Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

High temperature properties of ceramic fibers and insulations for thermal protection of atmospheric entry and hypersonic cruise vehicles

Multilayer insulations (MIs) which will operate in the 500 to 1000 C temperature range are being considered for possible applications on aerospace vehicles subject to convective and radiative heating during atmospheric entry. The insulations described consist of ceramic fibers, insulations, and metal foils quilted together with ceramic thread. As these types of insulations have highly anisotropic properties, the total heat transfer characteristics must be determined. Data are presented on the thermal diffusivity and thermal conductivity of four types of MIs and are compared to the baseline Advanced Flexible Reusable Surface Insulation currently used on the Space Shuttle Orbiter. In addition, the high temperature properties of the fibers used in these MIs are discussed. The fibers investigated included silica and three types of aluminoborosilicate (ABS). Static tension tests were performed at temperatures up to 1200 C and the ultimate strain, tensile strength, and tensile modulus of single fibers were determined.

Kourtides, Demetrius A.↗

High-Temperature Properties of Ceramic Fibers and Insulations for Thermal Protection of Atmospheric Entry and Hypersonic Cruise Vehicles

Multilayer insulations which will operate in the 500C to 1000C temperature range are being considered for possible applications on aerospace vehicles subject to convective and radiative heating during atmospheric entry. The insulations described in this paper consist of ceramic fabrics, insulations, and metal foils quilted together using ceramic thread. As these types of insulations have highly anisotropic properties, the total heat transfer characteristics of these insulations must be determined. Data are presented on the thermal diffusivity and thermal conductivity of four types of multilayer insulations and are compared to the baseline Advanced Flexible Reusable Surface Insulation

Kourtides, Demetrius A.↗

Thermal protection of H13 steel by growth of (TiAl)N films by PAPVD pulsed arc technique

(TiAl)N Films were grown on H13 steel by a plasma assisted repetitive pulsed arc discharge. To grow the coatings, a TiAl sintered cathode was used, 50% Ti-50% Al. The deposition system consists of a reaction chamber with two electrodes placed face to face. A pulsed power supply, which allows for control of parameters like time active arc, time between arcs, arc energy, and others, is used to generate the discharge. Thermal changes were carried out on H13 steel before and after growing the (TiAl)N films. X-ray diffraction (XRD) was employed to study the coatings, observing the H13 steel and (TiAl)N oxidation temperature. Morphological characteristics were analyzed by means of an Atomic Force Microscopy (AFM). Scanning electron microscopy (SEM) revealed the surface chemical composition of the films and morphological details of the samples.

36 MATERIALS SCIENCE↗

Thermal protection for hypervelocity flight in earth's atmosphere by use of radiation backscattering ablating materials

A heat-shield-material response code predicting the transient performance of a material subject to the combined convective and radiative heating associated with the hypervelocity flight is developed. The code is dynamically interactive to the heating from a transient flow field, including the effects of material ablation on flow field behavior. It accomodates finite time variable material thickness, internal material phase change, wavelength-dependent radiative properties, and temperature-dependent thermal, physical, and radiative properties. The equations of radiative transfer are solved with the material and are coupled to the transfer energy equation containing the radiative flux divergence in addition to the usual energy terms.

Howe, John T.↗

Characterization of Space Shuttle Thermal Protection System (TPS) Materials for Return-to-Flight following the Shuttle Columbia Accident Investigation

During the Space Shuttle Columbia Accident Investigation, it was determined that a large chunk of polyurethane insulating foam (= 1.67 lbs) on the External Tank (ET) came loose during Columbia's ascent on 2-1-03. The foam piece struck some of the protective Reinforced Carbon-Carbon (RCC) panels on the leading edge of Columbia's left wing in the mid-wing area. This impact damaged Columbia to the extent that upon re-entry to Earth, superheGed air approaching 3,000 F caused the vehicle to break up, killing all seven astronauts on board. A paper after the Columbia Accident Investigation highlighted thermal analysis testing performed on External Tank TPS materials (1). These materials included BX-250 (now BX-265) rigid polyurethane foam and SLA-561 Super Lightweight Ablator (highly-filled silicone rubber). The large chunk of foam from Columbia originated fiom the left bipod ramp of the ET. The foam in this ramp area was hand-sprayed over the SLA material and various fittings, allowed to dry, and manually shaved into a ramp shape. In Return-to-Flight (RTF) efforts following Columbia, the decision was made to remove the foam in the bipod ramp areas. During RTF efforts, further thermal analysis testing was performed on BX-265 foam by DSC and DMA. Flat panels of foam about 2-in. thick were sprayed on ET tank material (aluminum alloys). The DSC testing showed that foam material very close to the metal substrate cured more slowly than bulk foam material. All of the foam used on the ET is considered fully cured about 21 days after it is sprayed. The RTF culminated in the successful launch of Space Shuttle Discovery on 7-26-05. Although the flight was a success, there was another serious incident of foam loss fiom the ET during Shuttle ascent. This time, a rather large chunk of BX-265 foam (= 0.9 lbs) came loose from the liquid hydrogen (LH2) PAL ramp, although the foam did not strike the Shuttle Orbiter containing the crew. DMA testing was performed on foam samples taken fiom a simulated PAL ramp panel. It was found that the smooth rind on the foam facing the cable tray did significantly affect the properties of foam at the PAL ramp surface. The smooth rind increased the storage modulus E' of the foam as much as 20- 40% over a temperature range of -145 to 95 C. Because of foam loss fiom the PAL ramp, future Shuttle flights were grounded indefinitely to allow further testing to better understand foam properties. The decision was also made to remove foam from the LH2 PAL, ramp. Other RTF efforts prior to the launch of Discovery included

Wingard, Doug↗

Reusable surface insulation thermal protection systems test evaluation status

Changes in coating morphology of mullite, silica, and ceramic mullite fiber at two heating rates are described followed by a discussion of the changes in surface chemistry that occur during convective heating tests. Subsequently, the surface chemistry changes observed are compared to similar data obtained from radiantly heated coatings and the significance of the difference between the results is discussed. Finally, the changes in chemistry of the coatings in cross section before and after convectively heated cyclic testing are discussed and the significance of surface chemistry changes are described. Results indicate that the thermal conductivity of mullite surface insulation is higher than that of silica insulation, based on thermal response data. Acoustic excitation of cracked silica tiles does not lead to catastrophic failure such as spallation or tile loss. Cracks in mullite material after thermal exposure lead to fracturing of the coating and surface insulation material after acoustic excitation.

Strouhal, G.↗

Status of reusable surface insulation thermal protection system technology programs

The development of three low-density rigidized insulation materials for the shuttle TPS application is reported. These materials consist of one high purity silica system and two systems based on mullite, an aluminum silicate. Both systems consist of fibers joined together with appropriate binders to obtain a rigidized insulation composite. Both material systems require the application of a glassy coating to provide a wear resistant, high emittance surface and to prevent the absorption of water by the fiber matrix. The technology program has addressed the development of water impervious coatings, methods of assembling the materials in design concepts while minimizing the thermal stress in the insulation, achieving compatibility between the RSI material and the structural system, and test evaluations to demonstrate the feasibility of the surface insulation concept.

Greenshields, D. H.↗

Development and validation of purged thermal protection systems for liquid hydrogen fuel tanks of hypersonic vehicles

An economical, lightweight, safe, efficient, reliable, and reusable insulation system was developed for hypersonic cruise vehicle hydrogen fuel tanks. Results indicate that, a nitrogen purged, layered insulation system with nonpermeable closed-cell insulation next to the cryogenic tank and a high service temperature fibrous insulation surrounding it, is potentially an attractive solution to the insulation problem. For the postulated hypersonic flight the average unit weight of the purged insulation system (including insulation, condensate and fuel boil off) is 6.31 kg/sq m (1.29 psf). Limited cyclic tests of large specimens of closed cell polymethacrylimide foam indicate it will withstand the expected thermal cycle.

Helenbrook, R. D.↗

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application

A three-phase program to develop and demonstrate the feasibility of a metallic heat shield suitable for use on Space Shuttle Orbiter class vehicles at operating surface temperatures of up to 1590 K (2400 F) is summarized. An orderly progression of configuration studies, material screening tests, and subscale structural tests was performed. Scale-up feasibility was demonstrated in the final phase when a sizable nine-panel array was fabricated and successfully tested. The full-scale tests included cyclic testing at reduced air pressure to 1590 K (2400 F) and up to 158 dB overall sound pressure level. The selected structural configuration and design techniques succesfully eliminated thermal induced failures. The thermal/structural performance of the system was repeatedly demonstrated. Practical and effective field repair methods for coated columbium alloys were demonstrated. Major uncertainties of accessibility, refurbishability, and durability were eliminated.

Black, W. E.↗

Sizing and Margins Assessment of the Mars2020 Acusil-II Thermal Protection System

The Mars2020 entry vehicle is currently being developed by NASA to safely land its next rover on the Martian surface in 2021. The vehicle will be protected from entry aeroheating using three different TPS materials: PICA tiles on the forebody, SLA-561V on the backshell and Acusil-II on the parachute close-out cone (PCC) and its backshell interface plate (BIP). Mars2020's entry vehicle and TPS design is identical to the Mars Science Laboratory, NASA's last Mars lander; therefore, the purpose of this study is to assess the adequacy of the existing TPS design and thickness for Mars2020 predicted environments. This study focuses on sizing and margin assessment of Acusil-II TPS on the PCC and BIP. The methodology and analysis techniques that were used for assessing thermal margins are reviewed. Analysis assumptions and limitations are discussed in detail. Thermal sizing is performed at different locations and results are presented.

Acusil↗

Design of thermal protection system for 8 foot HTST combustor

The combustor in the 8-foot high temperature structures tunnel at the NASA-Langley Research Center has encountered cracking over a period of 50-250 tunnel tests within a limited range of the required operating envelope. A program was conducted which analyzed the failed combustor liner hardware and determined that the mechanism of failure was vibratory fatigue. A vibration damper system using wave springs located axially between the liner T-bar and the liner support was designed as an intermediate solution to extend the life of the current two-pass regenerative air-cooled liner. The effects of liner wall thickness, cooling air passage height, stiffener ring geometry, reflective coatings, and liner material selection were investigated for these designs. Preliminary layout design arrangements including the external water-cooling system requirements, weight estimates, installation requirements and preliminary estimates of manufacturing costs were prepared for the most promissing configurations. A state-of-the-art review of thermal barrier coatings and an evaluation of reflective coatings for the gasside surface of air-cooled liners are included.

Moskowitz, S.↗

CAVE: A computer code for two-dimensional transient heating analysis of conceptual thermal protection systems for hypersonic vehicles

A digital computer code CAVE (Conduction Analysis Via Eigenvalues), which finds application in the analysis of two dimensional transient heating of hypersonic vehicles is described. The CAVE is written in FORTRAN 4 and is operational on both IBM 360-67 and CDC 6600 computers. The method of solution is a hybrid analytical numerical technique that is inherently stable permitting large time steps even with the best of conductors having the finest of mesh size. The aerodynamic heating boundary conditions are calculated by the code based on the input flight trajectory or can optionally be calculated external to the code and then entered as input data. The code computes the network conduction and convection links, as well as capacitance values, given basic geometrical and mesh sizes, for four generations (leading edges, cooled panels, X-24C structure and slabs). Input and output formats are presented and explained. Sample problems are included. A brief summary of the hybrid analytical-numerical technique, which utilizes eigenvalues (thermal frequencies) and eigenvectors (thermal mode vectors) is given along with aerodynamic heating equations that have been incorporated in the code and flow charts.

Rathjen, K. A.↗

Pterodactyl: Effects of 3D Thermal Analysis on Thermal Protection System Design for a Flap Control System

NASA’s Pterodactyl project has investigated the use of a novel multi-flap control system to facilitate precision targeting of Deployable Entry Vehicles (DEVs) during atmospheric re-entry [1]. DEVs can be folded to fit within the limiting cross-sectional area of current launch systems. Once deployed, the vehicle expands and settles into a pre-determined blunt body shape. While DEVs provide a more efficient solution to increased payload sizes, the absence of a back shell does not allow for easy integration of reaction control systems, which have historically been used for guidance and control (G&C) of rigid aeroshells during entry. One DEV solution, called the Adaptable, Deployable Entry Placement Technology (ADEPT), employs mechanically deployed gores. This provided the Pterodactyl project with the opportunity to incorporate a rib-mounted, 8-flap control system for G&C. Each flap can deflect independently in and out of the hypersonic flow, requiring TPS for the flaps. Previous work within the Pterodactyl project utilized 1D thermal analysis to design the TPS. However, the Pterodactyl project was concerned that the base level tools for 1D thermal analysis were not accounting for the 3D effects of the large heating gradients along and across the flaps, the in-depth in-plane conductivity of the TPS and internal structure, and the effects of the small edge radii at the neck of the flaps. This paper discusses the methodology and results of a 3D thermal analysis of the flap control system. Additionally, the results from the 1D and 3D thermal analyses are compared. It is found that elements of the original design that resulted from the 1D analysis may be overly conservative, and implementation of a 3D thermal analysis indicated a reduction in TPS thickness is feasible. This result helps to reduce the mechanical integration complexity of the flap at the rib tip and realizes potential mass savings.

Sarah N D'Souza↗

The Application of Infrared Thermographic Inspection Techniques to the Space Shuttle Thermal Protection System

The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the "good" material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued where a fixed set of eigenvectors, generated from an analytic model of the thermal response of the material under examination, is used to process the thermal data from the RCC materials. Details of a one-dimensional analytic model and a two-dimensional finite-element model will be presented. An overview of the PCA process as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens will be shown. Finally, a number of different applications of this technology to various RCC components will be presented.

Cramer, K. E.↗

The Application of Principal Component Analysis Using Fixed Eigenvectors to the Infrared Thermographic Inspection of the Space Shuttle Thermal Protection System

The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the good material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued when a fixed set of eigenvectors is used to process the thermal data from the RCC materials. These eigen vectors can be generated either from an analytic model of the thermal response of the material under examination, or from a large cross section of experimental data. This paper will provide the details of the analytic model; an overview of the PCA process; as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens. Details of a system that has been developed to allow insitu inspection of a majority of shuttle RCC components will be presented along with the acceptance test results for this system. Additionally, the results of applying this technology to the Space Shuttle Discovery after its return from flight will be presented.

Cramer, K. Elliott↗

Aerothermal Ground Testing of Flexible Thermal Protection Systems for Hypersonic Inflatable Aerodynamic Decelerators

Flexible TPS development involves ground testing and analysis necessary to characterize performance of the FTPS candidates prior to flight testing. This paper provides an overview of the analysis and ground testing efforts performed over the last year at the NASA Langley Research Center and in the Boeing Large-Core Arc Tunnel (LCAT). In the LCAT test series, material layups were subjected to aerothermal loads commensurate with peak re-entry conditions enveloping a range of HIAD mission trajectories. The FTPS layups were tested over a heat flux range from 20 to 50 W/cm with associated surface pressures of 3 to 8 kPa. To support the testing effort a significant redesign of the existing shear (wedge) model holder from previous testing efforts was undertaken to develop a new test technique for supporting and evaluating the FTPS in the high-temperature, arc jet flow. Since the FTPS test samples typically experience a geometry change during testing, computational fluid dynamic (CFD) models of the arc jet flow field and test model were developed to support the testing effort. The CFD results were used to help determine the test conditions experienced by the test samples as the surface geometry changes. This paper includes an overview of the Boeing LCAT facility, the general approach for testing FTPS, CFD analysis methodology and results, model holder design and test methodology, and selected thermal results of several FTPS layups.

Bruce, Walter E., III↗

Charactarization of Thermal Protection Systems

In 2012, NASA's mission of landing the Mars Science Laboratory (MSL) on Mars was successful. MSL was protected by an ablative heatshield of tiled low density material known as PICA (phenolic impregnated carbon ablator). The heatshield was instrumented with MEDLI (MSL Entry Descent Landing Instrument) a suite of sensors & thermocouples at discrete locations in order to monitor the in-depth ablator temperature response and surface pressure. MEDLI was designed and developed by NASA Langley, in partnership with NASA Ames Research Center for the purposes of probing Mars and evaluating the performance of the spacecraft upon entry into the Martian atmosphere. The flight data reduces the uncertainty in engineer models for predicting the response of a spacecraft towards the extreme heating environment of an entry into the Martian atmosphere. MEDLI2 is a part of the Mars 2020 mission and is the next-generation sensor suite for entry, descent, and landing. This data will again help engineers validate their flight models. Additionally, the atmospheric data, can help us understand atmospheric density and winds. This is a critical study for reducing risks to both robotic and future human missions to Mars. Engineered models for Mars 2020 are dependent upon parameters related to the materials response to heating and radiation. In this work, the thermal properties and other measurements of various ablative materials are analyzed to achieve greater utility of the 2012 MEDLI flight data and more accurately determine the parameters being used in Mars 2020. The purpose of this study was to measure specific heat, thermal conductivity, char yield, reflectance as a function of wavelength, and other thermal parameters and optical properties of various ablative materials. CO2(g) at extreme temperatures emits radiation impacting MEDLI2 flight predictions. Emissivity & absorptivity as a function of temperature were calculated from FTIR and UV-Vis data as a means of investigating whether these materials might absorb CO2 radiation upon entry into the Mars atmosphere.

HEEET↗

A Crystal-Diffraction System Prototype for Measuring Neutron’s Charge: Thermal Protection Test and Vibration Measurements

A prototype system design for ultra-high-precision neutron spectrometry using diffraction in perfect crystals is described. Results of experimental verification of the temperature stability inside the setup are presented. Results of vibration spectrum measurements in working zone of the PF1b beam of ILL reactor (Grenoble, France), where the prototype setup will be arranged for experimental testing, are considered.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗