At least 649 records · Page 36

Feasibility study for mega-electron-volt electron beam tomography

Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Momentum spectrometer for electron-electron coincidence studies on superconductors

We present a new experimental setup to study electron-electron coincidences from superconducting surfaces. In our approach, electrons emitted from a surface are projected onto a time- and position-sensitive microchannel plate detector with delayline position readout. Electrons that are emitted within 2 {pi} solid angle with respect to the surface are detected in coincidence. The detector used is a hexagonal delayline detector with enhanced multiple hit capabilities. It is read out with a Flash analog-to-digital converter. The three-dimensional momentum vector is obtained for each electron. The intrinsic dead time of the detector has been greatly reduced by implementing a new algorithm for pulse analysis. The sample holder has been matched to fit the spectrometer while being capable of cooling down the sample to 4.5 K during the measurement and heating it up to 420 K for the cleaning procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of momentum transfer in the quenching of the Gamow-Teller strength

A recent analysis of (p,n) and (n,p) reaction data from {sup 90}Zr was performed recently, where a significant amount of Gamow-Teller strength was found above the resonance, an energy region previously unreachable by experimental setups. The extracted strengths in the {beta}{sub -} and the {beta}{sub +} channel indicate that approximately 10% of the total strength necessary to satisfy the model independent Ikeda sum rule is missing. One possible source of this discrepancy is the treatment of the isovector spin monopole (IVSM) mode of excitation which has been found to occurr at high excitation energies. Employing the relativistic Hartree-Bogoliubov (RHB) model and the protonneutron relativistic quasiparticle random phase approximation (pn-RQRPA) to calculate the nuclear response, we explore the contribution of the IVSM mode to the total L= 0 strength and apply our results to the available data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integration of a broad beam ion source with a high-temperature x-ray diffraction vacuum chamber

Here, the integration of a low energy, linearly variable ion beam current density, mechanically in situ adjustable broad beam ion source with a high-temperature x-ray diffraction (XRD) vacuum chamber is reported. This allows in situ XRD investigation of phase formation and evolution processes induced by low energy ion implantation. Special care has been taken to an independent adjustment of the ion beam for geometrical directing towards the substrate, a 15 mm small ion source exit aperture to avoid a secondary sputter process of the chamber walls, linearly variable ion current density by using a pulse length modulation (PLM) for the accelerating voltages without changing the ion beam density profile, nearly homogeneous ion beam distribution over the x-ray footprint, together with easily replaceable Kapton{sup Registered-Sign} windows for x-rays entry and exit. By combining a position sensitive x-ray detector with this PLM-modulated ion beam, a fast and efficient time resolved investigation of low energy implantation processes is obtained in a compact experimental setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

p process measurements with SuN

The astrophysical p process is considered the main nucleosynthesis mechanism for the creation of the p nuclei. The accurate description of this process still suffers from large uncertainties both in the astrophysical environment and the nuclear physics input. In the latter case, nuclear reaction sensitivity studies have identified a group of reactions that have a significant contribution to the final p-nuclei abundance distribution. The cross sections of such 'important' reactions need to be measured experimentally and for this reason there is a major experimental effort to provide experimental data for the relevant astrophysical energies. In the present work, we introduce a new experimental setup - the SuN detector - that was developed at the National Superconducting Cyclotron Laboratory for measurements of capture reactions of astrophysical interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planned waveguide electric field breakdown studies

This paper presents an experimental setup for X-band rf breakdown studies. The setup is composed of a section of WR90 waveguide with a tapered pin located at the middle of the waveguide E-plane. Another pin is used to rf match the waveguide so it operates in a travelling wave mode. By adjusting the penetration depth of the tapered pin, different surface electric field enhancements can be obtained. The setup will be used to study the rf breakdown rate dependence on power flow in the waveguide for a constant maximum surface electric field on the pin. Two groups of pins have been designed. The Q of one group is different and very low. The other has a similar Q. With the test of the two groups of pins, we should be able to discern how the net power flow and Q affect the breakdown. Furthermore, we will apply an electron beam treatment to the pins to study its effect on breakdown. Overall, these experiments should be very helpful in understanding rf breakdown phenomena and could significantly benefit the design of high gradient accelerator structures.

43 PARTICLE ACCELERATORS↗

SIM-RIBRAS: A Monte-Carlo simulation package for RIBRAS system

SIM-RIBRAS is a Root-based Monte-Carlo simulation tool designed to help RIBRAS users on experience planning and experimental setup enhancing and caracterization. It is divided into two main programs: CineRIBRAS, aiming beam kinematics, and SolFocus, aiming beam optics. SIM-RIBRAS replaces other methods and programs used in the past, providing more complete and accurate results and requiring much less manual labour. Moreover, the user can easily make modifications in the codes, adequating it for specific requirements of an experiment.

43 PARTICLE ACCELERATORS↗

Versatile plug flow catalytic cell for in situ transmission/fluorescence x-ray absorption fine structure measurements

A novel flow-through catalytic cell has been developed for in situ x-ray absorption spectroscopy (XAS) experiments on heterogeneous catalysts under working conditions and in the presence of a liquid and a gas phase. The apparatus allows to carry out XAS measurements in both the transmission and fluorescence modes, at moderate temperature (from RT to 50-80 Degree-Sign C) and low-medium gas pressure (up to 7-8 bars). The materials employed are compatible with several chemicals such as those involved in the direct synthesis of hydrogen peroxide (O{sub 2}, H{sub 2}, H{sub 2}O{sub 2}, methanol). The versatile design of the cell allows to fit it to different experimental setups in synchrotron radiation beamlines. It was used successfully for the first time to test nanostructured Pd catalysts during the direct synthesis of hydrogen peroxide (H{sub 2}O{sub 2}) in methanol solution from dihydrogen and dioxygen.

36 MATERIALS SCIENCE↗

Monte Carlo simulation for the transport beamline

In the framework of the ELIMED project, Monte Carlo (MC) simulations are widely used to study the physical transport of charged particles generated by laser-target interactions and to preliminarily evaluate fluence and dose distributions. An energy selection system and the experimental setup for the TARANIS laser facility in Belfast (UK) have been already simulated with the GEANT4 (GEometry ANd Tracking) MC toolkit. Preliminary results are reported here. Future developments are planned to implement a MC based 3D treatment planning in order to optimize shots number and dose delivery.

43 PARTICLE ACCELERATORS↗

BiPo: A dedicated radiopurity detector for the SuperNEMO experiment

New generation experiments in Astroparticle Physics need to operate in really restrictive background conditions, which implies the use of high radiopure materials for the experimental setup construction. For this reason the screening of the materials with enough sensitivity has become a challenge that sometimes cannot be afforded with standard techniques like Germanium detector spectroscopy. BiPo is a dedicated detector, that operates in the Canfranc Underground Laboratory, designed to measure the radiopurity, mainly of the ββ sources of the SuperNEMO experiment, by the detection of BiPo events. It is composed of two modules with 40 optical lines each one, registering the energy and the time of the emitted particles. The well known features of the BiPo events (delayed coincidence between an electron and an alpha particle) facilitate the discrimination of other background events that could entangle the expected signal. In addition, the geometry of the detector, with an active area of around 3.6 m{sup 2}, has been optimized to reach the necessary sensitivity levels for the SuperNEMO source foils in the shortest time possible. Preliminary results of background measurements and calibrations taken since summer 2012 shows that the required sensitivity for the measurements of the source foils could be reached in few months. Routine measurements of samples are already started being an important point for the SuperNEMO source foils construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High sensitivity detectors for measurement of diffusion, emanation and low activity of radon

Today's underground experiments require ultra-low background conditions. One of the most important source of background is radon. It is necessary to suppress it and consequently to detect very low radon concentration. In the frame of SuperNEMO collaboration experimental setups for measurement of low radon activity, radon diffusion through shielding foils and radon emanation from construction materials have been constructed in IEAP CTU in Prague and the obtained results are presented. The application of Timepix device in radon detection is briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The influence of the spectral emissivity of flat-plate calibrators on the calibration of IR thermometers

Flat Calibrators (FC) are an option for calibration of infrared thermometers (IT) with a fixed large target. FCs are neither blackbodies, nor gray-bodies; their spectral emissivity is lower than one and depends on wavelength. Nevertheless they are used as gray-bodies with a nominal emissivity value. FCs can be calibrated radiometrically using as reference a calibrated IR thermometer (RT). If an FC will be used to calibrate ITs that work in the same spectral range as the RT then its calibration is straightforward: the actual FC spectral emissivity is not required. This result is valid for any given fixed emissivity assessed to the FC. On the other hand, when the RT working spectral range does not match with that of the ITs to be calibrated with the FC then it is required to know the FC spectral emissivity as part of the calibration process. For this purpose, at CENAM, we developed an experimental setup to measure spectral emissivity in the infrared spectral range, based on a Fourier transform infrared spectrometer. Not all laboratories have emissivity measurement capability in the appropriate wavelength and temperature ranges to obtain the spectral emissivity. Thus, we present an estimation of the error introduced when the spectral range of the RT used to calibrate an FC and the spectral ranges of the ITs to be calibrated with the FC do not match. Some examples are developed for the cases when RT and IT spectral ranges are [8,13] μm and [8,14] μm respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Double momentum spectrometer for ion-electron vector correlations in dissociative photoionization

We have developed a new momentum spectrometer dedicated to momentum vector correlations in the context of deep core photoionization of atomic and molecular species in the gas phase. In this article, we describe the design and operation of the experimental setup. The capabilities of the apparatus are illustrated with a set of measurements done on the sulphur core 1s photoionization of gas-phase CS{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Status and prospects of R{sub n} measurements at Mainz

Parity-violating electron scattering is particularly sensitive to the neutron density. The recent PREX experiment at the Jefferson Laboratory (JLab) has demonstrated the feasibility of this method meanwhile outlining its major experimental challenges. On the other side intermediate energy photons are an ideal probe for studying the properties of strongly interacting matter from the nuclear scale down to the sub-nuclear components of the nucleus. Among others, coherent pion photoproduction on nuclei is an attractive approach to obtain information on the existence and nature of neutron skins in nuclei. The simultaneous combination of different techniques allows a systematic determination of the neutron skin of nuclei across the periodic table thus benchmarking modern calculations. Recently a systematic investigation of the latter method has been exploited at the MAMI accelerator. With the future accelerator MESA, the same experimental setup as in the measurement of the weak mixing angle will allow for a measurement of the parity violating asymmetry for longitudinally polarized electrons scattered on heavy nuclei with an accuracy of order 1% such that the neutron radius can be determined with precision competitive with the future PREX measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Note: Near infrared spectral and transient measurements of PbS quantum dots luminescence

We describe an experimental setup for the characterization of luminescence from nanostructures. The setup is intended for steady-state and time-resolved luminescence measurements in the near-infrared region. The setup allows us to study spectral luminescence properties in the spectral range of 0.8–2.0 μm with high spectral resolution and kinetic luminescence properties between 0.8 and 1.7 μm with a time resolution of 3 ns. The capabilities of the system are illustrated by taking luminescence measurements from PbS quantum dots. We established the size dependencies of the optical properties of the PbS quantum dots over a wide spectral range. Finally, the energy transfer process was studied with a high temporal and spectral resolution.

36 MATERIALS SCIENCE↗

A platform for x-ray absorption fine structure study of dynamically compressed materials above 1 Mbar [A platform for XAFS study of dynamically compressed materials above 1 Mbar]

Here, a platform consisting of a multi-shock drive and an implosion backlighter has been developed for x-ray absorption fine structure (XAFS) measurements on materials compressed to multi-Mbar pressures. The experimental setup, target design, and backlighter characteristics are presented. Extended XAFS (EXAFS) measurements for various materials have been demonstrated. A quintuple-crystal design is described to enhance the efficiency of the x-ray spectrometer, enabling observation of very weak EXAFS signals in a single shot.

47 OTHER INSTRUMENTATION↗

Numerical and experimental evaluation of laser forming process for the shape correction in ultra high strength steels

In this paper, laser forming characteristics in ultra high strength steel with ultimate strength of 1200MPa are investigated numerically and experimentally. FE simulation is conducted to identify the response related to deformation and characterize the effect of laser power, beam diameter and scanning speed with respect to the bending angle for a square sheet part. The thermo-mechanical behaviors during the straight-line heating process are presented in terms of temperature, stress and strain. An experimental setup including a fiber laser with maximum mean power of 3.0 KW is used in the experiments. From the results in this work, it would be easily adjustment the laser power and the scanning speed by controlling the line energy for a bending operation of CP1180 steel sheets.

36 MATERIALS SCIENCE↗

A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum

We present the design and performance of an ultra-high vacuum (UHV) low temperature scanning probe microscope employing the nitrogen-vacancy color center in diamond as an ultrasensitive magnetic field sensor. Using this center as an atomic-size scanning probe has enabled imaging of nanoscale magnetic fields and single spins under ambient conditions. In this article we describe an experimental setup to operate this sensor in a cryogenic UHV environment. This will extend the applicability to a variety of molecular systems due to the enhanced target spin lifetimes at low temperature and the controlled sample preparation under UHV conditions. The instrument combines a tuning-fork based atomic force microscope (AFM) with a high numeric aperture confocal microscope and the facilities for application of radio-frequency (RF) fields for spin manipulation. We verify a sample temperature of <50 K even for strong laser and RF excitation and demonstrate magnetic resonance imaging with a magnetic AFM tip.

36 MATERIALS SCIENCE↗