Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Proton acceleration in an overdense hydrogen plasma by intense CO 2 laser pulses with nonlinear propagation effects in the underdense pre-plasma

We report on proton acceleration from intense CO 2 laser-irradiated hydrogen plasmas at near-critical densities, with the density gradient steepened by Nd:YAG laser ablation-driven hydrodynamic shocks. While the experimental results, such as the quasi-monoenergetic proton spectra and their scaling with respect to the laser energy, are generally in agreement with the simulations, certain laser shots produced significantly higher proton energies than anticipated during the experiment. The increased proton energy may be linked to nonlinear propagation effects in the steepened plasma density ramp before the critical surface, including relativistic self-focusing and, for the case of temporally-structured laser pulses observed in the experiment, focusing of the trailing pulse through the plasma channel formed by the leading pulse 25 ps ahead. The occurrence of channel focusing in the underdense hydrogen plasma is supported by a subsequent pump-probe experiment with a dark-field imaging technique, where the formation of ion channels was observed after the passage of an intense CO 2 laser pulse

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser breakdown in air at ultrahigh laser pulse repetition rates

Some specific features of interaction of intense femtosecond laser pulses with air at ultrahigh pulse repetition rates have been experimentally studied. Data on the dynamics of plasma cloud expansion and the plasma electron density on time intervals no longer than 10 ns are obtained by femtosecond interferometry. These data are interpreted in terms of the most likely mechanisms of ionised gas recombination. The effect of ultrahigh-frequency laser radiation on a medium was modelled by double-pulse irradiation with a short delay {Delta}t between the pulses: from 1 ps to 11 ns. A nonmonotonic dependence of the degree of air ionisation by the second pulse on the delay time {Delta}t is found; possible mechanisms of these dependences are discussed in terms of the processes of femtosecond radiation absorption in the residual plasma. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linewidth narrowing and wideband frequency modulation of a DBR laser

We present a scheme to phase-lock a 240 mW, 852 nm distributed Bragg reflector (DBR) laser to a fixed-frequency narrow-linewidth laser with a rapidly tunable frequency offset near 9 GHz. The phase-lock is accomplished by electronic feedback on the beatnote between the two lasers. The frequency offset can be swept 200 MHz in 300 us, limited by the feedback loop bandwidth, allowing for its use in complex cooling and state preparation schemes needed in atomic physics experiments. Here, we find that the phase-lock reduces the linewidth of the DBR laser below its natural linewidth of ~400 kHz to ~100 kHz

47 OTHER INSTRUMENTATION↗

Extending the laser-specklegram technique to strain analysis of rotating components

A technique involving sandwich-speckle interferometry has been investigated for application in making strain measurements on rotating structures. The technique has proven to be effective in relaxing stringent timing requirements for recording laser photographs and provides extended ranges of displacement measurement. Application of the technique to an experimental rotating specimen has demonstrated the potential of the method for making accurate strain measurements.

Chien, C. H.↗

Coherent population trapping in Raman-pulse atom interferometry

Raman pulse atom interferometry is an important modality for precision measurements of inertial forces and tests of fundamental physics. Typical Raman atom optics use two coherent laser fields applied at gigahertz-scale detunings from optical resonance, so that spontaneous emission produces a minor or negligible source of decoherence. An additional consequence of spontaneous emission is coherent population trapping (CPT). We show that CPT produces coherences and population differences which induce systematic effects in Raman pulse atom interferometers. We do not believe that CPT has been previously identified as an error mechanism in Raman pulse atom interferometry. We present an experimental characterization of CPT coherences and population differences induced in laser-cooled cesium atoms by application of Raman pulses at detunings near 1 GHz, commensurate with detunings used in several precision measurement experiments. We are not aware of previous demonstrations of CPT-induced population difference. We argue that CPT effects could induce phase shifts of several milliradians in magnitude for typical experimental parameters and stipulate that these errors can be suppressed by propagation direction reversal in Raman interferometer-based precision measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lasers, extreme UV and soft X-ray

Three decades ago, large ICF lasers that occupied entire buildings were used as the energy sources to drive the first X-ray lasers. Today X-ray lasers are tabletop, spatially coherent, high-repetition rate lasers that enable many of the standard optical techniques such as interferometry to be extended to the soft X-ray regime between wavelengths of 10 and 50 nm. Over the last decade X-ray laser performance has been improved by the use of the grazing incidence geometry, diode-pumped solid-state lasers, and seeding techniques. The dominant X-ray laser schemes are the monopole collisional excitation lasers either driven by chirped pulse amplification (CPA) laser systems or capillary discharge. The CPA systems drive lasing in neon-like or nickel-like ions, typically in the 10 – 30 nm range, while the capillary system works best for neon-like argon at 46.9 nm. Most researchers use nickel-like ion lasers near 14 nm because they are well matched to the Mo:Si multilayer mirrors that have peak reflectivity near 13 nm and are used in many applications. As a result, the last decade has seen the birth of the X-ray free electron laser (XFEL) that can reach wavelengths down to 0.15 nm and the inner-shell Ne laser at 1.46 nm.

42 ENGINEERING↗

Towards the development of a hybrid-integrated chip interferometer for online surface profile measurements

Non-destructive testing and online measurement of surface features are pressing demands in manufacturing. Thus optical techniques are gaining importance for characterization of complex engineering surfaces. Harnessing integrated optics for miniaturization of interferometry systems onto a silicon wafer and incorporating a compact optical probe would enable the development of a handheld sensor for embedded metrology applications. In this work, we present the progress in the development of a hybrid photonics based metrology sensor device for online surface profile measurements. The measurement principle along with test and measurement results of individual components has been presented. For non-contact measurement, a spectrally encoded lateral scanning probe based on the laser scanning microscopy has been developed to provide fast measurement with lateral resolution limited to the diffraction limit. The probe demonstrates a lateral resolution of ∼3.6 μm while high axial resolution (sub-nanometre) is inherently achieved by interferometry. Further the performance of the hybrid tuneable laser and the scanning probe was evaluated by measuring a standard step height sample of 100 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Dimensional Imaging with Multiple Wavelength Speckle Interferometry

We present the design, modeling, construction, and results of a three-dimensional imager based upon multiple-wavelength speckle interferometry. A surface under test is illuminated with tunable laser light in a Michelson interferometer configuration while a speckled image is acquired at each laser frequency step. The resulting hypercube is Fourier transformed in the frequency dimension and the beat frequencies that result map the relative offsets of surface features. Synthetic wavelengths resulting from the laser tuning can probe features ranging from 18 microns to hundreds of millimeters. Three dimensional images will be presented along with modeling results.

speckle interferometry↗

Using simultaneous x-ray diffraction and velocity interferometry to determine material strength in shock-compressed diamond

We determine the strength of laser shock-compressed polycrystalline diamond at stresses above the Hugoniot elastic limit using a technique combining x-ray diffraction from the Linac Coherent Light Source with velocity interferometry. X-ray diffraction is used to measure lattice strains, and velocity interferometry is used to infer shock and particle velocities. These measurements, combined with density-dependent elastic constants calculated using density functional theory, enable determination of material strength above the Hugoniot elastic limit. Furthermore, our results indicate that diamond retains approximately 20 GPa of strength at longitudinal stresses of 150–300 GPa under shock compression.

36 MATERIALS SCIENCE↗

Metrology of Large Parts

As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.

Stahl, H. Philip↗

Study of self-generated magnetic fields in laser produced plasmas using a three-channel polaro-interferometer

Self-generated magnetic fields produced in laser plasmas at moderate laser intensities have been measured using a three-channel polaro-interferometer. The main elements of this device are two birefringent calcite wedges placed between two crossed polarizers. Using this device, the spatial profiles of (a) the rotation angle (polarometry), (b) the electron density (interferometry), and (c) the transmitted probe beam intensity (shadowgraphy) are recorded simultaneously using a digital camera with a large format CCD in a single laser shot. Magnetic fields of 2-4 MG had been estimated in aluminum plasma at laser intensities {approx}10{sup 13} W/cm{sup 2}. It is also possible to use this device in other configurations to get time resolved information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments

The recent development of high-repetition rate x-ray free electron lasers (FEL), makes it possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. We describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS) for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. Furthermore, the signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.

42 ENGINEERING↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

SIM technolgy development overview - light at the end of the tunnel

Optical and infrared interferometry will open new vistas for astronomy over the next decade. Space based interferometers, operating unfettered by the Earth's atmosphere, will offer the greatest scientific payoff. They also present the greatest technological challenge: laser metrology systems must perform with sub-nanometer precision; mechanical vibrations must be controlled to nanometers requiring orders of magnitude disturbance rejection; a multitude of actuators and sensors must operate flawlessly and in concert. The Jet Propulsion Laboratory along with its industry partners are addressing these challenges with a development program that plans to establish technology readiness for the Space Interferometry Mission by end of 2004.

interferometry↗

Verification and validation of the open-source plasma fluid code: Zapdos

Zapdos is an open-source finite element plasma fluid solver based on the MOOSE multiphysics framework. This paper outlines Zapdos verification, benchmarking, and validation efforts for 1D and 2D RF capacitively coupled plasma discharge models for mid-range pressures (0.1 - 1 Torr). The verification process involved using the method of manufactured solutions to assess Zapdos spatial and temporal error convergence. L2 errors ranged from 10 -2 to 10 -4 , while the convergence’s slope were in agreement with the predicted slopes for the tested variable and time integration orders. The benchmarking process involved comparisons to previously results from the validated finite element code, LSODI. These works included 1D and 2D simulations for a range of plasma parameters (densities, temperatures, voltage, etc.). For the 1D cases, Zapdos and LSODI results were in very good agreement. In the 2D cases, variable behaviors matched, with slight discrepancies in peak values. The validation process involved comparisons to experimental works including electron density measurements by microwave interferometry and metastable density measurements by planar laser-induced fluorescence imaging. Results shown reasonable agreement at higher pressure, with results starting to diverge at low pressures. Furthermore, probable causes for this diverges are the limitation of the fluid assumption for plasmas at low pressure, or the need for more robust boundary conditions. Overall, Zapdos shown reasonable results for the verification, benchmarking, and validation efforts, and Zapdos can be downloaded at https://github.com/shannon-lab/zapdos.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetized Disruption of Inertially Confined Plasma Flows

Herein, the creation and disruption of inertially collimated plasma flows are investigated through experiment, simulation, and analytical modeling. Supersonic plasma jets are generated by laser-irradiated plastic cones and characterized by optical interferometry measurements. Targets are magnetized with a tunable $B$ field with strengths of up to 5 T directed along the axis of jet propagation. These experiments demonstrate a hitherto unobserved phenomenon in the laboratory, the magnetic disruption of inertially confined plasma jets. This occurs due to flux compression on axis during jet formation and can be described using a Lagrangian-cylinder model of plasma evolution implementing finite resistivity. The basic physical mechanisms driving the dynamics of these systems are described by this model and then compared with two-dimensional radiation-magnetohydrodynamic simulations. Experimental, computational, and analytical results discussed herein suggest that contemporary models underestimate the electrical conductivity necessary to drive the amount of flux compression needed to explain observations of jet disruption.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD) between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL) pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. In conclusion, this is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗