 125}I sources containing silver caused greater differences in the emitted spectra and average energies among these seed models than was observed for the {sup 103}Pd sources or the {sup 125}I sources that do not contain silver. Angular spectroscopic data further highlighted the effects of source construction unique to each model, as well as the asymmetric output of many seeds. These data demonstrate the need for the incorporation of such physically measured output characteristics in the Monte Carlo modeling process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of the quality index (Q) for photon beams at arbitrary field sizes

Purpose: A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR{sub 20,10}) for a square field of 10x10 cm{sup 2} and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly required in dosimetry protocols, but certainly influences the measurement of Q, is not always produced. In this work, a method was developed in order to determine Q at any field size, especially for small and nonflattened beams. Methods: An analytical relationship was derived between TPR{sub 20,10} for arbitrary field sizes and Q[the TPR{sub 20,10}(10x10 cm{sup 2})] as quality index. The proposed model equation was fitted to the measured and published data in order to achieve three general fit parameters. The procedure was then tested with published data from TomoTherapy and CyperKnife treatment devices. Results: For standard flattened photon fields, the uncertainty in Q measured at any field size using the parameters derived from this study is better than 1%. In flattening-filter free beams, the proposed procedure results in a reliable Q for any field size setting. Conclusions: A method is introduced and successfully tested in order to measure the beam quality under nonstandard conditions. It can be used, e.g., to get energy dependent correction factors as tabulated in dosimetry codes of practice even if standard conditions are not adjustable.

61 RADIATION PROTECTION AND DOSIMETRY↗