Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Degenerate dwarf X-ray sources

X-ray emission by accreting degenerate dwarfs is examined qualitatively, considering bremsstrahlung and cyclotron fluxes and cooling. Also discussed are strongly magnetic degenerate dwarfs, which are characterized by a blackbody-limited UV cyclotron component and a hard X-ray bremsstrahlung component, both produced by the hot emission region, and a hard UV or soft X-ray blackbody component produced by cyclotron and bremsstrahlung photons. With regard to nonmagnetic and weakly magnetic degenerate dwarfs, it is concluded that degenerate dwarfs can produce larger luminosities than earlier estimates indicated, that even high mass stars can produce low temperature (less than 10 keV) X-ray spectra, and, for moderate and high accretion rates and high (greater than 1.2 solar masses) stellar masses, the spectra exhibit a high energy tail. Individual sources of each type of dwarf are considered, such as the AM Her, DQ Her and SS Cyg classes as well as Cyg X-2 and the Sco X-1 class, and the number of such sources in the Galaxy is estimated.

Lamb, D. Q.↗

5.8 X-ray Calorimeters

X-ray calorimeter instruments for astrophysics have seen rapid development since they were invented in 1984. The prime instrument on all currently planned X-ray spectroscopic observatories is based on calorimeter technology. This relatively simple detection concept that senses the energy of an incident photon by measuring the temperature rise of an absorber material at very low temperatures, can form the basis of a very high performance, non-dispersive spectrometer. State-of-the-art calorimeter instruments have resolving powers of over 3000, large simultaneous band-passes, and near unit efficiency. This coupled with the intrinsic imaging capability of a pixilated x-ray calorimeter array, allows true spectral-spatial instruments to be constructed. In this chapter I briefly review the detection scheme, the state-of-the-art in X-ray calorimeter instruments and the future outlook for this technology.

Porter, F. Scott↗

Examination of the cerium α-ε phase transition under dynamic loading with x-ray diffraction

Recent examination of the cerium Hugoniot with pyrometry and x-ray diffraction (XRD) has revealed a narrow solid-liquid two-phase region. It has been suggested that nonequilibrium melting may be occurring along the Ce Hugoniot, with either melt kinetics or a sluggish α-ε transition impeding the transition. In particular, the kinetics of the α-ε is unknown and the location of the phase boundary is in dispute. Static measurements suggest a nearly vertical phase boundary that intersects the Hugoniot at 6–7 GPa. This lies in direct conflict with dynamic measurements along the Hugoniot observing α-Ce through incipient melt. This work presents dynamic experiments using XRD to examine the behavior of the α-ε phase transition. The results show that the α-ε phase transition occurs through a tetragonal distortion, with the transition beginning at temperatures below the solid Hugoniot. Following the initial deviation from an ideal fcc structure, the c/a ratio is found to gradually increase with no steady value observed in the ε phase within the range of these experiments (below 17 GPa). Multiple diffraction patterns captured during the peak stress state show no significant change in c/a ratio prior to uniaxial release, upon which Ce reverts to an fcc structure. Furthermore, the results indicate that the α-ε transition occurs rapidly, both on loading and release. An examination of the c/a ratio with increasing temperatures suggests 11.5 GPa as a lower bound for the location of the α-ε-liquid triple point.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectra of cosmic X-ray sources

X-ray measurements provide the most direct probes of astrophysical environments with temperatures exceeding one million K. Progress in experimental research utilizing dispersive techniques (e.g., Bragg and grating spectroscopy) is considerably slower than that in areas utilizing photometric techniques, because of the relative inefficiency of the former for the weak X-ray signals from celestial sources. As a result, the term "spectroscopy" as applied to X-ray astronomy has traditionally satisfied a much less restrictive definition (in terms of resolving power) than it has in other wavebands. Until quite recently, resolving powers of order unity were perfectly respectable, and still provide (in most cases) the most useful spectroscopic data. In the broadest sense, X-ray photometric measurements are spectroscopic, insofar as they represent samples of the overall electromagnetic continua of celestial objects.

Holt, S. S.↗

Kinetics and Mechanisms of ZnO to ZIF-8 Transformations in Supercritical CO2 Revealed by in situ X-ray Diffraction

ZIF-8 was synthesized in supercritical carbon dioxide (scCO2). In situ powder X-ray diffraction, ex situ microscopy and simulations, provides a encompassing view of the formation of ZIF-8 and intermediary ZnO@ZIF-8 composites in this nontraditional solvent. Time-resolved imaging exposed divergent physicochemical reaction pathways from previous studies of the growth of anisotropic ZIF-8 core@shell structures in traditional solvents. Synthetically relevant physio-chemical properties of scCO2 were integrated into classical nucleation theory, relating interfacial forces with 3D nu-cleation outcomes. The kinetics of crystallization were examined and displayed a characteristic signature of time- and temperature-dependent mechanisms over the extent of the reaction. Lastly, we show that subtle factors, such as the extent of reaction and the size/shape of sacrificial templates can tailor ZIF-8 composition and size, eliciting control over hierarchical porosity in a nonconventional green solvent.

Sinnwell, Michael A.↗

X-ray Spectra of the Fe-L Complex II: Atomic Data Constraints from the EBIT Experiment and X-Ray Grating Observations of Capella

The Hitomi results for the Perseus cluster have shown that accurate atomic models are essential to the success of X-ray spectroscopic missions and just as important as the store of knowledge on instrumental calibration and astrophysical modeling. Preparing the models requires a multifaceted approach, including theoretical calculations, laboratory measurements, and calibration using real observations. In a previous paper, we presented a calculation of the electron impact cross sections on the transitions forming the Fe-L complex. In the present work, we systematically tested the calculation against cross-sections of ions measured in an electron beam ion trap experiment. A two-dimensional analysis in the electron beam energies and X-ray photon energies was utilized to disentangle radiative channels following dielectronic recombination, direct electron-impact excitation, and resonant excitation processes in the experimental data. The data calibrated through laboratory measurements were further fed into a global modeling of the Chandra grating spectrum of Capella. We investigated and compared the fit quality, as well as the sensitivity of the derived physical parameters to the underlying atomic data and the astrophysical plasma modeling. We further list the potential areas of disagreement between the observations and the present calculations, which, in turn, calls for renewed efforts with regard to theoretical calculations and targeted laboratory measurements.

Liyi Gu↗

The physics of black hole x ray novae

X-ray transients that are established or plausible black hole candidates have been discovered at a rate of about one per year in the galaxy for the last five years. There are now well over a dozen black hole candidates, most being in the category of X-ray novae with low-mass companions. There may be hundreds of such transient systems in the galaxy yet to be discovered. Classic black hole candidates like Cygnus X-1 with massive companions are in the minority, and their census in the galaxy and magellanic clouds is likely to be complete. The black hole X-ray novae (BHXN) do not represent only the most common environment in which to discover black holes. Their time dependence gives a major new probe with which to study the physics of accretion into black holes. The BHXN show both a soft X-ray flux from an optically thick disk and a hard power law tail that is reminiscent of AGN spectra. The result may be new insight into the classical systems like Cyg X-1 and LMC X-1 that show similar power law tails, but also to accretion into supermassive black holes and AGN.

Wheeler, J. C.↗

Contact binary stars. I - An X-ray survey

X-ray emission from a contact binary star was first detected by the HEAO 1 satellite in 1977. Spectroscopic observations of 44i Boo and VW Cep by IUE established the presence of high-temperature chromospheric and transition region emission lines in the spectra of these stars. The HEAO 1 and IUE results implied that the processes causing X-ray emission from VW Cep might be similar to those energizing the solar corona, and that X-ray emission might be a common occurrence among contact binary stars. A series of observations of these stars was, therefore, conducted with the aid of the HEAO 2 (Einstein) Observatory. The present investigation is concerned with the results of these observations, giving attention to their implications with respect to the nature of contact binary stars. The results are compared with similar HEAO 2 studies of coronal X-ray sources in the local region of the Galaxy, in the Hyades, and other rapidly rotating systems.

Cruddace, R. G.↗

Observation of soft X-ray emission from a region near Per X-1

Soft X-ray emission from the X-ray source Per X-1 was observed in the 0.4-2 keV energy interval from a rocket-borne X-ray detector. Spectral analysis of the data indicates that in the 0.4-2 keV band the X-ray emission from Per X-1 can be fitted either with a power law or a steep thermal bremsstrahlung spectrum. This steep spectrum is inconsistent with the spectrum measured above 2 keV. The measured flux in 0.4-2 keV band corresponds to X-ray luminosity of 3 times 10 to the 45th ergs per second for Per X-1.

Agrawal, P. C.↗

Design and Characterization of a Lens-Coupled System for Dynamic X-Ray Diffraction

X-ray diffraction (XRD) is a necessary technique for understanding states of materials under static and dynamic loading conditions. The higher-pressure Equation of State (EOS) of many materials can only be explored via shock or ramp compression at temperatures and pressures of interest. While static XRD work has yielded EOS measurements in the 100 - 200 GPa regime, dynamic X-ray diffraction (DXRD) can explore EOS phases in the TPa regime, which closely resembles inner-core planetary conditions. DXRD hinges on the ability to measure the exact phase or phase change of a material while under dynamic loading conditions. Macroscopic diagnostic systems (e.g. velocimetry and pyrometry) can infer a phase change but not identify the specific phase entered by a material. While microscopic (atomic-level) diagnostic systems (e.g. DXRD) have been designed and implemented in Department of Energy’s (DOE) National Laboratories complex, the unique nature of Sandia National Laboratories’ Pulsed Power Facility (Z Machine) prohibits the use of such devices. The destructive nature of Z experiments presents a challenge to data capture and retrieval. Furthermore there are electromagnetic interference, X-ray background, and mechanical constraints to consider. Thus, a multi-part X-ray diagnostic for use on the Z Machine and Z-Beamlet Laser system has been designed and analyzed. Portions of this new DYnamic SCintillator Optic (DYSCO) have been built, tested and fielded. A data analysis software has been written. Finally, the radiance profile of the DYSCO’s scintillator has been characterized through experiments performed at the University of Arizona.

36 MATERIALS SCIENCE↗

Study of optical properties of X-ray sources

X-ray sources are reported for HZ Herculis, supergiant primary X-ray binary systems, and Cyg X-3. Also reported is an analysis of earlier optical and X-ray observations, along with optical coverage of the 1974 lunar occulation of the Crab Nebula.

Vandenbout, P. A.↗

X-Ray Diffraction and Electron Microscopy Studies of the Size Effects on Pressure-Induced Phase Transitions in CdS Nanocrystals

In recent years, investigations of the phase transition behavior of semiconducting nanoparticles under high pressure has attracted increasing attention due to their potential applications in sensors, electronics, and optics. However, current understanding of how the size of nanoparticles influences this pressure-dependent property is somewhat lacking. In particular, phase behaviors of semiconducting CdS nanoparticles under high pressure have not been extensively reported. Therefore, in this work, CdS nanoparticles of different sizes are used as a model system to investigate particle size effects on high-pressure-induced phase transition behaviors. In particular, 7.5, 10.6, and 39.7 nm spherical CdS nanoparticles are synthesized and subjected to controlled high pressures up to 15 GPa in a diamond anvil cell. Analysis of all three nanoparticles using in-situ synchrotron wide-angle X-ray scattering (WAXS) data shows that phase transitions from wurtzite to rocksalt occur at higher pressures than for bulk material. Bulk modulus calculations not only show that the wurtzite CdS nanomaterial is more compressible than rocksalt, but also that the compressibility of CdS nanoparticles depends on their particle size. Furthermore, sintering of spherical nanoparticles into nanorods was observed for the 7.5 nm CdS nanoparticles. Our results provide new insights into the fundamental properties of nanoparticles under high pressure that will inform designs of new nanomaterial structures for emerging applications.

Meng, Lingyao↗

Deep Search for Gamma-Ray Emission from the Accreting X-Ray Pulsar 1A 0535+262

Binary systems are a well-established subclass of gamma-ray sources. The high mass X-ray binary pulsar 1A 0535+262 has been considered to be a possible gamma-ray emitter for a long time, although former gamma-ray searches using the Fermi Large Area Telescope (LAT) and VERITAS data resulted in upper limits only. We aim at a deep search for gamma-ray emission and pulsations from 1A 0535+262 using more than 13 yr of Fermi-LAT data. The analysis was performed for both the whole Fermi-LAT data set, as well as for the X-ray outbursts that 1A 0535+262 has experienced since the launch of Fermi. Various X-ray observations have been used to generate the ephemeris for the pulsation search. We also investigate the long-term gamma-ray flux variability and perform orbital phase-resolved analysis for the outbursts. We did not detect any steady or pulsed gamma-ray emission from 1A 0535+262 during the whole Fermi-LAT mission span or its X-ray outbursts. We thus derived the deepest gamma-ray luminosity upper limits to date at the 95% confidence level to be around (2.3–4.7) × 10 32 erg s -1 depending on different spectral indices assumed, which results in a ratio of L γ to L X (2–150 keV) being (1.9–3.9) × 10 -6 .

79 ASTRONOMY AND ASTROPHYSICS↗

Investigations of Polymethacrylate Tribochemical Films Using X-Ray Spectroscopy and Optical Profilometry

This study investigates the elemental composition and surface morphology of solid tribochemical films formed on steel surfaces. The reversible addition-fragmentation chain transfer (RAFT) method was used to synthesize nine different metal-free polymers, which were blended into commercial base oils. The polymers were either homopolymers of dodecyl methacrylate and ethylhexyl methacrylate or were co-polymers of these monomers with six polar monomers. After tribological testing at 100 degrees C using the ball-on-flat geometry, the resulting tribochemical films were imaged using scanning electron microscopy (SEM) and optical microscopy. The resulting tribochemical films have thicknesses around 50-100 nm. Two of the films corresponding to small (P1-imidazole-containing copolymer) and large (P3-less polar homopolymer) wear were cross-sectioned using focused ion beam (FIB) and analyzed for elemental composition using energy-dispersive X-Ray (EDX) mapping. Oxygen and nitrogen enrichment was observed, consistent with the relative chemical composition of the precursor polymers. Transmission electron microscopy (TEM) evidence suggests that at the worn surface, some organic elements penetrate or are mixed into the steel substrate giving an interlocking appearance. The two samples examined with TEM showed that P1 tribofilm is diffused or mixed with the steel substrate more so than P3, suggesting a stronger affinity and contact during tribofilm formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗