Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic scale imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Tapping mode microwave impedance microscopy

We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results.

36 MATERIALS SCIENCE↗

Atomic Force Microscopy of Arrays of Asymmetrical DNA Motifs

DNA can easily be assembled into wide and relatively flat nanostructures that lend themselves to study via Atomic Force Microscopy (AFM). It is often important to know which side of an assembly the AFM is imaging. This is particularly crucial for characterizing nanomachines, where the movement must be measured relative to fiducial features visible to the AFM. We have developed a cheap and simple technique for building DNA arrays with distinguishable sides, a technique requiring 10 or fewer strands - dozens or hundreds of strands fewer than used for these purposes previously. Our approach involves constructing arrays out of DNA tiles that have low apparent symmetry when imaged via AFM. We have surveyed the effects of varying degrees of motif asymmetry in AFM micrographs. Even at resolutions where the individual tiles cannot be resolved (either because of sub-optimal tip quality, or very gentle tapping by the AFM tip) the larger scale features of the arrays have predictable structures that allow the determination of which side of the array is facing up. We have used this information to verify that DNA hairpins attached to either the up- or down-facing side of an array on mica can be detected in AFM height scans. We have also characterized differences in appearance between hairpins attached to different sides of the arrays.

59 BASIC BIOLOGICAL SCIENCES↗

Vacuum ultraviolet excitation spectroscopy of the autoionizing Rydberg states of atomic sulfur in the 73 350-84 950 cm{sup -1} frequency range

The photoionization efficiency (PIE) spectra of metastable sulfur (S) atoms in the {sup 1}D and {sup 1}S states have been recorded in the 73 350-84 950 cm{sup -1} frequency range by using a velocity-mapped ion imaging apparatus that uses a tunable vacuum ultraviolet laser as the ionization source. The S({sup 1}D) and S({sup 1}S) atoms are produced by the 193 nm photodissociation of CS{sub 2}. The observed PIE spectra of S({sup 1}D) and S({sup 1}S) shows 35 autoionizing resonances with little or no contribution from direct photoionization into the S{sup +}({sup 4}S{sub 3/2})+e{sup -} ionization continuum. Velocity-mapped ion images of the S{sup +} at the individual autoionizing Rydberg resonances are used to distinguish whether the lower state of the resonance originates from the {sup 1}D, {sup 1}S, or {sup 3}P states. The analysis and assignment of the Rydberg peaks revealed 22 new Rydberg states that were not previously known. The autoionization lifetimes {tau} of the Rydberg states are derived from the linewidths by fitting the lines with the Fano formula. Deviations from the scaling law of {tau}(n*){proportional_to}n*{sup 3}, where n* is the effective quantum number of the Rydberg state, are observed. This observation is ascribed to perturbations by nearby triplet Rydberg states, which shorten the autoionization lifetimes of the singlet Rydberg levels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transition from nonsequential to sequential double ionization in many-electron systems

Understanding strong-field double ionization of many-electron systems is an important fundamental problem with potential implications for molecular imaging within this regime. Using mid-IR radiation, we unambiguously identify the transition from nonsequential (e, 2e) to sequential double ionization in Xe at an intensity below 10 14 W/cm 2 . Ionization from excited orbitals is found to be decisive at low intensities, but we demonstrate that such mechanisms are unimportant in the sequential regime. We utilize these facts to successfully image a molecular dication using laser-induced electron diffraction. This methodology can be used to study molecular dynamics on unprecedented few-femtosecond time scales.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray diffraction of dynamically compressed matter on Sandia's Z Pulsed Power Facility

Sandia's Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigations of fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice, and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Materials Properties (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect the XRD pattern close to the Z-DMP load and to recover the data. We developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn-He c , x-rays to probe a shock-compressed sample on the Z-DMP load. A spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x-rays into a 1-inch thick tungsten housing, where an image plate is used to record the data. We performed experiments to implement the SCDI diagnostic on Z to measure the XRD pattern of shock compressed beryllium samples at pressures of 1.8-2.2 Mbar.

36 MATERIALS SCIENCE↗

Automated and High-Throughput Phase Separation Control for Supramolecular Polymer Blends Enabled by Machine Learning

Supramolecular polymer blends (SPBs) offer tunable morphologies that dictate their macroscopic properties, yet their rational design is limited by the absence of predictive structure−morphology models. Here, we introduce a data-driven highthroughput workflow that integrates modular polymer synthesis, robotic formulation, automated morphology characterization, and machine learning (ML) for accelerated SPB discovery. Using a plug-and-play synthetic strategy, 33 hydrogen-bonding endfunctional homopolymers were prepared and orthogonally combined to generate 260 SPBs in 1 day. A fully automated atomic force microscopy (AFM) pipeline enabled systematic imaging, producing 2340 morphology data sets with minimal human intervention. Domain spacings were extracted through complementary imageprocessing methods and used to train ML models. A support vector regression (SVR) model accurately predicted target phase-separation sizes (50, 100, and 150 nm), which were experimentally validated. This work demonstrates the power of coupling high-throughput experimentation with ML to accelerate morphology discovery and provides one of the first large-scale experimental data sets for supramolecular polymer systems.

ML-guided polymer design↗

Idaho National Laboratory Experimental Program to Measure the Flow Phenomena in a Scaled Model of a Prismatic Gas-Cooled Reactor Lower Plenum for Validation of CFD Codes

The experimental program that is being conducted at the Matched Index-of-Refraction (MIR) Flow Facility at Idaho National Laboratory (INL) to obtain benchmark data on measurements of flow phenomena in a scaled model of a prismatic gas-cooled reactor lower plenum using 3-D Particle Image Velocimetry (PIV) is presented. A description of the scaling analysis, experimental facility, 3-D PIV system, measurement uncertainties and analysis, experimental procedures and samples of the data sets that have been obtained are included. Samples of the data set that will be presented include mean-velocity-field and turbulence data in an approximately 1:7 scale model of a region of the lower plenum of a typical prismatic gas-cooled reactor (GCR) similar to a General Atomics Gas-Turbine-Modular Helium Reactor (GTMHR) design. This experiment has been selected as the first Standard Problem endorsed by the Generation IV International Forum. The flow in the lower plenum consists of multiple jets injected into a confined cross flow - with obstructions. The model consists of a row of full circular posts along its centerline with half-posts on the two parallel walls to approximate flow scaled to that expected from the staggered parallel rows of posts in the reactor design. The model is fabricated from clear, fused quartz to match the refractive-index of the mineral oil working fluid. The benefit of the MIR technique is that it permits high-quality measurements to be obtained without locating intrusive transducers that disturb the flow field and without distortion of the optical paths. An advantage of the INL MIR system is its large size which allows improved spatial and temporal resolution compared to similar facilities at smaller scales. Results concentrate on the region of the lower plenum near its far reflector wall (away from the outlet duct). Inlet jet Reynolds numbers (based on the jet diameter and the time-mean average flow rate) are approximately 4,300 and 12,400. The measurements reveal developing, non-uniform flow in the inlet jets and complicated flow patterns in the model lower plenum. Data include three-dimensional vector plots, data displays along the coordinate planes (slices) and charts that describe the component flows at specific regions in the model. Information on inlet velocity profiles is also presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Note: Spectrometer with multichannel photon-counting detector for beam emission spectroscopy in magnetic fusion devices

A spectrometer based on a linear array photomultiplier tube (PMT) has been developed and calibrated. A 0.635 m focal length Czerny-Turner monochromator combined with a coupling optics provides an image of a narrow 0.5 nm spectral range with a resolution of 0.015 nm/channel on a 32-anode PMT. The system aims at spectroscopy of D{sub α} or H{sub α} lines emitted by a diagnostic atomic beam in a plasma (primarily a motional Stark effect diagnostics). To record a low photon flux of ∼10{sup 6} s{sup −1} per channel with the time resolution of 100 μs, a pulse counting approach has been used. Wideband amplifiers scale single-electron pulses and transmit them to a digital data processing core hardwired in a programmable logic matrix. Calibrations have shown that the aberration-limited instrument function fits to a single detector channel of 1 mm width. Pilot results of passive measurements of D{sub α} light emission from the plasma confined in a magnetic trap are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge order textures induced by non-linear couplings in a half-doped manganite

Abstract The self-organization of strongly interacting electrons into superlattice structures underlies the properties of many quantum materials. How these electrons arrange within the superlattice dictates what symmetries are broken and what ground states are stabilized. Here we show that cryogenic scanning transmission electron microscopy (cryo-STEM) enables direct mapping of local symmetries and order at the intra-unit-cell level in the model charge-ordered system Nd 1/2 Sr 1/2 MnO 3 . In addition to imaging the prototypical site-centered charge order, we discover the nanoscale coexistence of an exotic intermediate state which mixes site and bond order and breaks inversion symmetry. We further show that nonlinear coupling of distinct lattice modes controls the selection between competing ground states. The results demonstrate the importance of lattice coupling for understanding and manipulating the character of electronic self-organization and that cryo-STEM can reveal local order in strongly correlated systems at the atomic scale.

42 ENGINEERING↗

Top-Down Fabrication of Atomic Patterns in Twisted Bilayer Graphene

Atomic-scale engineering typically involves bottom-up approaches, leveraging parameters such as temperature, partial pressures, and chemical affinity to promote spontaneous arrangement of atoms. These parameters are applied globally, resulting in atomic-scale features scattered probabilistically throughout the material. In a top-down approach, different regions of the material are exposed to different parameters, resulting in structural changes varying on the scale of the resolution. In this work, the application of global and local parameters is combined in an aberration-corrected scanning transmission electron microscope (STEM) to demonstrate atomic-scale precision patterning of atoms in twisted bilayer graphene. The focused electron beam is used to define attachment points for foreign atoms through the controlled ejection of carbon atoms from the graphene lattice. The sample environment is staged with nearby source materials such that the sample temperature can induce migration of the source atoms across the sample surface. Under these conditions, the electron-beam (top-down) enables carbon atoms in the graphene to be replaced spontaneously by diffusing adatoms (bottom-up). Using image-based feedback control, arbitrary patterns of atoms and atom clusters are attached to the twisted bilayer graphene with limited human interaction. Finally, the role of substrate temperature on adatom and vacancy diffusion is explored by first-principles simulations.

36 MATERIALS SCIENCE↗

EXTENDED Ly{alpha} EMISSION AROUND STAR-FORMING GALAXIES

Ly{alpha} photons that escape the interstellar medium of star-forming galaxies may be resonantly scattered by neutral hydrogen atoms in the circumgalactic and intergalactic media, thereby increasing the angular extent of the galaxy's Ly{alpha} emission. We present predictions of this extended, low surface brightness Ly{alpha} emission based on radiative transfer modeling in a cosmological reionization simulation. The extended emission can be detected from stacked narrowband images of Ly{alpha} emitters (LAEs) or of Lyman break galaxies (LBGs). Its average surface brightness profile has a central cusp, then flattens to an approximate plateau beginning at an inner characteristic scale below {approx}0.2 Mpc (comoving), then steepens again beyond an outer characteristic scale of {approx}1 Mpc. The inner scale marks the transition from scattered light of the central source to emission from clustered sources, while the outer scale marks the spatial extent of scattered emission from these clustered sources. Both scales tend to increase with halo mass, UV luminosity, and observed Ly{alpha} luminosity. The extended emission predicted by our simulation is already within reach of deep narrowband photometry using large ground-based telescopes. Such observations would test radiative transfer models of emission from LAEs and LBGs, and they would open a new window on the circumgalactic environment of high-redshift star-forming galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Illuminating the Material World: Autonomous Microscopy to Understand Order, Disorder, and Everything In Between

Artificial intelligence (AI) holds immense promise for revolutionizing microscopy, yet its widespread adoption has been hindered by challenges ranging from user inexperience to limited model transferability and difficulties in operationalizing machine learning. This presentation showcases our approach to developing practical autonomy for materials discovery, aiming to accelerate the integration of AI into everyday microscopy workflows. As shown in Fig. 1, I will focus on three key areas: understanding order-disorder transitions, quantifying point defects, and achieving truly device-scale microscopy. First, I will demonstrate the power of multi-modal knowledge graphs for integrating diverse microscopy data. By combining imaging, spectroscopy, and diffraction data, these graphs provide a holistic view of material behavior, capturing the intricate relationships between different modalities [1,2]. I will present a case study on how these models illuminate the structural and chemical changes associated with irradiation in oxide thin films, revealing critical insights for designing materials for extreme environments like spaceflight and nuclear energy. Specifically, I will show how multi-modal analysis clarifies the evolution of order-disorder transitions under irradiation, a key factor influencing material performance in these applications. Next, I will address the challenge of quantifying point defects in 2D materials. We demonstrate the application of computer vision and transfer learning to accurately identify and classify various defect types, such as vacancies and substitutional atoms, and to quantify their concentrations. This information is crucial for understanding and tailoring the properties of 2D materials for applications in electronics, optoelectronics, and catalysis. For example, I will show how our models can characterize the topological distribution of point defects in MXene transition metal carbides, providing valuable insights for optimizing their performance in energy storage and separation science. Finally, I will discuss our progress toward autonomous device-scale microscopy [3,4]. We are fundamentally redesigning electron microscopes around the principles of machine reasoning, enabling automation beyond basic tasks like sample navigation and data acquisition to include sophisticated experimental design. This approach paves the way for truly reproducible and massively scaled analysis campaigns. I will emphasize the importance of autonomous microscopy platforms for high-throughput materials discovery and characterization, facilitating the rapid screening of materials for a broad range of applications and accelerating the development of next-generation technologies.

36 MATERIALS SCIENCE↗

van der Waals Epitaxy, Superlubricity, and Polarization of the 2D Ferroelectric SnS

Tin monosulfide (SnS) is a two-dimensional layered semiconductor that exhibits in-plane ferroelectric order at very small thicknesses and is of interest in highly scaled devices. Here, in this study, we report the epitaxial growth of SnS on hexagonal boron nitride (hBN) using a pulsed metal-organic chemical vapor deposition process. Lattice matching is observed between the SnS($100$) and hBN{$1\bar{10}$} planes, with no evidence of strain. Atomic force microscopy reveals superlubricity along the commensurate direction of the SnS/hBN interface, and first-principles calculations suggest that friction is controlled by the edges of the SnS islands, rather than interface interactions. Differential phase contrast imaging detects remnant polarization in SnS islands with domains that are not dictated by step-edges in the SnS. The growth of ferroelectric SnS on high quality hBN substrates is a promising step toward electrically switchable ferroelectric semiconducting devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond Time-Delay X-Ray Holography

X-ray free-electron lasers (XFELs) will produce photon pulses with a unique and desirable combination of properties. Their short X-ray wavelengths allow penetration into materials and the ability to probe structure at and below the nanometer scale. Their ultra-short duration gives information about this structure at the fundamental time-scales of atoms and molecules. The extreme intensity of the pulses will allow this information to be acquired in a single shot, so that these studies can be carried out on non-repeatable processes or on weakly-scattering objects that will be modified by the pulse. A fourth property of XFEL pulses is their high transverse coherence, which brings the promise of decades of innovation in visible optics to the X-ray regime, such as holography, interferometry, and laser-based imaging. Making an effective use of XFEL pulses, however, will benefit from innovations that are new to both X-ray science and coherent optics. One such innovation is the new method of time-delay X-ray holography [1], recently demonstrated at the FLASH FEL at DESY in Hamburg, to measure the evolution of objects irradiated by intense pulses. One of the pressing questions about the high-resolution XFEL imaging and characterization of non-periodic or weakly-scattering objects is the effect of the intense FEL pulse on the object, during the interaction with that pulse. The method of single-particle diffraction imaging [2] requires a stream of reproducible particles (e.g. a protein complex or virus) inserted into the beam, whereby a coherent X-ray diffraction pattern is recorded. The pulse will completely destroy the object, but if the pulse is short enough the diffraction pattern will represent the undamaged object. This ultrafast flash imaging was demonstrated at the FLASH FEL using test objects that included microfabricated patterns in silicon nitride foils [3]. Those experiments showed that no damage occurred during the 30 fs duration pulse. However, in those experiments the imaging resolution was limited by the long 32 nm wavelength at which the facility was then operating. We wished to dramatically increase our sensitivity to the particles explosions, to be able to increase the understanding of the dynamics of particles and predict the imaging performance at XFELs such as the LCLS. This was done in two ways in a single experiment: by holographically measuring the time evolution of the particle at times after the pulse had pass through the object; and by making an interferometric measurement of the change in the optical path through the object. The experimental technique, time-delay holography, achieved a time resolution better than 3 fs, and a phase sensitivity of better than 3{sup o}, or a sensitivity of < 3 nm of the expansion of the particles.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscale Electronic Inhomogeneity in In_2Se_3 Nanoribbons Revealed by Microwave Impedance Microscopy

Driven by interactions due to the charge, spin, orbital, and lattice degrees of freedom, nanoscale inhomogeneity has emerged as a new theme for materials with novel properties near multiphase boundaries. As vividly demonstrated in complex metal oxides and chalcogenides, these microscopic phases are of great scientific and technological importance for research in hightemperature superconductors, colossal magnetoresistance effect, phase-change memories, and domain switching operations. Direct imaging on dielectric properties of these local phases,however, presents a big challenge for existing scanning probe techniques. Here, we report the observation of electronic inhomogeneity in indium selenide (In{sub 2}Se{sub 3}) nanoribbons by near-field scanning microwave impedance microscopy. Multiple phases with local resistivity spanning six orders of magnitude are identified as the coexistence of superlattice, simple hexagonal lattice and amorphous structures with {approx}100nm inhomogeneous length scale, consistent with high-resolution transmission electron microscope studies. The atomic-force-microscope-compatible microwave probe is able to perform quantitative sub-surface electronic study in a noninvasive manner. Finally, the phase change memory function in In{sub 2}Se{sub 3} nanoribbon devices can be locally recorded with big signal of opposite signs.

36 MATERIALS SCIENCE↗

Microbial Cell Imaging

Atomic force microscopy (AFM) is finding increasing application in a variety of fields including microbiology. Until the emergence of AFM, techniques for ivnestigating processes in single microbes were limited. From a biologist's perspective, the fact that AFM can be used to generate high-resolution images in buffers or media is its most appealing feature as live-cell imaging can be pursued. Imaging living cells by AFM allows dynamic biological events to be studied, at the nanoscale, in real time. Few areas of biological research have as much to gain as microbiology from the application of AFM. Whereas the scale of microbes places them near the limit of resolution for light microscopy. AFM is well suited for the study of structures on the order of a micron or less. Although electron microscopy techniques have been the standard for high-resolution imaging of microbes, AFM is quickly gaining favor for several reasons. First, fixatives that impair biological activity are not required. Second, AFM is capable of detecting forces in the pN range, and precise control of the force applied to the cantilever can be maintained. This combination facilitates the evaluation of physical characteristics of microbes. Third, rather than yielding the composite, statistical average of cell populations, as is the case with many biochemical assays, the behavior of single cells can be monitored. Despite the potential of AFM in microbiology, there are several limitations that must be considered. For example, the time required to record an image allows for the study of gross events such as cell division or membrane degradation from an antibiotic but precludes the evaluation of biological reactions and events that happen in just fractions of a second. Additionally, the AFM is a topographical tool and is restricted to imaging surfaces. Therefore, it cannot be used to look inside cells as with opticla and transmission electron microscopes. other practical considerations are the limitation on the maximum scan size (roughly 100 x 100 {mu}m) and the restricted movement of the cantilever in the Z (or height) direction. In most commercial AFMs, the Z range is restricted to roughly 10 {mu}m such that the height of cells to be imaged must be seriously considered. Nevertheless, AFM can provide structural-functional information at nanometer resolution and do so in physiologically relevant environments. Further, instrumentation for scanning probe microscopy continues to advance. Systems for high-speed imaging are becoming available, and techniques for looking inside the cells are being demonstrated. The ability to combine AFM with other imaging modalities is likely to have an even greater impact on microbiological studies. AFM studies of intact microbial cells started to appear in the literature in the 1990s. For example, AFM studies of Saccharomyces cerevisiae examined buddings cars after cell division and detailed changes related to cell growth processes. Also, the first AFM studies of bacterial biofilms appeared. In the late 1990s, AFM studies of intact fungal spores described clear changes in spore surfaces upon germination, and studies of individual bacterial cells were also described. These early bacterial imaging studies examined changes in bacterial morphology due to antimicrobial peptides exposure and bacterial adhesion properties. The majority of these early studies were carried out on dried samples and took advantage of the resolving power of AFM. The lack of cell mounting procedures presented an impediment for cell imaging studies. Subsequently, several approaches to mounting microbial cells have been developed, and these techniques are described later. Also highlighted are general considerations for microbial imaging and a description of some of the various applications of AFM to microbiology.

60 APPLIED LIFE SCIENCES↗

Charge ordering, ferroelectric, and magnetic domains in LuFe{sub 2}O{sub 4} observed by scanning probe microscopy

LuFe{sub 2}O{sub 4} is a multiferroic system which exhibits charge order, ferroelectricity, and ferrimagnetism simultaneously below ∼230 K. The ferroelectric/charge order domains of LuFe{sub 2}O{sub 4} are imaged with both piezoresponse force microscopy (PFM) and electrostatic force microscopy (EFM), while the magnetic domains are characterized by magnetic force microscopy (MFM). Comparison of PFM and EFM results suggests that the proposed ferroelectricity in LuFe{sub 2}O{sub 4} is not of usual displacive type but of electronic origin. Simultaneous characterization of ferroelectric/charge order and magnetic domains by EFM and MFM, respectively, on the same surface of LuFe{sub 2}O{sub 4} reveals that both domains have irregular patterns of similar shape, but the length scales are quite different. The domain size is approximately 100 nm for the ferroelectric domains, while the magnetic domain size is much larger and gets as large as 1 μm. We also demonstrate that the origin of the formation of irregular domains in LuFe{sub 2}O{sub 4} is not extrinsic but intrinsic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗