Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Economics of internal and external energy storage in solar power plant operation

A simple approach is formulated to investigate the effect of energy storage on the bus-bar electrical energy cost of solar thermal power plants. Economic analysis based on this approach does not require detailed definition of a specific storage system. A wide spectrum of storage system candidates ranging from hot water to superconducting magnets can be studied based on total investment and a rough knowledge of energy in and out efficiencies. Preliminary analysis indicates that internal energy storage (thermal) schemes offer better opportunities for energy cost reduction than external energy storage (nonthermal) schemes for solar applications. Based on data and assumptions used in JPL evaluation studies, differential energy costs due to storage are presented for a 100 MWe solar power plant by varying the energy capacity. The simple approach presented in this paper provides useful insight regarding the operation of energy storage in solar power plant applications, while also indicating a range of design parameters where storage can be cost effective.

Manvi, R.↗

Drug effects on orthostatic intolerance induced by bedrest

Effective and practical preventive procedures for postflight orthostatic intolerance are highly desirable. The current practice of attempts to expand plasma volume by ingestion of salt and fluids before reentry has proven benefits. This study evaluated alternative options using fludrocortisone (F) to expand plasma volume (PV), dextroamphetamine (Dex) to enhance norepinephrine (NE) release, and atropine (A) to reduce the effects of vagal stimulation. Seven subjects with proven post-bedrest orthostatic intolerance returned for a 7-day 6-deg head-down bedrest study. F (0.2 mg) was given at 8:00 AM and 8:00 PM the day before and 8:00 AM the day the subjects got out of bed (2 hours before standing). PV was measured before and 1 hour after the last dose of F. Dex (5 mg) and A (0.8 mg) were then taken orally 1 hour before the stand test. F expanded PV by 16 percent and caused sodium retention. Four of the 7 subjects stood for 1 hour post-bedrest and heart rate, plasma NE and plasma renin responses to standing were greatly enhanced and sustained. Although there was a narrowing of pulse pressure, the ability to overcome orthostatic intolerance with these countermeasures was largely due to vasoconstriction and sustained high heart rate.

Vernikos, J.↗

NASA-UVA Light Aerospace Alloy and Structure Technology Program Supplement: Aluminum-Based Materials for High Speed Aircraft

This is the final report of the study "Aluminum-Based Materials for High Speed Aircraft" which had the objectives (1) to identify the most promising aluminum-based materials with respect to major structural use on the HSCT and to further develop those materials and (2) to assess the materials through detailed trade and evaluation studies with respect to their structural efficiency on the HSCT. The research team consisted of ALCOA, Allied-Signal, Boeing, McDonnell Douglas, Reynolds Metals and the University of Virginia. Four classes of aluminum alloys were investigated: (1) I/M 2XXX containing Li and I/M 2XXX without Li, (2) I/M 6XXX, (3) two P/M 2XXX alloys, and (4) two different aluminum-based metal matrix composites (MMC). The I/M alloys were targeted for a Mach 2.0 aircraft and the P/M and MMC alloys were targeted for a Mach 2.4 aircraft. Design studies were conducted using several different concepts including skin/stiffener (baseline), honeycomb sandwich, integrally stiffened and hybrid adaptations (conventionally stiffened thin-sandwich skins). Alloy development included fundamental studies of coarsening behavior, the effect of stress on nucleation and growth of precipitates, and fracture toughness as a function of temperature were an integral part of this program. The details of all phases of the research are described in this final report.

Starke, E. A., Jr.↗

Deep Space Habitat Primary Structure - A Comparison between Metallic, Inflatable, and Composite Materials

This paper presents a comprehensive trade study comparing metallic, inflatable, and composite primary structure materials for a Mars Transit Habitat module. The study evaluates the impact of these materials on the overall mass, outfitting, and mission complexity of the habitat. The results show that the composite module outperforms the other options in terms of minimum mass, being 33% lighter than the metallic configurations and 41% lighter than the inflatable option. The study highlights the potential of composite habitats for future space missions and emphasizes the need for further development and testing to increase the Technology Readiness Level.

Matthew T. Ziglar↗

SU-E-P-25: Evaluation of Motion in Pancreas SBRT Treatment Deliveries

Purpose: Stereotactic Body Radiation Therapy (SBRT) procedures for pancreatic cancer present a challenge in motion management because the target is directly adjacent to critical structures and the target is subject to significant respiratory motion. Gated treatment is usually planned with a tight (few mm) PTV margin. The positioning and setup relies on on-board-imaging (OBI) of internal fiducials. This study evaluates the corrections for inter- and intra-fractional target motion as evidenced by the OBI. Methods: 20 patients with gated pancreas SBRT treatment were setup with KV imaging guidance before and during each treatment. The couch position was fine-tuned to align with the internal fiducials for each patient. The data for 148 intra- and 111 inter-fractional couch movements were captured and analyzed. Results: The mean ± standard deviation of couch shifts for the initial daily setup is 4.9±4.1 mm for couch vertical, 5.3±4.6 mm for couch longitudinal, and 3.7±4.0 mm for couch lateral. The mean ± standard deviation of intra-treatment adjustments are 1.1±1.6, 2.5±3.8, and 1.1±1.8 mm for couch vertical, longitudinal and lateral. The probability of intra-fractional motion in the three orthogonal directions with magnitude no more than 2 mm, 3 mm and 5 mm is 55%, 68% and 84% respectively. Conclusion: The intra-treatment target motion for pancreas SBRT patients indicates that a PTV margin of 5mm may be necessary.

60 APPLIED LIFE SCIENCES↗

Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating two live-attenuated vaccines against Salmonella enterica serovar Reading in turkeys: reduced tissue colonization and cecal tonsil transcriptome responses

Vaccines that cross-protect across serovars ofSalmonella enterica(Salmonella) would be a beneficial intervention against emerging and persistentSalmonellaisolates of concern for the turkey industry. The 2017–2019 foodborne outbreak ofSalmonella entericaserovar Reading (S. Reading) revealed the need for effective control of this serovar in turkey production. This study evaluated two live-attenuatedSalmonellavaccines, an internally developed cross-protective vaccine and a commercially available vaccine, against an outbreak-associated strain ofS. Reading in turkeys. At 1 day and 3 weeks of age, male turkey poults were either mock-vaccinated with phosphate buffered saline (PBS) or given one of the vaccines by oral gavage (primary and booster) or aerosol spray (primary) then drinking water (booster). At 7 weeks of age, poults were challenged with 10 9 colony forming units (CFU) ofS. Reading; a mock-vaccinated group was mock-challenged with PBS. Colonization of the cecal contents and cecal tonsil was 1.5–3 log 10 CFU/g lower in vaccinated birds than mock-vaccinated birds at 7 and/or 14 days post-inoculation (DPI).Salmonelladissemination to the spleen was significantly reduced by both vaccines. Gene expression of intestinal transporters (such asSCNN1BandSLC10A2) and tight junction proteins was significantly decreased in the turkey cecal tonsil transcriptome at 2 DPI withS. Reading. Vaccination with either vaccine mitigated most cecal tonsil gene expression responses toS. Reading challenge. Therefore, both the internally developed vaccine and commercial vaccine were cross-protective against colonization and dissemination, and both were able to limit transcriptional changes from challenge in intestinal health-related genes in the cecal tonsil, thereby providing vaccination efficacy and impact data againstS. Reading in turkeys.

Veterinary Sciences↗

Evaluation of the international reference ionosphere with the large AE-C and DE2 data bases

Empirical models such as the International Reference Ionosphere (IRI) are synthesized from large data bases. They can be viewed as analytical tools to facilitate accessing information stored in the data banks. However, in establishing the models, one has to apply smoothing and averaging procedures that in effect reduce the original information content. This study evaluates the agreement between the data base and the model at two opposite extremes of time resolution. Electron densities and temperatures in the altitude range of 300 to 400 km predicted by the IRI and measured by the AE-C and DE 2 satellites on the level of individual orbits as well as on the level of mission averages are compared. Whereas the averages show excellent agreement, the comparison for individual measurements indicates the limitations of empirical models.

Bilitza, D.↗

Using Visual Systems Mapping to Improve Transparency and Comparability of Life Cycle Assessment Baseline Scenarios

Visual systems mapping is a systems engineering approach used to represent complex processes and interactions. This study evaluates its application for documenting assumptions in life cycle assessment (LCA) baseline scenarios. In LCA, the baseline or reference case represents the business as usual system against which changes in impacts (e.g., emissions) are assessed. These baseline assumptions are particularly influential in biomass LCAs, yet they often vary across studies due to regional context, system boundaries, and simplifying assumptions that are not consistently or transparently documented. As a result, key feedbacks, omitted processes, and boundary choices may remain unclear, limiting comparability across studies and weakening their usefulness for decision-making. This study examines whether visual systems mapping can improve the transparency and comparability of biomass LCA baseline scenarios. A case study of five published biomass-related LCAs were reviewed, and their baseline scenarios were translated into visual system maps to identify included processes, omitted components, and underlying assumptions. The analysis demonstrates that visual systems mapping can make baseline assumptions more explicit, highlight excluded dynamics, and improve documentation of system boundaries. Based on these findings, the study recommends the use of visual systems mapping alongside open data repositories and reproducible workflows to support greater transparency, reproducibility, and comparability in LCAs. These improvements can strengthen the role of LCAs in informing decisions related to sustainable biomass systems.

Davis, Maggie [ORNL] (ORCID:0000000181319328)↗

Accuracy of self‐reported weight, height and body mass index among older people in Japan

Aim Weight and height are usually self‐reported in population‐based epidemiological surveys. While the accuracy of self‐reports has been extensively studied in younger populations, less is known in older populations. We investigated the accuracy of self‐reported weight, height and body mass (BMI) in an older cohort in Japan, where overweight/obesity and underweight coexist. Methods We used data from older Japanese adults (≥65 years) participating in the Japan Gerontological Evaluation Study in 2016 to 2017 (7357 men and 9271 women). Self‐report data were linked to objective data obtained from clinical examinations. Results The mean ± standard deviation (SD) age was 74.5 ± 5.8 years, mean ± SD weight, height and BMI were 55.7 ± 10.1 kg, 156.0 ± 8.9 cm and 22.8 ± 3.1, respectively. Results showed high intraclass correlation coefficients for self‐reported and measured values (0.97 for weight; 0.96 for height). While weight/height were overestimated among men (weight by 0.096 kg; height by 0.27 cm) and women (weight by 0.18 kg; height by 0.27 cm), BMI tended to be slightly underestimated (−0.034 kg/m 2 for men; −0.037 kg/m 2 for women). However, the absolute differences between self‐reported and measured values were not negligible; people had a higher risk for both under‐ and overestimation of their BMI category with increasing age. Lower education predicted BMI overestimation, whereas lower income predicted BMI underestimation. Conclusions Overall accuracy of self‐reported body habitus was higher in this cohort of older Japanese compared with previous reports. Nevertheless, misclassification of BMI due to the misreporting of their weight/height was more common among the oldest‐old, as well as those with lower education and income. Geriatr Gerontol Int 2020; 20: 803–810 .

Yazawa, Aki↗

2018 Benefits Study of Emergency IEA Oil Stocks: Final CRADA Report

This CRADA work was performed with the International Energy Agency (IEA) by Oak Ridge National Laboratory (ORNL) to support ongoing IEA, and U.S. DOE, discussions on future oil market challenges by IEA member countries. ORNL completed an update of a 2012 study for the IEA that accounts for changes in oil market and global economic conditions since 2013. The ORNL study evaluates the collective benefits of IEA emergency oil stocks, counting benefits to all countries, not just IEA, that are net oil importers. The IEA provided oil market data and projections, provided recommendations on parameter values and key case assumptions, in coordination with IEA member countries and coordinated the ORNL study with a parallel study on stockholding costs by an IEA subcontractor. IEA also combined the results of the ORNL benefits study and the IEA-funded cost study in a summary report by IEA, Insights Series 2018 - Costs and Benefits of Emergency Stockholding.

02 PETROLEUM↗

Effects of pH on deposition rate of supersaturated silicic acid around geological disposal system - 15245

For the migration assessment of radionuclides around geological repository, it is important to estimate the dynamic behavior of silicic acid under a high alkalinity condition due to the cementitious materials for the construction of the repository. This study examined the pH dependencies of the deposition behavior of supersaturated silicic acid in the co-presence of solid phase. The parameters for the deposition experiments were as follow: the pH was set to 8, 9 and 10, the initial saturated concentration was set to 2-8 mM, the amount of amorphous silica (350 m{sup 2}/g) as solid phase was set to 0.1-1.0 g. The experimental results showed that the initial supersaturated concentrations strongly affected the formation of colloidal silicic acid, increasing the deposition amount of silicic acid and decreasing the soluble silicic acid with time. In other words, the polymerization and the deposition of silicic acid simultaneously arose in these experiments. Furthermore, this study evaluated the apparent deposition rates of silicic acid by assuming the first-order reaction equation considering the specific surface area. As a result, the deposition rate constants, k, were in a narrow range of 10{sup -11} to 10{sup -10} m/s under all experimental conditions in this study. This means that the deposition rate constants do not depend both on pH-value (in the range from 8 to 10) and the initial concentration of supersaturated silicic acid. That is, the estimated deposition rate constants are useful in estimation of the deposition behavior of supersaturated silicic acid, such as the clogging in fractures (flow-paths) around the repository, even if the pH-value of groundwater gradually or dramatically changes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Historical evaluation and future projections of compound heatwave and drought extremes over the conterminous United States in CMIP6 *

Abstract Independently, both droughts and heatwaves can induce severe impacts on human and natural systems. However, when these two climate extremes occur concurrently in a given region, their compound impacts are often more pronounced. With the improvement in both the spatiotemporal resolution and representation of complex climate processes in the global climate models (GCMs), they are increasingly used to study future changes in these extremes and associated regional impacts. However, GCM selection for such impact assessments is generally based on historical performance and/or future mean changes, without considering individual or compound extremes. In contrast, this study evaluates historical performance and projected changes in heatwaves, droughts, and compound heatwave-droughts using an ensemble of GCMs from the latest Phase 6 of Coupled Models Intercomparison Project at a regional scale across the conterminous United States. Additionally, we explore the inter-model differences in the projected changes that are associated with various characteristics of extremes and the choice of drought indices. Our analysis reveals considerable variation among the GCMs, as well as substantial differences in the projected changes based on the choice of drought indices and region of interest. For example, the projected increases in both the frequency and intensity of drought and associated compound extreme days, based on the standardized precipitation evapotranspiration index far exceed those derived from the standard precipitation index. Further, the largest changes in the frequency of compound extremes are projected over the Southwest, South Central, and parts of the Southeast while the smallest changes are projected over the Northeast. Overall, this study provides important insights for the interpretation and selection of GCMs for future assessment studies that are crucial for the development of regional adaptation strategies in the face of climate change.

54 ENVIRONMENTAL SCIENCES↗

Automated Plasma Spray (APS) process feasibility study

An automated plasma spray (APS) process was developed to apply two layer (NiCrAlY and ZrO2-12Y2O3) thermal barrier coatings to aircraft and stationary gas turbine engine blade airfoils. The APS process hardware consists of four subsystems: a mechanical positioning subsystem incorporating two interlaced six degree of freedom assemblies (one for coating deposition and one for coating thickness monitoring); a noncoherent optical metrology subsystem (for in process gaging of the coating thickness buildup at specified points on the specimen); a microprocessor based adaptive system controller (to achieve the desired overall thickness profile on the specimen); and commerical plasma spray equipment. Over fifty JT9D first stage aircraft turbine blade specimens, ten W501B utility turbine blade specimens and dozens of cylindrical specimens were coated with the APS process in preliminary checkout and evaluation studies. The best of the preliminary turbine blade specimens achieved an overall coating thickness uniformity of 53 micrometers (2.1 mils), much better than is achievable manually. Comparative evaluations of coating thickness uniformity for manually sprayed and APS coated specimens were performed. One of the preliminary turbine blade evaluation specimens was subjected to a torch test and metallographic evaluation. Some cylindrical specimens coated with the APS process survived up to 2000 cycles in subsequent burner rig testing.

Fetheroff, C. W.↗

Development and evaluation of virtual refrigerant mass flow sensors for fault detection and diagnostics

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressor that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor is not delivering the expected flow due to a leaky suction or discharge valve or other internal fault, the energy-balance or EEV model can provide accurate flow estimates. In this paper, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics.

Kim, Woohyun↗