Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Fabrication of carbon film composites for high-strength structures

Physical and mechanical properties of fiber composite materials consisting of carbon films are described. Application of carbon film structural composites for constructing microwave filters or optical instruments is proposed. Applications in aerospace and architectural structures for high strength and low density properties are discussed.

Preiswerk, P. R.↗

Experimental system for the control of surgically induced infections

The experimental system is described, and the procedures for surgery usage and maintenance are outlined. Basically the system consists of the following: (1) a portable clean room comprised of a horizontal laminar flow filter system and a transparent walled enclosure, (2) a helmet-shoulder pad assembly, (3) a communications system, (4) a helmet ventilation system, and (5) surgical gowns.

Source record↗

Linear restoration of incoherently radiating objects.

Light from an incoherently radiating object and background light are focused onto a photosensitive mosaic, the currents from whose elements constitute the data on which is based a least-squares linear estimate of the radiance at points in the object. By comparison of the mean-square error with that given by Wiener filtering theory, the equivalent noise spectral density for use in the latter is shown to consist of a shot-noise term and a term due to the random fluctuations of the incoherent light; the former predominates under most circumstances. Turbulent distortion of the image after passage of the rays through a random-phase screen is also treated from this standpoint.

Helstrom, C. W.↗

Supervisory sampling and control: Sources of suboptimality in a prediction task

A process supervisor is defined as a person who decides when to sample the process input and what values of a control variable to specify in order to maximize (minimize) a given value function of input sampling period, control setting, and process state. Presented experimental data in such a process where the value function is a time-averaged sampling cost plus mean squared difference between input and control variable. The task was unpaced prediction of the output of a second order filter driven by white noise. Experimental results, when compared to the optical strategy, reveal several consistently suboptimal behaviors. One is a tendency not to choose a long prediction interval even though the optimal strategy dictates that one should. Some results are also interpreted in terms of those input parameters according to which each subjects' behavior would have been nearest optimal. Differences of those parameters from actual input parameters served to quantify how subjects' prediction behavior differed from optimal.

Sheridan, T. B.↗

International Planetary Patrol observations of Saturn's rings. I - Observations and data reduction

The paper describes the reduction procedure used for observations of Saturn's rings taken with the International Planetary Patrol Network in 1977. Corrections for atmospheric smearing are determined using an assumed ring model and performed by a two-dimensional Wiener filter developed at JPL's Image Processing Laboratory. These smearing corrections are shown to be consistent with the radial profile of the rings, not just on the major axis of the ring system, but over a range of azimuthal angle.

Lumme, K.↗

Design and development of a fast ion mass spectrometer

Two Fast Ion Mass Spectrometers (FIMS A and FIMS B) were developed. The design, development, construction, calibration, integration, and flight of these instruments, along with early results from the data analysis efforts are summarized. A medium energy ion mass spectrometer that covers mass velocity space with significantly higher time resolution, improved mass resolution, (particularly for heavier ions), and wider energy range than existing instruments had achieved was completed. The initial design consisted of a dual channel cylindrical electrostatic analyzer followed by a dual channel cylindrical velocity filter. The gain versus count rate characteristics of the high current channel electron multipliers (CEM's), which were chosen for ion detection, revealed a systematic behavior that can be used as a criterion for selection of CEM's for long counting lifetimes.

Burch, J. L.↗

Solar maximum: Solar array degradation

The 5-year in-orbit power degradation of the silicon solar array aboard the Solar Maximum Satellite was evaluated. This was the first spacecraft to use Teflon R FEP as a coverglass adhesive, thus avoiding the necessity of an ultraviolet filter. The peak power tracking mode of the power regulator unit was employed to ensure consistent maximum power comparisons. Telemetry was normalized to account for the effects of illumination intensity, charged particle irradiation dosage, and solar array temperature. Reference conditions of 1.0 solar constant at air mass zero and 301 K (28 C) were used as a basis for normalization. Beginning-of-life array power was 2230 watts. Currently, the array output is 1830 watts. This corresponds to a 16 percent loss in array performance over 5 years. Comparison of Solar Maximum Telemetry and predicted power levels indicate that array output is 2 percent less than predictions based on an annual 1.0 MeV equivalent election fluence of 2.34 x ten to the 13th power square centimeters space environment.

Miller, T.↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Onboard Calibration System

The AVIRIS instrument uses an onboard calibration system to provide auxiliary calibration data. The system consists of tungsten halogen cycle lamp imaged onto a fiber bundle through an eight position filter wheel. The fiber bundle illuminates the back side of the foreoptics shutter during a pre-run and post-run calibration sequence. The filter wheel contains 2 neutral density filters, 5 spectral filters and blocked position.

spectrometer↗

Simulating Study of Premixed Charge Compression Ignition on Light-Duty Diesel Fuel Economy and Emissions Control

We utilize the Powertrain Systems Analysis Toolkit (PSAT) combined with transient engine and aftertreatment component models to simulate the impact of premixed charge compression ignition (PCCI) on the fuel economy and emissions of light-duty (LD) diesel-powered conventional and hybrid electric vehicles (HEVs). Our simulated aftertreatment train consists of a diesel oxidation catalyst (DOC), lean NOx trap (LNT), and catalyzed diesel particulate filter (DPF). The results indicate that utilizing PCCI combustion significantly reduces fuel consumption and tailpipe emissions for the conventional diesel-powered vehicle with NOx and particulate emissions controls. These benefits result from a favorable engine speed-load distribution over the cycle combined with a corresponding reduction in the need to regenerate the LNT and DPF. However, the current PCCI technology appears to offer less potential benefit for diesel HEVs equipped with similar emissions controls. This is because PCCI can only be activated over a relatively small part of the drive cycle. Thus we conclude that future utilization of PCCI in diesel HEVs will require significant extension of the available speed-load range for PCCI and revision of current HEV engine management strategies before significant benefits can be realized.

33 ADVANCED PROPULSION SYSTEMS↗

Opdefender Network Monitoring And Control System

OpDefender is a new system designed to enhance the cyber security of control system networks. It accomplishes this by inspecting each network packet using a novel, patent-pending method that extends software defined networking into the application/ICS protocol layer. OpDefender consists of two key components: 1. Smart, “ICS-aware” network switches that analyze and filter network traffic in real time. 2. A network management human machine interface (HMI) that allows an operator to monitor and control network traffic in real time. The “ICS-aware” switches can serve as a drop-in replacement for typical network switches, or they can be used in conjunction with existing network switches. OpDefender is configured and controlled in real time via a custom-built, web-based HMI designed with the operator in mind.

Johnson, BriamE.↗

Graphene oxide and adsorption of chloroform: A density functional study

Chlorinated hydrocarbon compounds are of environmental concerns, since they are toxic to humans and other mammals, and are widespread, and exposure is hard to avoid. Understanding and improving methods to reduce the amount of the substances are important. We present an atomic-scale calculational study of the adsorption of chlorine-based substance chloroform (CHCl{sub 3}) on graphene oxide, as a step in estimating the capacity of graphene oxide for filtering out such substances, e.g., from drinking water. The calculations are based on density functional theory, and the recently developed consistent-exchange functional for the van der Waals density-functional method is employed. We obtain values of the chloroform adsorption energy varying from roughly 0.2 to 0.4 eV per molecule. This is comparable to previously found results for chloroform adsorbed directly on clean graphene, using similar calculations. In a wet environment, like filters for drinking water, the graphene will not stay clean and will likely oxidize, and thus adsorption onto graphene oxide, rather than clean graphene, is a more relevant process to study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-631: Commissioning and Comprehensive Evaluation of the ArcCHECK Cylindrical Diode Array for VMAT QA

Purpose: Commissioning and comprehensive evaluation of ArcCHECK phantom for dosimetry of VMAT QA, using 6MV photon beam with and without the flattening filter. Methods: ArcCHECK was evaluated for response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle and couch insertion. Scatter dose characterization, consistency and symmetry of response, dosimetric accuracy of fixed aperture arcs and clinical VMAT plans were investigated. Measurements were done using TrueBeam™ STx accelerator (Console version 1.6) with a 6 MV beam with and without flattening filter. Reference dose-grids were calculated using Eclipse TPS Analytical Anisotropic Algorithm (AAA version 10.0.39). Planned doses were calculated using symmetric 2mm 3D dose grids with 4 degree angular resolution defaulted to each control point. Gamma evaluations were performed in absolute dose mode, with default normalization to maximum dose in the curved plane and a low dose threshold of 10% to restrict the analysis to clinically relevant areas. Global and local gamma indices at 3mm/3% and 2mm/2% level were computed using SNC software (version 6.0). Results: Results of gamma analysis demonstrated an overall agreement between ArcCHECK measured and TPS calculated reference doses. Field size dependency was within 0.5% of the reference. Dose-rate based dependency was well within 1% of the TPS reference and the angular dependency was ±3% of the reference, as tested for BEV angles. At the level of 3%/3mm, narrow and wide open arcs as well as clinical VMAT cases demonstrated high level of dosimetry accuracy in global gamma passing rates for both 6X and 6F beams. At the level of 2%/2mm two VMAT cases involving the narrow heavily modulated arcs demonstrated lower passing rates. Conclusion: ArcCHECK phantom with latest software and hardware upgrades is suitable for VMAT QA. For higher sensitivity of 2%/2mm gamma analysis, we intend to use it as one of the VMAT QA evaluation metrics.

07 ISOTOPE AND RADIATION SOURCES↗

Nearly steady flows in GONG prototype data

Doppler velocity images obtained with the GONG prototype instrument were analyzed to measure the nearly steady photospheric flows. The data consists of 88 images each of velocity, intensity, and modulation obtained at 20:00 UT on 88 days from July 1992 to February 1994. Each velocity image was temporally filtered to remove the p-mode oscillations, masked to exclude active regions, and then analyzed using spherical harmonics and orthogonal functions as described by Hathaway (1992). The spectral coefficients show very consistent results for the entire time interval with some evidence of year-to-year variations. The rotation profile agrees well with previous results and exhibits a north-south asymmetry that reverses sign during the 20 month interval. The residual rotation velocities exhibit structures with amplitudes of approximately 5 m/s that may be related to torsional oscillations. The meridional circulation is directed from the equator toward the poles with a peak velocity in the photosphere of approximately 50 m/s. The higher order components are very weak but indicate a divergent flow from the mid-latitudes (opposite that found for the June 1989 data). The convective limb shift is well fit by a 3rd order polynomial. The convection spectrum has a prominent peak at spherical harmonic degrees of l approximately 150 with very little signal in the low degree modes. Analysis of this signal shows that there is no evidence for giant cell convection at the level of approximately 10 m/s for all modes up to l = 32.

Hathaway, David H.↗

Deterministic Mean-Field Ensemble Kalman Filtering

The proof of convergence of the standard ensemble Kalman filter (EnKF) from Le Gland, Monbet, and Tran [Large sample asymptotics for the ensemble Kalman filter, in The Oxford Handbook of Nonlinear Filtering, Oxford University Press, Oxford, UK, 2011, pp. 598--631] is extended to non-Gaussian state-space models. In this paper, a density-based deterministic approximation of the mean-field limit EnKF (DMFEnKF) is proposed, consisting of a PDE solver and a quadrature rule. Given a certain minimal order of convergence κ between the two, this extends to the deterministic filter approximation, which is therefore asymptotically superior to standard EnKF for dimension d < 2κ. The fidelity of approximation of the true distribution is also established using an extension of the total variation metric to random measures. Lastly, this is limited by a Gaussian bias term arising from nonlinearity/non-Gaussianity of the model, which arises in both deterministic and standard EnKF. Numerical results support and extend the theory.

97 MATHEMATICS AND COMPUTING↗

Investigating the Present Day Cosmic Dust Flux at the Earth's Surface: Initial Results from the Kwajalein Micrometeorite Collection

Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5μm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in origin (volcanic). Those of groups 2 and 3, however, typically exhibit quenched surface textures consistent with cosmic spherules. Initial results suggest there is significant variation in the abundance of these groups from filter to filter. Work is ongoing to fully characterize these spherules and to constrain their flux with time.

Wozniakiewicz, P. J.↗

An innovations approach to decoupling of multibody dynamics and control

The problem of hinged multibody dynamics is solved using an extension of the innovations approach of linear filtering and prediction theory to the problem of mechanical system modeling and control. This approach has been used quite effectively to diagonalize the equations for filtering and prediction for linear state space systems. It has similar advantages in the study of dynamics and control of multibody systems. The innovations approach advanced here consists of expressing the equations of motion in terms of two closely related processes: (1) the innovations process e, a sequence of moments, obtained from the applied moments T by means of a spatially recursive Kalman filter that goes from the tip of the manipulator to its base; (2) a residual process, a sequence of velocities, obtained from the joint-angle velocities by means of an outward smoothing operations. The innovations e and the applied moments T are related by means of the relationships e = (I - L)T and T = (I + K)e. The operation (I - L) is a causal lower triangular matrix which is generated by a spatially recursive Kalman filter and the corresponding discrete-step Riccati equation. Hence, the innovations and the applied moments can be obtained from each other by means of a causal operation which is itself casually invertible.

Rodriguez, G.↗

Understanding reconstructed Dante spectra using high resolution spectroscopy

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast response, optical radiance measurements of low intensity impurity emission in WEST plasmas with staggered wavelength filters

Fast response acquisition of atomic line emission through the use of a filterscope has been implemented on the WEST tokamak at multiple poloidal locations. Filterscopes consist of a fiber-optic-based transmission from the tokamak to specifically engineered optical bandpasses and photomultiplier tubes (PMT) that collect the emission intensity to measure a radiance, L [W/cm2/str], over the specified bandpass. This diagnostic records plasma-wall interaction (PWI) properties (e.g. impurity emission and recycling of main fuel ions) up to a max acquisition rate of 100 kHz. These PMT radiometric measurements are calibrated into a line-normalized radiance, LN [photons/sec/cm2/str], similar to traditional spectrometers, which can later be converted to a particle flux. Low intensity emission peaks are difficult to quantify due to often comparable continuum levels, thus a secondary filter shifted to a judiciously-selected, line-free region (~1 nm away) allows for background subtraction. The system currently installed on WEST targets tungsten (W) gross sputtering specifically by monitoring, with a filter pair, the spectral region near the neutral W line emission (W I 400.9 nm). The line and background filters of the pair are centered at 400.6 nm and 403.1 nm, respectively. Through a set beam splitters on each sight line, the filter pair are measuring from the same location. The two L signals near W I are then subtracted from each other yielding only the W I LN. W I LN data from a recent WEST experimental campaign is presented and compared with plasma parameters and traditional spectrometer measurements of W I line emission to demonstrate the capabilities of this staggered-filter filterscope method. Specifically, the choice of WEST-specific bandpass curves for the W I LN will be illustrated based on this latter comparison.

Neff, Anton↗