A Report on Superfluid Helium Flow Through Porous Plugs for Space Science Applications

As a background for the study of the nature of superfluid helium flow through porous plugs for other space science uses, preliminary tests on various plugs of a given material, diameter, height, and filtration grade have been performed. Two characteristics of the plugs, pore size and number of channels, have been determined by the bubble test and warm flow test of helium gas through the plugs, respectively. Tests on the flow of He II through the plugs have also been performed. An obvious feature of the results of these tests is that for isothermal measurements of pressure versus mass flow rate below approximately 2.10 K, the flow is separated into two different regimes, indicative of the occurrence of a critical phenomenon.

Mason, F. C.↗

Generating high Reynolds-number flows.

Present test facilities are seriously limited regarding investigations involving high Reynolds numbers due to financial considerations. Quasi-steady testing facilities offer a practical immediate solution to the problem of high-Re testing. A familiar example is the blowdown wind tunnel, but even more flexibility and economy may be provided by using shock-tube devices. The Ludwieg tube is the shock-tube device most often proposed as a means of generating high-Re flows. Two-stage nozzles may be used with a Ludwieg tube. Quasi-steady facilities will be useful only if the available test time exceeds that required to establish steady flow.

Russell, D. A.↗

Short-duration, transonic flow, variable-porosity test section

Short-duration test facility obtains extremely high Reynolds number flows in subsonic, transonic, and supersonic speed ranges, and aids in solving Reynolds number-dependent aerodynamic and thermodynamic problems in design and testing of large, high speed vehicles. The modified blowdown wind tunnel avoids data confusion and aerodynamic noise.

Davis, J. W.↗

Operational evaluation of a proppeller test stand in the quiet flow facility at Langley Research Center

Operational proof tests of a propeller test stand (PTS) in a quiet flow facility (QFF) are presented. The PTS is an experimental test bed for acoustic propeller research in the quiet flow environment of the QFF. These proof tests validate thrust and torque predictions, examine the repeatability of measurements on the PTS, and determine the effect of applying artificial roughness to the propeller blades. Since a thrusting propeller causes an open jet to contract, the potential flow core was surveyed to examine the magnitude of the contraction. These measurements are compared with predicted values. The predictions are used to determine operational limitations for testing a given propeller design in the QFF.

Block, P. J. W.↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The state of the art of conventional flow visualization techniques for wind tunnel testing

Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.

Settles, G. S.↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An experimental investigation of end treatments for nonreturn wind tunnels

The results of a series of flow quality and performance tests on several inlet and exit configurations for nonreturn wind tunnels are presented. Test section flow angularities, local dynamic pressure variations, and total-pressure-loss variations are presented as functions of wind-to-test-section dynamic pressure ratio. The results show that a nonreturn wind tunnel should have end treatments with three characteristics: (1) a vertical exit system, (2) a horizontal inlet system, and (3) an area of protected enclosure at the inlet. Inlet and exhaust treatments were developed that produced good aerodynamic flow qualities with low power penalties.

Eckert, W. T.↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

On Characterization of Flow Disturbances in Arc-Jet Testing

This paper reports computational simulations and analysis of flow characterization tests in high enthalpy arc-jet facilities at NASA Ames Research Center. Flow disturbances and their characterization are presented through case studies, and their implications for testing are discussed. The case studies include free-jet test configurations from three different arc heaters and nozzles: the 60-MW IHF 30-inch conical nozzle, the 10-MW TP3 15-inch conical nozzle, and the 20-MW AHF 12-inch conical nozzle. For all cases, test articles are placed in the jet exiting the conical nozzle, and the existence of a flow disturbance is confirmed through flow survey data using pitot pressure and heat flux probes and accompanying analysis. The paper focuses on cases where the effects of the disturbances on test article surface quantities are important. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzles and test box, including the models tested. Comparisons of computations with the experimental measurements are presented. The computations that reproduce the probe sweep data approximately are essential to interpret the arc-jet test data accurately, while providing insights into several observed calorimeter anomalies caused by flow disturbances.

Arc-jet testing↗

On Characterization of Flow Disturbances in Arc-Jet Testing

This paper reports computational simulations and analysis of flow characterization tests in high enthalpy arc-jet facilities at NASA Ames Research Center. Flow disturbances and their characterization are presented through case studies, and their implications for testing are discussed. The case studies include free-jet test configurations from three different arc heaters and nozzles: the 60-MW IHF 30-inch conical nozzle, the 10-MW TP3 15-inch conical nozzle, and the 20-MW AHF 12-inch conical nozzle. For all cases, test articles are placed in the jet exiting the conical nozzle, and the existence of a flow disturbance is confirmed through flow survey data using pitot pressure and heat flux probes and accompanying analysis. The paper focuses on cases where the effects of the disturbances on test article surface quantities are important. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzles and test box, including the models tested. Comparisons of computations with the experimental measurements are presented. The computations that reproduce the probe sweep data approximately are essential to interpret the arc-jet test data accurately, while providing insights into several observed calorimeter anomalies caused by flow disturbances.

Arc-jet testing↗

Laminar flow control leading edge glove flight test article development

A laminar flow control (LFC) flight test article was designed and fabricated to fit into the right leading edge of a JetStar aircraft. The article was designed to attach to the front spar and fill in approx. 70 inches of the leading edge that are normally occupied by the large slipper fuel tank. The outer contour of the test article was constrained to align with an external fairing aft of the front spar which provided a surface pressure distribution over the test region representative of an LFC airfoil. LFC is achieved by applying suction through a finely perforated surface, which removes a small fraction of the boundary layer. The LFC test article has a retractable high lift shield to protect the laminar surface from contamination by airborne debris during takeoff and low altitude operation. The shield is designed to intercept insects and other particles that could otherwise impact the leading edge. Because the shield will intercept freezing rain and ice, a oozing glycol ice protection system is installed on the shield leading edge. In addition to the shield, a liquid freezing point depressant can be sprayed on the back of the shield.

Pearce, W. E.↗

Additive Manufactured Ultra-Fine Lattice Structures for Propulsion Catalysts

Traditional mono-propulsion catalysts consist of coated ceramic or graphite foams that possess anisotropic mechanical and fluid properties limiting design, cost, availability, and operational use. Ultra-fine lattice structures are repeating unit cells with ligament thickness as small as 100 μm produced via Additive manufacture (AM). These lattice structures have the potential to replace coated foams used in a mono-propellant system catalysts. AM ultrafine lattice structures are designed to mimic the operational intent of coated foams but with improved design flexibility, compressive strength, and flow behavior printed from into a single part directly from the preferred platinum metal alloy. The investigation objective was to conduct feasibility studies of AM ultra-fine lattice structures capable of replacing coated foams with superior functionality. NASA MSFC identified desired lattice characteristics and created designs while EOS developed optimized laser powder bed fusion AM parameters to manufacture Ti6Al4V and tungsten specimens. Optimized designs, computational tools, AM parameters, and post-process methods were developed. Specimens underwent x-ray microfocus CT, metallographic inspection, compression testing, and flow testing. Results demonstrate that AM ultra-fine lattices improved geometric and performance repeatability with the potential for significantly increased availability while decreasing cost and lead time.

Omar R Mireles↗

Additive Manufacture of Ultra-Fine Lattice Structures of Green Propulsion Catalysts

Traditional mono-propulsion catalysts consist of coated ceramic or graphite foams that possess anisotropic mechanical and fluid properties limiting design, cost, availability, and operational use. Ultra-fine lattice structures are repeating unit cells with ligament thickness as small as 100 μm produced via Additive manufacture (AM). These lattice structures have the potential to replace coated foams used in a mono-propellant system catalysts. AM ultrafine lattice structures are designed to mimic the operational intent of coated foams but with improved design flexibility, compressive strength, and flow behavior printed from into a single part directly from the preferred platinum metal alloy. The investigation objective was to conduct feasibility studies of AM ultra-fine lattice structures capable of replacing coated foams with superior functionality. NASA MSFC identified desired lattice characteristics and created designs while EOS developed optimized laser powder bed fusion AM parameters to manufacture Ti6Al4V and tungsten specimens. Optimized designs, computational tools, AM parameters, and post-process methods were developed. Specimens underwent x-ray microfocus CT, metallographic inspection, compression testing, and flow testing. Results demonstrate that AM ultra-fine lattices improved geometric and performance repeatability with the potential for significantly increased availability while decreasing cost and lead time.

Omar Mireles↗

Additive Manufactured Ultra-Fine Lattice Structures for Propulsion Catalysts

Traditional mono-propulsion catalysts consist of coated ceramic or graphite foams that possess anisotropic mechanical and fluid properties limiting design, cost, availability, and operational use. Ultra-fine lattice structures are repeating unit cells with ligament thickness as small as 100 μm produced via Additive manufacture (AM). These lattice structures have the potential to replace coated foams used in a mono-propellant system catalysts. AM ultra-fine lattice structures are designed to mimic the operational intent of coated foams but with improved design flexibility, compressive strength, and flow behavior printed from into a single part directly from the preferred platinum metal alloy. The investigation objective was to conduct feasibility studies of AM ultra-fine lattice structures capable of replacing coated foams with superior functionality. NASA MSFC identified desired lattice characteristics and created designs while EOS developed optimized laser powder bed fusion AM parameters to manufacture Ti6Al4V and tungsten specimens. Optimized designs, computational tools, AM parameters, and post-process methods were developed. Specimens underwent x-ray micro-focus CT, metallographic inspection, compression testing, and flow testing. Results demonstrate that AM ultra-fine lattices improved geometric and performance repeatability with the potential for significantly increased availability while decreasing cost and lead time.

Omar R Mireles↗

Analysis and Comparison of Surface Roughness Effects on Pressure Data from SLS Wind Tunnel Test

Unsteady flows are becoming a more characterized field of study as advancements in technology is allowing for more high-speed, time-resolved data acquisition. It is important to understand these flows as the shock-wave boundary-layer interactions and separation they are involved with can generate extreme loads caused by high pressure and temperature on the body of a flight vehicle. It is vital to characterize these loads, as they can impede upon the structural integrity of a high-speed system. A common instrument utilized today to characterize pressure distributions caused by unsteady flows are unsteady pressure transducers. Set flush with the surface of a flight vehicle or wind tunnel model, these transducers can provide a pressure distribution, capturing the frequency of unsteady loads that could impinge upon the test article. A couple negative aspects of this instrumentation is that they are expensive, have long lead times, and a pressure distribution can only be determined in one discrete location where the transducer is installed. An optical diagnostic known as unsteady pressure-sensitive paint (uPSP) can help to satisfy these deficiencies. This is a spray paint that can be applied to a surface of a model to provide a global pressure distribution across the whole painted region.2 A complete picture of the fluid dynamic pressures occurring on the surface of a test article can be analyzed, especially in locations where it may have been impossible to install a transducer. Pressure-sensitive paint is also less expensive than traditional pressure transducers, which are, on average, about $2,000 each including the cost of installation.3 Unsteady PSP will not replace unsteady pressure transducers, but the transducers can be used to validate the PSP response to the flow and measure frequencies higher than the frequency response of the paint. One issue that can arise using these tools simultaneously, is that the surface roughness of the uPSP can affect the pressure readings of the transducers. Applying the uPSP to the surface of the model is going to affect the flow in some way as the topography of the model is now different than if it was not painted. One study with steady PSP conducted by Amer, Obara, and Liu at NASA Langley concluded that the PSP surface roughness was minimally intrusive at different test conditions with various lift, drag, etc., however, it was noted that data from some pressure transducers had decreased, likely due to the uneven application of the PSP in the localized region of the transducers.9 Sugioka et. al. tested various formulations of uPSP to study surface roughness effects on a Common Research Model (CRM) in transonic flow. The influence of uPSP on the surface of the model, depending on how it was formulated, was noted to have the possibility of relocating the shock wave present in the flow. This study was conducted to examine and compare transducer data acquired in December 2017 of a 4% scale model of the Space Launch System (SLS) performed at NASA Ames Research Center (ARC) Unitary Plan Wind Tunnel (UPWT). One goal of the test was to demonstrate to the customer the potential of the uPSP system developed at NASA ARC. The effect of uPSP on transducer signals also became an interest in this experiment and is the reason for this data analysis. The results of this study were discussed with the SLS team to help them make decisions regarding the next test on an SLS model with the PSP and Unitary Plan Wind Tunnel teams.

pressure-sensitive paint↗

Space shuttle orbiter reaction control system interactions with the vehicle flow field

Test data on the effect of the interaction between the space shuttle orbiter rear-mounted reaction control system jets and the flow over the vehicle in the atmosphere are analyzed with particular attention to yaw angle effects. Masted tank-plus-orbiter jet interactions resulting from combinations of forward and rear-mounted reaction control jets being fired prior to external tank staging are also documented. The primary correlating parameter used for the mated data is a single-jet momentum ratioed to free-stream momentum. An analytic model for computing reaction control system interactions for all control combinations used for mated vehicle coast is included.

Rausch, J. R.↗

Water tunnel results of leading-edge vortex flap tests on a delta wing vehicle

A water tunnel flow visualization test on leading edge vortex flaps was conducted at the flow visualization facility of the NASA Ames Research Center's Dryden Flight Research Facility. The purpose of the test was to visually examine the vortex structures caused by various leading edge vortex flaps on the delta wing of an F-106 model. The vortex flaps tested were designed analytically and empirically at the NASA Langley Research Center. The three flap designs were designated as full-span gothic flap, full-span untapered flap, and part-span flap. The test was conducted at a Reynolds number of 76,000/m (25,000/ft). This low Reynolds number was used because of the 0.076-m/s (0.25-ft/s) test section flow speed necessary for high quality flow visualization. However, this low Reynolds number may have influenced the results. Of the three vortex flaps tested, the part-span flap produced what appeared to be the strongest vortex structure over the flap area. The full-span gothic flap provided the next best performance.

Delfrate, J. H.↗