Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Mapping the effects of physical and chemical reduction parameters on local atomic distributions within bimetallic nanoparticles

Bimetallic nanoparticles prove advantageous over their monometallic counterparts due to the tunable, hybrid properties that result from combining different atomic species in a controlled way. The favorable optical and catalytic properties resulting from AgAu nanoparticle formation have been widely attributed to the existence of Ag–Au bonds, the maximization of which assumes the formation of a homogeneous alloy. Despite the importance of atomic scale structure in these systems, synthetic studies are typically not paired with structural characterization at the atomic scale. Herein, a comprehensive synthetic exploration of physical and chemical reduction parameters of resulting nanoparticle products is complemented with thorough X-ray characterization to probe how these parameters affect atomic scale alloy distributions within AgAu nanoparticles. Presented evidence shows Ag is substantially underincorporated into nanoparticle constructs compared with solution Ag : Au ratios regardless of precursor :reductant ratio or volume of reductant added. Both Ag and Au exhibit significant local clustering, with Ag distributed preferentially towards the nanoparticle surface. Most significantly, the results of this investigation suggest that reduction parameters alone can affect the local alloy distributions and homogeneity within bimetallic nanoparticles, even when the ratio of metallic precursors remains constant. Overall, this investigation presents the ability to control alloy distributions using kinetics and provides new considerations for optimizing synthetic methods to produce functional bimetallic nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Demonstration of a Novel Phase-Space Painting Method in a Coupled Lattice to Mitigate Space Charge in High-Intensity Hadron Beams

Multiturn charge-exchange injection is the primary method of creating high-intensity hadron beams in circular accelerators, and phase space painting during injection enables tailoring of the accumulated phase space distribution. A technique we call eigenpainting allows injection of particles into a single mode of a coupled ring, providing full four-dimensional control of the phase space distribution. Under ideal conditions, uniform eigenpainting generates a linear-force equilibrium distribution in the transverse plane, with zero volume in four-dimensional transverse phase space, even including space charge. Here, we have implemented eigenpainting for the first time in the spallation neutron source accumulator ring. Injecting 8.8 μ⁢C of an 800 MeV beam, we obtain a final ratio of intrinsic transverse emittances of ≈2.4. We analyze the effect of space charge on the final distribution through comparison of the reconstructed phase space to particle-in-cell simulations.

Evans, Nicholas J. [Oak Ridge National Laboratory ↗

Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms

Purpose: The authors develop a practical, iterative algorithm for image-reconstruction in undersampled tomographic systems, such as digital breast tomosynthesis (DBT). Methods: The algorithm controls image regularity by minimizing the image total p variation (TpV), a function that reduces to the total variation when p=1.0 or the image roughness when p=2.0. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets. The fact that the tomographic system is undersampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) Reduction in the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in undersampled tomography. Results: The proposed image-reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses. Conclusions: Results indicate that there may be a substantial advantage in using the present image-reconstruction algorithm for microcalcification imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-43: A Methodology for Quality Control of IMPT Treatment Plan Based On VMAT Plan

Purpose: IMPT plan design is highly dependent on planner’s experiences. VMAT plan design is relatively mature and can even be automated. The quality of IMPT plan designed by in-experienced planner could be inferior to that of VMAT plan designed by experienced planner or automatic planning software. Here we introduce a method for designing IMPT plan based on VMAT plan to ensure the IMPT plan be superior to IMRT/VMAT plan for majority clinical scenario. Methods: To design a new IMPT plan, a VMAT plan is first generated either by experienced planner or by in-house developed automatic planning system. An in-house developed tool is used to generate the dose volume constrains for the IMPT plan as plan template to Eclipse TPS. The beam angles for IMPT plan are selected based on the preferred angles in the VMAT plan. IMPT plan is designed by importing the plan objectives generated from VMAT plan. Majority thoracic IMPT plans are designed using this plan approach in our center. In this work, a thoracic IMPT plan under RTOG 1308 protocol is selected to demonstrate the effectiveness and efficiency of this approach. The dosimetric indices of IMPT are compared with VMAT plan. Results: The PTV D95, lung V20, MLD, mean heart dose, esophagus D1, cord D1 are 70Gy, 31%, 17.8Gy, 25.5Gy, 73Gy, 45Gy for IMPT plan and 65.3Gy, 34%, 21.6Gy, 35Gy, 74Gy, 48Gy for VMAT plan. For majority cases, the high dose region of the normal tissue which is in proximity of PTV is comparable between IMPT and VMAT plan. The low dose region of the IMPT plan is significantly better than VMAT plan. Conclusion: Using the knowledge gained in VMAT plan design can help efficiently and effectively design high quality IMPT plan. The quality of IMPT plan can be controlled to ensure the superiority of IMPT plan compared to VMAT/IMRT plan.

60 APPLIED LIFE SCIENCES↗

Synthesis, growth mechanisms, and applications of palladium-based nanowires and other one-dimensional nanostructures

Palladium-based nanostructures have attracted the attention of researchers due to their useful catalytic properties and unique ability to form hydrides, which finds application in hydrogen storage and hydrogen detection. Palladium-based nanowires have some inherent advantages over other Pd nanomaterials, combining high surface-to-volume ratio with good thermal and electron transport properties, and exposing high-index crystal facets that can have enhanced catalytic activity. Over the past two decades, both synthesis methods and applications of 1D palladium nanostructures have advanced greatly. In this review, we start by discussing different types of 1D palladium nanostructures before moving on to the different synthesis approaches that can produce them. Next, we discuss factors including kinetic vs. thermodynamic control of growth, oxidative etching, and surface passivation that affect palladium nanowire synthesis. We also review efforts to gain insight into growth mechanisms using different characterization tools. We discuss the effects of concentration of capping agents, reducing agents, metal halides, pH, and sacrificial oxidation on the growth of Pd-based nanowires in solution, from shape control, to yield, to aspect ratio. Various applications of palladium and palladium alloy nanowires are then discussed, including electrocatalysis, hydrogen storage, and sensing of hydrogen and other chemicals. We end with a summary and some perspectives on future research directions for this category of nanomaterials.

36 MATERIALS SCIENCE↗

Gas-discharge plasma sources for nonlocal plasma technology

Nonlocal plasma technology is based on the effect of self-trapping of fast electrons in the plasma volume [V. I. Demidov, C. A. DeJoseph, Jr., and A. A. Kudryavtsev, Phys. Rev. Lett. 95, 215002 (2006)]. This effect can be achieved by changing the ratio of fast electron flux to ion flux incident on the plasma boundaries. This in turn leads to a significant change in plasma properties and therefore can be useful for technological applications. A gas-discharge device which demonstrates control of the plasma properties by this method is described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small-angle light scattering symmetry breaking in polymer-dispersed liquid crystal films with inhomogeneous electrically controlled interface anchoring

We have described the method of analyzing and reporting on the results of calculation of the small-angle structure of radiation scattered by a polymer-dispersed liquid crystal film with electrically controlled interfacial anchoring. The method is based on the interference approximation of the wave scattering theory and the hard disk model. Scattering from an individual liquid crystal droplet has been described using the anomalous diffraction approximation extended to the case of droplets with uniform and nonuniform interface anchoring at the droplet–polymer boundary. The director field structure in an individual droplet is determined from the solution of the problem of minimizing the volume density of the free energy. The electrooptical effect of symmetry breaking in the angular distribution of scattered radiation has been analyzed. This effect means that the intensities of radiation scattered within angles +θ{sub s} and–θ{sub s} relative to the direction of illumination in the scattering plane can be different. The effect is of the interference origin and is associated with asymmetry of the phase shift of the wavefront of an incident wave from individual parts of the droplet, which appears due to asymmetry of the director field structure in the droplet, caused by nonuniform anchoring of liquid crystal molecules with the polymer on its surface. This effect is analyzed in the case of normal illumination of the film depending on the interfacial anchoring at the liquid crystal–polymer interface, the orientation of the optical axes of droplets, their concentration, sizes, anisometry, and polydispersity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A self-consistent boundary element, parametric dislocation dynamics formulation of plastic flow in finite volumes

We present a self-consistent formulation of 3-D parametric dislocation dynamics (PDD) with the boundary element method (BEM) to describe dislocation motion, and hence microscopic plastic flow in finite volumes. We develop quantitative measures of the accuracy and convergence of the method by considering a comparison with known analytical solutions. It is shown that the method displays absolute convergence with increasing the number of quadrature points on the dislocation loop and the surface mesh density. The error in the image force on a screw dislocation approaching a free surface is shown to increase as the dislocation approaches the surface, but is nevertheless controllable. For example, at a distance of one lattice parameter from the surface, the relative error is less than 5% for a surface mesh with an element size of 1000 x 2000 (in units of lattice parameter), and 64 quadrature points. The Eshelby twist angle in a finite-length cylinder containing a coaxial screw dislocation is also used to benchmark the method. Finally, large scale 3-D simulation results of single slip behavior in cylindrical microcrystals are presented. Plastic flow characteristics and the stress-strain behavior of cylindrical microcrystals under compression are shown to be in agreement with experimental observations. It is shown that the mean length of dislocations trapped at the surface is the dominant factor in determining the size effects on hardening of single crystals. The influence of surface image fields on the flow stress is finally explored. It is shown that the flow stress is reduced by as much as 20% for small single crystals of size less than 0.15 {micro}m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HAP1 gene expression is associated with radiosensitivity in breast cancer cells

Highlights: • Overexpression of HAP1 gene promotes apoptosis in MCF-7 cells after irradiation. • HAP1 reduces tumor volume in nude mice xenograft models after irradiation. • HAP1 increases radiosensitivity of breast cancer cells in vitro and vivo. - Abstract: Objectives: The purpose of this study was to investigate the relationship between huntingtin-associated protein1 (HAP1) gene and radiation therapy of breast cancer cells. Methods: HAP1 gene was transfected into breast cancer MCF-7 cells, which was confirmed by quantitative reverse transcription-polymerase chain reaction analysis (qRT-PCR) and Western blot in vitro. The changes of cell radiosensitivity were assessed by colony formation assay. Apoptosis were examined by flow cytometry. The expressions of two radiation-induced genes were evaluated by Western blot. Tumor growth was investigated in nude mice xenograft models in vivo. Results: Our data showed that HAP1 gene expression was significantly increased in HAP1-transfected MCF-7 cells in comparison with the parental cells or negative control cells. The survival rate in MCF-7/HAP1 cells was significantly decreased after irradiation (0, 2, 4, 6, 8 Gy), compared to cells in MCF-7 and MCF-7/Pb groups in vitro. HAP1 gene increased apoptosis in MCF-7 cells after irradiation. Additionally, the tumor volume and weight in MCF-7/HAP1 + RT group were observably lower than in MCF-7/HAP1 group and MCF-7/Pb + RT group. Conclusion: The present study indicated that HAP1 gene expression was related to the radiosensitivity of breast cancer cells and may play an important role in the regulation of cellular radiosensitivity.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Simulation in the Optimization of a Free-Air Ionization Chamber for Dosimetric Control in Medical Digital Radiography

During the earliest tests of a free-air ionization chamber a poor response to the X-rays emitted by several sources was observed. Then, the Monte Carlo simulation of X-rays transport in matter was employed in order to evaluate chamber behavior as X-rays detector. The photons energy deposition dependence with depth and its integral value in all active volume were calculated. The obtained results reveal that the designed device geometry is feasible to be optimized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrating helicoid channels for passive control of fiber alignment in direct-write 3D printing

3D printing of fiber-reinforced composites has been receiving increasing attention as an efficient additive approach enabling lightweight, functional, and high-performance components required for industrial applications. The properties of fiber composites significantly depend on internal microstructures, including fiber orientation, distribution, and degree of alignment. Although multiple strategies have been introduced for controlling the fiber composites microstructures, these strategies are mostly active approaches relying on additional control of mechatronics parts, external forces, or intentionally introduced unstable flows inside narrow nozzles. These methods suffer from higher risk of nozzle clogging and requiring extra parts in 3D printing. Here, we introduce helicoid channels into extrusion system as a passive approach to control the fiber alignment without any additional moving parts in direct-write 3D printing. The helicoid channels automatically guide the composite inks and align fibers before flowing into narrow nozzle space, avoiding clogging and improving printability. The analyses indicate that both helicoid surface to volume ratio and helix angle affect the pre-alignment of fibers, leading to tunable mechanical properties of printed fiber-reinforced composites with increased stiffness and strength up to 77.6% and 47.8%, respectively.

36 MATERIALS SCIENCE↗

Stochastic Predictions of Cell Kill During Stereotactic Ablative Radiation Therapy: Do Hypoxia and Reoxygenation Really Matter?

Purpose: To simulate stereotactic ablative radiation therapy on hypoxic and well-oxygenated in silico tumors, incorporating probabilistic parameter distributions and linear-quadratic versus linear-quadratic-cubic methodology and the evaluation of optimal fractionation schemes using biological effective dose (BED{sub α/β=10} {sub or} {sub 3}) comparisons. Methods and Materials: A temporal tumor growth and radiation therapy algorithm simulated high-dose external beam radiation therapy using stochastic methods. Realistic biological proliferative cellular hierarchy and pO{sub 2} histograms were incorporated into the 10{sup 8}-cell tumor model, with randomized radiation therapy applied during continual cell proliferation and volume-based gradual tumor reoxygenation. Dose fractions ranged from 6-35 Gy, with predictive outcomes presented in terms of the total doses (converted to BED) required to eliminate all cells that could potentially regenerate the tumor. Results: Well-oxygenated tumor control BED{sub 10} outcomes were not significantly different for high-dose versus conventional radiation therapy (BED{sub 10}: 79-84 Gy; Equivalent Dose in 2 Gy fractions with α/β of 10: 66-70 Gy); however, total treatment times decreased from 7 down to 1-3 weeks. For hypoxic tumors, an additional 28 Gy (51 Gy BED{sub 10}) was required, with BED{sub 10} increasing with dose per fraction due to wasted dose in the final fraction. Fractions of 9 Gy compromised well for total treatment time and BED, with BED{sub 10}:BED{sub 3} of 84:176 Gy for oxic and 132:278 Gy for non-reoxygenating hypoxic tumors. Initial doses of 12 Gy followed by 6 Gy further increased the therapeutic ratio. When delivering ≥9 Gy per fraction, applying reoxygenation and/or linear-quadratic-cubic cell survival both affected tumor control doses by a significant 1-2 fractions. Conclusions: The complex temporal dynamics of tumor oxygenation combined with probabilistic cell kinetics in the modeling of radiation therapy requires sophisticated stochastic modeling to predict tumor cell kill. For stereotactic ablative radiation therapy, high doses in the first week followed by doses that are more moderate may be beneficial because a high percentage of hypoxic cells could be eradicated early while keeping the required BED{sub 10} relatively low and BED{sub 3} toxicity to tolerable levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kinetic modeling of ignition in miniature shock tube

The ignition delay times of toluene, n-heptane/iso-octane primary reference fuel blends, and toluene/n-heptane/iso-octane toluene primary reference fuel blends were studied in the miniature high repetition rate shock tube (HRRST). In the HRRST, the temperature and pressure change during the test time, complicating interpretation of ignition delay times. Two methods of chemical kinetic modeling were employed in order to account for the changing thermodynamic states in the HRRST. One was based on direct modeling using the pressure profile and the kinetic mechanism, and the other was based on a Livengood-Wu type approach using modeled constant volume ignition delay times. Two different kinetic mechanisms were used in modeling the data. Both methods showed agreement with experimental data over a range of temperatures, pressures, and blends. While overall agreement was fair, agreement was poorer for one of the mechanisms for the primary reference fuel blends. An evaluation of the ignition delay iso-contours from these mechanisms for representative HRRST experiment thermodynamic trajectories revealed that the HRRST measured IDTs are controlled by the high temperature chemistry and are more sensitive to temperature. Furthermore, the different performance of mechanisms is therefore attributed to their different high temperature reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-C-204-01: A Dosimetric Investigation Into the Effects of Yttrium-90 Radioembolization On the GI Tract: In-Vivo and Histological Analysis in An Animal Model

Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall. A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared to external-beam radiation therapy in gastrointestinal tissue. This project was supported by SIRTex Medical Ltd.

60 APPLIED LIFE SCIENCES↗

Detection of small drizzle droplets in a large cloud chamber using ultrahigh-resolution radar

Abstract. A large convection–cloud chamber has the potential to produce drizzle-sized droplets, thus offering a new opportunity to investigate aerosol–cloud–drizzle interactions at a fundamental level under controlled environmental conditions. One key measurement requirement is the development of methods to detect the low-concentration drizzle drops in such a large cloud chamber. In particular, remote sensing methods may overcome some limitations of in situ methods. Here, the potential of an ultrahigh-resolution radar to detect the radar return signal of a small drizzle droplet against the cloud droplet background signal is investigated. It is found that using a small sampling volume is critical to drizzle detection in a cloud chamber to allow a drizzle drop in the radar sampling volume to dominate over the background cloud droplet signal. For instance, a radar volume of 1 cubic centimeter (cm3) would enable the detection of drizzle embryos with diameter larger than 40 µm. However, the probability of drizzle sampling also decreases as the sample volume reduces, leading to a longer observation time. Thus, the selection of radar volume should consider both the signal power and the drizzle occurrence probability. Finally, observations from the Pi Convection–Cloud Chamber are used to demonstrate the single-drizzle-particle detection concept using small radar volume. The results presented in this study also suggest new applications of ultrahigh-resolution cloud radar for atmospheric sensing.

54 ENVIRONMENTAL SCIENCES↗

Conditioning of Pu-containing radioactive waste generated in the Hot-lab: where are we now - 15400

To achieve an optimal strategy for interim storage and final disposal, solid radioactive waste has to be sorted and treated. This strategy is based on the requirement to reduce the volume of waste designated for long term disposal, mainly for economical and safety reasons. In addition, the radiological limitations for shipping of the waste packages to a disposal site have to be taken into account as well as the improved regulatory requirements for material under IAEA control. In case of the operational Pu-contaminated and -containing waste from the PSI-Hot laboratory in Switzerland, the existing and over years practiced conditioning method needed improvement. The existing authorized specifications of the conditioning process had to be revised for an optimization of the interim-storage and the deep geological disposal. This was done by the PSI Section for Dismantling and Waste Management. The improvement focused on technical aspects as well as improvement of the documentation for the certification by final depositor (Nagra) and the safety authority (ENSI). This work started in 2008. In 2012 ENSI issued an authorization to realize the first conditioning according the new specification, formally as a certification test ('Type Test') prior to final approval by the ENSI. But, although a licensed method by the competent authority is available, modifications could be necessary and new tasks come up. In 2013 the PSI has produced 13 waste-packages as a Type Test. To obtain the legal authorization ('Type Approval'), some open issues ought to be answered. Waste is continuously generated and so the question arises: When will the next conditioning be done and applying which method? (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-H-19A-04: Multichannel CW Ultrasonic Thermometry for Imaging Therapeutic Dose Fields in Water

Purpose: To develop a scalable, multichannel ultrasonic thermometry system suitable for imaging clinical-beam dose distributions in a water phantom. Method: A small, glass-walled rectangular water phantom (15 cm × 20 cm × 30 cm) was filled with distilled water, and two ultrasonic transducers were placed on the outside, against opposing walls, approximately 5 cm below the water line, and were aligned to optimize transmission/reception of ultrasound between them. Two synchronized lock-in amplifiers were connected to the transducers to enable full-duplex operation of two separate ultrasonic frequency channels configured to transmit simultaneously through the same volume of water and thereby provide independent measurements of the temperature-dependent ultrasonic phase lag. Controlled heating of the water via immersed power resistors provided a means to study dependence of measured phase lag on temperature change for both channels; cross-correlation of the phase outputs enabled much smaller temperature fluctuations in the phantom to be used to ascertain the noise floor and achievable temperature resolution. Results: Temperature measurements from both channels, converted from phase measurements via polynomials available in the literature, exhibited the expected linear dependence of ultrasonic phase on temperature change (measured via calibrated thermistor probe). Cross-correlation analysis of phase fluctuations yielded rms noise estimates of approximately 1-2 microKelvin, comparable to that observed in standard water calorimeters. Conclusion: Phase-sensitive detection of cw ultrasound has been shown to provide temperature sensitivity needed for calorimetry of external treatment beams, and the present simple demonstration establishes that multiple channels may be run simultaneously without phase disturbances that currently affect time-of-flight techniques utilizing phase-detection. Immediate plans include doubling the number of sensors, to enable a simple tomographic reconstruction, and to test the system in Clinac x-rays and electron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of linear accelerator performance standards using an outcome oriented approach

Radiation therapy, along with other branches of medicine, is moving towards a firmer basis in evidence to optimally utilize resources. As new treatment technology and strategies place greater demands on quality assurance resources, the need to objectively evaluate equipment and process performance standards from the perspective of predicted clinical impact becomes more urgent. This study evaluates the appropriateness of recommended quality control tolerance and action levels for linear accelerators based on the calculated dosimetric impact of suboptimal equipment performance. A method is described to quantify the dosimetric changes, as reflected by the changes in the outcome surrogate, equivalent uniform dose (EUD), of machine performance deviations from the optimal, specifically in the range of tolerance and action levels promulgated by the Canadian Association of Provincial Cancer Agencies (CAPCA). Linear accelerator performance deviations were simulated for the treatment of prostate, breast, lung, and brain using 3D conformal techniques, and the impact evaluated in terms of the changes in the EUD of the target volumes and two principal organs at risk (OARs) per site. The eight key performance characteristics examined are: Output constancy, beam flatness, gantry angle, collimator angle, field size indicator, laser alignment (three directions) and, by inference, the optical distance indicator. Currently accepted CAPCA tolerance levels for these eight performance characteristics are shown to maintain average EUD deviations to within 2% for the targets and 2 Gy for the OARs. However, within the 2% or 2 Gy range, the recommended tolerance levels are found to have markedly different effects on the EUDs of the structures of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗