Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

Insights into the Interconnection of the Electrodes and Electrolyte Species in Lithium–Sulfur Batteries Using Spatially Resolved Operando X-ray Absorption Spectroscopy and X-ray Fluorescence Mapping

The lithium–sulfur (Li–S) battery chemistry has attracted great interest in the last decade because of its outstanding theoretical gravimetric energy density compared to the state-of-the-art lithium-ion battery technology. However, practically achieved energy density is still far below the theoretical value, even in small laboratory-scale batteries. The problems seen in laboratory-scale batteries will inevitably increase during scale-up to large application-format cells, as the electrolyte to active material (AM) ratio will need to be reduced in these cells to achieve high gravimetric energy density on cell-level basis. Our paper shows the unique possibility of X-ray fluorescence (XRF) mapping to visualize the spatial distribution of the AM inside operating Li–S batteries in all cell components [working electrode (WE), separator, and counter electrode (CE)]. Through a combination of operando XRF mapping and X-ray absorption spectroscopy, we show that unless self-discharge is efficiently prevented, the AM can completely dissolve and distribute throughout the cell stack within a time frame of 2 h, causing poor capacity retention. Finally, using a polysulfide diffusion barrier between the WE and the CE, we successfully suppress these processes and thereby establish a tool for examining the sealed cathode electrode compartment, enabling sophisticated studies for future optimization of the WE processes.

25 ENERGY STORAGE↗

External Carotid-Internal Jugular Fistula as a Late Complication After Carotid Endarterectomy: A Rare Case

A 66-year-old man presented with mild amnesia, progressive fatigue, ataxia, visual hallucinations, and debility. His past medical history included right-sided carotid endarterectomy performed elsewhere 6 years previously. Cranial magnetic resonance imaging showed left parieto-occipital arteriovenous malformation-like tortous vessels, venous congestion, and ischemic areas. Cerebral angiography showed right-sided compound external carotid artery-internal jugular vein (IJV) fistula, and distal occlusion of the right IJV. Transvenous embolization via contralateral IJV was performed, and the fistula, together with fistulous portion of the distal IJV, was sealed using coils. Two years later, patient is well with normal neurologic examination findings. The presence of an arteriovenous communication after vascular surgery is a serious complication with potential long-term effects and therefore should be diagnosed and treated as promptly as possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Radiation Transport Due to Activated Coolant in the ITER Neutral Beam Injection Cell

Detailed spatial distributions of the biological dose rate due to a variety of sources are required for the design of the ITER tokamak facility to ensure that all radiological zoning limits are met. During operation, water in the Integrated loop of Blanket, Edge-localized mode and vertical stabilization coils, and Divertor (IBED) cooling system will be activated by plasma neutrons and will flow out of the bioshield through a complex system of pipes and heat exchangers. This paper discusses the methods used to characterize the biological dose rate outside the tokamak complex due to 16 N gamma radiation emitted by the activated coolant in the Neutral Beam Injection (NBI) cell of the tokamak building. Activated coolant will enter the NBI cell through the IBED Primary Heat Transfer System (PHTS), and the NBI PHTS will also become activated due to radiation streaming through the NBI system. To properly characterize these gamma sources, the production of 16 N, the decay of 16 N, and the flow of activated water through the coolant loops were modeled. The impact of conservative approximations on the solution was also examined. Once the source due to activated coolant was calculated, the resulting biological dose rate outside the north wall of the NBI cell was determined through the use of sophisticated variance reduction techniques. The AutomateD VAriaNce reducTion Generator (ADVANTG) software implements methods developed specifically to provide highly effective variance reduction for complex radiation transport simulations such as those encountered with ITER. Using ADVANTG with the Monte Carlo N-particle (MCNP) radiation transport code, radiation responses were calculated on a fine spatial mesh with a high degree of statistical accuracy. In conclusion, advanced visualization tools were also developed and used to determine pipe cell connectivity, to facilitate model checking, and to post-process the transport simulation results.

59 BASIC BIOLOGICAL SCIENCES↗

ON THE SIX-YEAR PERIOD IN THE RADIAL VELOCITY OF ANTARES A

We examine the century-long historical data and compare it with our new radial-velocity measurements to determine an improved period. We find a period of 2167 {+-} 5 days (5.93 {+-} 0.01 years). Both orbital motion and pulsation are considered as possible causes of the velocity variation. Temperature variations we deduce from line-depth ratios support the pulsation hypothesis. A temperature minimum occurs in 2009, 70 days after the radial-velocity minimum. We deduce a radius change of 19% {+-} 4% from an integration of the radial-velocity curve and predict a visual magnitude variation {approx}0.2 from the radius and temperature variation.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-9A-07: Fabrication and Calibration of a Novel High-Sensitivity Collimator for Brain SPECT Imaging

Purpose: We have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. The collimator was manufactured and initial evaluation has been completed. Methods: The collimator was time-consuming and challenging to build. Because our desired hole pattern required substantial variations in hole angle, we designed two supporting plates to securely position about 34,000 hexagonal, slightly tapered, 75-mm long steel pins. The holes in the plates were modeled to yield the desired focal length, hole length and septal thickness. Molten lead was poured in between the plates, and all pins were removed after cooling. The sensitivity gain compared to a fan-beam collimator was measured using a point source placed along the central ray at several distances from the collimator face. Visual inspection of the holes was not possible as the collimator was sealed so it could be safely mounted on a SPECT system. Therefore, we prepared a 2D array of 768, ∼48μCi Tc-99m point sources, separated by 1.6 cm. The array was imaged for 10 minutes at 4 shifted locations to reduce sampling distance to 8 mm. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 3 to 176. Examination of the projections of the 4×768 point sources revealed that fewer than 2% of the holes were fully or partially blocked, which indicates that the intensive manual fabrication process was very successful. Conclusion: We have designed and manufactured a novel collimator for brain SPECT imaging. As expected, the sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data will require a measured system function.

60 APPLIED LIFE SCIENCES↗

Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

Background: Colorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). Methods: Patients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed. Results: Between May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p = 0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p = 0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred. Conclusion: NBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Compatible Surgical Instruments Final Report CRADA No. TSB-0847-94

ITI is a California-based company formed in February 1994 to design, manufacture and market premium quality magnetic resonance imaging (MRI) medical devices and instruments. These products are for use in existing MR irnagers, as well as for emerging applications in reaI-tirne MRI-guided surgery and interventional radiology. Such application require products that are MR biocompatible and in many cases MR visible. In an era of managed health care, purchasing decisions by hospitals, medical centers and insurers emphasize cost-effectiveness. Since minimally invasive therapy reduces surgical costs, shortens hospital stay and post-operative rehabilitation, this segment of the health care industry is expected to grow rapidly. Many experts believe that high-speed MRI-guided therapy offers the best opportunity to maximize the benefits of minimally invasive procedures because MIH enables the clearest differentiation of normal from abnormal tissues. Manufacturers of conventional imagers, including General Electric, Siemens, and Philips, have aleady made substantial investments aid produced prototype high-speed MRI.imagers to permit continuous real-time visualization of tissues during surgical and endovascular procedures. According to forecasts published by the National Electrical Manufacturers Association (1993) and the Medical and Healthcare Marketplace Guide (1992), the average world~wide growth rate of MN installations is expected to be about 7% annually for the next three years, increasing 12-15% annually thereafter as developing countries buy increasing numbers of MM units. The same forecasters project 17,000- 20,000 MRI irnagers world-wide by the year 2000, with a throughput of 2,300-6,000 patients per machine per year, at an.average examination cost.of $560-780-per-patient.

60 APPLIED LIFE SCIENCES↗

WINS. Market Simulation Tool for Facilitating Wind Energy Integration

Integrating 20% or more wind energy into the system and transmitting large sums of wind energy over long distances will require a decision making capability that can handle very large scale power systems with tens of thousands of buses and lines. There is a need to explore innovative analytical and implementation solutions for continuing reliable operations with the most economical integration of additional wind energy in power systems. A number of wind integration solution paths involve the adoption of new operating policies, dynamic scheduling of wind power across interties, pooling integration services, and adopting new transmission scheduling practices. Such practices can be examined by the decision tool developed by this project. This project developed a very efficient decision tool called Wind INtegration Simulator (WINS) and applied WINS to facilitate wind energy integration studies. WINS focused on augmenting the existing power utility capabilities to support collaborative planning, analysis, and wind integration project implementations. WINS also had the capability of simulating energy storage facilities so that feasibility studies of integrated wind energy system applications can be performed for systems with high wind energy penetrations. The development of WINS represents a major expansion of a very efficient decision tool called POwer Market Simulator (POMS), which was developed by IIT and has been used extensively for power system studies for decades. Specifically, WINS provides the following superiorities; (1) An integrated framework is included in WINS for the comprehensive modeling of DC transmission configurations, including mono-pole, bi-pole, tri-pole, back-to-back, and multi-terminal connection, as well as AC/DC converter models including current source converters (CSC) and voltage source converters (VSC); (2) An existing shortcoming of traditional decision tools for wind integration is the limited availability of user interface, i.e., decision results are often text-based demonstrations. WINS includes a powerful visualization tool and user interface capability for transmission analyses, planning, and assessment, which will be of great interest to power market participants, power system planners and operators, and state and federal regulatory entities; and (3) WINS can handle extended transmission models for wind integration studies. WINS models include limitations on transmission flow as well as bus voltage for analyzing power system states. The existing decision tools often consider transmission flow constraints (dc power flow) alone which could result in the over-utilization of existing resources when analyzing wind integration. WINS can be used to assist power market participants including transmission companies, independent system operators, power system operators in vertically integrated utilities, wind energy developers, and regulatory agencies to analyze economics, security, and reliability of various options for wind integration including transmission upgrades and the planning of new transmission facilities. WINS can also be used by industry for the offline training of reliability and operation personnel when analyzing wind integration uncertainties, identifying critical spots in power system operation, analyzing power system vulnerabilities, and providing credible decisions for examining operation and planning options for wind integration. Researches in this project on wind integration included (1) Development of WINS; (2) Transmission Congestion Analysis in the Eastern Interconnection; (3) Analysis of 2030 Large-Scale Wind Energy Integration in the Eastern Interconnection; (4) Large-scale Analysis of 2018 Wind Energy Integration in the Eastern U.S. Interconnection. The research resulted in 33 papers, 9 presentations, 9 PhD degrees, 4 MS degrees, and 7 awards. The education activities in this project on wind energy included (1) Wind Energy Training Facility Development; (2) Wind Energy Course Development.

17 WIND ENERGY↗

Ultraintense, ultrashort pulse X-ray scattering in small molecules

In this work, we examine X-ray scattering from an isolated organic molecule from the linear to nonlinear absorptive regime. In the nonlinear regime, we explore the importance of both the coherent and incoherent channels and observe the onset of nonlinear behavior as a function of pulse duration and energy. In the linear regime, we test the sensitivity of the scattering signal to molecular bonding and electronic correlation via calculations using the independent atom model (IAM), Hartree–Fock (HF) and density functional theory (DFT). Finally, we describe how coherent X-ray scattering can be used to directly visualize femtosecond charge transfer and dissociation within a single molecule undergoing X-ray multiphoton absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthetic Scientific Image Generation with VAE, GAN, and Diffusion Model Architectures

Generative AI (genAI) has emerged as a powerful tool for synthesizing diverse and complex image data, offering new possibilities for scientific imaging applications. This review presents a comprehensive comparative analysis of leading generative architectures, ranging from Variational Autoencoders (VAEs) to Generative Adversarial Networks (GANs) on through to Diffusion Models, in the context of scientific image synthesis. We examine each model's foundational principles, recent architectural advancements, and practical trade-offs. Our evaluation, conducted on domain-specific datasets including microCT scans of rocks and composite fibers, as well as high-resolution images of plant roots, integrates both quantitative metrics (SSIM, LPIPS, FID, CLIPScore) and expert-driven qualitative assessments. Results show that GANs, particularly StyleGAN, produce images with high perceptual quality and structural coherence. Diffusion-based models for inpainting and image variation, such as DALL-E 2, delivered high realism and semantic alignment but generally struggled in balancing visual fidelity with scientific accuracy. Importantly, our findings reveal limitations of standard quantitative metrics in capturing scientific relevance, underscoring the need for domain-expert validation. We conclude by discussing key challenges such as model interpretability, computational cost, and verification protocols, and discuss future directions where generative AI can drive innovation in data augmentation, simulation, and hypothesis generation in scientific research.

Generative Adversarial Networks↗

Quantifying and connecting atomic and crystallographic grain boundary structure using local environment representation and dimensionality reduction techniques

In this paper, the relationship between grain boundary crystallography and grain boundary atomic structure is examined, using [100] - symmetric tilt grain boundaries in nickel. The structural unit model is used as a benchmark to evaluate the atomic structure description capacities of an emerging structural descriptor, the local environment representation, which itself is a refinement of the Smooth Overlap of Atomic Positions (SOAP) descriptor. We show that the local environment representation encodes both the information of the structural unit model and additional information, such as distortion in the structural units and the arrangement of the structural units at the interface. The use of the local environment representation permits the use of a visualization tool known as SPRING to represent structural similarities between grain boundaries. With the SPRING representation, we produce objective evidence of a relationship between crystallography and atomic structure, at least for [100] - symmetric tilt grain boundaries.

36 MATERIALS SCIENCE↗

Microstructural characterization of SiO2/Ni nanocomposites electrodeposited from a sulphate bath modified by PEI

Highlights: • SiO{sub 2}/Ni + PEI nanocomposites are deposited from the sulphate bath containing PEI. • PEI allows incorporation of higher SiO{sub 2} vol% in SiO{sub 2}/Ni + PEI nanocomposites. • PEI in the form of a thin layer surrounds spherical Ni nanograins and SiO{sub 2} clusters. • PEI action ensures high hardness, tribological properties and corrosion resistance. - Abstract: SiO{sub 2}/Ni nanocomposite coatings containing well-dispersed SiO{sub 2} nanoparticles were electrodeposited from a sulphate bath with and without the addition of polyethylenimine (PEI) as a cationic surfactant. The surface morphology and microstructure in the cross-sections of the deposited nanocomposites were examined by scanning electron microscopy. More detailed microstructure characterization was performed using transmission, scanning-transmission and high resolution transmission electron microscopy. It was determined that the addition of 0.05 g/L and 0.1 g/L of PEI allows the incorporation of SiO{sub 2} nanoparticles in the nickel matrix to be increased in comparison with the nanocomposite deposited without a surfactant. Based on high spatial resolution microanalysis, performed using high count rate energy dispersive spectroscopy of characteristic X-rays in the scanning-transmission mode, the distribution of SiO{sub 2} nanoparticles in the nanocomposite was visualized on elemental maps. Image analysis of the electron microscopy images enabled the mean equivalent circle diameters of grains in the nickel matrix to be determined, together with the volume fraction of SiO{sub 2} nanoparticles in the nanocomposites. The volume fraction of SiO{sub 2} clusters in the SiO{sub 2}/Ni + PEI nanocomposites with the addition of 0.05 g/L and 0.1 g/L of PEI is equal to 18.4% and 13.3%, respectively. Furthermore, the PEI addition allows the nickel grain size in the matrix to be reduced. The combination of different imaging techniques confirmed that PEI is not only present as a surfactant in the electrolytic bath, but also incorporates into the microstructure of the nanocomposite. Nanocomposites electrodeposited in the presence of 0.05 g/L of PEI exhibit higher hardness, good tribological properties and improved corrosion resistance. Although increasing the PEI concentration in the bath up to 0.1 g/L strongly promotes grain size reduction and increase of the SiO{sub 2} volume fraction, it also causes an increase in the PEI fraction embedded in the microstructure, which results in deterioration of the properties of the SiO{sub 2}/Ni + PEI nanocomposites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Live-Cell Quantum Dot-Based Tracking of Plant & Microbial Extracellular Vesicles

All cellular organisms examined to date release various types of small vesicles called extracellular vesicles (EVs). They were originally thought to be unimportant, but research into EVs as carriers of key messages for communication within large, multicellular organisms or between interacting organisms has gained interest in many different scientific areas of study. Recently, it was discovered that both plants and their pathogenic fungi generate EVs and they are important vehicles for sending plant signals to thwart invasion by fungal pathogens, and in response, fungi use EVs to help evade plant defenses. This project aimed to develop new ways to visualize EVs and their potential nucleic acid cargo isolated from the crop plant, sorghum. We adapted a click chemistry-based method for making quantum dot-based RNA sensors, which will be a useful tool for others studying small RNAs. These sensors were not used detect RNA in sorghum EVs because unlike EVs from Arabidopsis, sorghum EVs were not enriched for specific small RNAs. This interesting difference shifted the project in an exciting direction, which focused on comparing EV proteomes. Our study discovered that greater than 60% of Arabidopsis EV proteins were also found in the sorghum EV proteome, revealing a partial conservation between a eudicot and monocot plant. These studies have raised new, fundamental questions on the conserved function of EVs in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Nuclear Analysis of ITER - Paper 129

The world record fusion power production is 16.1 MW (5.7x10{sup 18} n/s). This was achieved at JET in 1995. The neutron budget during that experimental campaign was 2.5x10{sup 20} neutrons. In the first few seconds of an ITER full power pulse, the neutron production will exceed that the total from the entire history of previous controlled fusion experiments. It is envisaged that ITER should produce as much as 700 MW of fusion power. (This is the maximum envisaged power production from the plasma and does not include power multiplication in the blankets or shielding). This equates to the production of 2.48x10{sup 20} 14-MeV neutrons/s which will give an uncollided flux at the first wall of approximately 4x10{sup 13} n/cm{sup 2}/s and a total with the addition of the collided flux of some 10{sup 14} n/cm{sup 2}/s. For safety and licensing purposes it is the responsibility of ITER to satisfy the host state regulations and must limit doses to the public and staff. Furthermore, sufficient shielding must be provided to ensure that all components function adequately; and for decommissioning, ITER has a responsibility to reduce the volume and radio-toxicity of waste. The construction, operational and decommissioning phases of ITER are expected to last in excess of 30 years and the nuclear issues will be of critical importance throughout this time. The huge leap in neutron production in fusion experiments means that extensive nuclear analysis is required for ITER and it is the thesis of this paper that it is required at an unprecedented level. This is because of the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry and the complexity of the sources and level of detail required. As a result of this unprecedented challenge the latest techniques for analysis, variance reduction and data display are being employed and in some cases being specifically developed. In this paper a few of the many representative examples of nuclear analysis will illustrate the thesis. The paper includes an examination of areas where further development could be made in the areas of radiation shield and nuclear analysis. Extensive nuclear analysis is required at ITER and the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry, and the complexity of the sources mean that analysis is required at an unprecedented level of detail and quality. The latest techniques for analysis, variation reduction and data display are being employed and in some cases being specifically developed. Developments are required in areas of analysis, data visualization and experimental verification. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Grid Operator Analytics and Assessment Tools for Inverter- Based Resources Dominated Grid (GOAAT-IBR) Project Update

This presentation provides an update on the OPTIMA GOAAT project, with emphasis on the cloud-native data platform developed in-house to ingest, manage, and operationalize high-resolution power system data. Since our last NASPI presentation, accessible via OSTI ID #2671437, the project team advanced the design and deployment of a scalable architecture capable of handling both synchronized and non-synchronized streams, including PMU, point-on-wave (POW), COMTRADE, and SCADA data. These materials review the project status, recent progress, and key lessons learned. The core of the presentation examines the architecture and engineering of our cloud-native ingestion and data management platform. We then explain how pipelines were designed to collect, normalize, time-align, store, and serve heterogeneous data at scale. We will discuss design choices such as data models, streaming versus batch ingestion, storage tiers, and interoperability with analytics applications. Practical experiences with cloud-native technologies were shared during the event, including benefits, limitations, and integration challenges in a utility environment, along with methods used to improve performance, reduce latency, and optimize resource usage. The presentation also showcases user interface designs and visualization tools that convert raw measurements and analytics results into intuitive, actionable insights for operators and engineers. During the presentation examples were provided demonstrating how visualization, event views, and summarized analytics enhance situational awareness and support operational decision-making. These use cases illustrate how a well-designed data infrastructure can bridge the gap between high-volume measurements and practical grid operations.

Aminifar, Farrokh↗

Experimental study of three-dimensional CO 2 -water drainage and fracture-matrix interactions in fractured porous media

Estimation of CO 2 storage capacity in fractured porous reservoirs requires a better understanding of the CO 2 -water flow fundamentals in fracture-matrix systems. There are few core-flood experiments on three-dimensional CO 2 -water drainage in a fracture-matrix system, yet none have examined the impacts of the capillary continuity of fractures and fracture-matrix interactions. In this study, twelve drainage experiments were conducted in four fracture-matrix columns, each comprising a vertical stack of a cylindrical rock core, a filter paper serving as an analogue to a horizontal fracture, and a ceramic plate. Here, the core sample was surrounded by open space at the top and circumferential sides to model fractures, allowing for 3-D CO 2 -water drainage in the rock core and displaced water draining across the horizontal fracture. X-ray computed tomography was conducted to visualize the dynamic invasion/drainage processes in four rock core samples showing contrasts in anisotropy, permeability, and heterogeneity. Experimental results show (1) the equilibrium CO 2 saturations in the rock matrix vary from 0.10 to 0.60 at controlled capillary pressures up to 200 kPa, (2) the CO 2 saturations in the matrix increase with water saturation in the horizontal fracture resulting in better capillary continuity for water to drain across the fracture, and (3) the fracture water saturation can be enhanced by the non-uniform fracture capillary pressure and countercurrent flow of CO 2 and water across the fracture-matrix interface. In the case of high fracture water saturation, matrix CO 2 saturation largely depends on matrix anisotropy and heterogeneity. The core-scale experimental results contribute to understand the fracture-matrix interactions and CO 2 storage efficiency in fractured porous media.

54 ENVIRONMENTAL SCIENCES↗