Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

Disruption modelling for engineering and physics design of ST-E1 fusion power plant

Plasma disruptions represent a critical challenge for high-performance tokamak operations, as they can compromise machine integrity and reduce operational availability. Although future fusion devices essentially need to incorporate strategies to minimise disruption occurrence, complete avoidance remains unattainable. Consequently, assessing and characterising unmitigated disruption consequences is fundamental for the design and qualification of next-generation fusion power plants. This work supports the pre-conceptual design of ST-E1, a low aspect-ratio Tokamak Fusion Power Plant developed by Tokamak Energy Ltd., by presenting a comprehensive disruption modelling approach applied across different design stages. The methodology integrates both physics and engineering considerations to evaluate the impact of disruptions on machine performance and structural integrity. From an engineering perspective, several ST-E1 layout options were analysed to investigate the electromagnetic response of key components under disruption-induced loads, enabling comparison between alternative design solutions. On the physics side, a broad set of disruption scenarios was explored, scanning operational space parameters, plasma-material interactions, and associated thermal loads. Furthermore, the study examined variations in disruption behaviour arising from different reference equilibria, focusing on a range starting from Double Null to Single Null configurations, reflecting the increasing up-down asymmetry consequences. The results reveal significant contrasts in plasma dynamics and structures electromagnetic behaviour between configurations, highlighting the importance of disruption modelling in guiding design choices. These analyses have proven instrumental in shaping ST-E1 development, offering critical insights for mitigating risks and optimising future fusion power plant designs.

Borowiec, Katarzyna [ORNL] (ORCID:0000000335911739↗

SOLPS-ITER modeling of a dedicated divertor for negative triangularity operation on DIII-D

The design of a new dedicated divertor for negative triangularity (NT) operation on DIII-D with neutral baffles and pumping is informed by SOLPS-ITER transport modeling. This dedicated NT divertor is the latest step in a progression of NT shapes with various divertor characteristics explored on DIII-D, including NT shapes at reduced triangularity and a campaign with stronger shaping that included new armored components on the outboard side. SOLPS simulations played a key role in these divertor designs. Interpretive simulations, using cross-field diffusivities constrained by experimental data in the NT Shelf shape were used to inform the design of the 2023 armor campaign components. A similar procedure used armor campaign data to predict conditions for the dedicated NT divertor. The predictive simulations were used to assess the divertor fluxes, detachment threshold, pumped flux, and neutral leakage. For the dedicated NT divertor, SOLPS simulations and two-point-modeling were used to show the relative impact of magnetic topology (mainly longer connection length) and divertor closure on the divertor conditions relative to the armor campaign. It is predicted that the dedicated NT divertor reaches detachment (measured by target ion flux rollover) at a lower upstream density (≈(1.75−−2.4)×1⁢019m−3) as compared to the armor campaign shape. For the preliminary design geometry, divertor closure reduces the neutral leakage by ≈10%. Parametric optimization indicating further ≈20%–60% improvement in the leakage flux and recycled flux crossing the pump entrance is possible for relatively minor changes to the divertor and baffle layout.

Lore, Jeremy [ORNL] (ORCID:000000029192465X)↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved geophysical monitoring of carbon sequestration through parameter linkage to reservoir modeling

Predictive reservoir modeling, even if present in the form of only basic hydrogeological model assumptions, is expected to accompany the majority of carbon capture and sequestration monitoring activities. It thus represents a source of prior information about the migration of injected fluids that can benefit geophysical survey planning and ensuing monitoring. Constraining the imaging of geophysical monitoring data with reservoir modeling is preferable over standalone geophysical imaging because of additional complementary hydrogeological information. However, fully coupled hydrogeophysical data inversion for flow-modeling parameters that control saturation predictions is an involved process. Within the context of three-dimensional electromagnetic (EM) inversion of data from borehole-to-surface layouts, we employ a "poor people's" alternative. The approach constrains geophysical inversion parameters through saturation predictions. The coupling is realized through spatially variable lower and upper parameter bounds that scale with gas saturation magnitudes, the latter provided by reservoir modeling. In this work, enhancement of three-dimensional time-lapse plume EM imaging is demonstrated for simulated sequestration into a depleted gas reservoir.

58 GEOSCIENCES↗

Elastic-wave sensitivity-guided adaptive seismic survey design for cost-effective monitoring of geological carbon storage

Effective seismic monitoring is essential for verifying CO₂ containment, detecting potential leakage, and optimizing operational decisions in geologic carbon storage. Here, this study presents a time-adaptive, elastic-wave sensitivity-guided framework for designing cost-effective seismic monitoring layouts for tracking CO₂ plume migration. The method is based on elastic-wave sensitivity analysis, which quantifies how variations in subsurface properties impact seismic wavefields. Two complementary design strategies are developed: one based on selecting a fixed number of seismic sources (Method A), and the other based on selecting source–receiver pairs contributing to a fixed fraction of cumulative elastic-wave sensitivity energy (Method B). The optimization workflow to identify source–receiver configurations with the highest detection potential is demonstrated using a hypothetical GCS scenario at the Kimberlina site in California using simulations of elastic-wave sensitivity data at multiple post-injection timesteps. Results show that both strategies adapt to evolving plume geometries and wavefield sensitivities, with Method B offering broader spatial coverage and Method A ensuring simpler deployment. This framework enables site-specific, cost-effective, and risk-informed seismic survey designs, enhancing the ability to monitor CO₂ migration over time in evolving geological environments

58 GEOSCIENCES↗

Materials-to-device design of hybrid metal-polymer heat exchanger tubes for low temperature waste heat recovery

Heat exchangers for low temperature (<150 °C) waste heat recovery (WHR) are challenging due to severe constraints on materials costs, manufacturing methods, and maintenance opportunities after installation. Here, the use of polymers instead of metals, offers an avenue for cost reduction in WHR applications, provided the typical low thermal conductivity of polymers (~0.2 W m –1 K –1 ) that results in poor overall heat transfer coefficient can be overcome. Previous approaches to enhance the thermal conductivity of polymers remain problematic in terms of cost, thermal, and thermomechanical considerations. In this work, we propose a novel hybrid metal-polymer composite assembled from strips of polymer and copper. Polymer strips with metal-clad edges are wound helically and the interfaces between the strips joined to obtain a tube for a cross-flow heat exchanger. Interfaces are designed to enhance effective heat conduction across the material and increase the overall heat transfer coefficient. Through numerical simulations, we obtain metal-polymer layouts that achieve wall effective thermal conductivity ~1 W m –1 K –1 at ~23% or ~35% volume fraction of copper or aluminum, respectively. The conductivity enhancement is sufficient for typical low temperature WHR, resulting in a ~20% enhancement in the overall heat transfer coefficient compared to a similar all-polymer heat exchanger. Thermomechanical simulations revealed that the composite pipe designs can withstand >1.4 MPa internal pressure, under the normal operating conditions of the heat exchanger. Our work provides guidelines for designing macroscopic metal-polymer composites that can be adapted for specific requirements such as reduced materials costs, ease of manufacturing, and heat transfer enhancement. In conclusion, the optimized design of hybrid metal-polymer heat exchanger tubes potentially provides a scalable and cost-effective route toward harvesting waste heat from low temperature sources.

42 ENGINEERING↗

Controlled 3D nanoparticle deposition by drying of colloidal suspension in designed thin micro-porous architectures

Nanoparticle deposition by drying of colloidal suspension in thin micro-porous architectures has attracted a lot of attention in scientific research as well as industrial applications. However, the underlying mechanisms of such three-dimensional (3D) deposition are not yet fully revealed due to the complexity of the co-occurring processes of two-phase fluid flows, phase change and mass transport. Consequently, the control of 3D nanoparticle deposition remains a challenge. We use a combined experimental and numerical approach to achieve controlled 3D nanoparticle deposition by drying of colloidal suspension in two pillar-based thin micro-porous architectures. By the design of pillar layout, rectangular-spiral and circular-spiral deposition configurations are obtained globally. By varying the surface wettability, vertically symmetric and sloped nanoparticle depositions can be achieved locally. While the numerical modeling reveals the mechanisms of liquid internal flow, as well as the impact of local drying rate on nanoparticle transport, accumulation and final deposition, the experimental results of deposition configurations validate the controlling strategies. This combined experimental and numerical work provides a framework to achieve desired 3D nanoparticle deposition in thin micro-porous architectures, with a thorough understanding of the underlying mechanisms of two-phase fluid flows, phase change and mass transport.

36 MATERIALS SCIENCE↗

Bio-inspired alula-based winglet design for enhanced heat transfer in high temperature fin-and-tube heat exchangers

Fin-and-tube heat exchangers (FTHEs) are widely used for high-temperature flue-gas heat recovery, but their performance is often limited by wake regions and non-uniform fin-surface temperatures. This study proposes and numerically evaluates four bio-inspired longitudinal vortex generator (VG) configurations in a high-temperature FTHE with flue-gas inlet temperature ∼1230 K: double-delta, curved double-delta, alula, and a new curved-alula geometry. The reference fin is not hydraulically plain; it already incorporates leading-edge separation columns and convex protrusions, so the alula-type winglets are assessed as downstream add-ons acting on a strongly disturbed flow. In a second step, perforations (one, two and three circular holes) are introduced into the curved-alula VGs to further tailor the flow field. Three-dimensional simulations with the Shear Stress Transpor (SST) $k - ω$ model, temperature-dependent flue-gas properties and conjugate conduction are carried out for gas-side Reynolds numbers $Re_g ≈ 8.0$ x $10^2 - 3.6$ x $10^3$ (mass flow rates 0.5 – 2.5 g/s), and the designs are compared in terms of surface heat flux, Nusselt number, friction factor and hydrothermal performance factor (HTPF). For this already-promoted fin, the additional downstream winglets provide moderate, incremental hydrothermal gains. At the highest Reynolds number, the best non-perforated design (curved-alula) increases surface heat flux from 1630.9 to 1794.7 kW/m² (∼ 10 % gain) and the Nusselt number from 227.6 to 242.6 (∼ 7 % gain), while the friction factor rises from 0.26 to about 0.30, yielding HTPF values close to unity (∼ 0.9 – 1.0). Introducing circular perforations into the curved-alula winglets acts mainly as a wake-bleeding refinement: the three-hole configuration provides a heat flux of 1824.7 kW/m² and a pressure drop of 127.9 Pa, with HTPF in the range ∼ 1.03 – 1.14 and a small (∼ 1 – 3 %) improvement over the solid curved-alula design. Flow-field analysis shows that the perforated curved-alula VGs shrink tube-wake regions, thin the thermal boundary layer and homogenize the fin-surface temperature (outlet-gas temperature ∼ 510 – 520 K and fin-surface temperature ∼ 420 – 421 K for the three-hole case). An optimal flue-gas mass flow rate of ∼ 1 g/s ($Re_g ≈ 1.5$ x $10^3$) is identified, beyond which additional heat-transfer gains are offset by rapidly increasing pressure losses. Overall, the results highlight that initial fin geometry and VG placement are as important as VG shape: alula-based winglets are expected to yield larger relative gains on simpler flat-fin layouts or when positioned closer to the fin leading edge and tube

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward the application of the Risk-Based Maintenance approach to a hydrogen-fueled manufacturing plant

Safety, reliability, and maintenance of hydrogen-based equipment, including Risk-Based Maintenance (RBM), have recently gained increasing attention, as hydrogen, while key to decarbonizing hard-to-abate sectors, raises safety concerns. However, two literature gaps limit the development of risk-based strategies for hydrogen technologies. First, existing RBM methodologies do not account for hydrogen-specific components, such as electrolyzers, which differ from conventional equipment. Second, available studies on electrolyzer reliability remain largely qualitative or laboratory-scale. This study addresses these gaps by proposing an adapted RBM methodology tailored to hydrogen-fueled manufacturing facilities. Integrating qualitative tools (e.g., FMEA) with probabilistic models (e.g., Bayesian Networks) enables comprehensive hazardous scenarios identification and likelihood estimation. A conceptual layout of a glass furnace supplied by a 3 MW PEM electrolyzer is considered as a case study to demonstrate the feasibility of the adapted RBM framework in identifying high-risk components and enabling maintenance prioritization, potentially improving plant safety.

08 HYDROGEN↗

Quantitative Assessment of Workload and Stressors in Clinical Radiation Oncology

Purpose: Workload level and sources of stressors have been implicated as sources of error in multiple settings. We assessed workload levels and sources of stressors among radiation oncology professionals. Furthermore, we explored the potential association between workload and the frequency of reported radiotherapy incidents by the World Health Organization (WHO). Methods and Materials: Data collection was aimed at various tasks performed by 21 study participants from different radiation oncology professional subgroups (simulation therapists, radiation therapists, physicists, dosimetrists, and physicians). Workload was assessed using National Aeronautics and Space Administration Task-Load Index (NASA TLX). Sources of stressors were quantified using observational methods and segregated using a standard taxonomy. Comparisons between professional subgroups and tasks were made using analysis of variance ANOVA, multivariate ANOVA, and Duncan test. An association between workload levels (NASA TLX) and the frequency of radiotherapy incidents (WHO incidents) was explored (Pearson correlation test). Results: A total of 173 workload assessments were obtained. Overall, simulation therapists had relatively low workloads (NASA TLX range, 30-36), and physicists had relatively high workloads (NASA TLX range, 51-63). NASA TLX scores for physicians, radiation therapists, and dosimetrists ranged from 40-52. There was marked intertask/professional subgroup variation (P<.0001). Mental demand (P<.001), physical demand (P=.001), and effort (P=.006) significantly differed among professional subgroups. Typically, there were 3-5 stressors per cycle of analyzed tasks with the following distribution: interruptions (41.4%), time factors (17%), technical factors (13.6%), teamwork issues (11.6%), patient factors (9.0%), and environmental factors (7.4%). A positive association between workload and frequency of reported radiotherapy incidents by the WHO was found (r = 0.87, P value=.045). Conclusions: Workload level and sources of stressors vary among professional subgroups. Understanding the factors that influence these findings can guide adjustments to the workflow procedures, physical layout, and/or communication protocols to enhance safety. Additional evaluations are needed in order to better understand if these findings are systemic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the RBF meshless method to the solution of the radiative transport equation

In this paper, we introduce a radial basis function collocation method for computing solutions to the time-dependent radiative transfer equation. For these computations, we use finite differences to discretize the time coordinate, a discrete ordinate method to discretize the directional variable, and an expansion in radial basis functions to approximate the spatial dependence of the solution. The main advantages of the RBF method are that it does not require any mesh or grid, achieves spectral accuracy in multi-dimensions for arbitrary node layouts, and it is extremely simple to implement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dirty bomb source term characterization and downwind dispersion: Review of experimental evidence

Dirty bombs are considered one of the easiest forms of radiological terrorism, a form of terrorism based on the deliberate use of radiological material to cause adverse effects in a target population. One U.S. Government official has even described a dirty bomb attack as “all but inevitable”. While people in the vicinity of the blast may experience acute radiation effects, people downwind may unknowingly be contaminated by the radioactive airborne particulate and face increased long-term cancer risk. The likelihood of increased cancer risk depends on the radionuclide used and its specific activity, its aerosolization potential, the particle sizes generated in the blast, and where a person is with respect to the detonation. Different studies have reported that plausible radionuclides for dirty bomb include 60 Co, 90 Sr, 137 Cs, 192 Ir, 241 Am based on their availability in commercial sources as well as safeguards, the amount needed for adverse health effects, previous mishandling of radionuclides and malicious uses. In order to have increased long-term cancer risk, the radionuclide would have to deposit inside the body by entering the respiratory tract and then possibly migrate to other organs or bones (ground shine is not considered in this paper because areas affected by the event will likely become inaccessible). This implies that the particles will have to be smaller than 10 μm to be inhaled. Experiments involving the detonation of dirty bombs have shown that particles or droplets smaller than 10 μm are generated, independently from the initial radionuclide or its state (e.g., powder, solution). Atmospheric tests have shown that in unobstructed terrain, the radionuclide laden cloud can travel kilometers downwind even for relatively small amounts of explosives. Furthermore, buildings in the path of the cloud can change the dose rate. For instance, in one experiment with a single building, the dose rate was 1–2 orders of magnitude lower behind the obstacle compared to its front face. For people walking around, the amount of particulate deposited on them and inhaled will depend on their path relative to the cloud, resulting in the counterintuitive result that the closer people may actually not be the ones more at risk because they could simply miss the bulk of the cloud in their wandering. In summary, the long-term cancer risk for people caught in a dirty bomb cloud away from the detonation requires considering where and when the people are, which radionuclide was used, and the layout of the obstacles (e.g., buildings, vegetation) in the path of the cloud.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A prospect for computing in porous materials research: Very large fluid flow simulations

Properties of porous materials, abundant both in nature and industry, have broad influences on societies via, e.g. oil recovery, erosion, and propagation of pollutants. The internal structure of many porous materials involves multiple scales which hinders research on the relation between structure and transport properties: typically laboratory experiments cannot distinguish contributions from individual scales while computer simulations cannot capture multiple scales due to limited capabilities. Thus the question arises how large domain sizes can in fact be simulated with modern computers. This question is here addressed using a realistic test case; it is demonstrated that current computing capabilities allow the direct pore-scale simulation of fluid flow in porous materials using system sizes far beyond what has been previously reported. The achieved system sizes allow the closing of some particular scale gaps in, e.g. soil and petroleum rock research. Specifically, a full steady-state fluid flow simulation in a porous material, represented with an unprecedented resolution for the given sample size, is reported: the simulation is executed on a CPU-based supercomputer and the 3D geometry involves 16,3843 lattice cells (around 590 billion of them are pore sites). Using half of this sample in a benchmark simulation on a GPU-based system, a sustained computational performance of 1.77 PFLOPS is observed. These advances expose new opportunities in porous materials research. The implementation techniques here utilized are standard except for the tailored high-performance data layouts as well as the indirect addressing scheme with a low memory overhead and the truly asynchronous data communication scheme in the case of CPU and GPU code versions, respectively.

Computer Science↗

Exploring performance and energy tradeoffs for irregular applications: A case study on the Tilera many-core architecture

High performance, parallel applications with irregular data accesses are becoming a critical workload class for modern systems. In particular, the execution of such workloads on emerging many-core systems is expected to be a significant component of applications in data mining, machine learning, scientific computing and graph analytics. However, power and energy constraints limit the capabilities of individual cores, memory hierarchy and on-chip interconnect of such systems, thus leading to architectural and software trade-os that must be understood in the context of the intended application’s behavior. Irregular applications are notoriously hard to optimize given their data-dependent access patterns, lack of structured locality and complex data structures and code patterns. We have ported two irregular applications, graph community detection using the Louvain method (Grappolo) and high-performance conjugate gradient (HPCCG), to the Tilera many-core system and have conducted a detailed study of platform-independent and platform-specific optimizations that improve their performance as well as reduce their overall energy consumption. To conduct this study, we employ an auto-tuning based approach that explores the optimization design space along three dimensions - memory layout schemes, GCC compiler flag choices and OpenMP loop scheduling options. We leverage MIT’s OpenTuner auto-tuning framework to explore and recommend energy optimal choices for different combinations of parameters. We then conduct an in-depth architectural characterization to understand the memory behavior of the selected workloads. Finally, we perform a correlation study to demonstrate the interplay between the hardware behavior and application characteristics. Using auto-tuning, we demonstrate whole-node energy savings and performance improvements of up to 49:6% and 60% relative to a baseline instantiation, and up to 31% and 45:4% relative to manually optimized variants.

auto tuning↗

MATAR: A performance portability and productivity implementation of data-oriented design with Kokkos

There is a need for simple, fast, and memory-efficient multidimensional data structures for dense and sparse storage that arise with numerical methods and in software applications. The data structures must perform equally well across multiple computer architectures, including CPUs and GPUs. For this purpose, we developed MATAR, a C++ software library that allows for simple creation and use of intricate data structures that is also portable across disparate architectures using Kokkos. Here, the performance aspect is achieved by forcing contiguous memory layout (or as close to contiguous as possible) for multidimensional and multi-size dense or sparse MATrix and ARray (hence, MATAR) types. Our results show that MATAR has the capability to improve memory utilization, performance, and programmer productivity in scientific computing. This is achieved by fitting more work into the available memory, minimizing memory loads required, and by loading memory in the most efficient order. This document describes the purpose of the work, the implementation of each of the data types, and the resulting performance both in some simple baseline test cases and in an application code.

97 MATHEMATICS AND COMPUTING↗

Experimental design, operation, and results of a 4 kW high temperature steam electrolysis experiment

High temperature steam electrolysis (HTSE) is a promising technology for large-scale hydrogen production. However, research on HTSE performance above the kW level is limited. This paper presents the results of 4 kW HTSE long-term test completed in a multi-kW test facility recently developed at the Idaho National Laboratory (INL). The 4 kW HTSE unit included two solid oxide electrolysis stacks operating in parallel, each of which included 40 electrode-supported planar cells. A current density of 0.41 A/cm2 was used for the long-term operation, resulting in a hydrogen production rate about 25 slpm. A demonstration of 920 hours stable operation was achieved. The paper also includes detailed descriptions of the piping layout, steam generation and delivery system, test fixture, heat recuperation system, hot zone, instrumentation, and operating conditions. As a result, this successful demonstration of multi-kW scale HTSE unit will help to advance the technology toward near-term commercialization.

08 HYDROGEN↗

Load monitoring and compensation strategies for guided-waves based structural health monitoring using piezoelectric transducers

Accurate interpretation of in-situ piezoelectric sensor signals is a challenging task. This article presents the development of a numerical compensation model based on physical insight to address the influence of structural loads on piezo-sensor signals. The model requires knowledge of in-situ strain and temperature distribution in a structure while acquiring sensor signals. The parameters of the numerical model are obtained using experiments on flat aluminum plate under uniaxial tensile loading. It is shown that the model parameters obtained experimentally can be used for different structures, and sensor layout. Furthermore, the combined effects of load and temperature on the piezo-sensor response are also investigated and it is observed that both of these factors have a coupled effect on the sensor signals. It is proposed to obtain compensation model parameters under a range of operating temperatures to address this coupling effect. An important outcome of this study is a new load monitoring concept using in-situ piezoelectric sensor signals to track changes in the load paths in a structure.

environmental compensation↗