Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A novel conditional generative model for efficient ensemble forecasts of state variables in large-scale geological carbon storage

Integrating monitoring data to efficiently update reservoir pressure and CO 2 plume distribution forecasts presents a significant challenge in geological carbon storage (GCS) applications. Inverse modeling techniques are commonly used to fuse observational data and refine reservoir model parameters, thereby improving state variable forecasts. However, these techniques often rely on linear or Gaussian assumptions, which can limit their effectiveness in accurately predicting state variables. Moreover, simulating large-scale three-dimensional (3D) GCS problems is computationally expensive, making iterative runs in inverse problems prohibitive. To address these challenges, we propose a conditional generative model utilizing the score-based diffusion method for real-time 3D pressure and saturation field distribution predictions. Our approach involves solving the score function with a mini-batch-based Monte Carlo estimator to generate labeled data. This data is subsequently employed to train a fully connected neural network, enabling it to learn the conditional sample generator within a supervised learning framework. This method enables the rapid generation of a large ensemble of predictions, facilitating comprehensive uncertainty quantification of state variables. Here we applied our method to forecast the dynamic 3D distributions of pressure and saturation fields over a 30-year injection period. The statistical assessment with low root mean square error (RMSE) values demonstrates that our method can accurately predict the spatiotemporal distributions of both pressure and saturation fields. Moreover, the developed conditional generative model shows high computational efficiency by generating 100 ensemble forecasts of 3D state variables in less than 10 min. The consistency between ensemble averages and ground truth values further illustrates the model’s capability to capture state variable dynamics during the CO 2 plume injection process. Notably, the ground truth values fall within the ensemble forecasts, indicating that our uncertainty quantification effectively captures variability and potential noise in the observations. Thus, the developed conditional generative model proves to be a more efficient, accurate, and practical tool for GCS applications, facilitating timely risk analysis and informed decision-making.

58 GEOSCIENCES↗

An Interactive Spectral Analysis Tool for Chemical Identification and Quantification of Gas-Phase Species in Complex Spectra

A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm –1 ) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.

Thompson, Christopher J.↗

Transport coefficients for magnetic-field evolution in inviscid magnetohydrodynamics

The magnetized resistivity and electrothermal tensors when substituted into the induction equation lead to electrothermal magnetic field generation, resistive magnetic diffusion, and magnetic field advection due to resistivity gradients, temperature gradients and currents. Here, the advection terms driven by temperature gradient and current have cross-field components (perpendicular to both the magnetic field and the driving term) that depend on significantly modified versions of Braginskii’s transport coefficients. The improved fits to Braginskii’s coefficients given by Epperlein and Haines and Ji and Held give physically incorrect results for cross-field advection at small Hall parameters (product of cyclotron frequency and collision time). The errors in Epperlein and Haines’ fits are particularly severe, giving increasing advection velocities below a Hall parameter of one when they should decrease linearly to zero. Epperlein and Haines’ fits can also give erroneous advection terms due to variations in effective atomic number. The only serious error in Braginskii’s fits is an overestimate in advection due to perpendicular resistivity. New fits for the cross-field advection terms are obtained from a direct numerical solution of the Fokker-Planck equation and Ji and Held’s higher order expansion approach that are continuous functions of the effective atomic number.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-BRF-04: Evaluation of Five Commercially-Available Algorithms for Deformable Image Registration

Purpose: Deformable image registration (DIR) is increasingly being used in various clinical applications. Although there are several DIR packages all making successful attempts at modeling complex anatomical changes using even more complex mathematical approximations, they are all subject to various uncertainties. Many studies have attempted to quantify the spatial uncertainty with DIR. This is the first study to compare the uncertainty for interfraction DIR for 5 different commercially-available algorithms. The aim of this study was to benchmark the performance of the most commonlyused DIR algorithms offered through these 5 software packages: Eclipse, MIM, Pinnacle, RaySearch, and Velocity. Methods: A set of 10 virtual H'N phantoms [Pukala et al. MedPhys. 40(11) 2013] with known deformations were used to determine the spatial errors that might be seen when performing DIR. The “ground-truth” deformation vector field (DVF) was compared to the DVF output of the 5 commercially-available algorithms in order to evaluate spatial errors for six regions of interest (ROIs): brainstem, cord, mandible, left parotid, right parotid, and the external body contour. Results: We found that each software package had varying uncertainties with the various ROIs, but were generally all comparable to one another – with mean spatial errors for each algorithm below 3.5 mm for each ROI (averaged across all phantoms). We also found that no single algorithm was the clear winner over the other 4 algorithms. However, at times, we found huge maximum errors in our results (e.g. phantom #9 maximum errors: right parotid = 22.9 mm, external contour = 30.5mm) with the varying DIR algorithms. Conclusion: Although our evaluation was limited to H'N patients, we show that our methods are a single-assessment analysis tool that could be used by any physicist, within any type of facility, to compare their DIR software before initiating widespread use within their daily radiotherapy practice.

60 APPLIED LIFE SCIENCES↗

SU-E-T-73: A Robust Proton Beam Therapy Technique for High-Risk Prostate Cancer Whole Pelvis Irradiation: Bilateral Opposed Single Field Uniform Dose (SFUD) Plan with Lateral Penumbra Gradient Matching

Purpose: To develop a clinical feasible and robust proton therapy technique to spare bowel, bladder and rectum for high-risk prostate cancer patients Methods: The study includes 3 high-risk prostate cancer cases treated with bilateral opposed SFUD with lateral penumbra gradient matching technique prescribed to 5400cGyE in 30 fx in our institution. To treat whole pelvic lymph node chain, the complicated ‘H’ shape, using SFUD technique, we divided the target into two sub-targets (LLAT beam treating ‘90 degree T-shape’ and RLAT beam treating ‘: shape’) in Plan A and use lateral penumbra gradient matching at patient’s left side. Vice verse in Plan B. Each plan deliver half of the prescription dose. Beam-specific PTVs were created to take range uncertainty and setup error into account. For daily treatment, patient received four fields from both plan A and B per day. Robustness evaluation were performed in the worst case scenario with 3.5% range uncertainty and 1, 2, 3mm overlap or gap between LLAT and RLAT field matching in Raystation 4.0. All of cases also have a Tomotherapy backup plan approved by physician as a dosimetric comparison. Results: The total treatment time take 15–20mins including IGRT and four fields delivery on ProteusONE, a compact size PBS proton system, compared to 25–30min in traditional Tomotherapy. Robustness analysis shows that this plan technique is insensitive to the range uncertainties. With the lateral gradient matching, 1, 2, 3mm overlap renders only 2.5%, 5.5% and 8% hot or cool spot in the junction areas. Dosimetric comparisons with Tomotherapy show a significant dose reduction in bladder D50%(14.7±9.3Gy), D35%(7.3±5.8Gy); small bowel and rectum average dose(19.6±7.5Gy and 14.5±6.3Gy respectively). Conclusion: The bilateral opposed(SFUD) plan with lateral penumbra gradient matching has been approved to be a safe, robust and efficient treatment option for whole pelvis high-risk prostate cancer patient which significantly spares the OARs.

60 APPLIED LIFE SCIENCES↗

A Fast Algebraic Multigrid Solver and Accurate Discretization for Highly Anisotropic Heat Flux I: Open Field Lines

We present a novel solver technique for the anisotropic heat flux equation, aimed at the high level of anisotropy seen in magnetic confinement fusion plasmas. Such problems pose two major challenges: (i) discretization accuracy and (ii) efficient implicit linear solvers. We simultaneously address each of these challenges by constructing a new finite element discretization with excellent accuracy properties, tailored to a novel solver approach based on algebraic multigrid (AMG) methods designed for advective operators. We pose the problem in a mixed formulation, introducing the directional temperature gradient as an auxiliary variable. The temperature and auxiliary fields are discretized in a scalar discontinuous Galerkin space with upwinding principles used for discretizations of advection. We demonstrate the proposed discretization’s superior accuracy over other discretizations of anisotropic heat flux, achieving error 1000x smaller for anisotropy ratio of 10 9 , for closed field lines. The block matrix system is reordered and solved in an approach where the two advection operators are inverted using AMG solvers based on approximate ideal restriction, which is particularly efficient for upwind discontinuous Galerkin discretizations of advection. To ensure that the advection operators are nonsingular, in this paper we restrict ourselves to considering open (acyclic) magnetic field lines for the linear solvers. We demonstrate fast convergence of the proposed iterative solver in highly anisotropic regimes where other diffusion-based AMG methods fail.

97 MATHEMATICS AND COMPUTING↗

Mean Field Games for Stochastic Growth with Relative Utility

This paper considers continuous time stochastic growth-consumption optimization in a mean field game setting. The individual capital stock evolution is determined by a Cobb–Douglas production function, consumption and stochastic depreciation. The individual utility functional combines an own utility and a relative utility with respect to the population. The use of the relative utility reflects human psychology, leading to a natural pattern of mean field interaction. The fixed point equation of the mean field game is derived with the aid of some ordinary differential equations. Due to the relative utility interaction, our performance analysis depends on some ratio based approximation error estimate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physical optics simulations with PHASE for SwissFEL beamlines

PHASE is a software tool for physical optics simulation based on the stationary phase approximation method. The code is under continuous development since about 20 years and has been used for instance for fundamental studies and ray tracing of various beamlines at the Swiss Light Source. Along with the planning for SwissFEL a new hard X-ray free electron laser under construction, new features have been added to permit practical performance predictions including diffraction effects which emerge with the fully coherent source. We present the application of the package on the example of the ARAMIS 1 beamline at SwissFEL. The X-ray pulse calculated with GENESIS and given as an electrical field distribution has been propagated through the beamline to the sample position. We demonstrate the new features of PHASE like the treatment of measured figure errors, apertures and coatings of the mirrors and the application of Fourier optics propagators for free space propagation.

43 PARTICLE ACCELERATORS↗

POD-based constrained sensor placement and field reconstruction from noisy wind measurements: A perturbation study

Sensor placement at the extrema of Proper Orthogonal Decomposition (POD) is efficient and leads to accurate reconstruction of the wind field from a limited number of measure- ments. In this paper we extend this approach of sensor placement and take into account measurement errors and detect possible malfunctioning sensors. We use the 48 hourly spa- tial wind field simulation data sets simulated using the Weather Research an Forecasting (WRF) model applied to the Maine Bay to evaluate the performances of our methods. Specifically, we use an exclusion disk strategy to distribute sensors when the extrema of POD modes are close. It turns out that this strategy can also reduce the error of recon- struction from noise measurements. Also, by a cross-validation technique, we successfully locate the malfunctioning sensors.

54 ENVIRONMENTAL SCIENCES↗

Too big, too small, or just right? A benchmark assessment of density functional theory for predicting the spatial extent of the electron density of small chemical systems

Multipole moments are the first-order responses of the energy to spatial derivatives of the electric field strength. The quality of density functional theory prediction of molecular multipole moments thus characterizes errors in modeling the electron density itself, as well as the performance in describing molecules interacting with external electric fields. However, only the lowest non-zero moment is translationally invariant, making the higher-order moments origin-dependent. Therefore, instead of using the 3 × 3 quadrupole moment matrix, we utilize the translationally invariant 3 × 3 matrix of second cumulants (or spatial variances) of the electron density as the quantity of interest (denoted by K). The principal components of K are the square of the spatial extent of the electron density along each axis. A benchmark dataset of the principal components of K for 100 small molecules at the coupled cluster singles and doubles with perturbative triples at the complete basis set limit is developed, resulting in 213 independent K components. The performance of 47 popular and recent density functionals is assessed against this Var213 dataset. Several functionals, especially double hybrids, and also SCAN and SCAN0 predict reliable second cumulants, although some modern, empirically parameterized functionals yield more disappointing performance. The H, Li, and Be atoms, in particular, are challenging for nearly all methods, indicating that future functional development could benefit from the inclusion of their density information in training or testing protocols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HIGH-PRECISION ASTROMETRY WITH A DIFFRACTIVE PUPIL TELESCOPE

Astrometric detection and mass determination of Earth-mass exoplanets require sub-{mu}as accuracy, which is theoretically possible with an imaging space telescope using field stars as an astrometric reference. The measurement must, however, overcome astrometric distortions, which are much larger than the photon noise limit. To address this issue, we propose to generate faint stellar diffraction spikes using a two-dimensional grid of regularly spaced small dark spots added to the surface of the primary mirror (PM). Accurate astrometric motion of the host star is obtained by comparing the position of the spikes to the background field stars. The spikes do not contribute to scattered light in the central part of the field and therefore allow unperturbed coronagraphic observation of the star's immediate surroundings. Because the diffraction spikes are created on the PM and imaged on the same focal plane detector as the background stars, astrometric distortions affect equally the diffraction spikes and the background stars and are therefore calibrated. We describe the technique, detail how the data collected by the wide-field camera are used to derive astrometric motion, and identify the main sources of astrometric error using numerical simulations and analytical derivations. We find that the 1.4 m diameter telescope, 0.3 deg{sup 2} field we adopt as a baseline design achieves 0.2 {mu}as single measurement astrometric accuracy. The diffractive pupil concept thus enables sub-{mu}as astrometry without relying on the accurate pointing, external metrology, or high-stability hardware required with previously proposed high-precision astrometry concepts.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of extragalactic background light from the far UV to the far ir from deep ground- and space-based galaxy counts

We combine wide and deep galaxy number-count data from the Galaxy And Mass Assembly, COSMOS/G10, Hubble Space Telescope (HST) Early Release Science, HST UVUDF, and various near-, mid-, and far-IR data sets from ESO, Spitzer, and Herschel. The combined data range from the far UV (0.15 μm) to far-IR (500 μm), and in all cases the contribution to the integrated galaxy light (IGL) of successively fainter galaxies converges. Using a simple spline fit, we derive the IGL and the extrapolated IGL in all bands. We argue that undetected low-surface-brightness galaxies and intracluster/group light are modest, and that our extrapolated-IGL measurements are an accurate representation of the extragalactic background light (EBL). Our data agree with most earlier IGL estimates and with direct measurements in the far IR, but disagree strongly with direct estimates in the optical. Close agreement between our results and recent very high-energy experiments (H.E.S.S. and MAGIC) suggests that there may be an additional foreground affecting the direct estimates. The most likely culprit could be the adopted model of zodiacal light. Finally we use a modified version of the two-component model to integrate the EBL and obtain measurements of the cosmic optical background (COB) and cosmic infrared background of 24{sub −4}{sup +4} nW m{sup −2} sr{sup −1} and 26{sub −5}{sup +5} nW m{sup −2} sr{sup −1} respectively (48%:52%). Over the next decade, upcoming space missions such as Euclid and the Wide Field Infrared Space Telescope will have the capacity to reduce the COB error to <1%, at which point comparisons to the very high-energy data could have the potential to provide a direct detection and measurement of the reionization field.

79 ASTRONOMY AND ASTROPHYSICS↗

RF Characterization of an S-I-S’ Multilayer Sample

S-I-S’ multilayers promise to boost the performance of bulk superconductors in terms of maximum field and surface resistance. At HZB, RF-surface resistance measurements were performed with a Quadrupole Resonator (QPR) and an S-I-S’ sample (75 nm NbTiN on 15 nm AlN insulator on bulk Nb) prepared at JLab. Measurements were performed at 414, 845, and 1286 MHz at sample temperatures from 2 K up to well above the transition temperature of NbTiN of ~17.3 K. The Rs exhibits an unexpected temperature dependence: Rather than rising monotonically, as expected from BCS theory, a local maximum is observed. There is a temperature range where Rs decreases with increasing temperature. Such behavior indicates that an additional interaction between the superconducting layers may have to be included in the surface resistance model. Measurements of the baseline Nb sample prior to coating exhibited no such behavior; hence systematic measurement errors can be excluded as the explanation. The maximum field was limited by a hard magnetic quench near 20 mT, close to Hc1 of NbTiN, suggesting that the sample is limited by early flux penetration.

Keckert, S.↗

Calibration of a distributed flood forecasting model with input uncertainty using a Bayesian framework

In the process of calibrating distributed hydrological models, accounting for input uncertainty is important, yet challenging. In this study, we develop a Bayesian model to estimate parameters associated with a geomorphology‐based hydrological model (GBHM). The GBHM model uses geomorphic characteristics to simplify model structure and physically based methods to represent hydrological processes. We divide the observed discharge into low‐ and high‐flow data, and use the first‐order autoregressive model to describe their temporal dependence. We consider relative errors in rainfall as spatially distributed variables and estimate them jointly with the GBHM parameters. The joint posterior probability distribution is explored using Markov chain Monte Carlo methods, which include Metropolis‐Hastings, delay rejection adaptive Metropolis, and Gibbs sampling methods. We evaluate the Bayesian model using both synthetic and field data sets. The synthetic case study demonstrates that the developed method generally is effective in calibrating GBHM parameters and in estimating their associated uncertainty. The calibration ignoring input errors has lower accuracy and lower reliability compared to the calibration that includes estimation of the input errors, especially under model structure uncertainty. The field case study shows that calibration of GBHM parameters under complex field conditions remains a challenge. Although jointly estimating input errors and GBHM parameters improves the continuous ranked probability score and the consistency of the predictive distribution with the observed data, the improvement is incremental. To better calibrate parameters in a distributed model, such as GBHM here, we need to develop a more complex model and incorporate much more information.

54 ENVIRONMENTAL SCIENCES↗

Measurement of Telescope Transmission Using a Collimated Beam Projector

With the increasingly large number of Type Ia supernova being detected by current-generation survey telescopes, and even more expected with the upcoming Rubin Observatory Legacy Survey of Space and Time, the precision of cosmological measurements will become limited by systematic uncertainties in flux calibration rather than statistical noise. One major source of systematic error in determining SNe Ia color evolution (needed for distance estimation) is uncertainty in telescope transmission, both within and between surveys. We introduce here the Collimated Beam Projector (CBP), which is meant to measure a telescope transmission with collimated light. The collimated beam more closely mimics a stellar wave front as compared to flat-field-based instruments, allowing for more precise handling of systematic errors such as those from ghosting and filter angle-of-incidence dependence. As a proof of concept, we present CBP measurements of the StarDICE prototype telescope, achieving a standard (1σ) uncertainty of 3% on average over the full wavelength range measured with a single beam illumination.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-371: Development of a Linac Monte Carlo Model to Calculate Surface Dose

Purpose: To generate and validate a linac Monte Carlo (MC) model for surface dose prediction. Methods: BEAMnrc V4-2.4.0 was used to model 6 and 18 MV photon beams for a commercially available linac. DOSXYZnrc V4-2.4.0 calculated 3D dose distributions in water. Percent depth dose (PDD) and beam profiles were extracted for comparison to measured data. Surface dose and at depths in the buildup region was measured with radiochromic film at 100 cm SSD for 4 × 4 cm{sup 2} and 10 × 10 cm{sup 2} collimator settings for open and MLC collimated fields. For the 6 MV beam, films were placed at depths ranging from 0.015 cm to 2 cm and for 18 MV, 0.015 cm to 3.5 cm in Solid Water™. Films were calibrated for both photon energies at their respective dmax. PDDs and profiles were extracted from the film and compared to the MC data. The MC model was adjusted to match measured PDD and profiles. Results: For the 6 MV beam, the mean error(ME) in PDD between film and MC for open fields was 1.9%, whereas it was 2.4% for MLC. For the 18 MV beam, the ME in PDD for open fields was 2% and was 3.5% for MLC. For the 6 MV beam, the average root mean square(RMS) deviation for the central 80% of the beam profile for open fields was 1.5%, whereas it was 1.6% for MLC. For the 18 MV beam, the maximum RMS for open fields was 3%, and was 3.1% for MLC. Conclusion: The MC model of a linac agreed to within 4% of film measurements for depths ranging from the surface to dmax. Therefore, the MC linac model can predict surface dose for clinical applications. Future work will focus on adjusting the linac MC model to reduce RMS error and improve accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing NWP Model Errors Using Doppler-Lidar Measurements of Recurrent Regional Diurnal Flows: Marine-Air Intrusions into the Columbia-River Basin

Ground-based Doppler-lidar instrumentation provides atmospheric wind data at dramatically improved accuracies and spatial/temporal resolutions. These capabilities have provided new insights into atmospheric flow phenomena, but they also should have a strong role in NWP model improvement. Insight into the nature of model errors can be gained by studying recurrent atmospheric flows, here a regional summertime diurnal sea breeze and subsequent marine-air intrusion into the arid interior of Oregon-Washington, where these winds are an important windenergy resource. These marine intrusions were sampled by three scanning Doppler lidars in the Columbia-River Basin as part of the Second Wind Forecast Improvement Project (WFIP2), using data from summer 2016. Lidar time-height cross sections of wind speed identified eight days when the diurnal-flow cycle, (peak wind speeds at midnight, afternoon minima) was obvious and strong. Eight-day composite time-height cross sections of lidar wind speeds are used to validate those generated by the operational NCEP-HRRR model. HRRR simulated the diurnal wind cycle, but produced errors in the timing of onset and significant errors due to a premature nighttime demise of the intrusion flow, producing low-bias errors of 6 m s-1 . Day-to-day and in the composite, whenever a marine intrusion occurred, HRRR made these same errors. The errors occurred under a range of gradient wind conditions indicating that they resulted from the misrepresentation of physical processes within a limited region around the measurement locations. Because of their generation within a limited geographical area, field-measurement programs can be designed to find and address the sources of these NWP errors.

Banta, Robert M.↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗