Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Inhibition of plasma vasopressin after drinking in dehydrated humans

The effects of nonosmotic and nonvolumetric factors on vasopressin secretion in dehydrated humans has been investigated experimentally, before and after drinking. The subjects of the experiment were five adult men and three adult women weighing 69-77 kg. In order to determine the influence of nonosmotic and nonvolumetric factors on vasopressin secretion, measurements were obtained of the following blood hematological indices: serum Na(+) content; serum K(+) content; osmolality; and hemoglobin. Measurements of hematocrit, plasma arginine vasopressin (AVP), aldosterone, and renin activity were also obtained. It is found that dehydration increased mean serum Na(+) content, osmolality,and AVP. No significant changes were observed in renin activity, hemoglobin, hematocrit, or plasma volume, while plasma aldosterone increased from 11.1 ng/dl after dehydration to 15.6 ng/dl between 30 and 60 min after drinking. A rapid fall of AVP content following rehydration occurred in the absence of changes in the primary regulators of AVP osmolality and plasma volume, with no change in blood pressure. On the basis of the experimental results, it is suggested that oropharyngeal factors may be the mechanism, for the observed decrease in AVP following rehydration.

Geelen, G.↗

The Corona of the Young Solar Analog EK Draconis

First coronal microwave and new soft X-ray observations of the very active, near-Zero-Age Main-Sequence (ZAMS) dGOe star EK Dra = HD 129333 show that this analog of the young Sun is more luminous in both emissions than most single M-dwarf flare stars. Variations in the 8.4 GHz flux include modulation with the optically determined rotation period of 2.7 days. This result points to a non-uniform filling of the corona with energetic electrons due to an incomplete coverage of the surface with active regions and a source volume that is not concentric with the star. The radio luminosity varying between log L(sub R) = 13.6 and 14.6 (L(sub R) in erg/s/Hz) shows evidence for unpolarized gyrosynchrotron flares, while strongly polarized flares were absent during the observations. This star is the first young, truly solar-like main sequence G star discovered in microwaves. Having just arrived on the main sequence, it conclusively proves that young, solar-like G stars can maintain very high levels of radio emission after their T Tau phase. The X-ray observations were obtained from the ROSAT All-Sky Survey (RASS). The average X-ray luminosity amounts to log L(sub x) = 29.9 (L(sub x) in erg/s). A Raymond-Smith type plasma model fit yields two plasma components at temperatures of 1.9 and 10 MK, with volume emission measures of 1.2 and 2.5 x 10 (exp 52)/cu cm, respectively. The X-ray light curve is significantly variable, with the photon count rate from the cooler plasma being strongly modulated by the rotation period; the emission from the hotter plasma is only weakly variable. Modeling of the source distribution in the stellar corona yields electron densities of the order of 4 x 10(exp 10)/cu cm or higher for the cool plasma component. It indicates that a considerable portion of EK Dra's high X-ray luminosity is due to high-density plasma rather than large emission volume. Parameters for an X-ray flare indicate an electron density of 1.75 x 10(exp 11)/cu cm and a source height of (1-2) x 10(exp 10) cm, compatible with a few times the scale height of the cooler plasma component.

Gudel, M.↗

Ionization-Assisted Getter Pumping for Ultra-Stable Trapped Ion Frequency Standards

A method eliminates (or recovers from) residual methane buildup in getter-pumped atomic frequency standard systems by applying ionizing assistance. Ultra-high stability trapped ion frequency standards for applications requiring very high reliability, and/or low power and mass (both for ground-based and space-based platforms) benefit from using sealed vacuum systems. These systems require careful material selection and system processing (cleaning and high-temperature bake-out). Even under the most careful preparation, residual hydrogen outgassing from vacuum chamber walls typically limits the base pressure. Non-evaporable getter pumps (NEGs) provide a convenient pumping option for sealed systems because of low mass and volume, and no power once activated. An ion gauge in conjunction with a NEG can be used to provide a low mass, low-power method for avoiding the deleterious effects of methane buildup in high-performance frequency standard vacuum systems.

Tjoelker, Robert L.↗

Material Response Analysis of a Titan Entry Heatshield

Accurate calculation of thermal protection material response is critical to the vehicle design for missions to the Saturn moon Titan. In this study, Icarus, a three-dimensional, unstructured, finite-volume material response solver under active development at NASA Ames Research Center, is used to compute the in-depth material response of the Huygens spacecraft along its November 11 entry trajectory. The heatshield analyzed in this study consists of a five-layer stack-up of Phenolic Impregnated Carbon Ablator (PICA), aluminum honeycomb, adhesive, and face sheetmaterials. During planetary entry, the PICA outer layer is expected to undergo pyrolysis. A surface energy balance boundary condition that captures both time- and spatial-variance of surface properties during entry is used in the simulation.

material response↗

Apparatus and method for maintaining an article at a temperature that is less than the temperature of the ambient air

An apparatus for maintaining the temperature of an article at a temperature that is below the ambient air temperature includes an enclosure having an outer wall that defines an interior chamber for holding a volume of sealed air. An insert is disposed inside of the chamber and has a body that is made of a porous graphite foam material. A vacuum pump penetrates the outer wall and fluidly connects the sealed air in the interior chamber with the ambient air outside of the enclosure. The temperatures of the insert and article is maintained at temperatures that are below the ambient air temperature when a volume of a liquid is wicked into the pores of the porous insert and the vacuum pump is activated to reduce the pressure of a volume of sealed air within the interior chamber to a pressure that is below the vapor pressure of the liquid.

42 ENGINEERING↗

Crew State and Risk Model Development to Predict Hydration Status During Extravehicular Activity Training Events

Introduction: Hydration is critical for optimal human health and performance and dehydration can lead to impaired cardiovascular function, thermal dysregulation, decreased blood plasma volume, and cognitive impacts, particularly during physical activity. Prolonged and repeated extravehicular activities (EVA) without sufficiently available drinking water may increase risk for dehydration, which could impair crew health and impact mission success. Understanding hydration needs and potential effects on health and performance are necessary to optimize crew well-being and enable successful EVA objectives. This study aims to develop a model of hydration status during EVA using water balance techniques. Methods: Water balance measures were collected on 15 healthy astronauts who performed ≈6-hour simulated microgravity extravehicular activity (EVA) training in the NASA Neutral Buoyancy Laboratory (NBL). Data collected included pre-and post-EVA nude body weight (BW), maximum absorption garment (MAG) weight, Disposable In-suit Drink Bag (DIDB) weight, urine specific gravity (USG), and extra pre-EVA intake (W). Variables were combined to create the water balance model as pre-EVA (Hn)= BWn+ MAGn+ DIDBn+ Wnand post EVA (Hn+1) = BWn+1+ MAGn+1+ DIDBn+1. Urine specific gravity values were used to refine water balance measures into hydration categories: Hydrated, Marginally Hydrated, and Dehydrated. Results: Pre-EVA modeling indicated53% of crew were hydrated, 20% were marginally hydrated, and 27% were dehydrated. Alternately, Hn+1 showed 13% of crew remained hydrated, 47% were marginally hydrated, and 40% were dehydrated at the end of the EVA. Furthermore, 75% of the crewmembers who started sufficiently hydrated finished the run marginally hydrated or dehydrated. According to USG indices presented by Casa and Lawrence, et al. (2000), only 25% of the crew started and remained hydrated throughout the EVA, and those who were dehydrated at the outset stayed dehydrated. Conclusion: Model outcomes assessing hydration status during 6-hour simulated microgravity EVAs demonstrate the necessity to further address hydration requirements for optimal human performance during spaceflight and EVA. This study enables additional baseline development of the Crew State and Risk Model Hydration, Nutrition, and Waste Management component that aims to provide individualized crew state and risk predictions during EVAs. Reference: Casa, D. J., Armstrong, L. E., et al. (2000). National Athletic Trainers’ Association Position Statement: Fluid Replacement for Athletes. Journal of Athletic Training, 35:212-224.

L Cooper↗

Study of Gamma-ray Production from Neutron-induced Activity on Spacecraft for DIORAMA

The Distributed Infrastructure Offering Real{Time Access to Modeling and Analysis (DIORAMA) software provides performance modeling capabilities of the United States Nuclear Detonation Detection System (USNDS) with a focus on the characterization of Space{Based Nuclear Detonation Detection (SNDD) instrument performance [1]. A study was conducted investigating the neutron activation on spacecraft caused by cosmic{ray and trapped proton{induced spallation, and by direct irradiation from hypothetical nuclear detonations as a background component to be incorporated into DIORAMA. The neutron activation background study amasses a database of pre-calculated Monte Carlo data that reflects the delayed gamma-ray production from activated nuclei as a function of incident cosmic or neutron flux, incident energy, material volume, etc. CINDER2008 coupled with MCNPX and the Activation Analysis Tools in the Activation in Accelerator Radiation Environments (AARE) distribution along with a suite of Python scripts are used to calculate and assemble the Monte Carlo database [2{6]. The neutron activation background study improves the fidelity of DIORAMA by providing the neutron-induced activation component to the background of the instruments on-board the spacecraft, and has implications for future instrument design studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Speed Research: Sonic Boom, volume 1

A High-Speed Sonic Boom Workshop was held at LaRC of Feb. 25-27, 1992. The purpose was to make presentations on current research activities and accomplishments and to assess progress in the area of sonic boom since the program was initiated in FY-90. Twenty-nine papers were presented during the 2-1/2 day workshop. Attendees included representatives from academia, industry, and government who are actively involved in sonic-boom research. Volume 1 contains papers related to atmospheric effects on the sonic-boom signature during propagation and on acceptability studies.

Darden, Christine M.↗

Validation of Spectral Analysis as a Noninvasive Tool to Assess Autonomic Regulation of Cardiovascular Function

A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.

Knapp, Charles F.↗

Dysregulation of Macrophage Activation Profiles by Engineered Nanoparticles

Although the potential human health impacts from exposure to engineered nanoparticles (ENPs) are uncertain, past epidemiological studies have established correlations between exposure to ambient air pollution particulates and the incidence of pneumonia and lung infections. Using amorphous silica and superparamagnetic iron oxide (SPIO) as model high production volume ENPs, we examined how macrophage activation by bacterial lipopolysaccharide (LPS) or the lung pathogen Streptococcus pneumoniae is altered by ENP pretreatment. Neither silica nor SPIO treatment elicited direct cytotoxic or pro-inflammatory effects in bone marrow-derived macrophages. However, pretreatment of macrophages with SPIO caused extensive reprogramming of nearly 500 genes regulated in response to LPS challenge, hallmarked by exaggerated activation of oxidative stress response pathways and suppressed activation of both pro- and anti-inflammatory pathways. Silica pretreatment altered regulation of only 67 genes, but there was strong correlation with gene sets affected by SPIO. Macrophages exposed to SPIO displayed a phenotype suggesting an impaired ability to transition from an M1 to M2-like activation state, characterized by suppressed IL-10 induction, enhanced TNFα production, and diminished phagocytic activity toward S. pneumoniae. Studies in macrophages deficient in scavenger receptor A (SR-A) showed SR-A participates in cell uptake of both the ENPs and S. pneumonia and co-regulates the anti-inflammatory IL-10 pathway. Thus, mechanisms for dysregulation of innate immunity exist by virtue that common receptor recognition pathways are used by some ENPs and pathogenic bacteria, although the extent of transcriptional reprogramming of macrophage function depends on the physicochemical properties of the ENP after internalization. Our results also illustrate that biological effects of ENPs may be indirectly manifested only after challenging normal cell function. Finally, nanotoxicology screening strategies should therefore consider how exposure to these materials alters susceptibility to other environmental exposures.

Kodali, Vamsi↗

Orthostatic fluid-electrolyte and endocrine responses in fainters and nonfainters

The responses to orthostasis of fluid-electrolyte and endocrine indicators in persons subject and not subject to fainting during tilting are investigated, along with the effects of heat acclimatization and physical training on those responses. Plasma volume and electrolytes and plasma vasopressin and renin activity were determined in tilt-table tests conducted before and after an eight-day period of daily heat acclimation during exercise at 50% maximal oxygen uptake at 40 C, or a control period of exercise at 24 C. Half of the 10 subjects in the study, regardless of exercise regime, showed improved orthostatic reactions in the second tilting test, related to increases in post-tilt plasma volume and potassium concentration, particularly in the nonfainters. In the first test, plasma renin activity is observed to increase fivefold and plasma vasopressin 50 times after the transition from the supine to the orthostatic positions; the respective increases were reduced by 50 and 75% in the second test. The fainters also exhibit a greater increase in vasopressin and a lower increase in renin activity upon tilting than the nonfainters. Results indicate the orthostatic-induced vasopressin increase to be related to volume control independent of renin activity.

Shvartz, E.↗

Strength statistics of single crystals and metallic glasses under small stressed volumes

It has been well documented that plastic deformation of crystalline and amorphous metals/alloys shows a general trend of “smaller is stronger”. The majority of the experimental and modeling studies along this line have been focused on finding and reasoning the scaling slope or exponent in the logarithmic plot of strength versus size. In contrast to this view, here we show that the universal picture should be the thermally activated nucleation mechanisms in small stressed volume, the stochastic behavior as to find the weakest links in intermediate sizes of the stressed volume, and the convolution of these two mechanisms with respect to variables such as indenter radius in nanoindentation pop-in, crystallographic orientation, pre-strain level, sample length as in uniaxial tests, and others. Furthermore, experiments that cover the entire spectrum of length scales and a unified model that treats both thermal activation and spatial stochasticity have discovered new perspectives in understanding and correlating the strength statistics in a vast of observations in nanoindentation, micro-pillar compression, and fiber/whisker tension tests of single crystals and metallic glasses.

36 MATERIALS SCIENCE↗

Effects of Simulated Spaceflight on Mitochondrial Oxidative Stress in Bone Remodelling

Microgravity and ionizing radiation may contribute to cellular stress; resulting in increased generation of reactive oxygen species (ROS), DNA damage, cell cycle arrest, and cell death. We hypothesized that suppression of excess ROS in osteoblasts and osteoclasts will improve bone microarchitecture. To test our hypothesis, we used irradiated transgenic mCAT mice overexpressing human anti-oxidant catalase gene targeted to the mitochondria (main site for ROS production). mCAT mice expressed the transgene and displayed elevated catalase activity in bone and ex vivo osteoblast and osteoclast cultures. Treated bone from wildtype mice showed elevated levels of oxidative damage whereas mCAT mice did not. Also, increased catalase activity correlated with decreased MDA levels and that increased oxidative damage correlated with decreased % bone volume. Ex-vivo osteoblast colony growth positively correlated with osteoblast catalase activity. mCAT mice displayed reduced % bone volume. Treatment caused significant bone loss in wildtype mice. Treatment also caused slight deficits in microarchitecture of mCAT mice. In conclusion, ROS signaling in both osteoblast and osteoclast lineage cells contribute to skeletal development and remodeling and quenching oxidative damage could play a role in bone loss prevention.

bone loss↗

Kinetic Measurements in Heterogeneous Catalysis

This contribution is about the experimental determination of the rate of a heterogeneous catalytic reaction and the analysis of kinetic data. In this case, the reaction rate can be defined as the frequency at which the closed sequence of elementary steps transforming reactants into products is occurring. However, the rate of chemical reaction is not directly observed; rather, one records the rate of substance change. The rate of chemical reaction is calculated based on the rate of substance change and assumed stoichiometry of the reaction. In order to make this an intensive quantity (i.e., independent of the volume in which the reaction is performed, this frequency is divided by the latter or by a quantity proportional to the latter). As the focus of what follows is on heterogeneously catalyzed reactions this can be the catalyst mass, the catalyst surface area or the total number of active sites present in the reaction volume confined by the walls of a chemical reactor. For example, the rate may be reported as one of the following: Net rate of consumption/production of component i mol m-3 s-1 Net specific rate of consumption/production of component i mol kg-1 s-1 Rate of substance change (per unit volume of catalyst) mol m-3 s-1 Specific reaction rate (per unit mass of catalyst) mol kg-1 s-1 Net rate of consumption/production of component i mol m-2 s-1 The turnover frequency (TOF) is a characteristic originally introduced by Boudart [1] is expressed as TOF=R/G_tot , where R is the steady-state rate of reactant consumption or product generation and G_totis the total areal density of active sites [mol m-2]. The latter is typically taken from experimental chemisorption data obtained at low temperature. The advancement of a chemical reaction leads to changes in the amounts of reactants and products which, for a stoichiometric single reaction, are connected by the stoichiometric coefficients. In many cases, for the sake of simplicity, we will assume that the investigated reaction proceeds according to a single reaction pathway, so that the net production rate of a reaction component is directly proportional to the reaction rate and that the latter equals the net production rate of any of the involved components when divided by the appropriate stoichiometric coefficient. For complex stoichiometric reactions the net production rates of the involved components are linear combinations of the reaction rates. Different goals for kinetic measurements can be formulated: Catalyst testing, i.e., obtaining the kinetic dependences for the development and discrimination of efficient catalytic materials. Precise kinetic characterization of active materials via high-throughput screening is a part of such activity. Detailed kinetics, i.e., revealing the detailed mechanism of complex catalytic reaction via systematic kinetic studies, both steady-state and non-steady-state Industrial kinetics, i.e., obtaining data and relationships for describing and predicting the behaviour of catalytic reactors and processes at industrial scale Finally, mathematical modeling and analysis where kinetic measurements provide data for understanding complex kinetic phenomena, e.g., oscillations, non-linear self-organization, etc.

36 MATERIALS SCIENCE↗

The metabolic and hemodynamic effects of prolonged bed rest in normal subjects

Investigation in six normal subjects of the effects of chronic bed rest on the interrelationships between cardiovascular hemodynamics, catecholamine metabolism, vascular reactivity, renin and aldosterone activity, and electrolyte and fluid balance. Negative sodium and potassium balances and reductions in plasma volume were observed in all subjects, but plasma renin activity and aldosterone secretory rate showed no significant change. Other findings included the observation that major decreases in sodium balance and plasma volume occurred in the early bed rest period and did not correlate closely with the degree of orthostatic intolerance.

Chobanian, A. V.↗

Coronal Heating and the Increase of Coronal Luminosity with Magnetic Flux

We present the observed scaling of coronal luminosity with magnetic flux in a set of quiet regions. Comparison of this with the observed scaling found for active regions suggests an underlying difference between coronal heating in active regions and quiet regions. From SOHO/EIT coronal images and SOHO/MDI magnetograms of four similar large quiet regions, we measure L(sub corona) and Phi(sub total) in random subregions ranging in area from about four supergranules [(70,000 km)(exp 2)] to about 100 supergranules [(0.5 R(sub sun))(exp 2)], where L(sub corona) is the luminosity of the corona in a subregion and Phi(sub total) is the flux content of the magnetic network in the subregion. This sampling of our quiet regions yields a correlation plot of Log L(sub corona) vs Log Phi(sub total) appropriate for comparison with the corresponding plot for active regions. For our quiet regions, the mean values of L(sub corona) and Phi(sub total) both increase linearly with area (simply because each set of subregions of the same area has very nearly the same mean coronal luminosity per unit area and mean magnetic flux per unit area), and in each constant-area set the values of L(sub corona) and Phi(sub total) 'scatter' about their means for that area. This results in the linear least-squares fit to the Log ((L (sub corona)), vs Log ((Phi (sub total)) plot having a slope somewhat less than one. If active regions mimicked our quiet regions in that all large sets of same-area active regions had the same mean coronal luminosity per unit area and same mean magnetic flux per unit area, then the least-squares fit to their Log((L (sub corona)) vs Log((Phi (sub total)) plot would also have a slope of less than one. Instead, the slope for active regions is 1.2. Given the observed factor of three scatter about the least-squares linear fit, this slope is consistent with Phi(sub total) on average increasing linearly with area (A) as in quiet regions, but L(sub corona) on average increasing as the volume (A(exp 1.5)) of the active region instead of as the area. This possibility is reasonable if the heating in active regions is a burning down of previously-stored coronal magnetic energy rather than a steady dissipation of energy flux from below as expected in quiet regions.

Moore, R. L.↗

Theory of activated penetrant diffusion in viscous fluids and colloidal suspensions

We heuristically formulate a microscopic, force level, self-consistent nonlinear Langevin equation theory for activated barrier hopping and non-hydrodynamic diffusion of a hard sphere penetrant in very dense hard sphere fluid matrices. Penetrant dynamics is controlled by a rich competition between force relaxation due to penetrant self-motion and collective matrix structural (alpha) relaxation. In the absence of penetrant-matrix attraction, three activated dynamical regimes are predicted as a function of penetrant-matrix size ratio which are physically distinguished by penetrant jump distance and the nature of matrix motion required to facilitate its hopping. The penetrant diffusion constant decreases the fastest with size ratio for relatively small penetrants where the matrix effectively acts as a vibrating amorphous solid. Increasing penetrant-matrix attraction strength reduces penetrant diffusivity due to physical bonding. For size ratios approaching unity, a distinct dynamical regime emerges associated with strong slaving of penetrant hopping to matrix structural relaxation. A crossover regime at intermediate penetrant-matrix size ratio connects the two limiting behaviors for hard penetrants, but essentially disappears if there are strong attractions with the matrix. Activated penetrant diffusivity decreases strongly with matrix volume fraction in a manner that intensifies as the size ratio increases. We propose and implement a quasi-universal approach for activated diffusion of a rigid atomic/molecular penetrant in a supercooled liquid based on a mapping between the hard sphere system and thermal liquids. Calculations for specific systems agree reasonably well with experiments over a wide range of temperature, covering more than 10 orders of magnitude of variation of the penetrant diffusion constant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗