Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Versatile, reprogrammable area pixel array detector for time-resolved synchrotron x-ray applications

The final technical report for DOE grant DE-SC0004079 is presented. The goal of the grant was to perform research, development and application of novel imaging x-ray detectors so as to effectively utilize the high intensity and brightness of the national synchrotron radiation facilities to enable previously unfeasible time-resolved x-ray research. The report summarizes the development of the resultant imaging x-ray detectors. Two types of detector platforms were developed: The first is a detector platform (called a Mixed-Mode Pixel Array Detector, or MM-PAD) that can image continuously at over a thousand images per second while maintaining high efficiency for wide dynamic range signals ranging from 1 to hundreds of millions of x-rays per pixel per image. Research on an even higher dynamic range variant is also described. The second detector platform (called the Keck Pixel Array Detector) is capable of acquiring a burst of x-ray images at a rate of millions of images per second.

47 OTHER INSTRUMENTATION↗

Imaging electron-density fluctuations by multidimensional X-ray photon-coincidence diffraction

The ultrafast spontaneous electron-density fluctuation dynamics in molecules is studied theoretically by off-resonant multiple X-ray diffraction events. The time- and wavevector-resolved photon-coincidence signals give an image of electron-density fluctuations expressed through the four-point correlation function of the charge density in momentum space. A Fourier transform of the signal provides a real-space image of the multipoint charge-density correlation functions, which reveal snapshots of the evolving electron density in between the diffraction events. The proposed technique is illustrated by ab initio simulations of the momentum- and real-space inelastic scattering signals from a linear cyanotetracetylene molecule.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic Exploding Foil Initiator Imaging at the Advanced Photon Source

Recent advances in diagnostics coupled with synchrotron sources have allowed the in-situ investigation of exploding foil initiators (EFI) during flight. Herein, we present the first images of EFIs during flight utilizing x-ray phase contrast imaging at the Advanced Photon Source (APS) located in Argonne National Laboratory. These images have provided the DOE/DoD community with unprecedented images resolving details on the micron scale of the flyer formation, plasma instabilities and in-flight characteristics along with the subsequent interaction with high explosives on the nanosecond time scale. Phase contrast imaging has allowed the ability to make dynamic measurements on the length and time scale necessary to resolve initiator function and provide insight to key design parameters. These efforts have also probed the fundamental physics at “burst” to better understand what burst means in a physical sense, rather than the traditional understanding of burst as a peak in voltage and increase in resistance. This fundamental understanding has led to increased knowledge on the mechanisms of burst and has allowed us to improve our predictive capability through magnetohydrodnamic modeling. This manuscript presents results from several EFI designs along with a look to the future for upcoming work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray radiographic expansion measurements of isochorically heated thin wire targets

Solid density matter at temperatures ranging from 150 eV to <5 eV has been created by irradiating thin wire targets with high-energy laser pulses at intensities ≈10{sup 18}W/cm{sup 2}. Energy deposition and transport of the laser-produced fast electrons are inferred from spatially resolved K{sub α}-spectroscopy. Time resolved x-ray radiography is employed to image the target mass density up to solid density and proves isochoric heating. The subsequent hydrodynamic evolution of the target is observed for up to 3 ns and is compared to radiation-hydrodynamic simulations. At distances of several hundred micrometers from the laser interaction region, where temperatures of 5–20 eV and small temperature gradients are found, the hydrodynamic evolution of the wire is a near axially symmetric isentropic expansion, and good agreement between simulations and radiography data confirms heating of the wire over hundreds of micrometers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved Polarimetry of the Superluminous SN 2015bn with the Nordic Optical Telescope

We present imaging polarimetry of the superluminous supernova SN 2015bn, obtained over nine epochs between −20 and +46 days with the Nordic Optical Telescope. This was a nearby, slowly evolving Type I superluminous supernova that has been studied extensively and for which two epochs of spectropolarimetry are also available. Based on field stars, we determine the interstellar polarization in the Galaxy to be negligible. The polarization of SN 2015bn shows a statistically significant increase during the last epochs, confirming previous findings. Our well-sampled imaging polarimetry series allows us to determine that this increase (from ∼0.54% to ≳1.10%) coincides in time with rapid changes that took place in the optical spectrum. We conclude that the supernova underwent a “phase transition” at around +20 days, when the photospheric emission shifted from an outer layer, dominated by natal C and O, to a more aspherical inner core, dominated by freshly nucleosynthesized material. This two-layered model might account for the characteristic appearance and properties of Type I superluminous supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

100-kHz Interferometric Rayleigh Scattering Flow Diagnostics at 266 nm

Interferometric Rayleigh scattering (IRS) is a laser-based technique capable of spatially and temporally resolved measurement of gas velocity and temperature in unseeded gaseous flows. In the present embodiment of the technique, IRS is performed at 266 nm for the first time. IRS at 266 nm is potentially much less susceptible to interferences from particles and other stray light sources. A pulse-burst laser and high-speed camera provided image rates of 100 kHz, allowing simultaneous space- and time-resolved measurement in high speed flow at multiple points along a line. The use of 266 nm excitation and detection is compared with prior work that used 532 nm. New experimental interferogram modelling and fitting techniques for single and multi-velocity-component IRS were demonstrated in a study of the spatial and temporal variation of the flow along a line through a supersonic jet. Single component velocity and temperature measurements using 266 nm were successfully made and compared with prior 532 nm results. Two-component velocity measurements at 266 nm, using the reflected image method, were compared to single-component measurements.

Andrew D Cutler↗

Proton radiography and fluoroscopy of lung tumors: A Monte Carlo study using patient-specific 4DCT phantoms

Purpose: Monte Carlo methods are used to simulate and optimize a time-resolved proton range telescope (TRRT) in localization of intrafractional and interfractional motions of lung tumor and in quantification of proton range variations. Methods: The Monte Carlo N-Particle eXtended (MCNPX) code with a particle tracking feature was employed to evaluate the TRRT performance, especially in visualizing and quantifying proton range variations during respiration. Protons of 230 MeV were tracked one by one as they pass through position detectors, patient 4DCT phantom, and finally scintillator detectors that measured residual ranges. The energy response of the scintillator telescope was investigated. Mass density and elemental composition of tissues were defined for 4DCT data. Results: Proton water equivalent length (WEL) was deduced by a reconstruction algorithm that incorporates linear proton track and lateral spatial discrimination to improve the image quality. 4DCT data for three patients were used to visualize and measure tumor motion and WEL variations. The tumor trajectories extracted from the WEL map were found to be within {approx}1 mm agreement with direct 4DCT measurement. Quantitative WEL variation studies showed that the proton radiograph is a good representation of WEL changes from entrance to distal of the target. Conclusions: MCNPX simulation results showed that TRRT can accurately track the motion of the tumor and detect the WEL variations. Image quality was optimized by choosing proton energy, testing parameters of image reconstruction algorithm, and comparing to ground truth 4DCT. The future study will demonstrate the feasibility of using the time resolved proton radiography as an imaging tool for proton treatments of lung tumors.

60 APPLIED LIFE SCIENCES↗

Detecting coherent core-hole wave-packet dynamics in N 2 by time- and angle-resolved inner-shell photoelectron spectroscopy

Here, we introduce an imaging technique to follow core-hole wave-packet oscillations in the nitrogen molecule. In this scheme, an attosecond x-ray pulse core-ionizes the nitrogen molecule and a subsequent attosecond x-ray pulse probes the evolution of the electron dynamics. We can image the oscillation of the core-hole between the two atomic sites by measuring the angular correlation between photoelectrons. Analytical relations for the angular correlation are derived based on the plane-wave approximation for the photoelectron wave function. We confirm these results with a scattering calculation for the photoelectron wave function. The feasibility of the experimental realization of this scheme is discussed in light of current and future capabilities of x-ray free-electron lasers.

74 ATOMIC AND MOLECULAR PHYSICS↗

RHESSI TESTS OF QUASI-THERMAL GAMMA-RAY BURST SPECTRAL MODELS

Prompt gamma-ray burst (GRB) spectra evolve on short timescales, suggesting that time-resolved spectral fits may help diagnose the still unknown prompt emission mechanism. We use broadband gamma-ray data from the Ramaty High-Energy Solar Spectroscopic Imager spacecraft to test quasi-thermal models with high signal-to-noise time-resolved spectra of nine bright GRBs. In contrast to results reported in more narrow energy bands, the quality of the fits of quasi-thermal models is poor in relation to fits of the phenomenological Band function. Moreover, the best-fit parameters for the simplest quasi-thermal model, a blackbody plus a nonthermal power law, show significant dependence on the fit band. Models that replace the power law with more complicated nonthermal functions are not robust for the data considered here and decrease the physical relevance of the fit blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT

Dosimetric properties of an amorphous-silicon electronic portal imaging device (EPID) operated in a real-time acquisition mode were investigated. This mode will be essential for time-resolved dose verification of dynamic (sliding window) intensity modulated radiation therapy (IMRT) and intensity modulated arc radiation therapy (arc-IMRT). The EPID was used in continuous acquisition mode (i.e., ''cine'' mode) where individual sequential image frames are acquired in real time. The properties studied include dose linearity, reproducibility of response, and image stability. Results of using the continuous acquisition mode with several example treatments including dynamic IMRT, arc treatment, and single-arc-IMRT are compared to results using the well-studied integrated acquisition mode (i.e., ''frame averaging'' or ''IMRT'' mode). Real-time EPID response was also compared to real-time ion-chamber data for selected points in the deliveries. The example treatment deliveries in both continuous and integrated acquisition modes were converted to arbitrary EPID dose units via a calibration field. The summation of all acquired continuous mode images was compared using percentage dose difference to the single image acquired in the integrated mode using in-field pixels only (defined as those pixels >10% of maximum, in-field signal). Using the continuous acquisition mode, the EPID response was not linear with dose. It was found that the continuous mode dose response corresponded approximately to dropping one image per acquisition session. Reproducibility of EPID response to low monitor units (MUs) was found to be poor but greatly improved with increasing MU. Open field profiles were found to be stable in the cross-plane direction but required several frames to become stable in the in-plane direction. However, both of these issues are clinically insignificant due to arc-IMRT deliveries requiring relatively large monitor units (>100 MU). Analysis of the five IMRT, arc, and arc-IMRT tests revealed that all examples compared to within 2% of maximum dose for more than 95% of in-field pixels. The continuous acquisition mode is suited to time-resolved dosimetry applications including arc-IMRT and dynamic IMRT, giving comparable dose results to the well-studied integrated acquisition mode, although caution should be used in low MU applications. Time-resolved EPID dose information also compared well to time-resolved ion-chamber measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the Wendelstein 7-X (W7-X) stellarator. Both systems combined give a comprehensive overview of overall fluctuation levels, spectral properties such as their distribution in frequency and wavenumber space as well as their spatial distribution. These tools are used to assess changes in density turbulence in three representative discharges that transition into stable divertor detachment by different strategies (impurity seeding, density ramping and power starvation). Several general trends are identified when the radiated power fraction is systematically increased: In the plasma edge, the line emission observed by GPI shifts radially inward with a drop in electron temperature, and normalized intensity fluctuation profiles follow this inward shift. Skewness and kurtosis of these edge fluctuations are reduced, indicating a reduction of large intermittent transport events, and poloidal phase velocities decrease in magnitude. These observations are consistent with a reduced power input into the plasma edge and a general reduction of turbulent activity. Core density fluctuation levels remain nearly constant in the impurity seeding scenario, indicating that detachment does not significantly impact turbulence there. However, a strong reduction in the dominant outboard fluctuation phase velocity is observed that deviates from the previous interpretation of neoclassical radial electric field changes, showing that the core plasma is not completely unaffected. In the density ramp and power starvation scenarios, undesirable and irregular large-scale events arise clearly in both diagnostic systems as the radiative fraction is increased. Impurity seeding therefore seems to be a promising strategy on W7-X to achieve detachment without significantly altering core turbulence, especially when targeting a specific operating point in core density and heating power.

Wendelstein 7-X↗

THE RADIO CONTINUUM STRUCTURE OF CENTAURUS A AT 1.4 GHz

A 45 deg{sup 2} radio continuum imaging campaign of the nearest radio galaxy, Centaurus A, is reported. Using the Australia Telescope Compact Array and the Parkes 64 m radio telescope at 1.4 GHz, the spatial resolution of the resultant image is {approx}600 pc ({approx}50''), resolving the {approx}>500 kpc giant radio lobes with approximately five times better physical resolution compared to any previous image, and making this the most detailed radio continuum image of any radio galaxy to date. In this paper, we present these new data and discuss briefly some of the most interesting morphological features that we have discovered in the images. The two giant outer lobes are highly structured and considerably distinct. The southern part of the giant northern lobe naturally extends out from the northern middle lobe with uniformly north-streaming emission. The well known northern loop is resolved into a series of semi-regular shells with a spacing of approximately 25 kpc. The northern part of the giant northern lobe also contains identifiable filaments and partial ring structures. As seen in previous single-dish images at lower angular resolution, the giant southern lobe is not physically connected to the core at radio wavelengths. Almost the entirety of the giant southern lobe is resolved into a largely chaotic and mottled structure which appears considerably different (morphologically) to the diffuse regularity of the northern lobe. We report the discovery of a vertex and a vortex near the western boundary of the southern lobe, two striking, high surface brightness features that are named based on their morphology and not their dynamics (which are presently unknown). The vortex and vertex are modeled as reaccelerated lobe emission due to shocks from the active galactic nucleus itself or from the passage of a dwarf elliptical galaxy through the lobe. Preliminary polarimetric and spectral index studies support a plasma reacceleration model and could explain the origin of the Faraday rotation structure detected in the southern lobe. In addition, there are a series of low surface brightness wisps detected around the edges of both the giant lobes.

79 ASTRONOMY AND ASTROPHYSICS↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

Phase transitions in freeze-dried systems - quantification using in situ synchrotron X-ray diffractometry

The purpose is: (1) To develop a synchrotron X-ray diffraction (SXRD) method to monitor phase transitions during the entire freeze-drying cycle. Aqueous sodium phosphate buffered glycine solutions with initial glycine to buffer molar ratios of 1:3 (17:50 mM), 1:1 (50 mM) and 3:1 were utilized as model systems. (2) To investigate the effect of initial solute concentration on the crystallization of glycine and phosphate buffer salt during lyophilization. Phosphate buffered glycine solutions were placed in a custom-designed sample cell for freeze-drying. The sample cell, covered with a stainless steel dome with a beryllium window, was placed on a stage capable of controlled cooling and vacuum drying. The samples were cooled to -50 C and annealed at -20 C. They underwent primary drying at -25 C under vacuum until ice sublimation was complete and secondary drying from 0 to 25 C. At different stages of the freeze-drying cycle, the samples were periodically exposed to synchrotron X-ray radiation. An image plate detector was used to obtain time-resolved two-dimensional SXRD patterns. The ice, {beta}-glycine and DHPD phases were identified based on their unique X-ray peaks. When the solutions were cooled and annealed, ice formation was followed by crystallization of disodium hydrogen phosphate dodecahydrate (DHPD). In the primary drying stage, a significant increase in DHPD crystallization followed by incomplete dehydration to amorphous disodium hydrogen phosphate was evident. Complete dehydration of DHPD occurred during secondary drying. Glycine crystallization was inhibited throughout freeze-drying when the initial buffer concentration (1:3 glycine to buffer) was higher than that of glycine. A high-intensity X-ray diffraction method was developed to monitor the phase transitions during the entire freeze-drying cycle. The high sensitivity of SXRD allowed us to monitor all the crystalline phases simultaneously. While DHPD crystallizes in frozen solution, it dehydrates incompletely during primary drying and completely during secondary drying. The impact of initial solute concentration on the phase composition during the entire freeze-drying cycle was quantified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase correlation imaging of unlabeled cell dynamics

We present phase correlation imaging (PCI) as a novel approach to study cell dynamics in a spatially-resolved manner. PCI relies on quantitative phase imaging time-lapse data and, as such, functions in label-free mode, without the limitations associated with exogenous markers. The correlation time map outputted in PCI informs on the dynamics of the intracellular mass transport. Specifically, we show that PCI can extract quantitatively the diffusion coefficient map associated with live cells, as well as standard Brownian particles. Due to its high sensitivity to mass transport, PCI can be applied to studying the integrity of actin polymerization dynamics. Our results indicate that the cyto-D treatment blocking the actin polymerization has a dominant effect at the large spatial scales, in the region surrounding the cell. We found that PCI can distinguish between senescent and quiescent cells, which is extremely difficult without using specific markers currently. We anticipate that PCI will be used alongside established, fluorescence-based techniques to enable valuable new studies of cell function.

42 ENGINEERING↗

Radiative Properties of Implosions of Stainless Steel Wire Arrays with Application to Astrophysics

Experiments with different stainless steel (SS) wire loads were performed on the 1 MA Zebra Z-pinch generator at University of Nevada, Reno. The wire array loads consisted of 7.6 {mu}m SS wires and had 10 wires for the planar wire array with an interwire gap of 1 mm and 8 wires for the cylindrical wire array of a 16 mm diameter. In addition, a single-wire experiment with a 25 {mu}m SS wire was carried out. The different wire loads were used to provide a broader spectrum of plasma conditions. Time-integrated and time-gated x-ray images, as well as time-integrated, spatially-resolved and spatially-integrated x-ray spectra, were collected and analyzed. Both K-shell and L-shell radiation were recorded using LiF and KAP crystal spectrometers, respectively. Non-LTE kinetic models of Fe and Ni are employed to derive plasma parameters. For axially resolved L-shell spectra, the resulting electron temperatures are between 230 and 300 eV (higher near the cathode) and electron densities vary from 10{sup 19} to 10{sup 20} cm{sup -3} dependent on the load. The advantage of using Z-pinch plasmas for astrophysical applications is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DIFFRACTION-LIMITED VISIBLE LIGHT IMAGES OF ORION TRAPEZIUM CLUSTER WITH THE MAGELLAN ADAPTIVE SECONDARY ADAPTIVE OPTICS SYSTEM (MagAO)

We utilized the new high-order (250-378 mode) Magellan Adaptive Optics system (MagAO) to obtain very high spatial resolution observations in ''visible light'' with MagAO's VisAO CCD camera. In the good-median seeing conditions of Magellan (0.''5-0.''7), we find MagAO delivers individual short exposure images as good as 19 mas optical resolution. Due to telescope vibrations, long exposure (60 s) r' (0.63 {mu}m) images are slightly coarser at FWHM = 23-29 mas (Strehl {approx}28%) with bright (R < 9 mag) guide stars. These are the highest resolution filled-aperture images published to date. Images of the young ({approx}1 Myr) Orion Trapezium {theta}{sup 1} Ori A, B, and C cluster members were obtained with VisAO. In particular, the 32 mas binary {theta}{sup 1} Ori C{sub 1} C{sub 2} was easily resolved in non-interferometric images for the first time. The relative positions of the bright trapezium binary stars were measured with {approx}0.6-5 mas accuracy. We are now sensitive to relative proper motions of just {approx}0.2 mas yr{sup -1} ({approx}0.4 km s{sup -1} at 414 pc)-this is a {approx}2-10 Multiplication-Sign improvement in orbital velocity accuracy compared to previous efforts. For the first time, we see clear motion of the barycenter of {theta}{sup 1} Ori B{sub 2} B{sub 3} about {theta}{sup 1} Ori B{sub 1}. All five members of the {theta}{sup 1} Ori B system appear likely to be a gravitationally bound ''mini cluster'', but we find that not all the orbits can be both circular and co-planar. The lowest mass member of the {theta}{sup 1} Ori B system (B{sub 4}; mass {approx}0.2 M{sub Sun }) has a very clearly detected motion (at 4.1 {+-} 1.3 km s{sup -1}; correlation = 99.9%) w.r.t. B{sub 1}. Previous work has suggested that B{sub 4} and B{sub 3} are on long-term unstable orbits and will be ejected from this ''mini cluster''. However, our new ''baseline'' model of the {theta}{sup 1} Ori B system suggests a more hierarchical system than previously thought, and so the ejection of B{sub 4} may not occur for many orbits, and B{sub 3} may be stable against ejection in the long-term. This ''ejection'' process of the lowest mass member of a ''mini cluster'' could play a major role in the formation of low-mass stars and brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗