At least 649 records · Page 36

The Interaction Between an Insoluble Particle and an Advancing Solid/Liquid Interface: Micro-Gravity Experiments and Theoretical Developments

The interaction of an insoluble particle with an advancing solid/liquid interface (SLI) has been a subject of investigation for the past four decades. While the original interest stemmed from geology applications (e.g., frost heaving in soil), researchers soon realized that the complex science associated with such an interaction is relevant to many other scientific fields encompassing metal matrix composites (MMCs), high temperature superconductors, inclusion management in steel, growth of monotectics, and preservation of biological cells. During solidification of a liquid containing an insoluble particle, three distinct interaction phenomena have been experimentally observed: instantaneous engulfment of the particle, continuous pushing, and particle pushing followed by engulfment. It was also observed that for given experimental conditions and particle size there is a critical solidification velocity, V(sub cr), above which a particle is engulfed. During solidification of MMCs pushing leads to particle agglomeration at the grain boundaries and this has detrimental effects on mechanical properties of the casting. Consequently, the process must be designed for instantaneous engulfment to occur. This implies the development of accurate theoretical models to predict V(sub cr), and perform benchmark experiments to test the validity of such models. Although considerable progress has been made in understanding the pushing/engulfment phenomenon (PEP), its quantification in terms of the material and processing parameters remains a focus of research. Since natural convection currents occurring during terrestrial solidification experiments complicate the study of PEP, execution of experiments on the International Space Station (ISS) has been approved and funded by NASA. Extensive terrestrial (1g) experiments and preliminary micro-gravity (mu g) experiments on two space shuttle missions have been conducted in preparation for future experiments on the ISS. The investigated systems included metal-ceramic particles (pure aluminum - zirconia particles) and transparent organic - non-reactive particles (succinonitrile - polystyrene and biphenyl - glass). This paper will discuss the experimental results obtained in both lg and pg conditions and the influence of the natural convection on V(sub cr). A summary of past mathematical models and our recent theoretical developments will also be presented to explain the experimentally observed particle/SLI interaction.

Catalina, Adrian V.↗

Probabilistic Fatigue Damage Prognosis Using a Surrogate Model Trained Via 3D Finite Element Analysis

Utilizing inverse uncertainty quantification techniques, structural health monitoring can be integrated with damage progression models to form probabilistic predictions of a structure's remaining useful life. However, damage evolution in realistic structures is physically complex. Accurately representing this behavior requires high-fidelity models which are typically computationally prohibitive. In the present work, a high-fidelity finite element model is represented by a surrogate model, reducing computation times. The new approach is used with damage diagnosis data to form a probabilistic prediction of remaining useful life for a test specimen under mixed-mode conditions.

Leser, Patrick E.↗

Modeling and Analysis Methods for an On-line Enrichment Monitor

The International Atomic Energy Agency (IAEA) has developed an On-Line Enrichment Monitor (OLEM) as one possible component in a new generation of safeguards measures for uranium enrichment plants. The OLEM measures 235U emissions from the UF6 gas flowing through a unit header pipe using NaI(Tl) spectrometers, and corrects for gas density changes using pressure and temperature sensors in order to determine the enrichment of the gas as a function of time. In parallel with the OLEM instrument development, a Virtual OLEM (VOLEM) software tool has been developed that is capable of producing synthetic gamma-ray, pressure, and temperature data representative of a wide range of enrichment plant operating conditions. VOLEM complements instrument development activities and allows the study of OLEM for scenarios that will be difficult or impossible to evaluate empirically. Uses of VOLEM include: investigation of hardware design options; inter-comparison of candidate gamma-ray spectral analysis and enrichment estimation algorithms; uncertainty budget analysis and performance prediction for typical and atypical operational scenarios; and testing of the OLEM data acquisition, analysis and reporting software. This paper describes the technical foundations of VOLEM and illustrates how it can be used. An overview of the nominal instrument design and deployment scenario for OLEM is provided, with emphasis on the key online-assay measurement challenge: accurately determining the portion of the total 235U signal that comes from a background that includes solid uranium deposits on the piping walls. Monte Carlo modeling tools, data analysis algorithms and uncertainty quantification methods are described. VOLEM is then used to quantitatively explore the uncertainty budgets and predicted instrument performance for a plausible range of typical plant operating parameters, and one set of candidate analysis algorithms. Additionally, a series of VOLEM case studies illustrates how an online enrichment monitor might respond in scenarios expected to be atypical, for example weak pressure transients or significant changes in background levels.

Smith, Leon E.↗

Quantification of SARS-CoV-2 spike protein expression from mRNA vaccines using isotope dilution mass spectrometry

The advent of mRNA vaccine technology has been vital in rapidly creating and manufacturing COVID-19 vaccines at an industrial scale. To continue to accelerate this leading vaccine technology, an accurate method is needed to quantify antigens produced by the transfection of cells with a mRNA vaccine product. This will allow monitoring of protein expression during mRNA vaccine development and provide information on how changes to vaccine components affects the expression of the desired antigen. Developing novel approaches that allow for high-throughput screening of vaccines to detect changes in antigen production in cell culture prior to in vivo studies could aid vaccine development. Here, we have developed and optimized an isotope dilution mass spectrometry method to detect and quantify the spike protein expressed after transfection of baby hamster kidney cells with expired COVID-19 mRNA vaccines. Five peptides of the spike protein are simultaneously quantified and provide assurance that protein digestion in the region of the target peptides is complete since results between the five peptides had a relative standard deviation of less than 15 %. In addition, two housekeeping proteins, actin and GAPDH, are quantified in the same analytical run to account for any variation in cell growth within the experiment. IDMS allows a precise and accurate means to quantify protein expression by mammalian cells transfected with an mRNA vaccine.

60 APPLIED LIFE SCIENCES↗

Revisiting spontaneous Raman scattering for direct oxygen atom quantification

In this paper, the counterintuitive and largely unknown Raman activity of oxygen atoms is evaluated for its capacity to determine absolute densities in gases with significant O-density. The study involves C O 2 microwave plasma to generate a self-calibrating mixture and establish accurate cross sections for the 3 P 2 ↔<!-- ↔ --> 3 P 1 and 3 P 2 ↔<!-- ↔ --> 3 P 0 transitions. The approach requires conservation of stoichiometry, confirmed within experimental uncertainty by a 1D fluid model. The measurements yield σ<!-- σ --> J = 2 →<!-- → --> 1 = 5.27 ±<!-- ± --> s y s : 0.53 r a n d : 0.17 ×<!-- × --> 10 -<!-- - --> 31 c m 2 / s r and σ<!-- σ --> J = 2 →<!-- → --> 0 = 2.11 ±<!-- ± --> s y s : 0.21 r a n d : 0.06 ×<!-- × --> 10 -<!-- - --> 31 c m 2 / s r , and the detection limit is estimated to be 1 ×<!-- × --> 10 15 c m -<!-- - --> 3 for systems without other scattering species.

74 ATOMIC AND MOLECULAR PHYSICS↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Bayesian reduced-order deep learning surrogate model for dynamic systems described by partial differential equations

We propose a reduced-order deep-learning surrogate model for dynamic systems described by time-dependent partial differential equations. This method employs space–time Karhunen–Loève expansions (KLEs) of the state variables and space-dependent KLEs of space-varying parameters to identify the reduced (latent) dimensions. Subsequently, a deep neural network (DNN) is used to map the parameter latent space to the state variable latent space. An approximate Bayesian method is developed for uncertainty quantification (UQ) in the proposed KL-DNN surrogate model. The KL-DNN method is tested for the linear advection–diffusion and nonlinear diffusion equations, and the Bayesian approach for UQ is compared with the deep ensembling (DE) approach, commonly used for quantifying uncertainty in DNN models. It was found that the approximate Bayesian method provides a more informative distribution of the PDE solutions in terms of the coverage of the reference PDE solutions (the percentage of nodes where the reference solution is within the confidence interval predicted by the UQ methods) and log predictive probability. The DE method is found to underestimate uncertainty and introduce bias. For the nonlinear diffusion equation, we compare the KL-DNN method with the Fourier Neural Operator (FNO) method and find that KL-DNN is 10% more accurate and needs less training time than the FNO method.

97 MATHEMATICS AND COMPUTING↗

Correlation between speciated hydrocarbon emissions and flame ionization detector response for gasoline/alcohol blends .

The U.S. renewable fuel standard has made it a requirement to increase the production of ethanol and advanced biofuels to 36 billion by 2022. Ethanol will be capped at 15 billion, which leaves 21 billion to come from other sources such as butanol. Butanol has a higher energy density and lower affinity for water than ethanol. Moreover, alcohol fueled engines in general have been shown to positively affect engine-out emissions of oxides of nitrogen and carbon monoxide compared with their gasoline fueled counterparts. In light of these developments, the variety and blend levels of oxygenated constituents is likely to increase in the foreseeable future. The effect on engine-out emissions for total hydrocarbons is less clear due to the relative insensitivity of the flame ionization detector (FID) toward alcohols and aldehydes. It is well documented that hydrocarbon (HC) measurement using a conventional FID in the presence of oxygenates in the engine exhaust stream can lead to a misinterpretation of HC emissions trends for alcohol fuel blends. Characterization of the exhaust stream for all expected hydrocarbon constituents is required to accurately determine the actual concentration of unburned fuel components in the exhaust. In addition to a conventional exhaust emissions bench, this characterization requires supplementary instrumentation capable of hydrocarbon speciation and response factor independent quantification. Although required for certification testing, this sort of instrumentation is not yet widely available in engine development facilities. Therefore, an attempt is made to empirically determine FID correction factors for oxygenate fuels. Exhaust emissions of an engine fueled with several blends of gasoline and ethanol, n-butanol and iso-Butanol were characterized using both a conventional FID and a Fourier transform infrared. Based on these results, a response factor predicting the actual hydrocarbon emissions based solely on FID results as a function of alcohol type and content is presented. Finally, the correlation derived from data presented in this study is compared with equations and results found in the literature.

02 PETROLEUM↗

Cloud cover sampling capability of various satellite combinations for ISCCP

One of the most important objectives of the International Satellite Cloud Climatology Project (ISCCP) is the quantification of cloud cover and associated radiation parameters for climate research. The time-varying nature of cloud cover requires a measurement system that obtains cloud radiance at sufficient time intervals for determining accurate values of cloudiness for the appropriate averaging period. Current plans for the ISCCP call for such day to be acquired every 3 hours during both data and night to ensure that the diurnal cycle of cloud cover is adequately sampled. The satellite system proposed is an array of geostationary and polar-orbiting satellites. The error in mean cloud cover estimates for observation systems which do not include geostationary satellites are quantified. Candidates for such a system include two NOAA Sun-synchronous satellites with daylight equatorial-crossing times of 0730 and 1430, and a USSR satellite in an 81 deg. inclination, 900-km altitude orbit.

Harrison, E. F.↗

Robust Online Monitoring for Calibration Assessment of Transmitters and Instrumentation

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this article, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation • Virtual sensing • Sensor response-time assessment These algorithms incorporate, at their base, a Gaussian Process-based uncertainty quantification (UQ) method. Various plant models (using kernel regression, GP, or hierarchical models) may be used to predict sensor responses under various plant conditions. These predicted responses can then be applied in fault detection (sensor output and response time) and in computing the correct value (virtual sensing) of a failing physical sensor. The methods being evaluated in this work can compute confidence levels along with the predicted sensor responses, and as a result, may have the potential for compensating for sensor drift in real-time (online recalibration). Evaluation was conducted using data from multiple sources (laboratory flow loops and plant data). Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

fault detection↗

High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs

Effective and efficient health management of sensing channels and instrumentation supports reliable and accurate process monitoring capacities in any industry. Current practice in the nuclear industry relies on periodic calibration assessment and correction activities. This time based maintenance technique consists of three steps: i) removal of sensor to a test environment, ii) testing and recalibration, and iii) reinstallation of sensor into its working environment. This procedure is highly labor intensive, adds to the outage cost and timeline, and contributes to worker radiation exposure and ALARA requirements. Furthermore, the human element contributes to error factors in all stages of the procedure. The effectiveness of this calibration procedure after sensors are returned to working environmental variables also raises concerns, and the practicability of this periodic approach is uncertain for future reactor designs with longer operating cycles between refueling outages. Studies indicate that periodic calibration assessment find only 10% of sensing instrumentations with calibration issues during a single outage (18- 24 months), meaning at least 90% of sensors are undergoing unnecessary maintenance actions. This provides an opportunity to maintain the current levels of safety and functional integrity with fewer, more targeted maintenance actions and lower economic burden. Performance-based maintenance planning shows much promise over current periodic maintenance approaches. Specifically, online monitoring (OLM) utilizes the continually collected process data to non-intrusively monitor the calibration status of process instrumentation and detect the onset of de-calibration, thereby minimizing the number of recalibration procedures required. Ultimately, this can lead to termination of time based recalibration at NPPs. OLM utilizes the process measurements made for process monitoring and control to evaluate the calibration status of the sensors and instrumentation making the measurements. OLM can detect and differentiate sensor faults and process anomalies, thus providing a valuable tool to suit the industry's and regulatory body's requirements. Though supported by more than a decade of research, OLM for sensor calibration assessment is yet to be implemented in the US fleet due to regulatory requirements and constraints. As shown in Figure 1, OLM utilizes process data to train statistical models that predict normal, error-free process behavior. Measured process values are compared with error-corrected predictions to ascertain the presence of faults. The reliability of OLM is dependent on the quality of its predictions, measured in part by the uncertainty in these predictions. This research develops a framework to accurately quantify the prediction uncertainty based on Bayesian inference techniques to provide the required confidence levels for OLM systems. The expected outcomes include signal validation by high-accuracy, high-confidence uncertainty quantification for variable sensor types and operating ranges. Furthermore, the framework will facilitate fault detection capacities and so-called virtual sensors, a capability to replace faulty sensor measurements with error-corrected values when a sensor fault is detected. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty quantification of fireball features extracted from nuclear test films using computer vision

Films from the US’s historic nuclear testing era comprise the only extensive collection of imagery depicting high-yield detonations. These films offer unique insights into the characteristics of flows occurring on scales that are difficult to replicate experimentally, and they are a valuable source of data for the validation of models used to describe nuclear detonations. In recent work, we implemented modern computer vision and machine learning techniques to extract features of the fireball following nuclear detonation. With a training dataset of fireball films, we fine-tuned a You Only Look Once 11 (YOLO11) model to detect and track the fireball. Applied to a video, the outer bounding box produced in each frame by YOLO11 is used as an input prompt to Meta’s Segment Anything Model 2 (SAM2), which is shown to accurately predict the boundary of the fireball over time with high resolution. These state-of-the-art computer vision foundation models exhibit impressive visual accuracy in their results but lack an output of values that robustly quantify uncertainty in scientific applications. In this paper, we develop procedures for uncertainty quantification of extracted fireball features. We outline the application of a parallel attention mechanism to calculate uncertainty ranges that complement and better pose model validation data. This higher quality fireball validation data may serve to improve prognostic models describing nuclear detonations in support of nuclear forensic and emergency response activities.

Khristy, Joel [ORNL] (ORCID:0000000209963060)↗

Large-Scale and Deep Quantitative Proteome Profiling Using Isobaric Labeling Coupled with Two-Dimensional LC-MS/MS

Comprehensive, quantitative information on abundances of proteins and their post-translational modifications (PTMs) can potentially provide novel biological insights into diseases pathogenesis and therapeutic intervention. Herein, we introduce a quantitative strategy utilizing isobaric stable isotope-labelling techniques combined with two-dimensional liquid chromatography-tandem mass spectrometry (2D-LC-MS/MS) for large-scale, deep quantitative proteome profiling of biological samples or clinical specimens such as tumor tissues. The workflow includes isobaric labeling of tryptic peptides for multiplexed and accurate quantitative analysis, basic reversed-phase LC fractionation and concatenation for reduced sample complexity, and nano-LC coupled to high resolution and high mass accuracy MS analysis for high confidence identification and quantification of proteins. This proteomic analysis strategy has been successfully applied for in-depth quantitative proteomic analysis of tumor samples, and can also be used for integrated proteome and PTM characterization, as well as comprehensive quantitative proteomic analysis across samples from large clinical cohorts.

Environmental Molecular Sciences Laboratory↗

Assessing entropy for catalytic processes at complex reactive interfaces

When chemical reactions are accelerated by a catalyst, entropy differences between reactants and their transient intermediates can be the driving force behind the promotion or inhibition of desired and parasitic chemical pathways. Understanding and controlling catalytic processes therefore requires both a fundamental and practicable understanding of entropy in addition to enthalpy. In unstructured media such as the vapor phase equilibrated with sparsely covered surfaces, entropy can be adequately accounted for by well-established approaches based on translational, rotational, and harmonic vibrational partition functions. However, these approximations become inadequate in more complex condensed phase environments, e.g., solid liquid interfaces of confined reaction spaces. In this chapter, we provide an overview of the state-of-art in the computational quantification of entropy and its known ramifications on catalysis. The fundamental roles of thermodynamics and kinetics in catalysis are covered in enough detail to appreciate and contextualize the computational methods employed to compute chemically accurate estimates of entropy. These methods are discussed in appropriate detail and range from the ubiquitous harmonic oscillator approximation where entropy unrelated to high frequency oscillations is typically underestimated, to enhanced free energy sampling with molecular dynamics where the desired accuracy must be weighed against the associated computational cost of obtaining it. The rising importance of machine learning and artificial intelligence in accelerating methodological progress in this field is touched upon, as well. Finally, applications, successes, and pitfalls of using these methods are provided to showcase past and present accomplishments while clarifying where improvements in both understanding and methodology are still needed.

Kollias, Loukas↗

Quantification of flexoelectricity in PbTiO 3 /SrTiO 3 superlattice polar vortices using machine learning and phase-field modeling

Flexoelectricity refers to electric polarization generated by heterogeneous mechanical strains, namely strain gradients, in materials of arbitrary crystal symmetries. Despite more than 50 years of work on this effect, an accurate identification of its coupling strength remains an experimental challenge for most materials, which impedes its wide recognition. Here, we show the presence of flexoelectricity in the recently discovered polar vortices in PbTiO 3 /SrTiO 3 superlattices based on a combination of machine-learning analysis of the atomic-scale electron microscopy imaging data and phenomenological phase-field modeling. By scrutinizing the influence of flexocoupling on the global vortex structure, we match theory and experiment using computer vision methodologies to determine the flexoelectric coefficients for PbTiO 3 and SrTiO 3 . Here, our findings highlight the inherent, nontrivial role of flexoelectricity in the generation of emergent complex polarization morphologies and demonstrate a viable approach to delineating this effect, conducive to the deeper exploration of both topics.

36 MATERIALS SCIENCE↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part II - Autonomous Navigation

Nuclear sites across the Unites States and other nations in the world, are prone to extreme radiation effects. To understand the radiation hazards, plan the cleanup efforts; and to meet the quality standards and guidelines, it is important to accurately characterize any nuclear facility. One of the current methods in characterizing facilities is the use of advanced autonomous systems. These are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. Conventional methods of taking radiation measurements by hand within or around the containment areas, and analyzing the collected data to obtain the result are: Ineffective, Puts scientists at risk of Radiation, Not cost-effective. The platform uses the Robotic Operating Systems (ROS) to integrate multiple sensors seamlessly. It can operate near real time by using a distributed processing system to handle large amounts of data: Surrounding cameras, A multi-channel 3D Lidar, Manipulator arm, High-performance gamma-ray spectrometer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncertainty propagation of p-boxes using sparse polynomial chaos expansions

In modern engineering, physical processes are modelled and analysed using advanced computer simulations, such as finite element models. Furthermore, concepts of reliability analysis and robust design are becoming popular, hence, making efficient quantification and propagation of uncertainties an important aspect. In this context, a typical workflow includes the characterization of the uncertainty in the input variables. In this paper, input variables are modelled by probability-boxes (p-boxes), accounting for both aleatory and epistemic uncertainty. The propagation of p-boxes leads to p-boxes of the output of the computational model. A two-level meta-modelling approach is proposed using non-intrusive sparse polynomial chaos expansions to surrogate the exact computational model and, hence, to facilitate the uncertainty quantification analysis. The capabilities of the proposed approach are illustrated through applications using a benchmark analytical function and two realistic engineering problem settings. They show that the proposed two-level approach allows for an accurate estimation of the statistics of the response quantity of interest using a small number of evaluations of the exact computational model. This is crucial in cases where the computational costs are dominated by the runs of high-fidelity computational models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗