Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Parallelized telecom quantum networking with an ytterbium-171 atom array

The integration of quantum computers and sensors into a quantum network enables new capabilities in quantum information science. Most networks with atom-like qubits operate at visible or near-ultraviolet wavelengths and require conversion to the telecom band for long-distance communication, which reduces efficiency and potentially introduces noise. In this article we report high-fidelity entanglement between ytterbium-171 atoms and optical photons generated directly in the telecommunication band, where fibre loss is low. The nuclear spin of the atom is entangled with a single photon in the time-bin basis, yielding a high atom-measurement-corrected atom–photon Bell state fidelity. This can be further improved by addressing photon measurement errors. By imaging the atom array onto an optical fibre array, we also implement a parallelized networking protocol that can increase the remote entanglement rate proportionately with the number of channels. We also preserve coherence on a memory qubit during operations on communication qubits. These results support the integration of atomic systems into scalable quantum networks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Neutron Enigma

Two precision experiments disagree on how long neutrons live before decaying. Does the discrepancy reflect measurement errors or point to some deeper mystery?

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

APOGEE-2S Mg–Al anti-correlation of the metal-poor globular cluster NGC 2298

We present detailed elemental abundances and radial velocities of stars in the metal-poor globular cluster (GC) NGC 2298, based on near-infrared high-resolution ($R$ ~ 22 500) spectra of 12 members obtained during the second phase of the Apache Point Observatory Galactic Evolution Experiment (APOGEE-2) at Las Campanas Observatory as part of the seventeenth Data Release (DR 17) of the Sloan Digital Sky Survey IV (SDSS-IV). We employed the Brussels Automatic Code for Characterizing High accuracy Spectra (BACCHUS) software to investigate abundances for a variety of species including α elements (Mg, Si, and Ca), the odd-Z element Al, and iron-peak elements (Fe and Ni) located in the innermost regions of NGC 2298. We find a mean and median metallicity [Fe/H] = -1.76 and -1.75, respectively, with a star-to-star spread of 0.14 dex, which is compatible with the internal measurement errors. Thus, we find no evidence for an intrinsic [Fe/H] abundance spread in NGC 2298. The typical $α$-element enrichment in NGC 2298 is overabundant relative to the Sun, and it follows the trend of other metal-poor GCs. We confirm the existence of an Al-enhanced population in this cluster, which is clearly anti-correlated with Mg, indicating the prevalence of the multiple-population phenomenon in NGC 2298.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of mix on capsule yields as a function of shell thickness and gas fill

An investigation of direct drive capsules with different shell thicknesses and gas fills was conducted to examine the amount of shock induced (Richtmyer-Meshkov) mix versus Rayleigh-Taylor mix from deceleration of the implosion. The RAGE (Eulerian) code with a turbulent mix model was used to model these capsules for neutron yields along with time-dependent mix amounts. The amount of Richtmyer-Meshkov induced mix from the shock breaking out of the shell is about 0.1 μg (0.15 μm of shell material), while the Rayleigh-Taylor mix is of order 1 μg and determines the mixed simulation yield. The simulations were able to calculate a yield over mix (YOM) ratio (experiment/mix simulation) between 0.5 and 1.0 for capsules with shell thicknesses ranging from 7.5 to 20 μm and with gas fills between 3.8 and 20 atm of D{sub 2} or DT. The simulated burn averaged T{sub ion} values typically lie with 0.5 keV of the data, which is within the measurement error. For capsules with shell thicknesses >25 μm, the YOM values drop to 0.10 ± 0.05, suggesting that some unmodeled effect needs to be accounted for in the thickest capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiparameter measurement utilizing poloidal polarimeter for burning plasma reactor

The authors have made the basic and applied research on the polarimeter for plasma diagnostics. Recently, the authors have proposed an application of multiparameter measurement (magnetic field, B, electron density, n{sub e}, electron temperature, T{sub e}, and total plasma current, I{sub p}) utilizing polarimeter to future fusion reactors. In this proceedings, the brief review of the polarimeter, the principle of the multiparameter measurement and the progress of the research on the multiparameter measurement are explained. The measurement method that the authors have proposed is suitable for the reactor for the following reasons; multiparameters can be obtained from a small number of diagnostics, the proposed method does not depend on time-history, and far-infrared light utilized by the polarimeter is less sensitive to degradation of of optical components. Taking into account the measuring error, performance assessment of the proposed method was carried. Assuming that the error of Δθ and Δε were 0.1° and 0.6°, respectively, the error of reconstructed j{sub φ}, n{sub e} and T{sub e} were 12 %, 8.4 % and 31 %, respectively. This study has shown that the reconstruction error can be decreased by increasing the number of the wavelength of the probing laser and by increasing the number of the viewing chords. For example, By increasing the number of viewing chords to forty-five, the error of j{sub φ}, n{sub e} and T{sub e} were reduced to 4.4 %, 4.4 %, and 17 %, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid monitor for both beam position and tilt of pulsed high-current beams

A Hybrid beam monitor, integrated with both azimuthal and axial B-dot probes, was designed for simultaneous measurement of both beam position and beam angle for pulsed high-current beams at the same location in beam pipe. The output signals of axial B-dot probes were found to be mixed with signals caused by transverse position deviation. In order to eliminate the unwanted signals, an elimination method was developed and its feasibility tested on a 50-Ω coaxial line test stand. By this method, a waveform, shape-like to that of input current and proportional to the tilt angle, was simulated and processed by following integration step to achieve the tilt angle. The tests showed that the measurement error of displacement and tilt angle less than 0.3 mm and 1.5 mrad, respectively. The latter error could be reduced with improved probes by reducing the inductance of the axial B-dot probe, but the improvement reached a limit due to some unknown systemic mechanism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The method for measuring the groove density of variable-line-space gratings with elimination of the eccentricity effect

To eliminate the eccentricity effect, a new method for measuring the groove density of a variable-line-space grating was adapted. Based on grating equation, groove density is calculated by measuring the internal angles between zeroth-order and first-order diffracted light for two different wavelengths with the same angle of incidence. The measurement system mainly includes two laser sources, a phase plate, plane mirror, and charge coupled device. The measurement results of a variable-line-space grating demonstrate that the experiment data agree well with theoretical values, and the value of measurement error (ΔN/N) is less than 2.72 × 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission

Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect measurement of molten steel level in tundish based on laser triangulation

For real-time and precise measurement of molten steel level in tundish during continuous casting, slag level and slag thickness are needed. Among which, the problem of slag thickness measurement has been solved in our previous work. In this paper, a systematic solution for slag level measurement based on laser triangulation is proposed. Being different from traditional laser triangulation, several aspects for measuring precision and robustness have been done. First, laser line is adopted for multi-position measurement to overcome the deficiency of single point laser range finder caused by the uneven surface of the slag. Second, the key parameters, such as installing angle and minimum requirement of the laser power, are analyzed and determined based on the gray-body radiation theory to fulfill the rigorous requirement of measurement accuracy. Third, two kinds of severe noises in the acquired images, which are, respectively, caused by heat radiation and Electro-Magnetic Interference (EMI), are cleaned via morphological characteristic of the liquid slag and color difference between EMI and the laser signals, respectively. Fourth, as false target created by stationary slag usually disorders the measurement, valid signals of the slag are distinguished from the false ones to calculate the slag level. Then, molten steel level is obtained by the slag level minus the slag thickness. The measuring error of this solution is verified by the applications in steel plants, which is ±2.5 mm during steady casting and ±3.2 mm at the end of casting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarimeter for the General Fusion SPECTOR machine

A polarimeter has been designed to measure Faraday rotation and help to understand the profile of its safety factor, q, on the recently built SPECTOR magnetized target fusion machine at General Fusion. The polarimeter uses two counter-rotating, circularly polarized, 118.8 μm beams to probe the plasma. Grad-Shafranov simulations have been used to investigate the effect of measurement error and chord geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beyond optimization—supervised learning applications in relativistic laser-plasma experiments

We explore the applications of machine learning techniques in relativistic laser-plasma experiments beyond optimization purposes. We predict the beam charge of electrons produced in a laser wakefield accelerator given the laser wavefront change caused by a deformable mirror. Machine learning enables feature analysis beyond merely searching for an optimal beam charge, showing that specific aberrations in the laser wavefront are favored in generating higher beam charges. Supervised learning models allow characterizing the measured data quality as well as recognizing irreproducible data and potential outliers. Furthermore, we also include virtual measurement errors in the experimental data to examine the model robustness under these conditions. This work demonstrates how machine learning methods can benefit data analysis and physics interpretation in a highly nonlinear problem of relativistic laser-plasma interaction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thomson scattering on the large plasma device

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper, we describe the diagnostic and its calibration via Raman scattering and present the first measurements performed with the fully commissioned system. Depending on the discharge conditions, the measured densities and temperatures range from 4.0 × 10 12 to 2.8 × 10 13 cm -3 and from 1.2 to 6.8 eV, respectively. The variation of the measurement error with plasma parameters and discharges averaged is also discussed.

47 OTHER INSTRUMENTATION↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

Enhancement of measurement sensitivity in the formation of shear interferograms of transparent plates with small residual wedging

We have proposed a method for increasing the sensitivity of measurements of the wedge angle in transparent plates. The method is based on formation of the holographic shear interferograms using a combination of 180 Degree-Sign rotation of the plate with byturn adjustment of interferograms in its images to an infinitely wide fringe. The sensitivity enhancement is due to the increased number of interference fringes in the observed images of the wedged plate, which favours the reduction of the measurement error during optical processing of the obtained interferograms. Data on the experimental validation of the proposed method are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision loss measurements in short lengths of optical fibre by reflectometry without using Rayleigh scattering

To improve accuracy of light attenuation measurements in optical fibres, especially in short ones, tens and hundreds of metres in length, we propose rejecting a conventional reflectometric approach based on Rayleigh scattering intensity measurements. To this end, we propose for the first time the use of boson peaks in Raman scattering, which, on the one hand, produce no interference effects and no related noise in reflectograms, and, on the other, lie within the C-band. Even at a fibre length as short as 50 m, the attenuation measurement error does not exceed 0.002 dB km{sup −1}. We demonstrate the possibility of compensating for the temperature variation of boson peak intensity by concurrently obtaining a reflectogram for the anti-Stokes line of the fundamental Raman band. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE INTERNAL PROPER MOTIONS OF STARS IN THE OPEN CLUSTER M35

Relative proper motions, based on 108 orbits of Hubble Space Telescope Fine Guidance Sensor data extending from 1992 to 2006, are reported for 74 stars in the open cluster M35 (NGC 2168). A subset of 22 of these objects are then used to compute the cluster's internal proper motion dispersions in both right ascension and declination. We find that these dispersions are equal to within their measurement errors. The average one-dimensional dispersion is 0.018 {+-} 0.002 arcsec century{sup -1}. When combined with the M35 radial velocity dispersion of 0.65 {+-} 0.10 km s{sup -1} found by Geller et al., this produces a cluster distance of 762 {+-} 145 pc. Using isochrone fits to the cluster main sequence, this distance suggests that M35 has an age of about 133 Myr. Although this age is consistent with that typically found for M35, the formal error in the dynamical distance of {+-}19% can accommodate ages between 65 Myr and 201 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

EVOLUTION IN THE VOLUMETRIC TYPE Ia SUPERNOVA RATE FROM THE SUPERNOVA LEGACY SURVEY

We present a measurement of the volumetric Type Ia supernova (SN Ia) rate (SNR{sub Ia}) as a function of redshift for the first four years of data from the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). This analysis includes 286 spectroscopically confirmed and more than 400 additional photometrically identified SNe Ia within the redshift range 0.1 {<=} z {<=} 1.1. The volumetric SNR{sub Ia} evolution is consistent with a rise to z {approx} 1.0 that follows a power law of the form (1+z){sup {alpha}}, with {alpha} = 2.11 {+-} 0.28. This evolutionary trend in the SNLS rates is slightly shallower than that of the cosmic star formation history (SFH) over the same redshift range. We combine the SNLS rate measurements with those from other surveys that complement the SNLS redshift range, and fit various simple SN Ia delay-time distribution (DTD) models to the combined data. A simple power-law model for the DTD (i.e., {proportional_to}t{sup -{beta}}) yields values from {beta} = 0.98 {+-} 0.05 to {beta} = 1.15 {+-} 0.08 depending on the parameterization of the cosmic SFH. A two-component model, where SNR{sub Ia} is dependent on stellar mass (M{sub stellar}) and star formation rate (SFR) as SNR{sub Ia}(z) = A Multiplication-Sign M{sub stellar}(z) + B Multiplication-Sign SFR(z), yields the coefficients A = (1.9 {+-} 0.1) Multiplication-Sign 10{sup -14} SNe yr{sup -1} M{sup -1}{sub Sun} and B = (3.3 {+-} 0.2) Multiplication-Sign 10{sup -4} SNe yr{sup -1} (M{sub Sun} yr{sup -1}){sup -1}. More general two-component models also fit the data well, but single Gaussian or exponential DTDs provide significantly poorer matches. Finally, we split the SNLS sample into two populations by the light-curve width (stretch), and show that the general behavior in the rates of faster-declining SNe Ia (0.8 {<=} s < 1.0) is similar, within our measurement errors, to that of the slower objects (1.0 {<=} s < 1.3) out to z {approx} 0.8.

79 ASTRONOMY AND ASTROPHYSICS↗