Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

You Only Look Once v5 and Multi-Template Matching for Small-Crack Defect Detection on Metal Surfaces

This paper compares the performance of Deep Learning (DL) and multi-template matching (MTM) models for detecting small defects. DL models extract distinguishing features of objects but require a large dataset of images. In contrast, alternative computer vision techniques like MTM need a relatively small dataset. The lack of large datasets for small metal-surface defects has inhibited the adoption of automation in small-defect detection in remanufacturing settings. This motivated this preliminary study to compare template-based approaches, like MTM, with feature-based approaches, such as DL models, for small-defect detection on an initial laboratory and remanufacturing industry dataset. This study used You Only Look Once v5 (YOLOv5) as the DL model and compared its performance against the MTM model for small-crack detection. The findings of our preliminary investigation are as follows: (i) YOLOv5 demonstrated higher performance than MTM in detecting small cracks; (ii) an extra-large variant of YOLOv5 outperformed a small-size variant; (iii) the size and object variety of the data are crucial in achieving robust pre-trained weights for use in transfer learning; and (iv) enhanced image resolution contributes to precise object detection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Dislocation Characterization by Electron Channeling Contrast Imaging and Cross-Correlation Electron Backscattered Diffraction

The characterization and quantification of dislocations is predominately carried out using transmission electron microscopy (TEM). Nevertheless, the sample preparation necessary for TEM foils can be cumbersome and possibly introduce defects. Two other techniques for characterizing and quantifying dislocations are electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD). ECCI is similar to TEM in that specific imaging (channeling or diffraction) conditions need to be established, but is carried out in a scanning electron microscope on bulk samples, resulting in less complex sample preparation. CC-EBSD measures subtle changes in orientation measured from EBSD patterns to calculate elastic strains and the Nye tensor to deduce and map the total geometrically necessary dislocation (GND) content. Furthermore, this work presented here compares the capabilities of ECCI and CC-EBSD to map dislocations generated from nanoindentation.

42 ENGINEERING↗

Chiral, Topological, and Knotted Colloids in Liquid Crystals

The geometric shape, symmetry, and topology of colloidal particles often allow for controlling colloidal phase behavior and physical properties of these soft matter systems. In liquid crystalline dispersions, colloidal particles with low symmetry and nontrivial topology of surface confinement are of particular interest, including surfaces shaped as handlebodies, spirals, knots, multi-component links, and so on. These types of colloidal surfaces induce topologically nontrivial three-dimensional director field configurations and topological defects. Director switching by electric fields, laser tweezing of defects, and local photo-thermal melting of the liquid crystal host medium promote transformations among many stable and metastable particle-induced director configurations that can be revealed by means of direct label-free three-dimensional nonlinear optical imaging. The interplay between topologies of colloidal surfaces, director fields, and defects is found to show a number of unexpected features, such as knotting and linking of line defects, often uniquely arising from the nonpolar nature of the nematic director field. This review article highlights fascinating examples of new physical behavior arising from the interplay of nematic molecular order and both chiral symmetry and topology of colloidal inclusions within the nematic host. Furthermore, the article concludes with a brief discussion of how these findings may lay the groundwork for new types of topology-dictated self-assembly in soft condensed matter leading to novel mesostructured composite materials, as well as for experimental insights into the pure-math aspects of low-dimensional topology.

chirality↗

Dynamic Measurements of the Structural Evolution of Material Defects at the Mesoscale

This is a technical report to be published as part of the FY2021 annual overview package. We have designed experiments and developed analytical methods using images from x-ray and electron microscopy in order to quantify the behavior of crystal dislocation defects at their native nanometer-length and micro-length scales. The results of these analyses are used to directly inform theoretical physics models and guide interpretation of dark field x-ray microscopy (DFXM) images that offer spatial resolution surpassing the resolution of beamline optics. Additionally, we developed new analytical methods to automate the alignment of optics hardware used in both synchrotron and x-ray free electron laser beamline facilities. The tools and workflows developed for this project are now being deployed as proof-of-concept in reaction history analysis (RHA) for future programmatic integration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHARACTERIZATION OF PD IMPURITIES AND TWIN BOUNDARY DEFECTS IN DETECTOR GRADE CDZNTE CRYSTALS

Synthetic CdZnTe or ''CZT'' crystals are highly suitable for {gamma}-spectrometers operating at the room temperature. Secondary phases (SP) in CZT are known to inhibit detector performance, particularly when they are present in large numbers or dimensions. These SP may exist as voids or composites of non-cubic phase metallic Te layers with bodies of polycrystalline and amorphous CZT material and voids. Defects associated with crystal twining may also influence detector performance in CZT. Using transmission electron microscopy, we identify two types of defects that are on the nano scale. The first defect consists of 40 nm diameter metallic Pd/Te bodies on the grain boundaries of Te-rich composites. Although the nano-Pd/Te bodies around these composites may be unique to the growth source of this CZT material, noble metal impurities like these may contribute to SP formation in CZT. The second defect type consists of atom-scale grain boundary dislocations. Specifically, these involve inclined ''finite-sized'' planar defects or interfaces between layers of atoms that are associated with twins. Finite-sized twins may be responsible for the subtle but observable striations that can be seen with optical birefringence imaging and synchrotron X-ray topographic imaging.

36 MATERIALS SCIENCE↗

Automated Fiber Placement Defects: Automated Inspection and Characterization

Automated Fiber Placement (AFP) is an additive composite manufacturing technique, and a pressing challenge facing this technology is defect detection and repair. Manual defect inspection is time consuming, which led to the motivation to develop a rapid automatic method of inspection. This paper suggests a new automated inspection system based on convolutional neural networks and image segmentation tasks. This creates a pixel by pixel classification of the defects of the whole part scan. This process will allow for greater defect information extraction and faster processing times over previous systems, motivating rapid part inspection and analysis. Fine shape, height, and boundary detail can be generated through our system as opposed to a more coarse resolution demonstrated in other techniques. These scans are analyzed for defects, and then each defect is stored for export, or correlated to machine parameters or part design. The network is further improved through novel optimization techniques. New training instances can also be created with every new part scan by including the machine operator as a post inspection check on the accuracy of the system. Having a continuously adapting inspection system will increase accuracy for automated inspections, cutting down on false readings.

Sacco, Christopher↗

Collimated Beams for Cement Evaluation [Slides]

This presentation discusses how there are no commercial acoustic sources that provide a collimated beam over a frequency range of 10–250 kHz in a small package that works in different media. A recently improved acoustic source – ACCObeam, however, is much more powerful than its predecessor (which was based on nonlinear acoustics). This presentation also demonstrated imaging capabilities of the system, in both open and cased-borehole, for different induced defects (groove, detachment, fluid-filled void pocket, casing). Future R&D includes refining and enhancing the capabilities of the 3D imaging system for more realistic environments, extending investigation range beyond the wellbore casing, and identify new applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Additive manufacturing process parameter determination for a new Fe-C-Cu alloy

As a potential replacement for stainless steel alloys commonly used to print parts with laser powder bed fusion, a new Cu precipitation strengthened ferrous alloy, with composition Fe-0.2C-6Cu (wt%), was recently developed. This material is Co- and Ni-free, printable, has mechanical properties comparable to that of high strength stainless steels (approximately 1300 MPa UTS), and is cost-advantaged relative to existing low-alloy steels for additive manufacturing of parts with complex shapes. To gain traction for broader application, optimal laser powder bed fusion (LPBF) processing conditions to produce nearly defect-free parts without compromising mechanical strength are needed. Here, an optimal processing window based upon laser speeds that achieve minimal porosity was quantified via comparisons of measured melt pool penetration, scan speeds, printed material density and laser beam energy density on a commercial LPBF unit operating at 350 W, 80 μm hatch spacing, and 50 μm layer thickness based upon optimal parameters for 17-4PH. Furthermore, the window is 300 to 500 mm/s to achieve >99.8 % dense Fe-0.2C-6Cu (wt%) specimens. Other defects such as burning, spatter, and lack of fusion were also avoided in this window. The window was validated with in-situ synchrotron X-ray imaging that enabled visualization of the vapor cavity, melting, and solidification during a single laser track scan on a miniature powder bed sample. In addition, in-situ infrared imaging provided temperature fields, cooling rate and solidification range, and confirmed minimal printing defects and spatter within the processing window.

36 MATERIALS SCIENCE↗

Static and dynamic topological defects in the domain textures in the helical antiferromagnet Ni 2 ⁢CoTeO 6

Real-space Bragg coherent x-ray-diffractive imaging unveils the formation of bubble and stripe antiferromagnetic (AFM) phase domains on the surface of Ni 2 ⁢CoTeO 6 single crystal. The stripe domains exhibit dislocation-type topological defects. The defects typically form as defect-antidefect pairs and can be created or annihilated by temperature changes and local heating. Thermal fluctuations of the AFM domain walls are observed near the Néel temperature. Topological defect pairs dynamically form and disappear in the fluctuating state. These observations provide a real-space perspective on the dynamics of the AFM phase transition in a helical antiferromagnet. Finally, the remarkable tunability of AFM domain walls in a helical antiferromagnet underscores their potential for AFM spintronics applications.

36 MATERIALS SCIENCE↗

System and process for detecting and monitoring surface defects

A system and process for detecting and monitoring defects in large surfaces such as the field joints of the container segments of a space shuttle booster motor. Beams of semi-collimated light from three non-parallel fiber optic light panels are directed at a region of the surface at non-normal angles of expected incidence. A video camera gathers some portion of the light that is reflected at an angle other than the angle of expected reflectance, and generates signals which are analyzed to discern defects in the surface. The analysis may be performed by visual inspection of an image on a video monitor, or by inspection of filtered or otherwise processed images. In one alternative embodiment, successive predetermined regions of the surface are aligned with the light source before illumination, thereby permitting efficient detection of defects in a large surface. Such alignment is performed by using a line scan gauge to sense the light which passes through an aperture in the surface. In another embodiment a digital map of the surface is created, thereby permitting the maintenance of records detailing changes in the location or size of defects as the container segment is refurbished and re-used. The defect detection apparatus may also be advantageously mounted on a fixture which engages the edge of a container segment.

Mueller, Mark K.↗

Point Defects Control Guest Molecule Diffusion in the 1D Pores of Zn(tbip)

Molecular diffusion plays a critical role in metal-organic frameworks (MOFs) within the application of kinetic chemical separations. We carefully study in this work the unexpected role of point defects for short-chain alkanes diffusing in Zn(tbip), an MOF with rigid one-dimensional (1D) channels. Inside a defect-free Zn(tbip), guest molecules are expected to follow single-file diffusion along 1D channels. It has been found previously by Heinke et al. that these parallel 1D channels are connected for molecular diffusion. Our density functional theory (DFT) calculations suggest that linker vacancy defects could arise under experimentally relevant conditions by removing a pair of linkers. Further climbing-image nudged elastic band (cNEB) DFT calculations indicate that hopping of short-chain alkanes between adjacent 1D channels over defect windows can occur at moderate temperatures. In addition to providing insights into connected adjacent 1D channels in Zn(tbip), Heinke et al. also inferred that most 1D pores are blocked from a microkinetic model. Additionally, we explored the influence of hydrolyzed linker created by the formation of linker removal inside 1D pores. Our DFT calculations show that the linkers can effectively block the pores and the linker diffusion in 1D channels is slow. Our results, for the first time, offer a mechanistic explanation of the unexpected molecular diffusion behavior in this MOF with 1D channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excitation-Dependent Recombination and Diffusion Near an Isolated Dislocation in GaAs

In low-magnification, plan-view photoluminescence images of a nominally lattice-matched, undoped GaAs/GaInP heterostructure, we observe a random distribution of isolated dark spots. We attribute the dark spots to crystal dislocations, where nonradiative recombination is augmented by transitions utilizing defect-related energy levels between the conduction and valence bands. We note that, when the laser excitation intensity is reduced, the darkened regions expand. At lower excitation, the density of photogenerated electrons and holes is reduced, and they are more likely to reach the defective region before encountering a partner for radiative recombination. When we model the behavior with a simulation that allows for Laplacian diffusion and defect-related recombination only through mid-bandgap energy levels, we do not obtain good agreement between experimental and simulated images. But if we allow for an arbitrary distribution of defect levels, such that the occupation of the levels and bands can change independently, we have more flexibility for fitting the density-dependent recombination rates. The more sophisticated model produces results that are more consistent with experimental images.

14 SOLAR ENERGY↗

PTT System Performance Evaluation in 3-D Imaging of AM Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for non-destructive evaluation (NDE) either during or post manufacturing. Known material flaws in AM include low density regions consisting of nonsintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This study investigates the capability of PTT in imaging several AM structures fabricated from Inconel 718 (IN718) feedstock. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of IN718 nozzle plate and a particle filter plate. The results demonstrate the capability of PTT in 3- D imaging of complex geometry AM structures. Further, increased resolution imaging is achieved compared to prior results using older FLIR SC4000 IR camera. In addition, preliminary studies were conducted on developing image processing algorithms for automated detection of flaws. Initial demonstrations are shown for segmentation of PTT images of flat bottom hole (FBH) specimens. Imaging of FBH specimens was described in a prior report. Intermediate results demonstrated in this report will be developed further in detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deep Learning of Atomically Resolved Scanning Transmission Electron Microscopy Images: Chemical Identification and Tracking Local Transformations

Recent advances in scanning transmission electron and scanning probe microscopies have opened unprecedented opportunities in probing the materials structural parameters and various functional properties in real space with an angstrom-level precision. This progress has been accompanied by exponential increase in the size and quality of datasets produced by microscopic and spectroscopic experimental techniques. These developments necessitate adequate methods for extracting relevant physical and chemical information from the large datasets, for which a priori information on the structures of various atomic configurations and lattice defects is limited or absent. Here we demonstrate an application of deep neural networks to extracting information from atomically resolved images including location of the atomic species and type of defects. We develop a “weakly-supervised” approach that uses information on the coordinates of all atomic species in the image, extracted via a deep neural network, to identify a rich variety of defects that are not part of an initial training set. We further apply our approach to interpret complex atomic and defect transformation, including switching between different coordination of silicon dopants in graphene as a function of time, formation of peculiar silicon dimer with mixed 3-fold and 4-fold coordination, and the motion of molecular “rotor”. In conclusion, this deep learning based approach resembles logic of a human operator, but can be scaled leading to significant shift in the way of extracting and analyzing information from raw experimental data.

36 MATERIALS SCIENCE↗

Machine Learning Algorithms for Automated NIF Capsule Mandrel Selection

Small shells, approximately 2 mm in diameter, made from Poly(α-methylstyrene) (PAMS) are used as mandrels in the production of glow discharge polymer capsules located at the center of inertial confinement fusion experiments. The visual inspection process of microscope images of these shell mandrels, including detection of micron-sized defects on the shell surface as well as the handling and sorting, is a very labor-intensive, repetitive, and highly subjective process that stands to benefit greatly from automation. As part of an effort to decrease the number of labor hours spent in capsule handling, inspection, and metrology, the development of robotic systems was presented in a paper by Carlson et al., “Automation in Target Fabrication” [Fusion Sci. Technol., Vol. 70, p. 274 (2016)]. The current work expands the automated image acquisition systems developed previously and adds the use of convolutional neural networks to select capsules best suited for use in the downstream production process. Through the use of these machine learning algorithms, the selection process becomes robust, repeatable, and operator independent. Finally, as an added benefit the system developed as part of this work is able to provide defect statistics on entire shell batches and feed this information upstream to the production team.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving compliance with Intersocietal Accreditation Commission (IAC) reporting standards: A serial comparison of 523 labs over seven years

Background: The aim of this study was to evaluate reporting compliance of laboratories applying for serial accreditation by the Intersocietal Accreditation Commission (IAC) and compare compliance based on laboratory characteristics. Methods: All laboratories applying for IAC accreditation for the first time in 2008 and then twice more (2011-2014) were evaluated for compliance with 18 reporting elements. The elements were ranked into three severity groups (high/moderate/low). Results: Reports from 523 laboratories were evaluated. The percentage of laboratories with reporting issues by cycle was 66.2% for cycle 1, 36.7% for cycle 2, and 43.8% for cycle 3 (p < .001). For most of the 18 elements, there was a significant decrease in the percentage of labs with issues. Less moderate and high severity errors were seen over time. Also, the mean non-compliant elements per laboratory decreased from 5.78 ± 2.72 at cycle 1, down to 1.25 ± 1.77 at cycle 3. Conclusions: In facilities applying for 3 consecutive IAC accreditation cycles, reporting compliance with IAC Standards improved between cycles 1-2 and 1-3. No significant improvement occurred between cycles 2-3. Although the quality of reports improved overall, problems remain in quantifying myocardial perfusion defects, documenting report approval date, and integrating stress and imaging reports.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward fully automated UED operation using two-stage machine learning model

To demonstrate the feasibility of automating UED operation and diagnosing the machine performance in real time, a two-stage machine learning (ML) model based on self-consistent start-to-end simulations has been implemented. This model will not only provide the machine parameters with adequate precision, toward the full automation of the UED instrument, but also make real-time electron beam information available as single-shot nondestructive diagnostics. Furthermore, based on a deep understanding of the root connection between the electron beam properties and the features of Bragg-diffraction patterns, we have applied the hidden symmetry as model constraints, successfully improving the accuracy of energy spread prediction by a factor of five and making the beam divergence prediction two times faster. The capability enabled by the global optimization via ML provides us with better opportunities for discoveries using near-parallel, bright, and ultrafast electron beams for single-shot imaging. It also enables directly visualizing the dynamics of defects and nanostructured materials, which is impossible using present electron-beam technologies.

36 MATERIALS SCIENCE↗