Search NASA⌕ Search

SEARCH · Search NASA

Results for “customize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

DOE Zero Energy Ready Home Case Study: Amaris Custom Homes, St.Paul, Minnesota; DOE Zero Energy Ready Home Case Study, Energy Efficiency & Renewable Energy (EERE)

For this project Amaris worked with U.S. Department of Energy (DOE) team, NorthernSTAR Building America Partnership, to approach zero energy in Minnesota's cold climate using reasonable, cost-effective, and replicable construction materials and practices. The result is a passive solar, super-efficient 3542-ft2 walkout rambler with all the creature comforts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Home Case Study: Amaris Custom Homes, St. Paul, Minnesota

For this project, Amaris worked with U.S. Department of Energy (DOE) team, NorthernSTAR Building America Partnership, to develop the first Zero Energy Ready Home (ZERH) in Minnesota's cold climate using reasonable, cost-effective, and replicable construction materials and practices. The result is a passive solar, super-efficient 3542-ft2 walkout ranch-style home with all the creature comforts. Along with meeting ZERH standards, Amaris also achieved certifications for Leadership in Energy & Environmental Design for Homes v4, MN Green Path Emerald, and a Builders Association of the Twin Cities Reggie Award of Excellence. The home achieves a HERS score of 41 without photovoltaics; with PV, the home achieves a HERS score of 5.

Building America↗

Corpus-based Customization for an Ontology

CCAT scans a corpus of text for terms, and computes lexical similarity between corpus terms and taxonomy terms. Based on a set of metrics and a learning algorithm, the system inserts corpus terms into the taxonomy. Conversely, terms from the taxonomy are disambiguated based on the text in the corpus. Unused terms are discarded, and infrequently used senses of terms are collapsed to make the taxonomy more manageable.

Source record↗

Distributed Energy Resources Customer Adoption Model (DER-CAM), Investment & Planing Version 3.10.5.m

Version 3.10.5 is a multi-year Decision Support tool for Distributed Generation (DG). DER-CAM was initially created as an exclusively economic energy model, able to find the cost minimizing combination and operation profile of a set of DER technologies that meet heat and electric loads of a single building or microgrid for a typical test year. Now, version 3.10.5.m solves for a multiple-year horizon the technology choice question, the appropriate capacity for each selected technology as well as the operational and investment schedule. Optimized investment decisions are based on techno-economic criteria, along with site information such as energy loads, economic forecast, and technology characterization. Version 3.10.5 contains: 1. a PV and battery degradation model and 2. variable performance for technologies. Efficiency, investment costs, etc. can vary over time and model technology breakthroughs and advancements.

Source record↗

Distributed Energy Resources Customer Adoption Model Plus (DER-CAM+), Version 1.0.0

DER-CAM+ v1.0.0 is internally referred to as DER-CAM v5.0.0. Due to fundamental changes from previous versions, a new name (DER-CAM+) will be used for DER-CAM version 5.0.0 and above. DER-CAM+ is a Decision Support Tool for Decentralized Energy Systems that has been tailored for microgrid applications, and now explicitly considers electrical and thermal networks within a microgrid, ancillary services, and operating reserve. DER-CAM was initially created as an exclusively economic energy model, able to find the cost minimizing combination and operation profile of a set of DER technologies that meet energy loads of a building or microgrid for a typical test year. The previous versions of DER-CAM were formulated without modeling the electrical/thermal networks within the microgrid, and hence, used aggregate single-node approaches. Furthermore, they were not able to consider operating reserve constraints, and microgrid revenue streams from participating in ancillary services markets. This new version DER-CAM+ considers these issues by including electrical power flow and thermal flow equations and constraints in the microgrid, revenues from various ancillary services markets, and operating reserve constraints.

Stadler, Michael↗

Automating Nuclear-Safety-Related SQA Procedures with Custom Applications

Nuclear safety-related procedures are rigorous for good reason. Small design mistakes can quickly turn into unwanted failures. Researchers at Oak Ridge National Laboratory worked with COMSOL to define a simulation app that automates the software quality assurance (SQA) verification process and provides results in less than 24 hours.

97 MATHEMATICS AND COMPUTING↗

Quality Assurance on a Custom SiPMs Array for the Mu2e Experiment

The Mu2e experiment at Fermilab will search for the coherent $\mu \to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Energy Resources Customer Adoption Model - Graphical User Interface, Version 2.1.8

The DER-CAM Graphical User Interface has been redesigned to consist of a dynamic tree structure on the left side of the application window to allow users to quickly navigate between different data categories and views. Views can either be tables with model parameters and input data, the optimization results, or a graphical interface to draw circuit topology and visualize investment results. The model parameters and input data consist of tables where values are assigned to specific keys. The aggregation of all model parameters and input data amounts to the data required to build a DER-CAM model, and is passed to the GAMS solver when users initiate the DER-CAM optimization process. Passing data to the GAMS solver relies on the use of a Java server that handles DER-CAM requests, queuing, and results delivery. This component of the DER-CAM GUI can be deployed either locally or remotely, and constitutes an intermediate step between the user data input and manipulation, and the execution of a DER-CAM optimization in the GAMS engine. The results view shows the results of the DER-CAM optimization and distinguishes between a single and a multi-objective process. The single optimization runs the DER-CAM optimization once and presents the results as a combination of summary charts and hourly dispatch profiles. The multi-objective optimization process consists of a sequence of runs initiated by the GUI, including: 1) CO2 minimization, 2) cost minimization, 3) a user defined number of points in-between objectives 1) and 2). The multi-objective results view includes both access to the detailed results of each point generated by the process as well as the generation of a Pareto Frontier graph to illustrate the trade-off between objectives. DER-CAM GUI 2.1.8 also introduces the ability to graphically generate circuit topologies, enabling support to DER-CAM 5.0.0. This feature consists of: 1) The drawing area, where users can manually create nodes and define their properties (e.g. point of common coupling, slack bus, load) and connect them through edges representing either power lines, transformers, or heat pipes, all with user defined characteristics (e.g., length, ampacity, inductance, or heat loss); 2) The tables, which display the user-defined topology in the final numerical form that will be passed to the DER-CAM optimization. Finally, the DER-CAM GUI is also deployed with a database schema that allows users to provide different energy load profiles, solar irradiance profiles, and tariff data, that can be stored locally and later used in any DER-CAM model. However, no real data will be delivered with this version.

Ewald, Friedrich↗