Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Remote Detection of Uranium Using Self-Focusing Intense Femtosecond Laser Pulses

Optical measurement techniques can address certain important challenges associated with nuclear safety and security. Detection of uranium over long distances presents one such challenge that is difficult to realize with traditional ionizing radiation detection, but may benefit from the use of techniques based on intense femtosecond laser pulses. When a high-power laser pulse propagates in air, it experiences collapse and confinement into filaments over an extended distance even without external focusing. In our experiments, we varied the initial pulse chirp to optimize the emission signal from the laser-produced uranium plasma at an extended distance. While the ablation efficiency of filaments formed by self-focusing is known to be significantly lower when compared to filaments produced by external focusing, we show that filaments formed by self-focusing can still generate luminous spectroscopic signatures of uranium detectable within seconds over a 10-m range. The intensity of uranium emission varies periodically with laser chirp, which is attributed to the interplay among self-focusing, defocusing, and multi-filament fragmentation along the beam propagation axis. Grouping of multi-filaments incident on target is found to be correlated with the uranium emission intensity. The results show promise towards long-range detection, advancing the diagnostics and analytical capabilities in ultrafast laser-based spectroscopy of high-Z elements.

42 ENGINEERING↗

Star formation in Carina OB1: Observations of a giant molecular cloud associated with the eta Carinae Nebula

A giant molecular cloud associated with the eta Carinae nebula was fully mapped in CO with the Columbia Millimeter-Wave Telescope at Cerro Tololo. The cloud comples has a mass of roughly 700,000 solar mass and extends about 140 pc along the Galactic plane, with the giant Carina HII region situated at one end of the complex. Clear evidence of interaction between the HII region and the molecular cloud is found in the relative motions of the ionized gas, the molecular gas, and the dust; simple energy and momentum considerations suggest that the HII region is responsible for the observed motion of a cloud fragment. The molecular cloud complex appears to be the parent material of the entire Car OB1 Association which, in addition to the young clusters in the Carine nebula, includes the generally older cluster NGC 3325, NGC 3293, and IC 2581. The overall star formation efficiency in the cloud complex is estimated to be approximately 0.02.

Grabelsky, D. A.↗

A silicone column for GC analysis of polar and nonpolar chemicals

The investigation of the Saturnian System is being proposed jointly by NASA and the European Space Agency (ESA). The mission is scheduled for a launch in 1996. The mission provides an opportunity for close observation and exploration of Saturn's atmosphere, the complex Saturnian System of satellites and rings, Titan (Saturn's planet-sized moon), and Saturn's magnetosphere. The mission gives special attention to Titan which is blanketed by a thick, opaque atmosphere. An atmospheric probe will be deposited into the Titan Atmosphere for in situ measurement during a slow, three hour descent to the surface. The results from this analysis may provide the information which is important to the research of chemical evolution, and the origin of life. An analytical system was developed as a part of the Titan Aerosol Gas Experiment (TAGEX), a proposed experiment for the Cassini Mission. This system will use two highly sensitive detectors, the Metastable Ionization Detector (MID) and the Ion Mobility Spectrometer (IMS). Unfortunately, when commercial columns are utilized with these highly sensitive detectors, volatile components continuously bleed from the column and interfere with the detector. In addition, light columns must be able to separate polar and nonpolar organic chemicals within 10-15 minutes under isothermal conditions for the Titan Mission. Therefore, a highly crosslinked silicone polymeric packed column was developed which is able to efficiently separate amines, alcohols, and hydrocarbons with retention times less that 15 minutes at 100 C isothermal condition.

Shen, T. C.↗

Photon-dominated regions around cool stars: The effects of the color temperature of the radiation field

We have investigated the influence of the color temperature of the illuminating radiation field on the chemical and thermal structure of photon-dominated regions (PDRs). We present the results of a study of the photoelectric efficiency of heating by large molecules such as polycyclic aromatic hydrocarbons (PAHs) and very small grains for radiation fields characterized by different effective temperatures. We show that the efficiency for cooler (T(sub eff) approximately = 6000-10,000 K) stars is at most an order of magnitude smaller than that for hotter (T(sub eff) approximately = 20,000-30,000 K) stars. While cooler radiation fields result in less ultraviolet photons capable of heating, the efficiency per absorbed photon is higher, because the grains become less positively charged. We also present detailed calculations of the chemistry and thermal balance for generic PDRs (n(sub 0) approximately = 10(exp 3), G(sub 0) approximately = 10(exp 3)). For cooler radiation fields, the H/H2 and C(+)/C/CO transition layers shift toward the surface of the PDR, because fewer photons are available to photodissociate H2 and CO and to ionize C. The dominant cooling lines are the (C II) 158 micron and the (O I) 63 micron lines for the hotter radiation fields, but cooling by CO becomes dominant for a color temperature of 6000 K or lower. The (C II)/CO and (O I)/CO ratios are found to be very good diagnostics for the color temperature of the radiation field.

Spaans, Marco↗

A Comprehensive Analysis of the Physical Properties of Advanced GaAs/AlGaAs Junctions

Extensive studies have been performed on MQW junctions and structures because of their potential applications as avalanche photodetectors in optical communications and imaging systems. The role of the avalanche photodiode is to provide for the conversion of an optical signal into charge. Knowledge of junction physics, and the various carrier generation/recombination mechanisms, is crucial for effectively optimizing the conversion process and increasing the structure's quantum efficiency. In addition, the recent interest in the use of APDs in imaging systems has necessitated the development of semiconductor junctions with low dark currents and high gains for low light applications. Because of the high frame rate and high pixel density requirements in new imaging applications, it is necessary to provide some front-end gain in the imager to allow operation under reasonable light conditions. Understanding the electron/hole impact ionization process, as well as diffusion and surface leakage effects, is needed to help maintain low dark currents and high gains for such applications. In addition, the APD must be capable of operating with low power, and low noise. Knowledge of the effects of various doping configurations and electric field profiles, as well as the excess noise resulting from the avalanche process, are needed to help maintain low operating bias and minimize the noise output.

Menkara, Hicham M.↗

First lithium experiments in HIDRA and evidence of helium retention during quasi-steady-state stellarator plasma operations

Recent experiments in Hybrid Illinois Device for Research and Applications (HIDRA) have had operational discharges between t discharge = 60 and 1000 s using electron cyclotron resonant heating (ECRH) of the plasma. This means that quasi-steady-state plasma discharges reach conditions to study long-pulse plasma material interactions (PMIs). The newly commissioned HIDRA-Material Analysis Test-stand PMI diagnostic is used to place a drop of lithium onto a heated tungsten surface, transfer the sample in-vacuo and expose it in a helium plasma. Helium is of interest as there is an open question to whether lithium will be able to remove helium ash in real fusion devices. The introduction of the W-Li sample in HIDRA resulted in evaporation of lithium into the helium plasma during a 600 s pulse and caused a reduction of over 90% in neutral pressure during the discharge. It was also observed that the plasma density and temperature increased by over 2.5 times. Using spectroscopy and a helium collisional radiative model, the peak temperature and density of the helium plasma can be monitored during the discharge. During lithium evaporation, as significant lithium ionization occurs, there is a 85% drop in the HIDRA vessel neutral pressure, despite a constant flow rate of He gas. This reduction in neutral pressure is supported by spectroscopy data with corresponding reductions in He I line intensities (587 nm, 667 nm, 706 nm, and 728 nm), as well as those of other impurities. At one point in the discharge a lithium plasma is created, as indicated by an increase in Li + emission and a complete reduction in He + emission, but the electron density jumps from ne = 3 × 10 18 m –3 to over ne = 8 × 10 18 m –3 while the core temperature stays relatively constant between Te = 16 eV and 20 eV. Once lithium has completely evaporated from the sample and the majority of the ionized lithium has diffused from the plasma to the vessel walls, pressure and spectroscopy data paired with He collisional radiative model calculations shows a re-establishment of a helium plasma in a low recycling regime. In this regime, the density drops down to ne = 2 × 10 18 m –3 and the electron temperature increases from T e = 20 eV to over T e = 50 eV indicating an increase in helium heating efficiency. This is also indicated by the He+ emission re-establishing and having a higher intensity. Here, we show the results from the first lithium campaign in HIDRA. In the presence of lithium, and in particular when lithium ions are present, the helium disappears from the plasma via an as of yet unknown complex relationship that needs to be further studied. The most likely explanation is that the lithium ions are distributed around the vessel and able to trap helium to the surface turning HIDRA into a large gettering surface. These results have potential implications on future plasma facing component design using liquid lithium for impurity and recycling control using limiters and divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron-induced fission fragment angular distributions, anisotropy, and linear momentum transfer measured with the NIFFTE fission time projection chamber

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning 235 U, 238 U, and 239Pu and fission fragment angular anisotropy of 235 U and 238 U as a function of neutron energies in the range 130 keV–250 MeV are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Efficiency Plastic Scintillator Detector with Wave-Length Shifting Fiber Readout for the GLAST Large Area Telescope

This paper describes the design and performance studies of the scintillator tile detectors for the Anti-Coincidence Detector (ACD) of the Large Area Telescope (LAT) on the Gamma ray Large Area Space Telescope (GLAST), scheduled for launch in early 2008. The scintillator tile detectors utilize wavelength shifting fibers and have dual photomultiplier tube (PMT) readout. The design requires highly efficient and uniform detection of singly charged relativistic particles over the tile area and must meet all requirements for a launch, as well as operation in a space environment. We present here the design of three basic types of tiles used in the ACD, ranging in size from approx.450 sq cm to approx.2500 sq cm, all 1 cm thick, with different shapes, and with photoelectron yield of approx. 20 photoelectrons per minimum ionizing particle (mip) at normal tile incidence, uniform over the tile area. Some tiles require flexible clear fiber cables up to 1.5 m long to deliver scintillator light to remotely located PMT.

Moiseev, A. A.↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanowell-mediated multidimensional separations combining nanoLC with SLIM IM-MS for rapid, high-peak-capacity proteomic analyses

Mass spectrometry (MS)–based analysis of complex biological samples is essential for biomedical research and clinical diagnostics. The separation prior to MS plays a key role in the overall analysis, with separations having larger peak capacities often leading to more identified species and improved confidence in those identifications. High-resolution ion mobility (IM) separations enabled by Structures for Lossless Ion Manipulation (SLIM) can provide extremely rapid, high-resolution separations and are well suited as a second dimension of separation following nanoscale liquid chromatography (nanoLC). However, existing sample handling approaches for offline coupling of separation modes require microliter-fraction volumes and are thus not well suited for analysis of trace biological samples. We have developed a novel nanowell-mediated fractionation system that enables nanoLC-separated samples to be efficiently preconcentrated and directly infused at nanoelectrospray flow rates for downstream analysis. When coupled with SLIM IM-MS, the platform enables rapid and high-peak-capacity multidimensional separations of small biological samples. In this study, peptides eluting from a 100 nL/min nanoLC separation were fractionated into ~?60 nanowells on a microfluidic glass chip using an in-house–developed robotic system. The dried samples on the chip were individually reconstituted and ionized by nanoelectrospray for SLIM IM-MS analysis. Using model peptides for characterization of the nanowell platform, we found that at least 80% of the peptide components of the fractionated samples were recovered from the nanowells, providing up to ~tenfold preconcentration for SLIM IM-MS analysis. The combined LC-SLIM IM separation peak capacities exceeded 3600 with a measurement throughput that is similar to current one-dimensional (1D) LC-MS proteomic analyses.

Dou, Maowei↗

SDSS IV MaNGA: characteristics of edge-on galaxies with a counter-rotating gaseous disc

ABSTRACT Counter-rotating components in galaxies are one of the most direct forms of evidence for past gas accretion or merging. We discovered 10 edge-on disc gaseous counter-rotators in a sample of 523 edge-on galaxies identified in the final MaNGA (Mapping Nearby Galaxies at APO) IFU sample. The counter-rotators tend to located in small groups. The gaseous counter-rotators have intermediate stellar masses and and located in the green valley and red sequence of the colour–magnitude diagram. The average vertical extents of the stellar and ionized gas discs are the same as for the rest of the sample while their radial gas and stellar distributions are more centrally concentrated. This may point at angular momentum loss during the formation process of the counter-rotating discs. The counter-rotators have low gas and dust content, weak emission-line strengths, and low star formation rates. This suggests that the formation of counter-rotators may be an efficient way to quench galaxies. One counter-rotator, SDSS J080016.09+292817.1 (Galaxy F), has a post-starburst region and a possible AGN at the centre. Another counter-rotator, SDSS J131234.03+482159.8 (Galaxy H), is identified as a potential ongoing galaxy interaction with its companion satellite galaxy, a gas-rich spiral galaxy. This may be representative case of a gaseous counter-rotator forming through a merger origin. However, tidal distortions expected in mergers are only found in a few of the galaxies and we cannot rule out direct gas accretion as another formation mechanism.

Beom, Minje↗

Yield and ion distribution for the barium cloud at 31,000 kilometers, September 21, 1971.

The photon flux density associated with the 4554-A resonance radiation for Ba II was measured at Mount Hopkins, Arizona, and Cerro Morado, Chile, and was determined to be 36,000 photon/sq cm sec outside the atmosphere; this measurement was made when the cloud was optically thin at 120 sec after release. Using this and a photon scattering efficiency of 0.66 photon/ion sec we estimate a 1.7-kg yield of barium ions that are formed from the initially released atomic barium and are thus associated with the main core of the cloud. Photographic and photometric data are combined to obtain preliminary values for the brightness throughout the cloud for two photographs, and isobrightness plots are presented. These plots indicate that the cloud is quite narrow, that a considerable portion of the ionized barium is outside the main core after a few minutes, and that the striations contain only a small fraction of the total material.

Manring, E. R.↗

IUE observations of DQ Herculis and its nebula, and the nature of the cold nova shells

The nebula ejected in the 1934 outburst of the classical nova DQ Her is remarkable for its unprecedentedly low temperature of Te 500 K as measured by Williams et al. (1978). In this paper, IUE observations are combined with Steward optical spectra. It is confirmed that the gas is quite cold. It is further shown that the gas is ionized by the radiation field of the central object. X-ray, ultraviolet, optical and infrared observations of the underlying binary are combined with the extreme-ultraviolet continuum deduced from the level of ionization of the nebula to obtain a composite energy distribution for the central object. This energy distribution bears no resemblance to that predicted by theoretical models of accretion disks. Photoionization models of the nebula using the deduced continuum, as well as theoretical accretion disk continua, are presented to show that the low electron temperature is the result of the very high metal abundances which characterize nova shells. Infrared fine-structure lines are efficient coolants, and low temperatures are achieved for a wide variety of radiation fields. The implications of these results for nebulae surrounding other old novae are discussed.

Ferland, G. J.↗

FPGA-Based, Self-Checking, Fault-Tolerant Computers

A proposed computer architecture would exploit the capabilities of commercially available field-programmable gate arrays (FPGAs) to enable computers to detect and recover from bit errors. The main purpose of the proposed architecture is to enable fault-tolerant computing in the presence of single-event upsets (SEUs). [An SEU is a spurious bit flip (also called a soft error) caused by a single impact of ionizing radiation.] The architecture would also enable recovery from some soft errors caused by electrical transients and, to some extent, from intermittent and permanent (hard) errors caused by aging of electronic components. A typical FPGA of the current generation contains one or more complete processor cores, memories, and highspeed serial input/output (I/O) channels, making it possible to shrink a board-level processor node to a single integrated-circuit chip. Custom, highly efficient microcontrollers, general-purpose computers, custom I/O processors, and signal processors can be rapidly and efficiently implemented by use of FPGAs. Unfortunately, FPGAs are susceptible to SEUs. Prior efforts to mitigate the effects of SEUs have yielded solutions that degrade performance of the system and require support from external hardware and software. In comparison with other fault-tolerant- computing architectures (e.g., triple modular redundancy), the proposed architecture could be implemented with less circuitry and lower power demand. Moreover, the fault-tolerant computing functions would require only minimal support from circuitry outside the central processing units (CPUs) of computers, would not require any software support, and would be largely transparent to software and to other computer hardware. There would be two types of modules: a self-checking processor module and a memory system (see figure). The self-checking processor module would be implemented on a single FPGA and would be capable of detecting its own internal errors. It would contain two CPUs executing identical programs in lock step, with comparison of their outputs to detect errors. It would also contain various cache local memory circuits, communication circuits, and configurable special-purpose processors that would use self-checking checkers. (The basic principle of the self-checking checker method is to utilize logic circuitry that generates error signals whenever there is an error in either the checker or the circuit being checked.) The memory system would comprise a main memory and a hardware-controlled check-pointing system (CPS) based on a buffer memory denoted the recovery cache. The main memory would contain random-access memory (RAM) chips and FPGAs that would, in addition to everything else, implement double-error-detecting and single-error-correcting memory functions to enable recovery from single-bit errors.

Some, Raphael↗

Erratum to: Soft- and reactive landing of ions onto surfaces: concepts and applications

Soft- and reactive landing of mass-selected ions is gaining attention as a promising approach for the precisely-controlled preparation of materials on surfaces that are not amenable to deposition using conventional methods. A broad range of ionization sources and mass filters are available that make ion soft-landing a versatile tool for surface modification using beams of hyperthermal (<100?eV) ions. The ability to select the mass-to-charge ratio of the ion, its kinetic energy and charge state, along with precise control of the size, shape, and position of the ion beam on the deposition target distinguishes ion soft landing from other surface modification techniques. Soft- and reactive landing have been used to prepare interfaces for practical applications as well as precisely-defined model surfaces for fundamental investigations in chemistry, physics, and materials science. For instance, soft- and reactive landing have been applied to study the surface chemistry of ions isolated in the gas-phase, prepare arrays of proteins for high-throughput biological screening, produce novel carbon-based and polymer materials, enrich the secondary structure of peptides and the chirality of organic molecules, immobilize electrochemically-active proteins and organometallics on electrodes, create thin films of complex molecules, and immobilize catalytically active organometallics as well as ligated metal clusters. In addition, soft landing has enabled investigation of the size-dependent behavior of bare metal clusters in the critical subnanometer size regime where chemical and physical properties do not scale predictably with size. The morphology, aggregation, and immobilization of larger bare metal nanoparticles, which are directly relevant to the design of catalysts as well as improved memory and electronic devices, have also been studied using ion soft landing. This review article begins in section 1 with a brief introduction to the existing applications of ion soft- and reactive landing. Section 2 provides an overview of the ionization sources and mass filters that have been used to date for soft landing of mass-selected ions. A discussion of the competing processes that occur during ion deposition as well as the types of ions and surfaces that have been investigated follows in section 3. Section 4 discusses the physical phenomena that occur during and after ion soft landing, including retention and reduction of ionic charge along with factors that impact the efficiency of ion deposition. The influence of soft landing on the secondary structure and biological activity of complex ions is addressed in section 5. Lastly, an overview of the structure and mobility as well as the catalytic, optical, magnetic, and redox properties of bare ionic clusters and nanoparticles deposited onto surfaces is presented in section 6. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 35:439–479, 2016.

Johnson, Grant E.↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100% fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 μm width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. Overall, the experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

47 OTHER INSTRUMENTATION↗

Two-dimensional polythiophene homopolymer as promising hole transport material for high-performance perovskite solar cells

A polythiophene homopolymer with conjugated side chains (2D-PT) was applied as a hole transport material (HTM) of perovskite solar cells (PSCs). The all-conjugated two-dimensional structure effectively increases the ionization potential, realizing a high open-circuit voltage near 1 V for the 2D-PT-based PSC. Very interestingly, the two-dimensional wide-angle X-ray scattering measurements show that the 2D-PT molecules are self-assembled into ordered structure with a face-on dominant orientation and exhibit a hole mobility, which is ~1.6 times faster than that of poly(3-hexylthiophene) (P3HT). Consequently, the power conversion efficiency of PSC is noticeably increased by ~30% as 2D-PT replaces P3HT as HTM. Moreover, the densely packed 2D-PT slows down the moisture induced degradation of perovskite crystals, leading to a better environmental stability. As a result, this work demonstrates that two-dimensional non-donor-acceptor structural conjugated polymers can be utilized as promising HTM of PSCs.

36 MATERIALS SCIENCE↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗