A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study report on laser storage and retrieval of image data

The theoretical foundation is presented for a system of real-time nonphotographic and nonmagnetic digital laser storage and retrieval of image data. The system utilizes diffraction-limited laser focusing upon thin metal films, melting elementary holes in the metal films in laser focus. The metal films are encapsulated in rotating flexible mylar discs which act as the permanent storage carries. Equal sized holes encompass two dimensional digital ensembles of information bits which are time-sequentially (bit by bit) stored and retrieved. The bits possess the smallest possible size, defined by the Rayleigh criterion of coherent physical optics. Space and time invariant reflective read-out of laser discs with a small laser, provides access to the stored digital information. By eliminating photographic and magnetic data processing, which characterize the previous state of the art, photographic grain, diffusion, and gamma-distortion do not exist. Similarly, magnetic domain structures, magnetic gaps, and magnetic read-out are absent with a digital laser disc system.

Becker, C. H.↗

Common path point diffraction interferometer using liquid crystal phase shifting

A common path point diffraction interferometer uses dyed, parallel nematic liquid crystals which surround an optically transparent microsphere. Coherent, collimated and polarized light is focused on the microsphere at a diameter larger than that of the microsphere. A portion of the focused light passes through the microsphere to form a spherical wavefront reference beam and the rest of the light is attenuated by the dyed liquid crystals to form an object beam. The two beams form an interferogram which is imaged by a lens onto an electronic array sensor and into a computer which determines the wavefront of the object beam. The computer phase shifts the interferogram by stepping up an AC voltage applied across the liquid crystals without affecting the reference beam.

Mercer, Carolyn R.↗

Image transformation caused by wide-angle acousto-optic interaction

The problem of diffraction of divergent image-transfer light beams by an acoustic wave is considered. Expressions that describe the transfer function as a function of spectral and angular coordinates and are valid for any birefringence are obtained for the first time. The main characteristics of wide-angle acousto-optic tunable filters (angular and spectral bandwidths) are calculated and compared with the experimental data. The dependence of the transfer function on the angle of light incidence is investigated and a fundamental change in its topology is shown. (acoustooptics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three dimensional full-wave nonlinear acoustic simulations: Applications to ultrasound imaging

Characterization of acoustic waves that propagate nonlinearly in an inhomogeneous medium has significant applications to diagnostic and therapeutic ultrasound. The generation of an ultrasound image of human tissue is based on the complex physics of acoustic wave propagation: diffraction, reflection, scattering, frequency dependent attenuation, and nonlinearity. The nonlinearity of wave propagation is used to the advantage of diagnostic scanners that use the harmonic components of the ultrasonic signal to improve the resolution and penetration of clinical scanners. One approach to simulating ultrasound images is to make approximations that can reduce the physics to systems that have a low computational cost. Here a maximalist approach is taken and the full three dimensional wave physics is simulated with finite differences. This paper demonstrates how finite difference simulations for the nonlinear acoustic wave equation can be used to generate physically realistic two and three dimensional ultrasound images anywhere in the body. A specific intercostal liver imaging scenario for two cases: with the ribs in place, and with the ribs removed. This configuration provides an imaging scenario that cannot be performed in vivo but that can test the influence of the ribs on image quality. Several imaging properties are studied, in particular the beamplots, the spatial coherence at the transducer surface, the distributed phase aberration, and the lesion detectability for imaging at the fundamental and harmonic frequencies. The results indicate, counterintuitively, that at the fundamental frequency the beamplot improves due to the apodization effect of the ribs but at the same time there is more degradation from reverberation clutter. At the harmonic frequency there is significantly less improvement in the beamplot and also significantly less degradation from reverberation. It is shown that even though simulating the full propagation physics is computationally challenging it is necessary to quantify ultrasound image quality and its sources of degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of reactive gas (oxygen/chlorine/fluorine) etching on the magnetic flux of a high moment write pole material

Effect of reactive gas (oxygen/chlorine/fluorine) etching on NiFe magnetic properties was investigated. Experimental data showed 40% magnetic property degradation for F-containing gas etching, 10% degradation for O-containing gas etching, and 5% degradation for Cl-containing gas etching processes. X-ray diffraction analysis indicated that the crystallographic orientation remained the same upon the reactive gas etching, which is due to the low ion energy in plasma etching process as opposed to ion milling process with high input energy. It is proposed that the reported magnetic property degradation was mainly caused by the nonmagnetic dead layer formation, rather than the changes in the crystallographic orientation. The dead layer was determined by the NiFe thickness dependence of remnant magnetic flux variations between pre-etched and postetched samples. The dead layer remained nearly constant for O-containing gas etching process with increasing plasma processing time. The nonmagnetic dead layer of {approx}40-50 A formed in O-containing etching gas was observed in transmission electron microscopy cross-sectional image and was in very good agreement with the calculated value based on magnetic flux measurements. Combined magnetic and physical characterizations suggest that the dead layer thickness saturates at the initial stage of the plasma etching and magnetic property remained unchanged with increasing etching duration upon formation of the dead layer.

36 MATERIALS SCIENCE↗

Synthesis and Thermoelectric Properties of low-x Bi{sub 2}Se{sub 3-x}S{sub 3} Series

Bi{sub 2}Se{sub 3}-xS{sub x} solid solutions, with low x values, were synthesized from melt. The solid solutions were studied in terms of phase purity using powder X-ray diffraction (PXRD) in order to find the maximum x value for the preservation of the single Bi2Se3-type phase. The lattice parameters were estimated and showed the reduced unit cell with the S incorporation in the lattice. SEM images confirmed the plate-like morphology of the Bi{sub 2}Se{sub 3}-xS{sub x} single-phase members. The thermoelectric properties (Seebeck coefficient and electrical conductivity) as well as IR reflectivity were also studied on members with x<0.4 that were found to form single phase Bi{sub 2}Se{sub 3}-xS{sub x} solid solutions.

36 MATERIALS SCIENCE↗

Synergic grain boundary segregation and precipitation in W- and W-Mo-containing high-entropy borides

The structures of W- and W-Mo-containing high-entropy borides (HEBs) are systematically studied by combining atomic-resolution transmission electron microscopy imaging, electron diffraction, and chemical analysis. Here, we reveal that W or W-Mo addition in HEBs leads to segregation of these elements to the grain boundaries (GBs). In the meantime, W- or W-Mo-rich precipitates also form along the GBs. Crystallographic analysis and atomic-scale imaging show that the GB precipitates in both W- and W-Mo-containing HEBs have a cube-on-cube orientation relationship with the matrix. With further strain analysis, the coherency of the precipitate/matrix interface is validated. Nanoindentation tests show that the simultaneous GB segregation and coherent precipitation, as a supplement to the grain hardening, provide additional hardening of the HEBs. Our work provides an in-depth understanding of the GB segregation and precipitation behaviors of HEBs. It suggests that GB engineering could be potentially used for optimizing the performance of high-entropy ceramics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of Hard X-ray Imaging Optics with Two Pairs of Elliptical and Hyperbolic Mirrors

To form a magnified hard X-ray image with a 50 nm resolution, we have studied total reflection mirror optics with two pairs of elliptical and hyperbolic mirrors, which is called 'Advanced Kirkpatrick-Baez system'. A designed optical system has 200x and 300x magnifications in vertical and horizontal directions. Also diffraction limit size in the optical system is 40 nmx45 nm. We fabricated a pair of elliptical and hyperbolic mirrors for horizontal imaging with a figure accuracy of 2 nm using elastic emission machining (EEM), microstitching interferometry (MSI) and relative-angle-determinable stitching interferometry (RADSI). One-dimensional tests for forming a demagnified image of a slit were carried out at an X-ray energy of 11.5 keV at BL29XUL (EH2) of SPring-8. As a result, a shape beam with a FWHM of 78 nm was observed. This demonstrates that we realized one-dimensional Wolter optics that has a spatial resolution of 78 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Second-order Talbot self-imaging with pseudothermal light

The second-order Talbot effect with thermal light is both theoretically and experimentally investigated. Three kinds of experimental schemes are performed, one of which reproduces the classical Talbot self-imaging and the others show plentiful self-imaging effects, in which an object with a periodic structure can be enlarged or diminished. The theoretical analysis, in good agreement with the experimental results, testifies that the specificity in the second-order Talbot effect refers to the joint diffraction of two correlated beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Growth modes of ZnO nanostructures from laser ablation

ZnO nanowires (NWs) and other nanostructures were grown by laser ablation of a ZnO containing target onto different substrates with and without the presence of an Au catalyst. The morphology and structure of the NWs were studied using high resolution scanning and transmission electron microscopes [including imaging, selected area electron diffraction (SAED), and energy dispersive x-ray spectroscopy (EDS)]. The different growth modes obtainable could be tuned by varying the Zn concentration in the vapor phase keeping other growth parameters intact. Possible growth mechanisms of these nanowires are suggested and discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Direct low-temperature synthesis of RB{sub 6} (R=Ce, Pr, Nd) nanocubes and nanoparticles

Rare-earth hexaborides (RB{sub 6}, R=Ce, Pr, Nd) nanocrystals were prepared by a facile solid state reaction in an autoclave. Single-crystalline RB{sub 6} nanocubes were fabricated at 500 deg. C starting from B{sub 2}O{sub 3}, RCl{sub 3}.6H{sub 2}O and Mg powder. RB{sub 6} nanoflakes and nanoparticles could be obtained around 400 deg. C using NaBH{sub 4} as boron resource. XRD patterns show that all of the hexaborides are cubic phase with high crystallinity and high purity and have lattice parameters that are consistent with nearly stoichiometric products. Raman spectra elucidate the active vibrational modes of the hexaborides. The TEM and FESEM images clearly show that the nanocubes have an average size of 200 nm and nanoparticles of 30 nm. Our experiment developed an efficient, simple and low-cost route to prepare RB{sub 6}, which could be extended further to the preparation of other rare-earth metal hexaborides. - Graphical abstract: FESEM images of CeB{sub 6} nanocubes prepared at 500 deg. C for 12 h using B{sub 2}O{sub 3} as boron resource.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Strain and magnetic anisotropy of as-grown and annealed Fe films on c(4x4) reconstructed GaAs (001) surface

Fe films with the different thicknesses were grown on c(4x4) reconstructed GaAs (001) surfaces at low temperature by molecular-beam epitaxy. Well-ordered bcc structural Fe epitaxial films are confirmed by x-ray diffraction patterns and high-resolution cross-sectional transmission electron microscopy images. A large lattice expansion perpendicular to the surface in Fe film is observed. In-plane uniaxial magnetic anisotropy is determined by the difference between magnetizing energy along [110] and [110] directions, and the constant of interfacial uniaxial magnetic anisotropy is calculated to be 1.02x10{sup -4} J m{sup -2}. We also find that magnetic anisotropy is not obviously influenced after in situ annealing, but in-plane strain is completely changed.

36 MATERIALS SCIENCE↗

Combined electron backscatter diffraction and cathodoluminescence measurements on CuInS{sub 2}/Mo/glass stacks and CuInS{sub 2} thin-film solar cells

Electron backscatter diffraction (EBSD) and cathodoluminescence (CL) measurements in a scanning electron microscope were performed on cross sections of CuInS{sub 2} thin films and ZnO/CdS/CuInS{sub 2}/Mo/glass thin-film solar cells. The CuInS{sub 2} layers analyzed for the present study were grown by a rapid thermal process. The regions of the CuInS{sub 2} layers emitting high CL intensity of band-band luminescence are situated near the top surface (or close to the interface with ZnO/CdS). This can be attributed to an enhanced crystal quality of the thin films in this region. The phenomenon may be related to the recrystallization via solid-state reactions with Cu{sub x}S phases, which is assumed to run from the top to the bottom of the growing CuInS{sub 2} layer. The distribution of CL intensities is independent of the sample temperature, the acceleration voltage of the electron beam, and of whether or not the ZnO/CdS window layers are present. When comparing CL images and EBSD maps on identical sample positions, pronounced intragrain CL contrast is found for individual grains. Also, it is shown that at random grain boundaries, the decreases in CL intensities are substantially larger than at {Sigma}3 grain boundaries.

36 MATERIALS SCIENCE↗

Hydrothermal synthesis and electrochemical performance of NiO microspheres with different nanoscale building blocks

NiO microspheres were successfully obtained by calcining the Ni(OH){sub 2} precursor, which were synthesized via the hydrothermal reaction of nickel chloride, glucose and ammonia. The products were characterized by TGA, XRD and SEM. The influences of glucose and reaction temperature on the morphologies of NiO samples were investigated. Moreover, the possible growth mechanism for the spherical morphology was proposed. The charge/discharge test showed that the as-prepared NiO microspheres composed of nanoparticles can serve as an ideal electrode material for supercapacitor due to the spherical hollow structure. -- Graphical Abstract: Fig. 5 is the SEM image of NiO that was prepared in the different hydrothermal reaction temperatures. It showed that reaction temperature played a crucial role for the morphology of products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Diffraction Study of Two- and Three-dimensional Defects in Bi{sub 12}SiO{sub 20} Crystals

Specimens of Bi{sub 12}SiO{sub 20}(BSO) crystals oriented along <001>, <011> and <111> were examined by electron diffraction and various two- and three-dimensional defects were characterized. Low- angle misoriented sub-grains were found along the [001] and the [111] zone axes. The observed weak reflections elongation along <001> and <011> is attributed to some kind of stacking faults lying in planes perpendicular to these directions. We discuss a complex image of the electron diffraction patterns observed along the [011] zone axis and conclude that these patterns are caused by a second-phase inclusion consisting of BSO, meta-stable phase Bi{sub 2}SiO{sub 5} and SiO{sub 2}.

36 MATERIALS SCIENCE↗

Anti-contamination device for cryogenic soft X-ray diffraction microscopy

Cryogenic microscopy allows one to view frozen hydrated biological and soft matter specimens with good structural preservation and a high degree of stability against radiation damage. We describe a liquid nitrogen-cooled anti-contamination device for cryogenic X-ray diffraction microscopy. The anti-contaminator greatly reduces the buildup of ice layers on the specimen due to condensation of residual water vapor in the experimental vacuum chamber. We show by coherent X-ray diffraction measurements that this leads to fivefold reduction of background scattering, which is important for far-field X-ray diffraction microscopy of biological specimens.

36 MATERIALS SCIENCE↗