Development of design, qualification, screening, and application requirements for plastic encapsulated solid-state devices for space applications

Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.

Source record↗

Pulse Code Modulation (PCM) data storage and analysis using a microcomputer

A PCM storage device/data analyzer is described. This instrument is a peripheral plug-in board especially built to enable a personal computer to store and analyze data from a PCM source. This board and custom written software turns a computer into a snapshot PCM decommutator. This instrument will take in and store many hundreds or thousands of PCM telemetry data frames, then sift through them over and over again. The data can be converted to any number base and displayed, examined for any bit dropouts or changes in particular words or frames, graphically plotted, or statistically analyzed. This device was designed and built for use on the NASA Sounding Rocket Program for PCM encoder configuration and testing.

Massey, D. E.↗

Feasibility study for a Cryogenic On-Orbit Liquid Depot-Storage, Acquisition and Transfer (COLD-SAT) satellite

This feasibility study presents the conceptual design of a spacecraft for performing a series of cryogenic fluid management flight experiments. This spacecraft, the Cryogenic On-Orbit Liquid Depot-Storage, Acquisition, and Transfer (COLD-SAT) satellite, will use liquid hydrogen as the test fluid, be launched on a Delta expendable launch vehicle, and conduct a series of experiments over a two to three month period. These experiments will investigate the physics of subcritical cryogens in the low gravity space environment to characterize their behavior and to correlate the data with analytical and numerical models of in-space cryogenic fluid management systems. Primary technologies addressed by COLD-SAT are: (1) pressure control; (2) chilldown; (3) no-vent fill; (4) liquid acquisition device fill; (5) pressurization; (6) low-g fill and drain; (7) liquid acquisition device expulsion; (8) line chilldown; (9) thermodynamic state control; and (10) fluid dumping.

Rybak, S. C.↗

KM-IT Mobile Platform for D and D - 18300

Knowledge management (KM) is the practice or process responsible for gathering, analyzing, storing and sharing insights, experiences, knowledge, and information within an organization or community. The main focus of the Knowledge Management Information Tool (KM-IT) for the deactivation and decommissioning (D and D) community is to enhance safety through improved efficiencies (e.g., by reducing the need to rediscover the knowledge and experience gained over time and to promote the reuse of the existing knowledge). KM-IT serves as a centralized information repository and a common interface for D and D related activities. It facilitates the gathering, analysis, storage and sharing of knowledge and information within the D and D community. FIU has developed eight active modules as part of the web-based mobile application for the KM-IT, which can be accessed from m.dndkm.org: Vendor, Specialist Directory, Technology, Picture Library, Hotline, Lessons Learned, Best Practices and Fixatives. All of the mobile modules are scaled-down versions of the desktop module available at www.dndkm.org and publish data from the KM-IT database to the D and D community. FIU has recently developed a native mobile application for Android mobile devices for selecting D and D fixatives. This application runs natively on mobile devices and displays data through the fixative services which uses REST-based API for communication across mobile platforms. Xamarin Forms are used to develop the front-end application for the Android operating system (OS) and will be used for future platforms (iOS and Windows) as well. The native fixative application can be installed on mobile devices to search information related to fixatives, decontamination gels and strippable coatings applicable to D and D. The KM-IT platform includes a comprehensive database of commercially available fixatives and other contamination control products. Search functionality allows the user to filter and sort these products according to the search criteria or keyword. Three levels of refinement are available via a drill down menu for the criteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feng shui of supercomputer memory: positional effects in DRAM and SRAM faults. In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Several recent publications confirm that faults are common in high-performance computing systems. Therefore, further attention to the faults experienced by such computing systems is warranted. In this paper, we present a study of DRAM and SRAM faults in large high-performance computing systems. Our goal is to understand the factors that influence faults in production settings. We examine the impact of aging on DRAM, finding a marked shift from permanent to transient faults in the first two years of DRAM lifetime. We examine the impact of DRAM vendor, finding that fault rates vary by more than 4x among vendors. We examine the physical location of faults in a DRAM device and in a data center; contrary to prior studies, we find no correlations with either. Finally, we study the impact of altitude and rack placement on SRAM faults, finding that, as expected, altitude has a substantial impact on SRAM faults, and that top of rack placement correlates with 20% higher fault rate.

Sridharan, Vilas↗

Interface diagnostics platform for thin-film solid-state batteries

Understanding the impedances of battery materials and their interfaces remains a major challenge, usually addressed by electrochemical impedance spectroscopy (EIS) where frequency-dependent complex impedance of full battery cells is measured and then modeled by a network of connected electrical elements. As conventionally applied, this approach produces ambiguity in that (1) multiple different network configurations may fit the data convincingly and (2) the method offers no direct association of the electrical elements with physical features of the battery. Here we present a new methodology that resolves both sources of ambiguity, enabled by expanding the experimental scope to directly inform the configuration of elements and their parameters in the network model. We demonstrate this methodology using thin film fabrication of solid state battery devices patterned by shadow masked sputter deposition, so that diagnostic devices corresponding to individual interface and material components can be fabricated simultaneously with full cell batteries. EIS models for the diagnostic devices can then be connected to form full cell networks whose topology matches the well-known physical configuration of the battery. When connected in this way, the full network model – made from connecting the diagnostic device EIS models – fits the full cell EIS data. For the case of a thin film solid state battery composed of amorphous silicon anode, lithium phosphorus oxynitride (LiPON) solid electrolyte, and lithium vanadium oxide (Li x V 2 O 5 ) cathode, we show that the approach allows us to identify ionic impedance/conductivity of the cathode/electrolyte as a limiting impedance and the anode/electrolyte interface cycling instability as a primary degradation factor.

25 ENERGY STORAGE↗

Using Micro-Synchrophasor Data for Advanced Distribution Grid Planning and Operations Analysis

This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve/ensure accuracy, providing information on normally estimated values such as underground conductor impedance, and characterization of complex loads. Although the input of high-fidelity data to existing tools will be challenging, µPMU data on phase angle (as well as other data from advanced sensors) will be useful for basic operational decisions that are based on a trend of changing data.

25 ENERGY STORAGE↗

Enhancing Critical Infrastructure and Key Resources (CIKR) Level-0 Physical Process Security Using Field Device Distinct Native Attribute Features

Here, the need for improved Critical Infrastructure and Key Resource (CIKR) security is unquestioned and there has been minimal emphasis on Level-0 (PHY Process) improvements. Wired Signal Distinct Native Attribute (WS-DNA) Fingerprinting is investigated here as a non-intrusive PHY-based security augmentation to support an envisioned layered security strategy. Results are based on experimental response collections from Highway Addressable Remote Transducer (HART) Differential Pressure Transmitter (DPT) devices from three manufacturers (Yokogawa, Honeywell, Endress+Hauer) installed in an automated process control system. Device discrimination is assessed using Time Domain (TD) and Slope-Based FSK (SB-FSK) fingerprints input to Multiple Discriminant Analysis, Maximum Likelihood (MDA/ML) and Random Forest (RndF) classifiers. For 12 different classes (two devices per manufacturer at two distinct set points), both classifiers performed reliably and achieved an arbitrary performance benchmark of average cross-class percent correct of %C > 90%. The least challenging cross-manufacturer results included near-perfect %C ≈ 100%, while the more challenging like-model (serial number) discrimination results included 90%< %C < 100%, with TD Fingerprinting marginally outperforming SB-FSK Fingerprinting; SB-FSK benefits from having less stringent response alignment and registration requirements. The RndF classifier was most beneficial and enabled reliable selection of dimensionally reduced fingerprint subsets that minimize data storage and computational requirements. The RndF selected feature sets contained 15% of the full-dimensional feature sets and only suffered a worst case %CΔ = 3% to 4% performance degradation.

60 APPLIED LIFE SCIENCES↗

Characterization of CNT-MnO{sub 2} nanocomposite by electrophoretic deposition as potential electrode for supercapacitor

Energy crisis that occured in Indonesia suggests that energy supply could not offset the high rate request and needs an electric energy saving device which can save high voltage, safety, and unlimited lifetime. The weakness of batteries is durable but has a low power density while the capacitor has a high power density but it doesn’t durable. The renewal of this study is CNT-MnO{sub 2} thin film fabrication method using electrophoretic deposition. Electrophoretic deposition is a newest method to deposited CNT using power supply with cheap, and make a good result. The result of FTIR analysis showed that the best CNT-MnO{sub 2} composition is 75:25 and C-C bond is detected in fingerprint area. The result is electrode thin film homogen and characterized by X-ray diffraction (XRD) peaks 2θ=26,63° is characterization of graphite, and 2θ=43,97° is characterization of diamond Carbon type and measured by Scherrer formula results 52,3 nm material average size .EIS test results its capacitance about 7,86 F. from the data it can be concluded that CNT-MnO{sub 2} potential electrode very promising for further study and has a potential to be a high capacitance, and fast charge supercapacitor which can be applied for electronic devices, energy converter, even electric car.

36 MATERIALS SCIENCE↗

FLUIDIC: Metal Air Recharged

Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

25 ENERGY STORAGE↗

Shared prefetching to reduce execution skew in multi-threaded systems

Mechanisms are provided for optimizing code to perform prefetching of data into a shared memory of a computing device that is shared by a plurality of threads that execute on the computing device. A memory stream of a portion of code that is shared by the plurality of threads is identified. A set of prefetch instructions is distributed across the plurality of threads. Prefetch instructions are inserted into the instruction sequences of the plurality of threads such that each instruction sequence has a separate sub-portion of the set of prefetch instructions, thereby generating optimized code. Executable code is generated based on the optimized code and stored in a storage device. The executable code, when executed, performs the prefetches associated with the distributed set of prefetch instructions in a shared manner across the plurality of threads.

97 MATHEMATICS AND COMPUTING↗

Side-channel Leakage Assessment Metrics: A Case Study of GIFT Block Ciphers

Determination of an adequate level of security and providing subsequent mechanisms to achieve it, is one of the most pressing problems regarding embedded computing devices. While there are some solutions available for resource-rich computer systems, direct application of these solutions to resource-constrained environments are often unfeasible. The fundamental problem for such resource-constrained systems is the fact that current cryptographic algorithms utilize significant energy consumption and storage overhead. Both the cryptographic algorithm and its physical implementation affect the resilience of a cryptosystem against side-channel attacks. A side-channel attack represents a process that exploits leakages in order to extract sensitive information such as the key. This paper focuses on Correlation Power Analysis (CPA) which is side-channel attack based on the power consumption leakage. In 2016 the U.S. Commerce Department’s National Institute of Standards and Technology (NIST) initiated the call for proposals of new cryptographic algorithms to strengthen the cryptographic defense of networked devices against cyberattacks and to protect the data created by those innumerable device. This work evaluates S-boxes used by NIST candidates PICCOLO, GIFT, and PRESENT, as well as several S-box variants that demonstrated sufficient weaknesses against classical cryptanalysis, for a quantitative comparison in terms of resiliency to CPA attack. Three well-known theoretical metrics are evaluated: transparency order (TO and RTO), nonlinearity, and signal-to-noise (SNR) ratio, aiming to characterize the resistance of these S-boxes against adversaries exploiting physical leakages. Experimental results from attacks on an 8- bit XMEGA were obtained via the ChipWhisperer platform and of all the S-boxes evaluated, GIFT64 with a PICCOLO S-box was found to be the most susceptible to CPA. Results showed that variations in TO and RTO were not sufficient to ensure practical CPA resistance and that among S-boxes with equal non-linearity there were no significant differences in the TO and SNR variants.

97 MATHEMATICS AND COMPUTING↗

Side-channel Leakage Assessment Metrics: A Case Study of GIFT Block Ciphers

Determination of an adequate level of security and providing subsequent mechanisms to achieve it, is one of the most pressing problems regarding embedded computing devices. While there are some solutions available for resource-rich computer systems, direct application of these solutions to resource-constrained environments are often unfeasible. The fundamental problem for such resource-constrained systems is the fact that current cryptographic algorithms utilize significant energy consumption and storage overhead. Both the cryptographic algorithm and its physical implementation affect the resilience of a cryptosystem against side-channel attacks. A side-channel attack represents a process that exploits leakages in order to extract sensitive information such as the key. This paper focuses on Correlation Power Analysis (CPA) which is side-channel attack based on the power consumption leakage. In 2016 the U.S. Commerce Department’s National Institute of Standards and Technology (NIST) initiated the call for proposals of new cryptographic algorithms to strengthen the cryptographic defense of networked devices against cyberattacks and to protect the data created by those innumerable device. This work evaluates S-boxes used by NIST candidates PICCOLO, GIFT, and PRESENT, as well as several S-box variants that demonstrated sufficient weaknesses against classical cryptanalysis, for a quantitative comparison in terms of resiliency to CPA attack. Three well-known theoretical metrics are evaluated: transparency order (TO and RTO), nonlinearity, and signal-to-noise (SNR) ratio, aiming to characterize the resistance of these S-boxes against adversaries exploiting physical leakages. Experimental results from attacks on an 8- bit XMEGA were obtained via the ChipWhisperer platform and of all the S-boxes evaluated, GIFT64 with a PICCOLO S-box was found to be the most susceptible to CPA. Results showed that variations in TO and RTO were not sufficient to ensure practical CPA resistance and that among S-boxes with equal non-linearity there were no significant differences in the TO and SNR variants.

97 MATHEMATICS AND COMPUTING↗

Development of the HyStEP Device

With the introduction of more fuel cell electric vehicles (FCEVs) on U.S. roadways, especially in California, the need for available hydrogen refueling stations is growing. While funding from the California Energy Commission is helping to solve this problem, solutions need to be developed and implemented to help reduce the time to commission a hydrogen station. The current practice of hydrogen station acceptance can take months because each vehicle manufacturer conducts their own testing and evaluation. This process is not practical or sufficient to support the timely development of a hydrogen fueling station network. To address this issue, as part of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project Sandia National Laboratories and the National Renewable Energy Laboratory along with a team of stakeholders and contractor Powertech Labs has developed the Hydrogen Station Equipment Performance (HyStEP) Device. The HyStEP Device is intended to be a surrogate for FCEVs that can be used to collect data on hydrogen station fueling performance. The device includes three Type IV 70 MPa tanks capable of storing a total of 9 kg H2 that are instrumented with pressure and temperature sensors. The tanks can be used individually or in parallel to simulate small, medium, and large fuel systems. The tanks are connected to a 70 MPa receptacle equipped with pressure and temperature sensor as well as infrared communications integrated with a data acquisition, analysis, and control system. The HyStEP Device is capable of performing tests defined in the test method standard CSA HGV 4.3 and providing the data needed to ensure that hydrogen stations meet the fueling protocol standard SAE J2601-2014. These include IrDA communication tests, fault detection tests, and communication and non-communication fueling.

30 DIRECT ENERGY CONVERSION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Enhanced electrocaloric effect in displacive-type organic ferroelectrics

We explore the intrinsic feature of electrocaloric effect (ECE) accompanied by ferroelectric (FE)-paraelectric (PE) transition for displacive-type organic ferroelectrics using Green's function theory. It is demonstrated that decreasing elastic constant K or increasing spin-lattice coupling λ can enhance the ECE, as well as polarization P and transition temperature T{sub C}. Indeed, one expects that the optimal operating temperature for solid-state refrigeration is around room temperature, at which the ECE achieves its maximum. As T{sub C} is tuned to ∼310 K, it presents larger ECE response and remanent polarization with lower coercive field for smaller K value, suggesting that well flexible displacive-type organic ferroelectrics are excellent candidates both for electric cooling and data storage in the design of nonvolatile FE random-access memories. Furthermore, in an electric field, it provides a bridge between a Widom line that denotes FE-PE crossover above T{sub C} and a metaelectric transition line below T{sub C} that demonstrates an FE switching behavior with an antiparallel field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗