Search NASA⌕ Search

SEARCH · Search NASA

Results for “isolated systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A Sub-Hertz, Low-Frequency Vibration Isolation Platform

One of the major technical problems deep-space optical communication (DSOC) systems need to solve is the isolation of the optical terminal from vibrations produced by the spacecraft navigational control system and by the moving parts of onboard instruments. Even under these vibration perturbations, the DSOC transceivers (telescopes) need to be pointed l000 fs of times more accurately than an RF communication system (parabolic antennas). Mechanical resonators have been extensively used to provide vibration isolation for groundbased, airborne, and spaceborne payloads. The effectiveness of these isolation systems is determined mainly by the ability of designing a mechanical oscillator with the lowest possible resonant frequency. The Low-Frequency Vibration Isolation Platform (LFVIP), developed during this effort, aims to reduce the resonant frequency of the mechanical oscillators into the sub-Hertz region in order to maximize the passive isolation afforded by the 40 dB/decade roll-off response of the resonator. The LFVIP also provides tip/tilt functionality for acquisition and tracking of a beacon signal. An active control system is used for platform positioning and for dampening of the mechanical oscillator. The basic idea in the design of the isolation platform is to use a passive isolation strut with an approximately equal to 100-mHz resonance frequency. This will extend the isolation range to lower frequencies. The harmonic oscillator is a second-order lowpass filter for mechanical disturbances. The resonance quality depends on the dissipation mechanisms, which are mainly hysteretic because of the low resonant frequency and the absence of any viscous medium. The LFVIP system is configured using the well-established Stewart Platform, which consists of a top platform connected to a base with six extensible struts (see figure). The struts are attached to the base and to the platform via universal joints, which permit the extension and contraction of the struts. The struts ends are connected in pairs to the base and to the platform, forming an octahedron. The six struts provide the vibration isolation due to the properties of mechanical oscillators that behave as second-order lowpass filters for frequencies above the resonance. At high frequency, the ideal second-order low-pass filter response is spoiled by the distributed mass and the internal modes of membrane and of the platform with its payload.

Ortiz, Gerardo, G.↗

The velocity dispersion of the giant molecule clouds: A viscous origin

The observations of interstellar cloud motion show that the cloud velocity dispersion is nearly constant, to within a factor of 2, for clouds covering at least three orders of magnitude in mass. For example, the Giant Molecular Cloud (GMC) with typical masses of approx 5 x 10 to the 5th power solar masses have a one-dimensional planar, cloud-cloud, random velocity dispersion of approx 3-7 km/s. The HI clouds, of approx. 400 solar masses each, on the other hand, have a typical one-dimensional velocity dispersion of approx 6 km/s. Clearly, the clouds are not in kinetic energy equipartion. The GMC spatial distribution in the galactic disk is not that of an isolated, 3-D system; rather, the GMCs exhibit a very thin disk (approx nearly a monolayer) distribution; with the ratio of the diameter of a typical GMC to the vertical scale-height of the GMC distribution being approx 50 pc/150 pc = 0.3. The supernova shocks, which can accelerate the low mass clouds, are extremely ineffective in accelerating the GMCs because of the much larger mass/area ratio for the GMCs. The above points suggest that the GMCs do not constitute an isolated, 3-D system - rather, they indicate that the dynamics of the GMCs is mainly determined by the fact that they are located in a differentially rotating galactic disk, and that, as for particles in planetary rings, viscosity is the primary energy input. Specifically, it is proposed that gravitational scattering of the massive clouds off each other in the differentially rotating galactic disk constitutes an effective gravitational viscosity, which causes an increase in the random kinetic energy of the GMCs at the expense of their ordered, rotational kinetic energy.

Jog, C. J.↗

Control and protection system for paralleled modular static inverter-converter systems

A control and protection system was developed for use with a paralleled 2.5-kWe-per-module static inverter-converter system. The control and protection system senses internal and external fault parameters such as voltage, frequency, current, and paralleling current unbalance. A logic system controls contactors to isolate defective power conditioners or loads. The system sequences contactor operation to automatically control parallel operation, startup, and fault isolation. Transient overload protection and fault checking sequences are included. The operation and performance of a control and protection system, with detailed circuit descriptions, are presented.

Birchenough, A. G.↗

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗

On the development of system-theoretic tools for the design of integrated health monitoring and controls for rocket propulsion systems

As NASA continues to develop various advanced propulsion technologies for space exploration, two factors are becoming increasingly dominant in design specifications: increase operational reliability and decrease operational cost. One approach that has been proposed to meet these challenges is to incorporate into current and future rocket propulsion systems some sort of diagnostic/monitoring capability in the form of a Health Monitoring System (HMS). HMS technology offers the promise of increased operational reliability through its ability to assess system performance, detect and isolate degradations and/or failures, and modify system operation so as to minimize negative effects on performance. The purpose of this research is to study, from a systems engineering perspective, the particular issues of analysis and synthesis for generic HMS's.

Helmicki, Arthur J.↗

System and method for collecting and isolating radiosotopes

A method for obtaining 225 AC from 225 Ra having the steps of assembling a column having an inorganic stationary phase; priming the column to immobilize 226 Ra 225 Ra and natural decay products therefrom; immobilizing the 226 Ra, 225 Ra, 224 Ra, and natural decay products therefrom onto a stationary phase within the column; and eluting the column containing the 225 Ra with an aqueous sulfate solution to obtain a milking effluent that contains 225 AC. Also provided is a method for obtaining pure 225 AC from its isotope parents, the method comprising assembling a column having a stationary phase comprising an inorganic material; priming the column with the isotope parents to immobilize 225 Ac, and natural decay products of 225 AC; immobilizing the 225 Ac, and natural decay products therefrom onto the stationary phase within the column 226 Ra, 225 Ra, 224 Ra; and eluting the column containing the 225 AC to obtain an effluent that contains the isotope parents.

Brown, Michael A.↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations in the design of tip-coupled air-transport systems

It is shown that the lift-drag ratio of tip-coupled systems can be expressed as a simple multiple of the lift-drag ratio of the isolated units comprising the system. When operated for maximum lift-drag ratio, the extent of the coupled system is limited by maximum lift coefficient, high-altitude engine characteristics, and degraded performance of the isolated unit climbing to couple into the system. When operated at constant altitude, the gain from coupling is severely limited. If the cruise altitude is that for best performance of the isolated unit, the system lift-drag ratio can be no better than twice that of the isolated unit even when an infinite number of units are coupled. System performance may be further degraded since span-load distributions which yield good performance for the individual units reduce the efficiency of the coupled system. Coupling a pair of modern transport aircraft results in only about half the expected gain because of a poor span-distribution across the coupled pair. The control deflections required to maintain roll and pitch equilibrium further degrade the possible gain.

Heyson, H. H.↗

Explaining compact groups as change alignments

The physical nature of the apparently densest groups of galaxies, known as compact groups is a topic of some recent controversy, despite the detailed observations of a well-defined catalog of 100 isolated compact groups compiled by Hickson (1982). Whereas many authors have espoused the view that compact groups are bound systems, typically as dense as they appear in projection on the sky (e.g., Williams & Rood 1987; Sulentic 1987; Hickson & Rood 1988), others see them as the result of chance configurations within larger systems, either in 1D (chance alignments: Mamon 1986; Walke & Mamon 1989), or in 3D (transient cores: Rose 1979). As outlined in the companion review to this contribution (Mamon, in these proceedings), the implication of Hickson's compact groups (HCGs) being dense bound systems is that they would then constitute the densest isolated systems of galaxies in the Universe and the privileged site for galaxy interactions. In a previous paper (Mamon 1986), the author reviewed the arguments given for the different theories of compact groups. Since then, a dozen papers have been published on the subject, including a thorough and perceptive review by White (1990), thus more than doubling the amount written on the subject. Here, the author first enumerates the arguments that he brought up in 1986 substantiating the chance alignment hypothesis, then he reviews the current status of the numerous recent arguments arguing against chance alignments and/or for the bound dense group hypothesis (both for the majority of HCGs but not all of them), and finally he reconsiders each one of these anti-chance alignment arguments and shows that, rather than being discredited, the chance alignment hypothesis remains a fully consistent explanation for the nature of compact groups.

Mamon, Gary A.↗

Fault isolation and fault-tolerant control for nonlinear stochastic distribution control systems with multiplicative faults

Here, in this paper, a fault isolation, diagnosis and fault tolerant control algorithm is proposed for nonlinear multiple multiplicative faults stochastic distribution control systems employing Takagi–Sugeno fuzzy system. To obtain the detailed fault information, a fault detection algorithm is introduced to discover the fault occurrence time. Then a fault isolation observer is built to produce the residual, and the error system is separated to subsystems affected only by disturbance and multiplicative faults. Moreover, a fault estimation scheme is presented to obtain the fault magnitude information. When faults occur, the system output probability density function will deviate from the desired distribution. So the model predictive control fault tolerant control scheme is needed to minimize the impact of faults as much as possible to make sure that the post fault output probability density function track the desired probability density function. The validity of the designed algorithm is demonstrated through a simulation example, where the fault tolerant control algorithm ensures that the system output probability density function still track the given output probability density function despite the complex case of multiple multiplicative faults occurring simultaneously.

42 ENGINEERING↗

Reactivity, Mechanism, and Assembly of the Alternative Nitrogenases

Biological nitrogen fixation is catalyzed by the enzyme nitrogenase, which facilitates the cleavage of the relatively inert triple bond of N 2 . Nitrogenase is most commonly associated with the molybdenum–iron cofactor called FeMoco or the M-cluster, and it has been the subject of extensive structural and spectroscopic characterization over the past 60 years. In the late 1980s and early 1990s, two “alternative nitrogenase” systems were discovered, isolated, and found to incorporate V or Fe in place of Mo. These systems are regulated by separate gene clusters; however, there is a high degree of structural and functional similarity between each nitrogenase. Limited studies with the V- and Fe-nitrogenases initially demonstrated that these enzymes were analogously active as the Mo-nitrogenase, but more recent investigations have found capabilities that are unique to the alternative systems. In this review, we will discuss the reactivity, biosynthetic, and mechanistic proposals for the alternative nitrogenases as well as their electronic and structural properties in comparison to the well-characterized Mo-dependent system. Studies over the past 10 years have been particularly fruitful, though key aspects about V- and Fe-nitrogenases remain unexplored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attitude Determination and Control System (ADCS) and Maintenance and Diagnostic System (MDS): A maintenance and diagnostic system for Space Station Freedom

The Maintenance and Diagnostic System (MDS) that is being developed at Honeywell to enhance the Fault Detection Isolation and Recovery system (FDIR) for the Attitude Determination and Control System on Space Station Freedom is described. The MDS demonstrates ways that AI-based techniques can be used to improve the maintainability and safety of the Station by helping to resolve fault anomalies that cannot be fully determined by built-in-test, by providing predictive maintenance capabilities, and by providing expert maintenance assistance. The MDS will address the problems associated with reasoning about dynamic, continuous information versus only about static data, the concerns of porting software based on AI techniques to embedded targets, and the difficulties associated with real-time response. An initial prototype was built of the MDS. The prototype executes on Sun and IBM PS/2 hardware and is implemented in the Common Lisp; further work will evaluate its functionality and develop mechanisms to port the code to Ada.

Toms, David↗

Fault Diagnosis of Power Systems Using Intelligent Systems

The power system operator's need for a reliable power delivery system calls for a real-time or near-real-time Al-based fault diagnosis tool. Such a tool will allow NASA ground controllers to re-establish a normal or near-normal degraded operating state of the EPS (a DC power system) for Space Station Alpha by isolating the faulted branches and loads of the system. And after isolation, re-energizing those branches and loads that have been found not to have any faults in them. A proposed solution involves using the Fault Diagnosis Intelligent System (FDIS) to perform near-real time fault diagnosis of Alpha's EPS by downloading power transient telemetry at fault-time from onboard data loggers. The FDIS uses an ANN clustering algorithm augmented with a wavelet transform feature extractor. This combination enables this system to perform pattern recognition of the power transient signatures to diagnose the fault type and its location down to the orbital replaceable unit. FDIS has been tested using a simulation of the LeRC Testbed Space Station Freedom configuration including the topology from the DDCU's to the electrical loads attached to the TPDU's. FDIS will work in conjunction with the Power Management Load Scheduler to determine what the state of the system was at the time of the fault condition. This information is used to activate the appropriate diagnostic section, and to refine if necessary the solution obtained. In the latter case, if the FDIS reports back that it is equally likely that the faulty device as 'start tracker #1' and 'time generation unit,' then based on a priori knowledge of the system's state, the refined solution would be 'star tracker #1' located in cabinet ITAS2. It is concluded from the present studies that artificial intelligence diagnostic abilities are improved with the addition of the wavelet transform, and that when such a system such as FDIS is coupled to the Power Management Load Scheduler, a faulty device can be located and isolated from the rest of the system. The benefit of these studies provides NASA with the ability to quickly restore the operating status of a space station from a critical state to a safe degraded mode, thereby saving costs in experimentation rescheduling, fault diagnostics, and prevention of loss-of-life.

Momoh, James A.↗

EKG isolator

Light beam transmits heartbeat signal from electrodes on patient to electrocardiograph without exposing patient to possible severe electrical shock. System provides complete isolation between patient and EKG instrumentation.

Palmer, E.↗

Paraboloidal-Dish Power Modules

Study determines configurational tradeoffs for particular paraboloidal-dish power system for isolated-load applications. Continuous level of power supplied with high reliability by using power system with modular paraboloidal-dish power units.

Revere, W. R.↗