Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Poster — Thur Eve — 42: Radiochromic film calibration for low-energy seed brachytherapy dose measurement

The purpose of this study was to investigate the accuracy of radiochromic film calibration procedures used in external beam radiotherapy when applied to I-125 brachytherapy sources delivering higher doses, and to determine any necessary modifications to achieve similar accuracy in absolute dose measurements. GafChromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 6 MV, 75 kVp and (∼28 keV) I-125 photon sources. A custom phantom was used for the I-125 irradiations to obtain a larger film area with nearly constant dose to reduce the effects of film heterogeneities on the optical density (OD) measurements. RGB transmission images were obtained with an Epson 10000XL flatbed scanner, and calibration curves relating OD and dose using a rational function were determined for each colour channel and at each energy using a non-linear least square minimization method. Differences found between the 6 MV calibration curve and those for the lower energy sources are large enough that 6 MV beams should not be used to calibrate film for low-energy sources. However, differences between the 75 kVp and I-125 calibration curves were quite small; indicating that 75 kVp is a good choice. Compared with I-125 irradiation, this gives the advantages of lower type B uncertainties and markedly reduced irradiation time. To obtain high accuracy calibration for the dose range up to 35 Gy, two-segment piece-wise fitting was required. This yielded absolute dose measurement accuracy above 1 Gy of ∼2% for 75 kVp and ∼5% for I-125 seed exposures.

60 APPLIED LIFE SCIENCES↗

Knowledge-informed deep learning for hydrological model calibration: an application to Coal Creek Watershed in Colorado

Abstract. Deep learning (DL)-assisted inverse mapping has shown promise in hydrological model calibration by directly estimating parameters from observations. However, the increasing computational demand for running the state-of-the-art hydrological model limits sufficient ensemble runs for its calibration. In this work, we present a novel knowledge-informed deep learning method that can efficiently conduct the calibration using a few hundred realizations. The method involves two steps. First, we determine decisive model parameters from a complete parameter set based on the mutual information (MI) between model responses and each parameter computed by a limited number of realizations (∼50). Second, we perform more ensemble runs (e.g., several hundred) to generate the training sets for the inverse mapping, which selects informative model responses for estimating each parameter using MI-based parameter sensitivity. We applied this new DL-based method to calibrate a process-based integrated hydrological model, the Advanced Terrestrial Simulator (ATS), at Coal Creek Watershed, CO. The calibration is performed against observed stream discharge (Q) and remotely sensed evapotranspiration (ET) from the water year 2017 to 2019. Preliminary MI analysis on 50 realizations resulted in a down-selection of 7 out of 14 ATS model parameters. Then, we performed a complete MI analysis on 396 realizations and constructed the inverse mapping from informative responses to each of the selected parameters using a deep neural network. Compared with calibration using observations covering all time steps, the new inverse mapping improves parameter estimations, thus enhancing the performance of ATS forward model runs. The Nash–Sutcliffe efficiency (NSE) of streamflow predictions increases from 0.53 to 0.8 when calibrating against Q alone. Using ET observations, on the other hand, does not show much improvement on the performance of ATS modeling mainly due to both the uncertainty of the remotely sensed product and the insufficient coverage of the model ET ensemble in capturing the observation. By using observed Q only, we further performed a multiyear analysis and show that Q is best simulated (NSE > 0.8) by including in the calibration the dry-year flow dynamics that show more sensitivity to subsurface characteristics than the other wet years. Moreover, when continuing the forward runs till the end of 2021, the calibrated models show similar simulation performances during this evaluation period as the calibration period, demonstrating the ability of the estimated parameters in capturing climate sensitivity. Our success highlights the importance of leveraging data-driven knowledge in DL-assisted hydrological model calibration.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Multivariate Experimental Data Using A Simplified Regression Model Search Algorithm

A new regression model search algorithm was developed that may be applied to both general multivariate experimental data sets and wind tunnel strain-gage balance calibration data. The algorithm is a simplified version of a more complex algorithm that was originally developed for the NASA Ames Balance Calibration Laboratory. The new algorithm performs regression model term reduction to prevent overfitting of data. It has the advantage that it needs only about one tenth of the original algorithm's CPU time for the completion of a regression model search. In addition, extensive testing showed that the prediction accuracy of math models obtained from the simplified algorithm is similar to the prediction accuracy of math models obtained from the original algorithm. The simplified algorithm, however, cannot guarantee that search constraints related to a set of statistical quality requirements are always satisfied in the optimized regression model. Therefore, the simplified algorithm is not intended to replace the original algorithm. Instead, it may be used to generate an alternate optimized regression model of experimental data whenever the application of the original search algorithm fails or requires too much CPU time. Data from a machine calibration of NASA's MK40 force balance is used to illustrate the application of the new search algorithm.

Ulbrich, Norbert M.↗

INL CRMO XRF Special Report No. 3: INL CRMO XRF Calibration Methods for the Analysis of Ceramics and Brick

This report details the analytical methods used by the Idaho National Laboratory Cultural Resource Management Office to characterize ceramic and brick artifacts using X-ray fluorescence spectrometry. More specifically, this report provides details on instrumentation, analysis times, and matrix-specific calibration protocols for ceramic materials. Calibration curves were developed to adjust raw instrumental output for 13 elements using a suite of reference standards made from historic brick borrowed from the Yale Peabody Museum. Calibration curves were validated by plotting predicted values against published reference values for the calibration set as well as a certified soil reference standard (SRM 2711a).

36 MATERIALS SCIENCE↗

Inflight calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Green, Robert O.↗

Inflight Calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Chrien, Tom↗

Mid-Latitude Temperatures at 87 km: Results From Multi-Instrument Fourier Analysis

Using a novel Fourier fitting method we combine two years of mid-latitude temperature measurements at 87 km from the High Resolution Doppler Imager, the Colorado State University lidar, and the Peach Mountain Interferometer. After accounting for calibration bias, significant local-time variations on the order of 10 K were observed. Stationary planetary waves with amplitudes up to 10 K were observed during winter, with weaker wave amplitudes occurring during other seasons. Because of calibration biases among these instruments, we could estimate the annual mean temperature to no better than 193.5 plus or minus 8.5 K.

FOURIER ANALYSIS↗

JMR Noise Diode Stability and Recalibration Methodology after Three Years On-Orbit

The Jason Microwave Radiometer (JMR) is included on the Jason-1 ocean altimeter satellite to measure the wet tropospheric path delay (PD) experienced by the radar altimeter signal. JMR is nadir pointing and measures the radiometric brightness temperature (T(sub B)) at 18.7, 23.8 and 34.0 GHz. JMR is a Dicke radiometer and it is the first radiometer to be flown in space that uses noise diodes for calibration. Therefore, monitoring the long term stability of the noise diodes is essential. Each channel has three redundant noise diodes which are individually coupled into the antenna signal to provide an estimate of the gain. Two significant jumps in the JMR path delays, relative to ground truth, were observed around 300 and 700 days into the mission. Slow drifts in the retrieved products were also evident over the entire mission. During a recalibration effort, it was determined that a single set of calibration coefficients was not able to remove the calibration jumps and drifts, suggesting that there was a change in the hardware and time dependent coefficients would be required. To facilitate the derivation of time dependent coefficients, an optimal estimation based calibration system was developed which iteratively determines that set of calibration coefficients which minimize the RMS difference between the JMR TBs and on-Earth hot and cold absolute references. This optimal calibration algorithm was used to fine tune the front end path loss coefficients and derive a time series of the JMR noise diode brightness temperatures for each of the nine diodes. Jumps and drifts, on the order of 1% to 2%, are observed among the noise diodes in the first three years on-orbit.

Jason 1↗

Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal renormalization of multiscale systems

While model order reduction is a promising approach in dealing with multi-scale time-dependent systems that are too large or too expensive to simulate for long times, the resulting reduced order models can suffer from instabilities. We have recently developed a time-dependent renormalization approach to stabilize such reduced models. In the current work, we extend this framework by introducing a parameter that controls the time-decay of the memory of such models and optimally selecting this parameter based on limited fully resolved simulations. First, we demonstrate our framework on the inviscid Burgers equation whose solution develops a finite-time singularity. Our renormalized reduced order models are stable and accurate for long times while using for their calibration only data from a full order simulation before the occurrence of the singularity. Furthermore, we apply this framework to the 3D Euler equations of incompressible fluid flow, where the problem of finite-time singularity formation is still open and where brute force simulation is only feasible for short times. Our approach allows us to obtain for the first time a perturbatively renormalizable model which is stable for long times and includes all the complex effects present in the 3D Euler dynamics. We find that, in each application, the renormalization coefficients display algebraic decay with increasing resolution, and that the parameter which controls the time-decay of the memory is problem-dependent.

Price, Jacob↗

Inter-Calibrating the CERES SW Instrument Fluxes Using Deep Convective Clouds(DCC) Within the Same Sun-Synchronous Orbit

The NASA CERES EBAF product provides the scientific community observed TOA fluxes to monitor the Earth’s energy imbalance and to validate climate models. To provide a seamless EBAF 24-year record, the CERES instrument calibration must be stable and consistent across satellite records. Once the Terra and Aqua spacecraft are decommissioned at the end of 2025, the CERES project will rely on CERES instrument observations on the SNPP and NOAA-20 1:30 PM sun-synchronous orbits. The SNPP and NOAA-20 satellite orbit placement will prevent any time matched observations for inter-calibration efforts. The future Libera instrument, which will continue the CERES record and scheduled for launch in 2028 onboard the NOAA-22 satellite, will also need to be inter-calibrated without the aid of time-matched observations. Deep convective clouds (DCC) are the most Lambertian, brightest, tropical Earth invariant targets located at the tropopause making them ideal to radiometrically scale the CERES SW observed radiance to a common reference. The SNPP, NOAA-20 and future NOAA-22 satellites are in the same 16-day repeatable orbits, allowing the DCC targets to be observed with the same angular configuration. The empirically derived SNPP CERES SW channel Bidirectional Reflectance Distribution Function (BRDF) can be easily be applied to the NOAA-20 CERES SW channel radiances since they observe the nearly the same DCC systems. The DCC BRDF corrected radiances are analyzed collectively into radiance probability distribution functions (PDF). By comparing the PDF statistics, the SNPP and NOAA-20 CERES SW channel can be inter-calibrated. The inter-calibration coefficients are validated with the CERES instrument calibration team coefficients to optimize the methodology.

David Doelling↗

Digital Calibration of TR Modules for Real-Tme Digital Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable a new architecture, which is the baseline for the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). This new instrument concept requires new methods for calibrating multiple simultaneous channels. The calibration of current state-of-the-art Electronically Steered Arrays typically involves pre-flight TR (Transmit/Receive) module characterization over temperature, and in-flight correction based on measured temperatures. This method ignores the effects of element aging and any drifts unrelated to temperature. We are developing new digital calibration of digital beamforming arrays, which helps to reduce development time, risk and cost. Precision calibrated TR modules enable real-time beamforming architectures by accurately tracking modules' characteristics through closed-loop digital calibration, which tracks systematic changes regardless of temperature. The benefit of this effort is that it would enable a new, lightweight radar architecture, with on-board digital beamforming. This provides significantly larger swath coverage than conventional SAR architectures

Hoffman, James Patrick↗

High accuracy wavelength calibration for a scanning visible spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies {<=}0.2 A. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of {approx}0.25 A has been demonstrated. With the addition of a high resolution (0.075 arc sec) optical encoder on the grating stage, greater precision ({approx}0.005 A) is possible, allowing absolute velocity measurements within {approx}0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Synoptic VLBI Technique for Localizing Nonrepeating Fast Radio Bursts with CHIME/FRB

We demonstrate the blind interferometric detection and localization of two fast radio bursts (FRBs) with subarcminute precision on the 400 m baseline between the Canadian Hydrogen Intensity Mapping Experiment (CHIME) and the CHIME Pathfinder. In the same spirit as Very Long Baseline Interferometry (VLBI), the telescopes were synchronized to separate clocks, and the channelized voltage (herein referred to as baseband) data were saved to a disk with correlation performed offline. The simultaneous wide field of view and high sensitivity required for blind FRB searches implies a high data rate—6.5 terabits per second (Tb/s) for CHIME and 0.8 Tb s{sup −1} for the Pathfinder. Since such high data rates cannot be continuously saved, we buffer data from both telescopes locally in memory for ≈40 s, and write to the disk upon receipt of a low-latency trigger from the CHIME Fast Radio Burst Instrument (CHIME/FRB). The ≈200 deg{sup 2} field of view of the two telescopes allows us to use in-field calibrators to synchronize the two telescopes without needing either separate calibrator observations or an atomic timing standard. In addition to our FRB observations, we analyze bright single pulses from the pulsars B0329+54 and B0355+54 to characterize systematic localization errors. Our results demonstrate the successful implementation of key software, triggering, and calibration challenges for CHIME/FRB Outriggers: cylindrical VLBI outrigger telescopes which, along with the CHIME telescope, will localize thousands of single FRB events with sufficient precision to unambiguously associate a host galaxy with each burst.

47 OTHER INSTRUMENTATION↗

Method for Ground-to-Space Laser Calibration System

The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.

Lukashin, Constantine↗

Method for Ground-to-Satellite Laser Calibration System

The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.

Lukashin, Constantine↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Hydrogen sensing in different hydrogen-carrying gases using composites of PdSnO 2 and halloysite nanotubes

Here, in this work, we developed composites of palladium-decorated tin dioxide (PdSnO 2 ) and halloysite nanotubes (HNTs) by adding different amounts of HNTs as additives into PdSnO 2 , and investigated how the different amounts of HNTs in the composites and the different hydrogen (H 2 ) carrying gases (air and helium (He)) could affect the H 2 sensing performance of such composites (PdSnO 2 -HNT). Through the sensing-performance characterization using H 2 carried by air, it was found that PdSnO 2 with an appropriate small amount of HNTs (i.e., 2 % of PdSnO 2 mass) can improve the sensing performance with respect to limit of detection (LOD) and response/recovery time. Further, the optimal PdSnO2-HNT composite as a sensor was tested to detect H 2 in He. The testing results indicated that the composite can detect H 2 in He, but its performance parameters (i.e., the profile of calibration curve, LOD, and response time) are different from those of such a sensor in detecting H 2 in air. Moreover, the composite still presented better sensing performance than PdSnO 2 without HNTs in detecting H 2 in He. Possible reasons for the effects of HNT and H 2 -carrying gas on the sensing performance of PdSnO 2 -HNT-based sensors were discussed. We believe that this study provides valuable insights into the functionality and the adaptability of PdSnO 2 -HNT-based H 2 sensors in diverse operational conditions.

36 MATERIALS SCIENCE↗