Search NASASearch

SEARCH · Search NASA

Results for “electrified thermal energy storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,650 records · Page 36

Development of global/chemistry model for jet-fuel thermal stability based on observations from static and flowing experiments

Two global-chemistry models for oxidative deposition of jet fuels are evaluated by integrating them into a Computational Fluid Dynamics with Chemistry (CFDC) code. A previously developed two-step global-chemistry model was found to be insufficient to describe the thermal-oxidation and -deposition rates associated with a Jet-A fuel. A new global-chemistry model has been developed systematically based on observations from flowing and static experiments. The global-autoxidation reaction is modified such that the reaction rate becomes zeroth-order with respect to the dissolved oxygen concentration. The generation of deposit-forming precursor is coupled with the autoxidation reaction by introducing a radical species ROO. A formulation for the sticking probability has also been developed. Deposition profiles are well represented by this new model under a variety of temperature and flow conditions. The model correctly predicts the changes in magnitude and spatial location of the deposition peak due to changes in flow. The CFDC model, which is designed for flowing systems, has been extended to static experiments. The model incorporates a non-depleting species F(sub s) representing all non-oxygen compounds responsible for deposition. Static experiments were found to provide a useful and inexpensive method for estimating the concentration of F(sub s) in the fuel.

V. R. Katta

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

numerical simulations

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

sting arm

Flame retardant biogenic building insulation materials from hemp fiber

Biogenic thermal insulation materials are in high demand because of its carbon-sequestration nature. However, high flammability, moisture condensation, and relatively high thermal conductivity of biogenic material are major concerns for sustainable building applications. In this study, we report the fire-retardant cellulose xerogel insulation nanocomposites derived from hemp fiber recycling and silica xerogel, in which the boric acid treatment improves its fire retardancy. The as-prepared materials show a low thermal conductivity of 31.3 mW/m K, high flexural modulus of 665 MPa, hydrophobicity with the water contact angle of 115°, and fire retardancy with 30% weight loss over a period of burning time 10 min. Overall, this work provides an effective method for the synthesis of fire-retardant biogenic thermal insulation materials and shows a promising way for next-generation bio-based insulation materials.

36 MATERIALS SCIENCE

Construction of an Exact Pressure-Equilibrium Scheme for the Five-Equation Two-Phase Flow Model With Thermal Relaxation

Numerical simulation of compressible multiphase flows based on the four-equation (homogeneous relaxation) model is known to suffer from two fundamental difficulties with (a) wave propagation and (b) pressure equilibrium preservation. First, the mixture sound speed exhibits non-monotonic dependency with respect to the volume fraction, which leads to robustness issues in the resolution of shocks and acoustic wave propagation across two-phase regions. This difficulty can be mitigated by solving Allaire’s five-equation model augmented with infinitely fast phasic temperature equilibrium, from which solutions of the four-equation model can be recovered. However, when temperature is non-uniform, this augmented five-equation formulation still fails to preserve pressure equilibrium across material interfaces. In this work, we propose a fully conservative numerical scheme that exactly preserves pressure equilibrium at the discrete level for the augmented five-equation model, for arbitrary initial distributions of temperature and volume fraction. Combined with the monotonic sound speed property of the five-equation formulation, the proposed pressure-equilibrium preserving scheme significantly improves robustness in the presence of strong multiphase interactions, including shock–interface interactions and advection of material interfaces.

ESG

Criteria for Retention of 3013 S1 Containers Based on Relative Risk and Expert Judgment

An evaluation was performed to assess the suitability of thirty-three 3013 containers proposed for retention. These containers have moisture levels greater than 0.08 wt.% – the S1 population. The remainder of the S1 population stored at SRS will be down blended and disposed of by the end of 2028. Based on field surveillance and shelf-life data available to date as well as informed technical judgment, no container is currently expected to fail in its 50-year storage period. However, corrosion risk varies across the S1 population. Relative risks were evaluated using predicted Consensus Scores and their 95% Upper Prediction Limits (UPLs). The predicted values are based on a statistical model of Consensus Score as a function of moisture, chloride, and whether the packaged material was electrorefining scrap packaged at Hanford. Consensus Score has been shown to be a useful indicator of corrosion potential, and the UPL captures uncertainty in the model predictions, providing a conservative indicator of corrosion potential. Using UPLs to determine relative risks, together with expert review, three containers were identified as not suitable for retention, and the remainder were determined to be suitable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Space Nuclear Propulsion for Space Applications: Multi-Mission Nuclear Thermal Propulsion Vehicle Design

This NASA Technical Memorandum (TM) is intended to capture design work that the Advanced Concepts Office (ACO) at NASA’s Marshall Space Flight Center (MSFC) performed on behalf of the Space Nuclear Propulsion (SNP) Project during an SNP-driven design and mission analysis initiative in FY2025. Specifically, this TM focuses on several spacecraft design concepts intended to explore the feasibility of nuclear thermal propulsion (NTP) for use in a selection of notional, unmanned space missions. While references to the missions will be made in this TM, the primary focus will be on the spacecraft design concepts themselves, the ground rules and assumptions used for designing the spacecraft, a description of the various subsystems and their performance parameters, and the methodologies used to design them. The TM will also highlight areas of future work and additional considerations that may need to be taken into account when evaluating the feasibility of NTP space systems for other applications. The report will discuss the results from ACO’s analysis as they pertain to the different vehicle concepts that were evaluated. Each discipline section in this report will discuss the discipline-specific ground rules and assumptions, the methodology and design approaches employed, and present the results along with any relevant discussion, and highlight areas of future work where applicable.

Mitchell A Rodriguez

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

Adapter Signaling Evaluations on EVs [Slides]

In case J3400 and J3400/1 define a basic analog signaling approach for DC charging adapters to communicate over-temperature events to both the EV and EVSE. They also require the EV to implement mitigation and corrective actions in cases where the EVSE does not respond to adapter thermal signals. In this study, multiple production vehicles were evaluated for responsiveness to assess field readiness and ensure consistent performance in accordance with the SAE J1772, J3400 and J3400/1 standards. A series of test cases were developed and executed across different vehicles, using an adapter thermal breakout fixture designed by NLR for evaluations. The results revealed notable variations in behavior: some vehicles expected to comply with J1772 were found to be non-responsive under certain conditions. Additionally, while some EV OEMs appear to align with the J3400 standard, discrepancies exist due to its evolving nature, resulting in inconsistent implementation of the latest requirements. These findings highlight the need for alignment within standards organizations to ensure consistent interpretation, encourage compliance, and reduce potential confusion across implementations.

33 ADVANCED PROPULSION SYSTEMS

Recent Developments in Safe Lithium Ion Battery Design for Human Space Flight

This presentation provides an overview of EVA batteries and introduces the concept of designing lithium ion batteries that resist the propagation of a single cell catastrophic failure. Thermal runaway initiation methods are briefly discussed, and the safe performance of the resulting designs is summarized. Approached in an incremental fashion, each subsequent battery design is introduced, ending with a current development for the Exploration EVA spacesuit. Challenges in achieving safe design performance with limited internal volume are briefly discussed and forward work is identified. Video examples of both propagating and non-propagating designs are included.

lithium ion

Thermally Stable Co@C3N4 Single-Atom Catalysts for CO Oxidation: Atomic-Level Insights into Structure and Activity

Single Co atoms supported on C3N4 (Co@C3N4) have demonstrated high activity and selectivity in photocatalysis. However, the investigation of structure–function relationships and reaction mechanisms under photocatalytic conditions is very challenging due to the complex conditions of light absorption, charge transfer, and catalysis. In this study, we employed thermal CO oxidation as a prototypical probe reaction to benchmark the intrinsic catalytic performance and track the active-site evolution of Co@C3N4. Single Co atoms were identified and shown to be the catalytically active sites for CO oxidation based on control experiments and isotope-labeling experiments. The Co sites remained atomically dispersed before, during, and after the reaction with temperatures up to 400 °C, as established by in situ X-ray absorption fine structure (XAFS) combined with density functional theory (DFT), FDMNES simulations, and dynamic-time-warping (DTW)-assisted X-ray absorption near edge structure (XANES) matching. Together with theoretical calculations, the integrated analysis reveals a stable coordination environment under reaction conditions, which correlates with sustained activity, establishing Co@C3N4 single-atom catalysts as thermally stable CO oxidation catalysts. Beyond these findings, the current study provides a workflow for unambiguously assigning active sites in Co@C3N4 for thermal CO oxidation. This workflow will aid the understanding of their behavior in photocatalysis in the future, where light-driven dynamics obscure direct structure–function links. Notably, this study provides fundamental insights for the rational design of robust single-atom catalysts and a foundation for the broader application of Co@C3N4 catalysts in oxidation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

NIAC Phase I Final Report Lunar South Pole Oxygen Pipeline (LSPOP)

The Lunar South Pole Oxygen Pipeline (LSPOP) Phase I NIAC, is to analyze the feasibility of constructing a pipeline at the Moon’s South Pole for transporting gaseous oxygen from point of generation to point of use. A lunar pipeline has never been pursued and will revolutionize lunar surface operations for the Artemis program and reduce cost and risk. Our starting concept is for a 5 km pipeline to transport oxygen gas from an oxygen production source, for example from our molten regolith electrolysis (MRE, currently at TRL 5, see references[1],[2],[3],[4],[5],[6] for technical discussions of the MRE process) extraction site, or any other source, to an oxygen storage/liquification plant near a lunar base. The pipeline is designed to: 1) be constructed robotically from regolith-derived metals with minimal material transferred from Earth, 2) be repairable robotically, 3) have an oxygen flow rate of ~2 kg/hour, which is commensurate with the NASA initial projected need of 10,000 kg/year, 4) operate with minimal power over the lifetime of the pipeline, with a goal of high operational reliability and the ability to survive in the lunar environment for > 10 years. We compare this concept to a pipeline concept with pipe produced on Earth and then transported to and assembled on the Moon. Both approaches will use earth-based compressors, valves, and fittings which are integrated into the pipeline on the Moon.

NIAC Phase I

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Ajay S Gill

Long Life Molten Salt Battery for NASA Venus Application

A development program is being conducted at Advanced Thermal Batteries (ATB) to create a low discharge rate, long life, molten salt battery for a NASA Venus surface probe. Battery goals are 60 days continuous operation at +25V +0/-6 volts and -25V +6/-0 Volts under severe environments of 465°C, 92 atm pressure, and corrosive sulfur dioxide in a super critical carbon dioxide atmosphere. Conveniently, molten salt thermal battery electrochemistry starts to operate efficiently at 330°C. However, a major barrier to direct application of existing thermal battery technology is the high self-discharge rate, resulting in lifetimes in only minutes, not days. The best performance to date, which meets the required voltage regulation, has been a lithium silicon (LiSi) alloy anode discharging through all three voltage plateau versus an iron monosulfide (FeS) cathode. In order to perform reproducibly, additional engineering controls within the battery design are required to limit cell–to–cell parasitic discharge mechanisms. Results of these trials have improved the efficiency and manufacturability of the design.

Thermal Battery

Microbiological Characterization and Concerns of the International Space Station Internal Active Thermal Control System

Since January 1999, the chemical the International Space Station Thermal Control System (IATCS) and microbial state of (ISS) Internal Active fluid has been monitored by analysis of samples returned to Earth. Key chemical parameters have changed over time, including a drop in pH from the specified 9.5 +/- 0.5 ta = 58.4, an increase in the level of total inorganic carbon (TIC), total organic carbon (TOC) and dissolved nickel (Ni) in the fluid, and a decrease in the phosphate (PO,) level. In addition, silver (AS) ion levels in the fluid decreased rapidly as Ag deposited on internal metallic surfaces of the system. The lack of available Ag ions coupled with changes in the fluid chemistry has resulted in a favorable environment for microbial growth. Counts of heterotrophic bacteria have increased from less than 10 colony-forming units (CFUs)/l00 mL to l0(exp 6) to l0(exp 7) CFUs/100 mL. The increase of the microbial population is of concern because uncontrolled microbiological growth in the IATCS can contribute to deterioration in the performance of critical components within the system and potentially impact human health if opportunistic pathogens become established and escape into the cabin atmosphere. Micro-organisms can potentially degrade the coolant chemistry; attach to surfaces and form biofilms; lead to biofouling of filters, tubing, and pumps; decrease flow rates; reduce heat transfer; initiate and accelerate corrosion; and enhance mineral scale formation. The micro- biological data from the ISS IATCS fluid, and approaches to addressing the concerns, are summarized in this paper.

Monsi C Roman

Photosynthetic capacity is reduced by warming but unaffected by elevated CO2 in seedlings of five boreal tree species

Abstract Increasing atmospheric CO2 concentrations fuel global warming, with boreal regions warming at a faster rate than many other areas. Boreal forests are an important component of the global carbon cycle, yet we have little data on photosynthetic responses of boreal trees to elevated CO2 (EC) and warming. We grew seedlings of 5 widespread North American boreal tree species (from Betula, Larix, Picea, and Pinus) under current (410 ppm) or elevated (750 ppm) CO2 and either ambient (+0 °C) or increased (+4 °C or +8 °C) temperature, then measured photosynthetic traits over a range of leaf temperatures. Our results were generally consistent across species: photosynthetic capacity (maximum rates of Rubisco carboxylation, Vcmax, and electron transport, Jmax) was unaffected by EC but decreased under +8 °C warming. Accordingly, net photosynthesis measured at the growth CO2 concentration (Agrowth) was reduced under warming and increased under EC. The thermal optimum for Agrowth (ToptA) increased by ∼1.8 °C with EC but increased with warming in only two species. In contrast, the activation energies and thermal optima for Vcmax and Jmax, which are used to estimate photosynthesis in Earth System Models, were unaffected by growth environment. There were a few interactions between growth, CO2, and warming. These results suggest increased photosynthesis of widespread boreal tree species under EC may be offset by future reductions in photosynthetic capacity related to warming. We also show that the temperature sensitivities of parameters used to estimate global photosynthesis in large-scale models are generally unaffected by simulated climate change in these species.

Plant Sciences

Mechanically and Thermally Robust Gel Electrolytes Built from A Charged Double Helical Polymer

Polymer electrolytes have received tremendous interest in the development of solid-state batteries, but often fall short in one or more key properties required for practical applications. Herein, a rigid gel polymer electrolyte prepared by immobilizing a liquid mixture of a lithium salt and poly(ethylene glycol) dimethyl ether with only 8 wt% poly(2,2′-disulfonyl-4,4′-benzidine terephthalamide) (PBDT) is reported. The high charge density and rigid double helical structure of PBDT lead to formation of a nanofibrillar structure that endows this electrolyte with stronger mechanical properties, wider temperature window, and higher battery rate capability compared to all other poly(ethylene oxide) (PEO)-based electrolytes. The ion transport mechanism in this rigid polymer electrolyte is systematically studied using multiple complementary techniques. Li/LiFePO 4 cells show excellent capacity retention over long-term cycling, with thermal cycling reversibility between ambient temperature and elevated temperatures, demonstrating compelling potential for solid-state batteries targeting fast charging at high temperatures and slower discharging at ambient temperature.

36 MATERIALS SCIENCE