Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Dynamic Beam Solutions for Real-Time Simulation and Control Development of Flexible Rockets

In this study, flexible rockets are structurally represented by linear beams. Both direct and indirect solutions of beam dynamic equations are sought to facilitate real-time simulation and control development for flexible rockets. The direct solution is completed by numerically integrate the beam structural dynamic equation using an explicit Newmark-based scheme, which allows for stable and fast transient solutions to the dynamics of flexile rockets. Furthermore, in the real-time operation, the bending strain of the beam is measured by fiber optical sensors (FOS) at intermittent locations along the span, while both angular velocity and translational acceleration are measured at a single point by the inertial measurement unit (IMU). Another study in this paper is to find the analytical and numerical solutions of the beam dynamics based on the limited measurement data to facilitate the real-time control development. Numerical studies demonstrate the accuracy of these real-time solutions to the beam dynamics. Such analytical and numerical solutions, when integrated with data processing and control algorithms and mechanisms, have the potential to increase launch availability by processing flight data into the flexible launch vehicle's control system.

flexible body dyanmics fiber optic strain sensor p↗

SU-E-T-456: Development of An EPID-Based Output Measurement and Dosimetric Verification Tool for Electron Beam Therapy

Purpose: To develop an efficient and robust method for output and absolute dosimetric measurements of electron beam therapy by using a high spatialresolution and high frame-rate amorphous silicon flat-panel electronic portal imaging device (EPID). Methods: A previously-established EPID dosimetry system was extended to measure the output factors of electron beams of various sizes and their planar dose distributions at reference depths. Specific EPID responses to different electron energies were derived from Monte Carlo (MC) simulations to de-convolve the EPID raw images to the incident electron fluence map. To reconstruct the 2D water-based dose distribution map at reference depths for different energies, the fluence map was further convolved with a MC simulated pencil beam kernel. Different energies of 6, 9, 12, 16, and 20 MeV from a Varian C-series linac were tested. Standard square fields ranging from 2×2 to 15×15 cm{sup 2} were measured and validated against film/ion chamber measurements. Small fields of different patient cases with irregular cutout shapes were also tested. Results: The EPIDmeasured output factors for 2×2, 3×3, 6×6, and 10×10 cm{sup 2} fields with all electron energies agree with the film/ion chamber data within 2.7%. The average discrepancy between EPID and film/ion chamber measurements was 1.4%. The differences for the three patient cases were 0.1%, 2.1%, and 1.6%. Deliveries with different monitor units were tested and the results exhibited good linearity. Measurements with different dose rate showed that the dose rate dependence was less than 1%. Using the proposed method, 2D absolute dose maps were created from the EPID raw images and the results were consistent with film measurements. Conclusion: The efficient data readout and portability of the newly developed EPID system provides an efficient and accurate solution for electron beam therapy. It addresses an important unmet clinical need for a fast and reliable small field output factor measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Recent progress in plasma modelling at INFN-LNS

At Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali del Sud (INFN-LNS), the development of intense ion and proton sources has been supported by a great deal of work on the modelling of microwave generated plasmas for many years. First, a stationary version of the particle-in-cell code was developed for plasma modelling starting from an iterative strategy adopted for the space charge dominated beam transport simulations. Electromagnetic properties of the plasma and full-waves simulations are now affordable for non-homogenous and non-isotropic magnetized plasma via “cold” approximation. The effects of Coulomb collisions on plasma particles dynamics was implemented with the Langevin formalism, instead of simply applying the Spitzer 90° collisions through a Monte Carlo technique. A wide database of different cross sections related to reactions occurring in a hydrogen plasma was implemented. The next step consists of merging such a variety of approaches for retrieving an “as-a-whole” picture of plasma dynamics in ion sources. The preliminary results will be summarized in the paper for a microwave discharge ion source designed for intense and high quality proton beams production, proton source for European Spallation Source project. Even if the realization of a predictive software including the complete processes involved in plasma formation is still rather far, a better comprehension of the source behavior is possible and so the simulations may support the optimization phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics near equilibrium for intense beams in a nonlinear integrable focusing channel

Accelerator storage ring designs based on nonlinear integrable Hamiltonian systems provide a novel test-bed for studying the interplay between nonlinear dynamics and space charge at high intensity. In this work, the structure of beam Vlasov equilibria is explored for a constant focusing channel based on the nonlinear focusing potential of the Integrable Optics Test Accelerator. Finally, the dynamics of the single-particle orbits is explored in the combined space charge and external focusing fields as a function of beam current, and the self-consistent relaxation of a mismatched beam to equilibrium is characterized.

43 PARTICLE ACCELERATORS↗

TU-CD-304-06: Using FFF Beams Improves Tumor Control in Radiotherapy of Lung Cancers

Purpose: Electron disequilibrium at the lung-tumor interface results in an under-dosage of tumor regions close to its surface. This under-dosage is known to be significant and can compromise tumor control. Previous studies have shown that in FFF beams, disequilibrium effects are less pronounced, which is manifested in an increased skin dose. In this study we investigate the improvement in tumor dose coverage that can be achieved with FFF beams. The significance of this improvement is evaluated by comparing tumor control probabilities of FFF beams and conventional flattened beams. Methods: The dosimetric coverage was investigated in a virtual phantom representing the chest wall, lung tissue and the tumor. A range of tumor sizes was investigated, and two tumor locations – central and adjacent to the chest wall. Calculations were performed with BEAMnrc Monte Carlo code. Parallel-opposed and multiple coplanar 6-MV beams were simulated. The tumor control probabilities were calculated using the logistic model with parameters derived from clinical data for non-small lung cancer patients. Results: FFF beams were not entirely immune to disequilibrium effects. They nevertheless consistently delivered more uniform dose distribution throughout the volume of the tumor, and eliminated up to ∼15% of under-dosage in the most affected by disequilibrium 1-mm thick surface region of the tumor. A voxel-by-voxel comparison of tumor control probabilities between FFF and conventional flattened beams showed an advantage of FFF beams that, depending on the set up, was from a few to ∼9 percent. Conclusion: A modest improvement in tumor control probability on the order of a few percent can be achieved by replacing conventional flattened beams with FFF beams. However, given the large number of lung cancer patients undergoing radiotherapy, these few percent can potentially prevent local tumor recurrence for a significant number of patients.

60 APPLIED LIFE SCIENCES↗

Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations

Purpose: The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a linear accelerator.Methods: In order to properly characterize beams from the integrated kV CBCT system, the authors have adapted a previously developed equivalent source model consisting of an equivalent spectrum module that takes into account intrinsic filtration and an equivalent filter module characterizing the added bowtie filtration. An equivalent spectrum was generated for an 80, 100, and 125 kVp beam with beam energy characterized by half-value layer measurements. An equivalent filter description was generated from bowtie profile measurements for both the full- and half-bowtie. Equivalent source models for each combination of equivalent spectrum and filter were incorporated into the Monte Carlo software package MCNPX. Monte Carlo simulations were then validated against in-phantom measurements for both the radiographic and CBCT mode of operation of the kV CBCT system. Radiographic and CBCT imaging dose was measured for a variety of protocols at various locations within a body (32 cm in diameter) and head (16 cm in diameter) CTDI phantom. The in-phantom radiographic and CBCT dose was simulated at all measurement locations and converted to absolute dose using normalization factors calculated from air scan measurements and corresponding simulations. The simulated results were compared with the physical measurements and their discrepancies were assessed quantitatively.Results: Strong agreement was observed between in-phantom simulations and measurements. For the radiographic protocols, simulations uniformly underestimated measurements by 0.54%–5.14% (mean difference =−3.07%, SD = 1.60%). For the CBCT protocols, simulations uniformly underestimated measurements by 1.35%–5.31% (mean difference =−3.42%, SD = 1.09%).Conclusions: This work demonstrates the feasibility of using a measurement-based kV CBCT source model to facilitate dose calculations with Monte Carlo methods for both the radiographic and CBCT mode of operation. While this initial work validates simulations against measurements for simple geometries, future work will involve utilizing the source model to investigate kV CBCT dosimetry with more complex anthropomorphic phantoms and patient specific models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-A-BRD-10: A Fast and Accurate GPU-Based Proton Transport Monte Carlo Simulation for Validating Proton Therapy Treatment Plans

Purpose: To build a GPU-based Monte Carlo (MC) simulation of proton transport with detailed modeling of elastic and non-elastic (NE) protonnucleus interactions, for use in a very fast and cost-effective proton therapy treatment plan verification system. Methods: Using the CUDA framework, we implemented kernels for the following tasks: (1) Simulation of beam spots from our possible scanning nozzle configurations, (2) Proton propagation through CT geometry, taking into account nuclear elastic and multiple scattering, as well as energy straggling, (3) Bertini-style modeling of the intranuclear cascade stage of NE interactions, and (4) Simulation of nuclear evaporation. To validate our MC, we performed: (1) Secondary particle yield calculations in NE collisions with therapeutically-relevant nuclei, (2) Pencil-beam dose calculations in homogeneous phantoms, (3) A large number of treatment plan dose recalculations, and compared with Geant4.9.6p2/TOPAS. A workflow was devised for calculating plans from a commercially available treatment planning system, with scripts for reading DICOM files and generating inputs for our MC. Results: Yields, energy and angular distributions of secondaries from NE collisions on various nuclei are in good agreement with the Geant4.9.6p2 Bertini and Binary cascade models. The 3D-gamma pass rate at 2%–2mm for 70–230 MeV pencil-beam dose distributions in water, soft tissue, bone and Ti phantoms is 100%. The pass rate at 2%–2mm for treatment plan calculations is typically above 98%. The net computational time on a NVIDIA GTX680 card, including all CPU-GPU data transfers, is around 20s for 1×10{sup 7} proton histories. Conclusion: Our GPU-based proton transport MC is the first of its kind to include a detailed nuclear model to handle NE interactions on any nucleus. Dosimetric calculations demonstrate very good agreement with Geant4.9.6p2/TOPAS. Our MC is being integrated into a framework to perform fast routine clinical QA of pencil-beam treatment plans. Hardware for such a system will cost under $5000. This work was funded in part by a grant from Varian Medical Systems, Inc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent Developments in Simulations of an Inverse Cyclotron for Intense Muon Beams

A number of recent developments have led to simulations of an inverse cyclotron for cooling intense muon beams for neutrino factories and muon colliders. Such a device could potentially act as a novel beam cooling mechanism for muons, and it would be significantly smaller and cheaper than other cooling channel designs. Realistic designs are still being explored, but the first simulations of particle tracking in the inverse cyclotron, with accumulation in the cyclotron core, have been done with electrostatic simulations in the particle-in-cell code VORPAL. We present an overview of the muon inverse cyclotron concept and recent simulation results.

43 PARTICLE ACCELERATORS↗

Theoretical Approach Of The Reduction Of Chromatic And Spherical Aberrations In An Acceleration Lens System For Hundreds Of keV Gaseous Ion Nanobeam

The focused gaseous ion beam (gas-FIB) system composed of a series of electrostatic lenses, called ''acceleration lens system'', has been developed to form nanobeams using gaseous ions generated from a plasma ion source. Ion beams are accelerated and focused simultaneously by a pair of electrodes. A new all-in-one compact acceleration system including an acceleration tube is now under development to form 300 keV ion nanobeam. Chromatic and spherical aberrations are, however, hindrance to form nanobeams with their smaller sizes in diameter. A deceleration lens, which performs like a defocusing lens, was theoretically introduced to downstream of the present acceleration lens system to reduce the aberrations. Ion beam optics simulations were carried out to show that this aberration reduction technique is effective to reduce chromatic and spherical aberrations. As a result, we reduced the chromatic aberration coefficient by 26%, the spherical aberration coefficient by 17% and a beam diameter by 17%, with the deceleration energy of 15 keV. In case of using an electrostatic acceleration tube with 100 mm length, the final beam diameter of 103 nm at 300 keV is obtained by the all-in-one acceleration lens system with the total acceleration length of only 650 mm.

43 PARTICLE ACCELERATORS↗

Simulations of Field-Emission Electron Beams from CNT Cathodes in RF Photoinjectors

Average field emission currents of up to 700 mA were produced by Carbon Nano Tube (CNT) cathodes in a 1.3 GHz RF gun at Fermilab High Brightness Electron Source Lab. (HBESL). The CNT cathodes were manufactured at Xintek and tested under DC conditions at RadiaBeam. The electron beam intensity as well as the other beam properties are directly related to the time-dependent electric field at the cathode and the geometry of the RF gun. This report focuses on simulations of the electron beam generated through field-emission and the results are compared with experimental measurements. These simulations were performed with the time-dependent Particle In Cell (PIC) code WARP.

43 PARTICLE ACCELERATORS↗

Note on numerical study of the beam energy spread in NDCX-I

The kinetic energy spread (defined here as the standard deviation of the beam particle energies) sets the ultimate theoretical limit on the longitudinal compression that can be attained on NDCX-I and NDCX-II. Experimental measurements will inevitably include the real influences on the longitudinal phase space of the beam due to injector and accelerator field imperfections1. These induced energy variations may be the real limit to the longitudinal compression in an accelerator. We report on a numerical investigation of the energy spread evolution in NDCX-I; these studies do not include all the real imperfections, but rather are intended to confirm that there are no other intrinsic mechanisms (translaminar effects, transverse-longitudinal anisotropy instability, etc.) for significant broadening of the energy distribution. We have performed Warp simulations that use a realistic Marx voltage waveform which was derived from experimental measurements (averaged over several shots), a fully-featured model of the accelerating and focusing lattice, and new diagnostics for computing the local energy spread (and temperature) that properly account for linear correlations that arise from the discrete binning along each physical dimension (these capabilities reproduce and extend those of the earlier HIF code BPIC). The new diagnostics allow for the calculation of multi-dimensional maps of energy spread and temperature in 2-D axisymmetric or 3-D Cartesian space at selected times. The simulated beam-line was terminated at z = 3 m by a conducting plate, so as to approximately reproduce the experimental conditions at the entrance of the spectrometer that was used for mapping the longitudinal phase space. Snapshots of the beam projection and current, as well as the Marx waveform and history of beam kinetic energy collected at the end plate, are shown in Fig. 1. A two-dimensional axisymmetric map of energy spread from simulations of a typical NDCX-I configuration is shown in Fig. 2 (a). The energy spread starts at 0.1 eV at the source and rapidly rises to a few eV, then fluctuates between a fraction of an eV and tens of eV, ending near the exit in a range of a few eV at the outer edge of the beam to a few tens of eV near the axis. The higher value on-axis is associated with greater numerical noise there, due to the axisymmetric geometry of the calculation, resulting in poorer simulation-particle statistics at small radius. A scatter plot of the macroparticles kinetic energy (KE) versus radius (R) and longitudinal position (0.28 m < z < 3 m) colored by local energy spread is shown in Fig. 2 (b). As expected, there is a correlation of the kinetic energy with radius that is clearly visible at z = 2.8 m and vanishes at the metal plate at z = 3 m. More snapshots from simulations varying the time step, grid resolution and number of macroparticles are given in Appendix II. The macro-particles were collected at the exit plate and their kinetic energy history is plotted in Fig. 3 (left) and contrasted to an experimental measurement using a streak camera shown in Fig. 3. For some types of measurements, averaging over several pulses to improve signal-to-noise will contribute an additional spread that may not be present on any single beam pulse. The upper bound for the energy spread is in the range of a few 100 eV for the experiment while in the range of a few eV for the reported Warp simulations. The Marx voltage exhibits variations in the range of up to several hundreds of volts, playing a significant role in the experimentally measured energy spread, which may account for the difference between the experimental and the simulated bounds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interlaboratory Reproducibility of Contour Method Data Analysis and Residual Stress Calculation

While the contour method for residual stress assessment has developed rapidly, no published study documents its interlaboratory reproducibility. Objective: Here we report an initial reproducibility experiment focused on contour method data analysis and residual stress calculation. The experiment uses surface topography data from a physical process simulation of elastic-plastic beam bending. The simulation provides surface topography, for input to the contour method data analysis, as well as a known residual stress field with 130 MPa peak magnitude. Additionally, to increase realism, noise and specific artifacts are added to the topography data. A group of participants received the topography data (without the known residual stress), independently analyzed the data, and submitted results as a two-dimensional residual stress field. Analysis of submissions provides a group average residual stress field and the spatial distribution of reproducibility standard deviation. The group average residual stress agrees with the known stress in magnitude and spatial trend. The reproducibility standard deviation ranges from 2 to 54 MPa over the measurement plane, with an average of 5.4 MPa. Reproducibility standard deviation is smaller in the cross-section interior (≤ 5 MPa), modest near local extrema in the stress field (5 to 10 MPa), and larger near the cross-section boundaries (10 to 30 MPa). Overall, the largest values of reproducibility standard deviation (up to 54 MPa) occur in limited areas where artifacts had been added to the topography data; while some participants identified and removed these artifacts, some did not, leading to systematic differences that elevated the standard deviation.

42 ENGINEERING↗

Nozzle geometry optimization for high-current aluminum ion beam acceleration via direct plasma injection scheme

We report the generation of a record aluminum ion beam current exceeding 58 mA at the Al 11+ charge state, accelerated to an energy of 5.5 MeV using the direct plasma injection scheme, which integrates a laser ion source (LIS) with a radio frequency quadrupole (RFQ) accelerator. The effect of nozzle geometry on beam extraction was systematically investigated using 8 and 12 mm tapered designs and an 18 mm cylindrical configuration. The 18 mm nozzle achieved the highest Al 11+ beam current, while the 12 mm aperture provided a favorable balance between beam intensity and current density. Beam extraction simulations confirmed effective RFQ matching across multiple charge states, and solenoidal field tuning further enhanced plasma collimation. This work not only establishes a new benchmark for high-current ion beam generation but also provides a fundamental understanding of plasma–beam interface dynamics crucial for the next generation of high-intensity particle accelerators, particularly those employing LIS-RFQ systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs

The wavefront preservation of coherent X-ray free-electron laser beams is pushing the requirement on the quality and performance of X-ray optics to an unprecedented level. The Strehl ratio can be used to quantify this requirement. In this paper, the criteria for thermal deformation of the X-ray optics are formulated, especially for crystal monochromators. To preserve the X-ray wavefront, the standard deviation of the height error should be sub-nm for mirrors and less than 25 pm for crystal monochromators. Cryocooled silicon crystals combined with two techniques can be used to achieve this level of performance for monochromator crystals: (1) using a focusing element to compensate the second-order component of the thermal deformation; (2) introducing a cooling pad between the cooling block and silicon crystal and optimizing the effective cooling temperature. Each of these techniques allows the thermal deformation in standard deviation of the height error to be reduced by an order of magnitude. As an example, for the LCLS-II-HE Dynamic X-ray Scattering instrument, the criteria on thermal deformation of a high-heat-load monochromator crystal can be achieved for a 100 W SASE FEL beam. Wavefront propagation simulations confirm that the reflected beam intensity profile is satisfactory on both the peak power density and focused beam size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Simulation Study of Multi-Beam Altimetry for Lunar Reconnaissance Orbiter and Other Planetary Missions

The combined use of altimetry, Earth-based Doppler and Earth-based range measurements in the lunar reconnaissance orbiter (LRO) mission (Chin et al. in Space Sci Rev 129:391-419, 2007) has been examined in a simulation study. It is found that in the initial phases of the mission orbit and altimeter geolocation accuracies should be better than 10m in the radial component and 60m overall. It is demonstrated that LRO's precise 1-way laser range measurement from Earth-based stations (Smith et al. in Proceedings of the 15th International Laser Ranging Workshop, Canberra, Australia, October 15-20, 2006) will be useful for gravity recovery. The advantages of multiple laser beams are demonstrated for altimeter calibration, orbit determination and gravity recovery in general planetary settings as well as for LRO.

Rowlands, D. D.↗

Artificial ion beam instabilities. I - Linear theory. II - Simulations

Some of the important plasma instabilities that result when an artificial ion beam is injected into the ionospheric F region are studied using linear Vlasov theory. The variation in wave spectra at the receiver as the receiver and plasma gun separate perpendicularly to the magnetic field is consistent with a beam density decrease at or near the receiver. At separation distances that are large fractions of the beam gyrodiameter, usually narrow-band waves near the background lower hybrid and H+ gyroharmonic frequencies are measured. These observations are consistent with waves expected to be generated by beam densities on the order of or less than a few percent of the background density. At smaller separation distances, broadband waves are usually observed with frequencies from zero up to and above the lower hybrid frequency. Electrostatic particle simulation studies of the plasma instabilities indicate that the broadband fluidlike lower hybrid instability is the most important for background particle heating. Perpendicular H+ heating is more efficient than perpendicular O+ or parallel electron heating for the drift velocity regime most relevant to past experiments.

Scales, W. A.↗

Stable long range proton acceleration driven by intense laser pulse with underdense plasmas

Proton acceleration is investigated by 2.5-dimensional particle-in-cell simulations in an interaction of an ultra intense laser with a near-critical-density plasma. It was found that multi acceleration mechanisms contribute together to a 1.67 GeV collimated proton beam generation. The W-BOA (breakout afterburner based on electrons accelerated by a wakefield) acceleration mechanism plays an important role for the proton energy enhancement in the area far from the target. The stable and continuous acceleration maintains for a long distance and period at least several pico-seconds. Furthermore, the energy scalings are also discussed about the target density and the laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗