Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total Number”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Identification of the feeding arteries of hepatocellular carcinomas by performing dual arterial phase CT during pre-transarterial chemoembolization angiography

Purpose: This study evaluated the usefulness of performing dual arterial phase computed tomography (CT) during pre-transarterial chemoembolization (TACE) angiography for identifying the feeding arteries of hepatocellular carcinomas (HCC). Materials and methods: Dual arterial phase CT was performed during pre-TACE angiography in 73 patients with 139 HCC. Ten HCC underwent this procedure twice, so the total number of examined HCC was 149. Early and late arterial phase images were obtained 6 seconds after injection of an iodinated contrast material serially during a single breath-hold. The feeding artery was defined as the branch of the hepatic artery that was connected to the enhanced areas of the tumor. For HCC that could not be visualized on the early arterial phase images, fusion images superimposing the early and late arterial phase images were constructed. Furthermore, technical success defined as successful catheterization of the subsegmental or more distal feeding artery was evaluated. Results: The feeding artery was correctly identified on dual arterial phase CT in 146 of the 149 tumors (98.0%). In two HCC, the feeding arteries could not be identified due to severe motion artifacts, and in one, due to the presence of anastomosis between the right and left hepatic arteries. Catheterization of the subsegmental feeding artery was successful in all TACE procedures (technical success rate: 100%). Conclusion: Performing dual arterial phase CT during angiography appears to be useful for identifying the feeding arteries of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization

Purpose: We evaluated the effects of the combination of Tirapazamine (TPZ), activated preferentially under hypoxic conditions, and gelatin microspheres (GMS) on the tumor growth ratio in rabbits. Methods: We assigned 20 liver tumor-bearing Japanese white rabbits to 4 equal groups. Group 1 received 1 ml of saline intra-arterially (i.a.) and 20 ml of saline intraperitoneally (i.p.; saline group). Group 2 was injected with GMS i.a. and 20 ml saline i.p. (GMS group). Group 3 received 1 ml of saline i.a. and 300 mg/m{sup 2} of TPZ i.p. (TPZ group), and group 4 was treated with GMS i.a. and 300 mg/m{sup 2} of TPZ i.p. (GMS + TPZ group). The infusion of GMS was stopped when the blood flow stagnated. Before and 7 days after treatment, the liver tumor volumes were measured as the total number of pixels on 0.3Tesla (T) magnetic resonance imaging (MRI) scans. Results: The tumor growth ratio (mean {+-} standard deviation) of the saline, GMS, TPZ, and GMS + TPZ groups was 519.15 {+-} 93.78, 279.24 {+-} 91.83, 369.78 {+-} 95.73, and 119.87 {+-} 17.62, respectively. The difference between the GMS + TPZ group and the other groups was statistically significant (P < 0.05). Conclusions: Our results show that the combination of TPZ i.p. and GMS i.a. enhanced the antitumor effect of TPZ. This procedure may represent a new alternative treatment for patients with hepatic cell carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is There a Role for Empiric Gastroduodenal Artery Embolization in the Management of Patients with Active Upper GI Hemorrhage?

PurposeTo assess the relative efficacy of empiric gastroduodenal artery (GDA) embolization in reducing recurrent hemorrhage compared to image-guided targeted embolization.MethodsData were retrospectively collected for consecutive patients who had catheter angiography for major upper gastrointestinal hemorrhage from May 2008 to November 2010 (n = 40). The total number of cases were divided into two main groups according to angiographic findings: those that demonstrated a site of hemorrhage on catheter angiography (group 1, n = 13), and those where the site of hemorrhage was not identified on catheter angiography (group 2, n = 27). Group 2 was then further divided into patients who received empiric embolization (group 2a, n = 20) and those who had no embolization performed after angiography (group 2b, n = 7).ResultsThe technical and clinical success rates for embolization in groups 1 and 2a were, respectively, 100 vs. 95 %, and 85 vs. 80 %. There was no statistical significance in the recurrent hemorrhage rate, reintervention rate, or 30 day mortality between targeted and empiric embolization groups. There were no complications attributed to embolization within this study cohort.ConclusionCases of duodenal-related major upper gastrointestinal hemorrhage where no embolization is performed have poor outcome. Empiric embolization of the GDA in patients with major upper gastrointestinal hemorrhage refractory to endoscopic treatment appears to be a safe and effective treatment, with low reintervention rates and good clinical outcome comparable to patients where the site of hemorrhage is localized and embolized with computed tomographic angiography or catheter angiography and embolized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Hepatic Arterial Injury Related to Percutaneous Transhepatic Portal Intervention

PurposeTo assess the usefulness of transcatheter arterial embolization (TAE) for the hepatic arterial injury related to percutaneous transhepatic portal intervention (PTPI).Materials and MethodsFifty-four patients, 32 males and 22 females with a median age of 68 years (range 43–82 years), underwent PTPI. The procedures consisted of 33 percutaneous transhepatic portal vein embolizations, 19 percutaneous transhepatic variceal embolizations, and 2 percutaneous transhepatic portal venous stent placements. Two patients with gastric varices underwent percutaneous transhepatic variceal embolization twice because of recurrence. Therefore, the total number of procedures was 56. Among them, hepatic arterial injury occurred in 6 PTPIs in 5 patients, and TAE was performed. We assessed technical success, complications related to TAE, and clinical outcome. Technical success was defined as the disappearance of findings due to hepatic arterial injury on digital subtraction angiography.ResultsAs hepatic arterial injuries, 4 extravasations and 2 arterioportal shunts developed. All TAEs were performed successfully. The technical success rate was 100 %. Complication of TAE occurred in 5 of 6 TAEs; 3 were focal liver infarction, not requiring further treatment, and 2 were biloma that required percutaneous drainage. Five TAEs in 4 patients were performed immediately after the PTPI, and these 4 patients were alive. However, one TAE was performed 10 h later, and the patient died due to multiple organ failure 2 months later although TAE was successful.ConclusionTAE is a useful treatment for hepatic arterial injury related to PTPI. However, it should be performed at an early stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Inversion (“flipping”) Rates Among Different Port Designs: A Single-Center Experience

PurposeTo compare incidence of port inversion among different types of implantable venous access devices.Materials and Methods Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated.Results Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7–580).Conclusion The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design.Level of Evidence: Case Series, Level IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Distribution of Centrifuges over Stages in a Cascade for Separating Multicomponent Mixtures of Isotopes

A method of calculating the optimal operating parameters of a centrifuge cascade for separating multicomponent mixtures of isotopes is developed. A computational scheme is proposed for calculating the parameters of a cascade and the distribution of the centrifuges over the stages with a prescribed total number of centrifuges in different variants of optimization. Calculations showing the particulars of optimization and the efficacy of the developed method are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Purification of Regenerated Uranium Hexafluoride by Removal of {sup 232,234}U in a Centrifuge Cascade with Prescribed Concentration of One of the Isotopes {sup 232,234,235}U

Schemes are proposed for purifying regenerated uranium hexafluoride by removal of {sup 232,234}U in an optimal centrifuge cascade with prescribed external concentration of one of the isotopes {sup 232,234,235}U. The cascade is optimized according to the criterion of minimum total number of centrifuges. The purification effect is achieved in the waste flow of the cascade when the feed point is shifted toward the product. The number of steps in the cascade is determined by a preliminary calculation of an R-cascade with different key components. The product parameters and the desirable number of the feed step are picked on the basis of the limit {sup 235}U concentration 5–20%. Calculations showing the possibility of cascades with different degrees of purification by removal of {sup 232,234}U were performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced TEM characterization of oxide nanoparticles in ODS Fe–12Cr–5Al alloys

For oxide nanoparticles present in three oxide-dispersion-strengthened (ODS) Fe–12Cr–5Al alloys containing additions of (1) Y 2 O 3 (125Y), (2) Y 2 O 3 + ZrO 2 (125YZ), and (3) Y 2 O 3 + HfO 2 (125YH), were investigated using transmission and scanning transmission electron microscopy. Furthermore, in all three alloys nano-sized (<3.5 nm) oxide particles distributed uniformly throughout the microstructure were characterized using advanced electron microscopy techniques. In the 125Y alloy, mainly Al 2 O 3 and yttrium–aluminum garnet (YAG) phases (Y 3 Al 5 O 12 ) were present, while in the 125YZ alloy, additional Zr(C,N) precipitates were identified. The 125YH alloy had the most complex precipitation sequence whereby in addition to the YAG and Al 2 O 3 phases, Hf(C,N), Y 2 Hf 2 O 7 , and HfO 2 precipitates were also found. The presence of HfO 2 was mainly due to the incomplete incorporation of HfO 2 powder during mechanical alloying of the 125YH alloy. The alloy having the highest total number density of the oxides, the smallest grain size, and the highest Vickers hardness was the 125YZ alloy indicating, that Y 2 O 3 + ZrO 2 additions had the strongest effect on grain size and tensile properties. Finally, high-temperature mechanical testing will be addressed in the near future, while irradiation studies are underway to investigate the irradiation resistance of these new ODS FeCrAl alloys.

36 MATERIALS SCIENCE↗

First-Principles Investigation of Equiatomic Quaternary Heusler Alloys NbVMnAl and NbFeCrAl and a Discussion of the Generalized Electron-Filling Rule

Plane-wave pseudo-potential methods based on density functional theory are used to study the electronic structures, magnetic, and half-metallic properties of the equiatomic quaternary Heusler alloys NbVMnAl and NbFeCrAl. Calculated results reveal that NbVMnAl and NbFeCrAl alloys are newly designed half-metallic ferrimagnets with a total magnetic moment (M{sub t}) of 2 μ{sub B}. We found that the Slater-Pauling rule, i.e., the relationship between the M{sub t} and the total number of valence electrons (Z{sub t}) of these two alloys was different. For NbVMnAl alloy, it obeys the M{sub t} = |Z{sub t} − 18| rule. For NbFeCrAl, it satisfies the M{sub t} = |Z{sub t} − 24| rule. Also, we observed that the half-metallic band gap (HM-BG) of these two alloys was different. Namely, for one material (NbFeCrAl), it is located in the spin-up channel, and in the other (NbVMnAl), it is located in the spin-down channel. To explain these phenomena, in this work, the generalized electron-filling rule was investigated, and the origin of the HM-BG of NbVMnAl and NbFeCrAl was studied. We hope that our work may provide theoretical guidance in searching for Nb-based equiatomic quaternary Heusler half-metals in the future.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Quaternary Half-Metallic Materials of the Z{sub t} − 28 Rule in LiMgPdSn-Type Heusler Alloys

This paper presents first-principles calculations with the full-potential linearized augmented plane-wave method to study a series of LiMgPdSn-type Heusler alloys. The chemical formula is XX{sup ′}YZ, where X = Fe, Co, or Ni; X{sup ′} = Mn; Y = Cu or Zn; and Z = Si, Al, Ga, or Ge. Eight compounds are found to be half-metallic magnets and obey the Slater–Pauling rule with the total number of valence electrons (Z{sub t}) of 28. The half-metallic band gap in CoMnZnSi compounds reaches its maximum of 0.66 eV. CoMnCuGe and CoMnZnGa can be transformed from a quasi-half-metallic alloy to a half-metallic alloy by employing sufficient compression stress.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First-Principles Investigation of Half-Metallic Ferromagnetism of a New 1:1:1:1 Type Quaternary Heusler Compound YRhTiSi

First-principles theory was applied to study the electronic, magnetic, and half-metallic behaviors of a new Y-based equiatomic quaternary Heusler compound YRhTiSi. We will come to study the physical properties of this compound and find it has the half-metallic nature in the ferromagnetic (FM) state. The total magnetic moment of this compound YRhTiSi is 2 μ{sub B}, which follows the famous Slater-Pauling rule, Mt = Zt − 18, Mt is the total magnetic moment and Zt is the total number of valence electrons. Based on its equilibrium and strained lattice constants, the magnetic and half-metallic behaviors of this compound have been discussed in detail. And we find that the H–M gap and the band gap can be regulated through the effect of uniform strain and the tetragonal deformation. A large H–M gap of 0.48 eV has been found in our work, which is nearly larger than any previous study. Furthermore, the formation and cohesive energies have also been discussed in our work to examine the phase stability of YRhTiSi. This theoretical investigation provides further insight into the application of Y-based compounds as spintronic materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Agglomeration Mechanism of Complex Ti-Al Oxides in Liquid Ferrous Alloys Considering High-Temperature Interfacial Phenomenon

This work presents the agglomeration mechanism of complex Ti-Al oxides in the liquid ferrous alloy. Cluster characteristics were investigated using Al and Ti/Al-complex deoxidation method in lab scale. The time-dependent size distribution, total number per volume, average size, and circularity of the clusters were quantitatively analyzed. Furthermore, high-temperature confocal laser scanning microscopy was utilized to directly observe the cluster formation of Ti-Al oxides. A capillary force model including wettability parameters was applied to compare the agglomeration capabilities of different types of non-metallic inclusions. When a low Ti is added into melt, the agglomeration of TiO{sub x}·FeO liquid inclusions is one of the key factors to decrease the frequency of cluster formation. When the Al is added into melt, the heterogeneous precipitation on TiO{sub x}·FeO surfaces is the main reaction process. Ti-Al oxides have lower agglomeration ability than that of Al{sub 2}O{sub 3}, which in turn, contribute to a low agglomeration frequency as well.

36 MATERIALS SCIENCE↗

Modeling the Effects of Tidal Energy Extraction on Estuarine Hydrodynamics in a Stratified Estuary

A three-dimensional coastal ocean model with a tidal turbine module was used in this paper to study the effects of tidal energy extraction on temperature and salinity stratification and density driven two-layer estuarine circulation. Numerical experiments with various turbine array configurations were carried out to investigate the changes in tidally mean temperature, salinity and velocity profiles in an idealized stratified estuary that connects to coastal water through a narrow tidal channel. The model was driven by tides, river inflow and sea surface heat flux. To represent the realistic size of commercial tidal farms, model simulations were conducted based on a small percentage of the total number of turbines that would generate the maximum extractable energy in the system. Model results indicated that extraction of tidal energy will increase the vertical mixing and decrease the stratification in the estuary. Extraction of tidal energy has stronger impact on the tidally-averaged salinity, temperature and velocity in the surface layer than the bottom. Energy extraction also weakens the two-layer estuarine circulation, especially during neap tides when tidal mixing the weakest and energy extraction is the smallest. Model results also show that energy generation can be much more efficient with higher hub height with relatively small changes in stratification and two-layer estuarine circulation.

Yang, Zhaoqing↗

On the Nature of Mass Spectrometer Analyzer Contamination

Sample throughput in electrospray ionization mass spectrometry (ESI-MS) is limited by the need for frequent ion path cleaning to remove accumulated debris that can lead to charging and general performance degradation. Contamination of ion optics within the vacuum system is particularly problematic as routine cleaning requires additional time for cycling the vacuum pumps. Differential mobility spectrometry (DMS) can select targeted ion species for transmission, thereby reducing the total number of charged particles entering the vacuum system. In this work, we characterize the nature of instrument contamination, describe efforts to improve mass spectrometer robustness by applying DMS prefiltering to reduce contamination of the vacuum ion optics, and demonstrate the capability of DMS to extend the interval between mass spectrometer cleaning. In addition, we introduce a new approach to effectively detect large charged particles formed during the electrospray ionization (ESI) process. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix Assisted and/or Laser Desorption Ionization Quadrupole Ion Trap Time-of-Flight Mass Spectrometry of WO{sub 3} Clusters Formation in Gas Phase. Nanodiamonds, Fullerene, and Graphene Oxide Matrices

The formation of W{sub x}O{sub y}{sup +●/-●} clusters in the gas phase was studied by laser desorption ionization (LDI) and matrix assisted laser desorption ionization (MALDI) of solid WO{sub 3}. LDI produced (WO{sub 3}){sub n}{sup +●/-●} (n = 1-7) clusters. In MALDI, when using nano-diamonds (NDs), graphene oxide (GO), or fullerene (C{sub 60}) matrices, higher mass clusters were generated. In addition to (WO{sub 3}){sub n}{sup -●} clusters, oxygen-rich or -deficient species were found in both LDI and MALDI (with the total number of clusters exceeding one hundred ≈ 137). This is the first time that such matrices have been used for the generation of(WO{sub 3}){sub n}{sup +●/-●} clusters in the gas phase, while new high mass clusters (WO{sub 3}){sub n}{sup -●} (n = 12-19) were also detected. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantified uncertainty in thermodynamic modeling for materials design

Phase fractions, compositions and energies of the stable phases as a function of macroscopic composition, temperature, and pressure (X-T-P) are the principle correlations needed for the design of new materials and improvement of existing materials. They are the outcomes of thermodynamic modeling based on the CALculation of PHAse Diagrams (CALPHAD) approach. Here, the accuracy of CALPHAD predictions vary widely in X-T-P space due to experimental error, model inadequacy and unequal data coverage. In response, researchers have developed frameworks to quantify the uncertainty of thermodynamic property model parameters and propagate it to phase diagram predictions. In most previous studies, uncertainty was represented as intervals on phase boundaries (with respect to composition or temperature) and was unable to represent the uncertainty in invariant reactions or in the stability of phase regions. In this work, we propose a suite of tools that leverages samples from the multivariate model parameter distribution to represent uncertainty in forms that surpass previous limitations and are well suited to materials design. These representations include the distribution of phase diagrams and their features, as well as the dependence of phase stability and the distributions of phase fraction, composition, activity and Gibbs energy on X-T-P location - irrespective of the total number of components. Most critically, the new methodology allows the material designer to interrogate a certain composition and temperature domain and get in return the probability of different phases to be stable, which can positively impact materials design.

36 MATERIALS SCIENCE↗