Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Phenomenological Constitutive Modeling of High-Temperature Flow Behavior Incorporating Individual and Coupled Effects of Processing Parameters in Super-austenitic Stainless Steel

A novel constitutive model has been developed for predicting flow responses of super-austenitic stainless steel over a wide range of strains (0.05-0.6), temperatures (1173-1423 K) and strain rates (0.001-1 s{sup −1}). Further, the predictability of this new model has been compared with the existing Johnson–Cook (JC) and modified Zerilli–Armstrong (M-ZA) model. The JC model is not befitted for flow prediction as it is found to be exhibiting very high (~ 36%) average absolute error (δ) and low (~ 0.92) correlation coefficient (R). On the contrary, the M-ZA model has demonstrated relatively lower δ (~ 13%) and higher R (~ 0.96) for flow prediction. The incorporation of couplings of processing parameters in M-ZA model has led to exhibit better prediction than JC model. However, the flow analyses of the studied alloy have revealed the additional synergistic influences of strain and strain rate as well as strain, temperature, and strain rate apart from those considered in M-ZA model. Hence, the new phenomenological model has been formulated incorporating all the individual and synergistic effects of processing parameters and a ‘strain-shifting’ parameter. The proposed model predicted the flow behavior of the alloy with much better correlation and generalization than M-ZA model as substantiated by its lower δ (~ 7.9%) and higher R (~ 0.99) of prediction.

36 MATERIALS SCIENCE↗

Measuring the axial form factor of {sup 3}He using weak capture of polarized electrons

A low energy, high intensity polarized electron beam could enable the extraction of the A=3 weak axial form factors F{sub A} using the reaction →e+{sup 3}He→{sup 3}H+ν. These form factors have never been measured before. We discuss the feasibility of such an experiment using a small toroidal magnet and a radial low energy recoil detector to tag the recoil tritons. A moderately high intensity polarized electron beam (>500 μA) with beam energies between 50 - 150 MeV is necessary for the cross section measurement and to provides a free clean measurement of the background. Moreover, in addition to the cross section, by measuring the electron spin and recoil triton correlation coefficient it may be possible to search for second class currents and to extract the ratio of the axial to the vector form factor of the nucleon. Such novel electron scattering based measurements would have a completely different set of systematic uncertainties compared to polarized neutron beta decay, neutrino scattering and muon capture experiments which are typically used to extract the weak form-factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Urinary polycyclic aromatic hydrocarbon metabolites among 3-year-old children from Krakow, Poland

Highlights: • ETS, combustion of gas, coal or wood indoors were associated with OH-PAH levels. • The predominant metabolites in urine were OH-napthalenes and OH-fluorenes. • In biomonitoring of PAHs exposure, measuring only 1-OH-pyrene is insufficient. • Urinary OH-PAHs only modestly reflect high molecular weight PAHs exposures. Polycyclic aromatic hydrocarbons (PAHs) are widespread in the environment and can adversely affect human health. The aim of the present study is to describe the level of PAHs exposure in children living in Kraków, one of the most polluted cities in Poland, and to determine the relationship of urinary biomarkers with environmental PAHsexposure. Urinary monohydroxy metabolites (OH-PAHs) of 20 PAHs were assessed in 218 three-year old children, of which only 10 were present in nearly all the samples: monohydroxy metabolites of naphthalene, fluorene, phenantrene and pyrene. Of the metabolites analyzed, hydroxynaphthalenes were predominant and constituted almost 73% of total excreted OH-PAHs, while 1-OH-PYRene was the least abundant (2.3% of total OH-PAHs). All measured urinary OH-PAHs were statistically significantly correlated with each other (R = 0.165–0.880) but the highest correlation coefficients with other individual OH-PAHs and with total OH-PAHs were observed for 2-OH-FLUOR. Children exposed at home to environmental tobacco smoke (ETS) had higher concentrations of fluorene and pyrene urinary metabolites compared to those without ETS exposure; and those exposed to gas-based appliances used for cooking or heating water had higher levels of fluorene and phenanthrene metabolites than children not exposed. The use of coal, wood or oil for heating was associated with elevated levels of 1-OH-PYRene. Urinary PAHs metabolites only modestly reflect high molecular weight carcinogenic PAHs exposures such as those monitored in air in the present study. None of the measured PAHs metabolites was correlated with airborne PM{sub 2.5} and only two were slightly correlated with measured higher molecular mass airborne PAHs. The average concentrations of these specific metabolites in Polish children were much higher than observed in other pediatric populations living in developed countries. Our findings suggest that to capture various sources of PAHs, in addition to 1-OH-PYRene, biomonitoring of PAHs exposure should include 2-OH-NAP and 2-OH-FLUOR.

54 ENVIRONMENTAL SCIENCES↗

Direct phase selection of initial phases from single-wavelength anomalous dispersion (SAD) for the improvement of electron density and ab initio structure determination

A novel direct phase-selection method to select optimized phases from the ambiguous phases of a subset of reflections to replace the corresponding initial SAD phases has been developed. With the improved phases, the completeness of built residues of protein molecules is enhanced for efficient structure determination. Optimization of the initial phasing has been a decisive factor in the success of the subsequent electron-density modification, model building and structure determination of biological macromolecules using the single-wavelength anomalous dispersion (SAD) method. Two possible phase solutions (ϕ{sub 1} and ϕ{sub 2}) generated from two symmetric phase triangles in the Harker construction for the SAD method cause the well known phase ambiguity. A novel direct phase-selection method utilizing the θ{sub DS} list as a criterion to select optimized phases ϕ{sub am} from ϕ{sub 1} or ϕ{sub 2} of a subset of reflections with a high percentage of correct phases to replace the corresponding initial SAD phases ϕ{sub SAD} has been developed. Based on this work, reflections with an angle θ{sub DS} in the range 35–145° are selected for an optimized improvement, where θ{sub DS} is the angle between the initial phase ϕ{sub SAD} and a preliminary density-modification (DM) phase ϕ{sub DM}{sup NHL}. The results show that utilizing the additional direct phase-selection step prior to simple solvent flattening without phase combination using existing DM programs, such as RESOLVE or DM from CCP4, significantly improves the final phases in terms of increased correlation coefficients of electron-density maps and diminished mean phase errors. With the improved phases and density maps from the direct phase-selection method, the completeness of residues of protein molecules built with main chains and side chains is enhanced for efficient structure determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ensemble cure kinetics network (ECK-Net): A method to derive cure kinetics of thermosetting resin

This paper introduces an Ensemble Cure Kinetics Network (ECK-Net), a neural network (NN)–based framework for modeling the cure kinetics of thermosetting resins within a phenomenological context. ECK-Net replaces traditional analytic models, which require extensive chemical insight and multiple isothermal/non-isothermal experiments, with a data-driven surrogate that maps nonlinear relationships between temperature, degree of cure, and reaction rate from differential scanning calorimetry data. The proposed approach predicts input-dependent kinetic coefficients of a generalized nth-order reaction equation rather than reaction rates directly, enabling a single unified model to represent various epoxy systems without relying on iso-conversional analysis or predefined functional forms. To ensure robustness, multiple independently trained networks under different random initializations are blended through an ensemble strategy, effectively mitigating the stochastic variability inherent to neural networks. The framework is validated using experimental datasets from multiple resin systems, including aerospace-grade materials (Toray 3900-2, Cycom 5320-1, and Hexcel 8552) and a windmill-grade resin (RIMR 035c). The model accurately reproduces the temporal evolution of the degree of cure under manufacturers’ recommended cure cycles across all tested resins systems, yielding Pearson’s correlation coefficients of 0.992, 0.994, 0.993, 0.997, respectively. To demonstrate process-level applicability, the trained network was implemented within the Abaqus environment to simulate out-of-autoclave (OOA) curing process of the CFRP panel composed of Toray T830H-6K/3900-2D prepreg. The simulation results showed excellent agreement with experimental temperature response (maximum peak temperature, simulation: 189.6 °C, experiment: 188.5 °C) and the final degree of cure (simulation: 0.948, experiment: 0.960 ± 0.013), confirming ECK-Net’s capability as a reliable alternative to conventional cure kinetics modeling methods.

Composite curing↗

Analysis of Existing Data from a Distributed Acoustic Sensing Experiment at Garner Valley, California

In September 2013, an experiment using Distributed Acoustic Sensing (DAS) was conducted at Garner Valley, a test site of the University of California Santa Barbara (Lancelle et al., 2014). This submission includes noise cross-correlation functions (NCF) . Each file includes a NCF between two channels. The name of each channel denotes the distance in meters from starting point of the fiber-optic cable. The NCF is a time series data. The column 1 and 2 are time in seconds and dimensionless amplitude (cross correlation coefficient) respectively. Lancelle, C., N. Lord, H. Wang, D. Fratta, R. Nigbor, A. Chalari, R. Karaulanov, J. Baldwin, and E. Castongia (2014), Directivity and Sensitivity of Fiber-Optic Cable Measuring Ground Motion using a Distributed Acoustic Sensing Array (abstract # NS31C-3935), AGU Fall Meeting. https://agu.confex.com/agu/fm14/webprogram/Session1938.html The e-poster is available at: https://agu.confex.com/data/handout/agu/fm14/Paper_19828_handout_696_0.pdf

15 GEOTHERMAL ENERGY↗

Image encryption and watermarking combined dynamic chaotic hopping pattern with double random phase encoding DRPE

In modern civilization information, security is a crucial problem. Image encryption and watermarking can effectively protect information from unauthorized access. This paper introduces a new vigorous symmetric optical image encryption and watermarking technique. This technique depends on a novel dynamic delay chaotic hopping pattern (DDCHP) combined with double random phase encoding (DRPE). To get a robust watermark image, the plain image is first watermarked with a binary secret message using a new chaotic hopping pattern (CHP) and then encrypted using a DRPE system that is controlled by double random independent keys generated with double DDCHP. In this symmetric cryptosystem, three different chaotic maps are used to enlarge the key space of the proposed cryptosystem against brute-force attack and overcome the linearity and vulnerable of the classical DRPE. The system keys are hypersensitive and their initial parameters are selected carefully. Security scrutiny proves the efficiency of the suggested cryptosystem. Therefore, the obtained simulation results prove that the cryptosystem is robust enough against the known attacks, such as statistical attack (uniform histograms of different encrypted images, correlation coefficients between the plain and the encrypted image is as low as 5.46 × 10{sup −6}), differential attack (99.99% NPCR and 38.6% UACI), brute force attack (large enough key space), and entropy attack. Moreover, the robustness of the watermark (secret message) is proved due to the solidity of CHP. The proposed approach can be used in different implementations like secure military communications, e-finance, e-healthcare, authenticated multimedia broadcasting, etc.

97 MATHEMATICS AND COMPUTING↗

ON THE MAGNETIC AND ENERGY CHARACTERISTICS OF RECURRENT HOMOLOGOUS JETS FROM AN EMERGING FLUX

In this paper, we present the detailed analysis of recurrent homologous jets originating from an emerging negative magnetic flux at the edge of an active region. The observed jets show multithermal features. Their evolution shows high consistence with the characteristic parameters of the emerging flux, suggesting that with more free magnetic energy, the eruptions tend to be more violent, frequent, and blowout-like. The average temperature, average electron number density, and axial speed are found to be similar for different jets, indicating that they should have been formed by plasmas from similar origins. Statistical analysis of the jets and their footpoint region conditions reveals a strong positive relationship between the footpoint region total 131 Å intensity enhancement and jets’ length/width. Stronger linearly positive relationships also exist between the total intensity enhancement/thermal energy of the footpoint regions and jets’ mass/kinetic/thermal energy, with higher cross-correlation coefficients. All the above results together confirm the direct relationship between the magnetic reconnection and the jets and validate the important role of magnetic reconnection in transporting large amounts of free magnetic energy into jets. It is also suggested that there should be more free energy released during the magnetic reconnection of blowout than of standard jet events.

79 ASTRONOMY AND ASTROPHYSICS↗

Deriving the Intrahepatic Arteriovenous Shunt Rate from CT Images and Biochemical Data Instead of from Arterial Perfusion Scintigraphy in Hepatic Arterial Infusion Chemotherapy

The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual}; calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Serial crystallography with multi-stage merging of thousands of images

KAMO and BLEND provide particularly effective tools to automatically manage the merging of large numbers of data sets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending BLEND to support additional clustering options such as the use of more accurate cell distance metrics and the use of reflection-intensity correlation coefficients to infer `distances' among sets of reflections. This increases the sensitivity to differences in unit-cell parameters and allows clustering to assemble nearly complete data sets on the basis of intensity or amplitude differences. If the data sets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. When starting from incomplete data sets, one applies KAMO twice, first using unit-cell parameters. In this step, either the simple cell vector distance of the original BLEND or the more sensitive NCDist is used. This step tends to find clusters of sufficient size such that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between reflections with a common hkl to merge clusters in a way that is sensitive to structural differences that may not have perturbed the unit-cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into categories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent of one another, it should be possible to greatly improve the efficacy of data-clustering software by using a multi-stage partitioning strategy. Here, one possible approach to multi-stage data clustering is demonstrated. The strategy is to use unit-cell clustering until the merged data are sufficiently complete and then to use intensity-based clustering. Using this strategy, it is demonstrated that it is possible to accurately cluster data sets from crystals that have subtle differences.

36 MATERIALS SCIENCE↗

Thinking outside the box: effects of modes larger than the survey on matter power spectrum covariance

Accurate power spectrum (or correlation function) covariance matrices are a crucial requirement for cosmological parameter estimation from large scale structure surveys. In order to minimize reliance on computationally expensive mock catalogs, it is important to have a solid analytic understanding of the different components that make up a covariance matrix. Considering the matter power spectrum covariance matrix, it has recently been found that there is a potentially dominant effect on mildly non-linear scales due to power in modes of size equal to and larger than the survey volume. This beat coupling effect has been derived analytically in perturbation theory and while it has been tested with simulations, some questions remain unanswered. Moreover, there is an additional effect of these large modes, which has so far not been included in analytic studies, namely the effect on the estimated average density which enters the power spectrum estimate. In this article, we work out analytic, perturbation theory based expressions including both the beat coupling and this local average effect and we show that while, when isolated, beat coupling indeed causes large excess covariance in agreement with the literature, in a realistic scenario this is compensated almost entirely by the local average effect, leaving only ∼ 10% of the excess. We test our analytic expressions by comparison to a suite of large N-body simulations, using both full simulation boxes and subboxes thereof to study cases without beat coupling, with beat coupling and with both beat coupling and the local average effect. For the variances, we find excellent agreement with the analytic expressions for k < 0.2 hMpc{sup −1} at z = 0.5, while the correlation coefficients agree to beyond k = 0.4 hMpc{sup −1}. As expected, the range of agreement increases towards higher redshift and decreases slightly towards z = 0. We finish by including the large-mode effects in a full covariance matrix description for arbitrary survey geometry and confirming its validity using simulations. This may be useful as a stepping stone towards building an actual galaxy (or other tracer's) power spectrum covariance matrix.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of a Single Water Cerenkov Detector to Monitor Forbush Decreases

We describe a simple experimental setup to measure the rate of arrival of muons at the surface of the Earth by using a single water Cerenkov detector and home-made electronics. We find a strong anti-correlation between the muon rates averaged over one-hour periods and the atmospheric pressure, with a measured correlation coefficient of -0.67% per hPa. After applying this correction we achieve sufficient sensitivity to observe long term (hours) variations in the averaged muon rates which are greater than 2%. Forbush decreases as big as 4% have been observed with muon detectors located at similar magnetic rigidities compared to Morelia, therefore our experimental setup will detect Forbush decreases as soon as the Sun enters into a more active phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decision-making in structure solution using Bayesian estimates of map quality: the PHENIX AutoSol wizard

Ten measures of experimental electron-density-map quality are examined and the skewness of electron density is found to be the best indicator of actual map quality. A Bayesian approach to estimating map quality is developed and used in the PHENIX AutoSol wizard to make decisions during automated structure solution. Estimates of the quality of experimental maps are important in many stages of structure determination of macromolecules. Map quality is defined here as the correlation between a map and the corresponding map obtained using phases from the final refined model. Here, ten different measures of experimental map quality were examined using a set of 1359 maps calculated by re-analysis of 246 solved MAD, SAD and MIR data sets. A simple Bayesian approach to estimation of map quality from one or more measures is presented. It was found that a Bayesian estimator based on the skewness of the density values in an electron-density map is the most accurate of the ten individual Bayesian estimators of map quality examined, with a correlation between estimated and actual map quality of 0.90. A combination of the skewness of electron density with the local correlation of r.m.s. density gives a further improvement in estimating map quality, with an overall correlation coefficient of 0.92. The PHENIX AutoSol wizard carries out automated structure solution based on any combination of SAD, MAD, SIR or MIR data sets. The wizard is based on tools from the PHENIX package and uses the Bayesian estimates of map quality described here to choose the highest quality solutions after experimental phasing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comprehensive study of the influence of different environments on degradation processes in F8BT: Correlating optoelectronic properties with Raman measurements

There is a growing interest in conjugated polymers from both industrial and academic points of views. The reasons are their tunable optoelectronic properties, ease of production, and excellent mechanical properties. However, the ease with which their optoelectronic properties are tunable make devices based on them prone to fast degradation and therefore, short life time. The issue of degradation of organic based optoelectronic devices is the topic of many ongoing researches. However, much less attention is given to degradation processes of the individual components of the devices and their dependence on the environmental conditions. In this work, we report on the degradation of a film of a polyfluorene block copolymer F8BT that is used in a variety of optoelectronic devices under different environments: Sun exposure, heating, and UV exposure in inert and ambient conditions. Degradation was observed in most of the optoelectronic properties of the film. Topographic measurements did not show observable changes of the film morphology following degradation. However, Raman spectroscopy measurements show changes that indicate degradation in one of the building blocks of the copolymer that is associated with electron's conduction. The absolute value of the correlation coefficient between the decrease in the Raman signal and the decrease in the optoelectronic properties is larger than 0.95 under sun exposure it is larger than 0.8 under all other ambient exposures and smaller than 0.65 under inert conditions. These results support the assumption that Oxygen, not necessarily through photo-oxidation, and also water play an important role in the degradation process and indicate the part of the polymer that is most susceptible to degradation.

36 MATERIALS SCIENCE↗

Toward precise Q{sub EC} values for the superallowed 0{sup +}->0{sup +} beta decays of T=2 nuclides: The masses of {sup 20}Na, {sup 24}Al, {sup 28}P, and {sup 32}Cl

High-precision measurements of superallowed 0{sup +}->0{sup +} beta decays of T=2 nuclides such as {sup 20}Mg, {sup 24}Si, {sup 28}S, and {sup 32}Ar can contribute to searches for physics beyond the standard model of particle physics if the Q{sub EC} values are accurate to a few keV or better. As a step toward providing precise Q{sub EC} values for these decays, the ground-state masses of the respective daughter nuclei {sup 20}Na, {sup 24}Al, {sup 28}P, and {sup 32}Cl have been determined by measuring the ({sup 3}He,t) reactions leading to them with the {sup 36}Ar({sup 3}He,t){sup 36}K reaction as a calibration. A quadrupole-dipole-dipole-dipole (Q3D) magnetic spectrograph was used together with thin ion-implanted carbon-foil targets of {sup 20}Ne, {sup 24}Mg, {sup 28}Si, {sup 32}S, and {sup 36}Ar. The masses of {sup 20}Na and {sup 32}Cl are found to be in good agreement with the values from the 2003 Atomic Mass Evaluation (AME03) [G. Audi, A. H. Wapstra, and C. Thibault, Nucl. Phys. A 729, 337 (2003)], and the precision has been improved by a factor of 6 in both cases. The masses of {sup 24}Al and {sup 28}P are found to be higher than the values from AME03 by 9.5 keV (3.2sigma) and 11.5 keV (3.6sigma), respectively, and the precision has been improved by a factor of 2.5 in both cases. The new {sup 32}Cl mass is used together with the excitation energy of its lowest T=2 level and the mass of {sup 32}Ar to derive an improved superallowed Q{sub EC} value of 6087.3(22) keV for this case. The effects on quantities related to standard-model tests including the beta-nu correlation coefficient a and the isospin-symmetry-breaking correction delta{sub C} are examined for the A=32 case.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WHAT CAUSES THE INTER-SOLAR-CYCLE VARIATION OF TOTAL SOLAR IRRADIANCE?

The Physikalisch Meteorologisches Observatorium Davos total solar irradiance (TSI), Active Cavity Radiometer Irradiance Monitoring TSI, and Royal Meteorological Institute of Belgium TSI are three typical TSI composites. Magnetic Plage Strength Index (MPSI) and Mount Wilson Sunspot Index (MWSI) should indicate the weak and strong magnetic field activity on the solar full disk, respectively. Cross-correlation (CC) analysis of MWSI with three TSI composites shows that TSI should be weakly correlated with MWSI, and not be in phase with MWSI at timescales of solar cycles. The wavelet coherence (WTC) and partial wavelet coherence (PWC) of TSI with MWSI indicate that the inter-solar-cycle variation of TSI is also not related to solar strong magnetic field activity, which is represented by MWSI. However, CC analysis of MPSI with three TSI composites indicates that TSI should be moderately correlated and accurately in phase with MPSI at timescales of solar cycles, and that the statistical significance test indicates that the correlation coefficient of three TSI composites with MPSI is statistically significantly higher than that of three TSI composites with MWSI. Furthermore, the cross wavelet transform (XWT) and WTC of TSI with MPSI show that the TSI is highly related and actually in phase with MPSI at a timescale of a solar cycle as well. Consequently, the CC analysis, XWT, and WTC indicate that the solar weak magnetic activity on the full disk, which is represented by MPSI, dominates the inter-solar-cycle variation of TSI.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting the fidelity of JPEG2000 compressed CT images using DICOM header information

Purpose: To propose multiple logistic regression (MLR) and artificial neural network (ANN) models constructed using digital imaging and communications in medicine (DICOM) header information in predicting the fidelity of Joint Photographic Experts Group (JPEG) 2000 compressed abdomen computed tomography (CT) images. Methods: Our institutional review board approved this study and waived informed patient consent. Using a JPEG2000 algorithm, 360 abdomen CT images were compressed reversibly (n = 48, as negative control) or irreversibly (n = 312) to one of different compression ratios (CRs) ranging from 4:1 to 10:1. Five radiologists independently determined whether the original and compressed images were distinguishable or indistinguishable. The 312 irreversibly compressed images were divided randomly into training (n = 156) and testing (n = 156) sets. The MLR and ANN models were constructed regarding the DICOM header information as independent variables and the pooled radiologists' responses as dependent variable. As independent variables, we selected the CR (DICOM tag number: 0028, 2112), effective tube current-time product (0018, 9332), section thickness (0018, 0050), and field of view (0018, 0090) among the DICOM tags. Using the training set, an optimal subset of independent variables was determined by backward stepwise selection in a four-fold cross-validation scheme. The MLR and ANN models were constructed with the determined independent variables using the training set. The models were then evaluated on the testing set by using receiver-operating-characteristic (ROC) analysis regarding the radiologists' pooled responses as the reference standard and by measuring Spearman rank correlation between the model prediction and the number of radiologists who rated the two images as distinguishable. Results: The CR and section thickness were determined as the optimal independent variables. The areas under the ROC curve for the MLR and ANN predictions were 0.91 (95% CI; 0.86, 0.95) and 0.92 (0.87, 0.96), respectively. The correlation coefficients of the MLR and ANN predictions with the number of radiologists who responded as distinguishable were 0.76 (0.69, 0.82, p < 0.001) and 0.78 (0.71, 0.83, p < 0.001), respectively. Conclusions: The MLR and ANN models constructed using the DICOM header information offer promise in predicting the fidelity of JPEG2000 compressed abdomen CT images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer

Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training.

Wickwire, P. J.↗