Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopic analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Picometer-Precision Atomic Position Tracking through Electron Microscopy

The modern aberration-corrected scanning electron microscopes have successfully achieved direct visualization of atomic columns with sub-angstrom resolution. With this significant progress, advanced image quantification and analysis is still at its early stages. In this work, we present the complete pathway for the metrology of atomic resolution STEM images. This includes: 1) tips for acquiring high-quality STEM images; 2) denoising and drift-correction for enhancing measurement accuracy; 3) obtaining initial atom positions; 4) indexing the atoms based on unit cell vectors; 4) quantifying the atom column positions with either 2D-gaussian single peak fitting or 5) multi-peak fitting routines for slightly overlapping atomic columns; 6) quantification of lattice distortion/strain within the crystal structures or at the defects/interfaces where the lattice periodicity is disrupted, and 7) some common methods to visualize and present the analysis. Furthermore, a simple self-developed free MATLAB app (EASY-STEM) with a graphical user interface (GUI) will be introduced that can help with the analysis of STEM images without the need for writing dedicated analysis code or software. The advanced data analysis methods presented here can be applied for the local quantification of defect relaxations, local structural distortions, local phase transformations, and non-centrosymmetry in a wide range of materials.

47 OTHER INSTRUMENTATION↗

A study of microstructural characteristics of Ni-based superalloys at high temperatures

The microstructural characteristics of the Ni-based superalloy MAR-M245(Hf) which is used in manufacturing the components of the Space Shuttle main engine are studied. These superalloys need optimum heat treatment to get the best results. To find out the optimum heat treatment, the techniques of differential thermal analysis (DTA) and the optical photomicrographs were utilized. In the first phase, the existing experimental equipment like cutting, grinding/polishing machines and metallurgical microscope were set up to cut/polish and take the photomicrographs. In the beginning of the project a Perkin Elmer differential thermal analyzer DTA1700 along with a temperature programmed and the needed computer interface was procured and made operational. In the second year a Leitz Metallux-3 hot state research microscope was also procured and installed for in-situ observation of the superalloy samples. The hot stage when tested for the first time alloyed the thermocouple with the Tantalum heating element and has now been installed. Samples of MAR-M246(Hf), MAR-M247, Waspaloy, Udimet-41, CMSX-3, and CMSX-3 (Polycrystalline and single crystals) were studied using a differential thermal analyzer and the results are reported. Photomicrographs of the Ni-based superalloy MAR-M246 (Hf) were recorded before and after heat treatment at certain temperatures. More heat treatments need to be done before a final inference can be reached.

Lal, Ravindra B.↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Crystallography of Magnetite Plaquettes and their Significance as Asymmetric Catalysts for the Synthesis of Chiral Organics in Carbonaceous Chondrites

We have previously observed the magnetite plaquettes in carbonaceous chondrites using scanning electron microscope (SEM) imaging, examined the crystal orientation of the polished surfaces of magnetite plaquettes in CI Orgueil using electron backscattered diffraction (EBSD) analysis, and concluded that these magnetite plaquettes are likely naturally asymmetric materials. In this study, we expanded our EBSD observation to other magnetite plaquettes in Orgueil, and further examined the internal structure of these remarkable crystals with the use of X-ray computed microtomography.

Chan, Q. H. S.↗

Laboratory Investigation of the Effect of Venusian Weathering on Mineral Spectra

Introduction: The recent selection of two missions to Venus has renewed the importance of deter-mining weathering reactions between minerals and the Venusian atmosphere, and the spectral signatures of minerals before, during, and after these reactions. The rate at which weathering reactions progress also constrain show long unstable minerals will be present on the surface (e.g., [1]), and enables the use of mineralogy as a constraint on surface age(e.g., [2-3]).In order to gain an understanding of how mineral compositions and spectra change with weathering, we have begun conducting experiments in a 1 atm experimental setup at Wesleyan University. This setup exposes minerals to the temperature and most abundant gases of the Venus atmosphere (CO2, SO2, N2).We conducted initial experiments using biotite, calcite, and montmorillonite in order to test our methodology with minerals that may be relevant to recording the history of water on Venus. Methods: Experiments were conducted in Thermo Fisher Scientific Lindberg/Blue M Mini-Mite horizontal tube furnaces at Wesleyan University. Experiments used natural mineral chips and powders, and were conducted at 1 atmosphere and 460 °C under pre-mixed gases provided by Air Gas(Table 1). The furnaces are set up in a flow through configuration so that solid samples are exposed to a fixed gas composition, and quartz glass process tubes were used in all experiments (1/4” diameter for experiment V4, ½” diameter for all others). These conditions were maintained for the du-rations listed in Table 1, at which point the furnace was turned off with gas flowing until the sample was cool enough to extract under N2and be placed in a desiccator for storage. Run products were carbon coated and examined using a Hitachi SU5000 Field Emission Gun Scanning Electron Microscope (SEM) equipped with an EDAX Octane Pro EDS detector located at Wesley-an University. Visible-Near Infrared Spectroscopy (VNIR) analysis was performed on powdered samples under a nitrogen atmosphere using an ASD Fieldspec Proover the 350-2500 nm range. Powdered mineral samples were milled to a particle size of < 45μm and were spiked with an internal standard (Al2O3, corundum) to obtain quantitative mineralogy. Samples were analyzed using a Panalytical X’Pert pro X-ray Diffractometer (XRD), with an X’Celerator high speed detector and Co Kα radiation, with data collected at a step size of 0.02 ̊/minute step counting rate from 2 to 80 degrees 2θ at 45 mA/40kV in the X-ray Diffraction Laboratory located at NASA Johnson Space Center. Materials Data Inc (MDI) software suite, JadeTMv9 was used for Rietveld refinement to determine phase abundances and mineral identification by comparing XRD patterns to International Center for Diffraction Data (ICDD) database patterns. Table 1: Experimental matrix. Experiment Name Duration (Days)Gas Com-position (trace gas)MineralsV487SO2/N2(1.4%)Montmorillonite, biotiteV519SO2/N2(1.4%)CalciteV619CO2/SO2/N2(1.4% SO2, 2.1% N2)Montmorillonite, biotiteV828SO2/N2(1.4%)Biotite, calcite Results: Calcite. In both experiments, calcite was exposed to the SO2/N2gas mixture, and in both experimental run products, XRD analysis detected anhydrite, which is consistent with EDS measurements conducted in the SEM. The XRD analyses show greater amounts of anhydrite present after 28 days than 19, suggesting the calcite reaction progressed further given longer duration. Grain surface morphology as seen in the SEM also shows secondary mineral growth (Fig. 1). VNIR spectra show no change, as expected since anhydrite lacks spectral features in this wavelength range. Montmorillonite. Montmorillonite was exposed to two different gas mixtures, the SO2/N2mix and CO2/SO2/N2mix over different durations (87 and 19 days, respectively). VNIR analyses of both run products show a reduction in the 1441and1910 nm water features as well as a shift of the 1411 and 2011 nm features to shorter wavelengths that may indicate re-structuring in the crystal lattice and the production of amorphous phases [4]. XRD results are consistent with this, showing a shift of the 001 peak from 15Åto 10Åin both run products. The amount of X-ray amorphous material in the montmorillonite run products was greater than that present in the unreacted clay, being the greatest in the 87 day V4 experiment. No other secondary phases were detected in the run products, however sulfur was present in EDS analyses of powder samples.

A R Santos↗

The Multispectral Microscopic Imager: Integrating Microimaging with Spectroscopy for the In-Situ Exploration of the Moon

To maximize the scientific return, future robotic and human missions to the Moon will need to have in-situ capabilities to enable the selection of the highest value samples for returning to Earth, or a lunar base for analysis. In order to accomplish this task efficiently, samples will need to be characterized using a suite of robotic instruments that can provide crucial information about elemental composition, mineralogy, volatiles and ices. Such spatially-correlated data sets, which place mineralogy into a microtextural context, are considered crucial for correct petrogenetic interpretations. . Combining microscopic imaging with visible= nearinfrared reflectance spectroscopy, provides a powerful in-situ approach for obtaining mineralogy within a microtextural context. The approach is non-destructive and requires minimal mechanical sample preparation. This approach provides data sets that are comparable to what geologists routinely acquire in the field, using a hand lens and in the lab using thin section petrography, and provide essential information for interpreting the primary formational processes in rocks and soils as well as the effects of secondary (diagenetic) alteration processes. Such observations lay a foundation for inferring geologic histories and provide "ground truth" for similar instruments on orbiting satellites; they support astronaut EVA activities and provide basic information about the physical properties of soils required for assessing associated health risks, and are basic tools in the exploration for in-situ resources to support human exploration of the Moon.

Nunez, J. I.↗

Revealing the microstructure of materials

The objectives are to demonstrate how the microstructure of materials may be revealed by abrasive polishing and chemical etching, and to illustrate how microstructural information is used to monitor manufacturing processes, provide in-depth inspection, and perform failure analysis. Microstructural analysis is the procedure used to reveal the internal microstructural details of a material or part by sectioning and polishing the cut surface so that it may be examined under a suitable microscope. A printed wiring board was selected as the test material because it contains both metals and nonmetals that have distinctive microstructures, and because this technique is used throughout the electronic industry as a key quality control tool. The three principle component materials in printed circuit boards are glass/epoxy laminates faced with copper foil; copper, deposited by both electroless and electrolytic plating; and tin/lead solder. Sample preparation, mounting, grinding, polishing, and examination and analysis are discussed.

Nelson, James A.↗

Analysis of Extracted Ingredients from Dairy Byproduct Using Dimethyl Ether

Whey permeate is a byproduct created in large quantities from the dairy industry with limited applications due to transportation and stability. Whey permeate is primarily comprised of water, carbohydrates, and minerals with minimal contribution of proteins. Various biomasses in food processing have utilized liquid dimethyl ether (DME) as a form of extraction for high-value ingredients and dewatering. DME is a growing interest in wastewater and biomass treatment due to it being a green solvent, ability to dissolve organic solvents, and miscibility with water. The current study is to determine if DME can effectively dewater whey permeate as well as recover components that can be further used in the food industry as a value-added ingredient. Analysis of the liquid extract and solid extract was evaluated with inductively coupled plasma-mass spectrometry (ICP-MS) and solid extracts were further characterized with the application of a scanning electron microscope (SEM).

09 - BIOMASS FUELS↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Global Microscopic Description of Nucleon-Nucleus Scattering with Quantified Uncertainties

We develop for the first time a microscopic global nucleon-nucleus optical potential with quantified uncertainties suitable for analyzing nuclear reaction experiments at next-generation rare-isotope beam facilities. Within the improved local density approximation and without any adjustable parameters, we begin by computing proton-nucleus and neutron-nucleus optical potentials from a set of five nuclear forces from chiral effective field theory for 1800 target nuclei in the mass range 12 ≤ A ≤ 242 for energies between 0 MeV < E ≲ 150 MeV. We then parameterize a global optical potential for each chiral force that depends smoothly on the projectile energy as well as the target nucleus mass number and isospin asymmetry. Uncertainty bands for elastic scattering observables are generated from a full covariance analysis of the parameters entering in the description of our global optical potential and benchmarked against existing experimental data for stable target nuclei. Since our approach is purely microscopic, we anticipate a similar quality of the model for nucleon scattering on unstable isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of Recombination Losses in CdSe/CdTe Solar Cells from Spectroscopic and Microscopic Time-Resolved Photoluminescence

Due to the lowest-cost and best reliability, CdTe solar cells are the leading thin-film photovoltaic technology. Increasing open-circuit voltage by reducing recombination represents the most promising path toward further improvements. Analysis is needed to identify limitations that cause efficiency losses. To achieve this goal for Cu-doped CdSe/CdTe solar cells, time-resolved spectroscopy and microscopy are developed and applied. Recombination lifetimes and radiative efficiency identify that defect-mediated recombination is the dominant voltage loss mechanism. When carrier lifetimes are averaged over many crystalline grains, they increase from 180 to 430 ns when Al2O3 is applied to the back contact. The quasi-Fermi-level splitting correspondingly increases from 880–905 to 906–931 mV, indicating a pathway to overcome the long-standing 900 mV voltage limitation. However, the dominant recombination losses are attributed to the absorber bulk. From microscopic carrier lifetime measurements, it is identified that space charge fields due to charged grain boundaries (GBs) lead to recombination in the CdTe absorber bulk. At high injection, GB space charge fields are screened, but that occurs above 1 Sun excitation conditions. Alloying with selenium in the near-interface CdSeTe absorber region reduces GB losses and is identified as one of the factors leading to high radiative and power conversion efficiency.

14 SOLAR ENERGY↗

Satellite ocean color measurements

The application of pattern recognition to ocean color data analysis is considered. Due to weight, cost, and data transmission rate limitations, any mapping type remote sensor of ocean color must necessarily collect light from the sea in a finite number of channels. The optical properties of the sea are discussed together with the remote sensing of ocean color, an optical model of natural water, the microscopic optical model, the macroscopic optical model, multiple scattering theory, measurements of subsurface oceanographic parameters, measurements of bulk absorption and scattering properties, measurements of the up- and down-welling light field, and the techniques for ocean color data analysis.

Mccluney, W. R.↗

Utilization of Ultrasonication as a Method of Reducing Organic and Inorganic Contamination in Post‐Consumer Plastic Film Waste

Post-consumer plastic film waste often carries organic and inorganic contaminants that challenge recycling processes and affect the quality of recycled products. An effective contaminant removal procedure through washing such single-used plastic films (SUPFs) can address environmental and waste management concerns. This study compares the efficiency of different washing techniques in reducing SUPF contamination. To evaluate the efficacy of each washing technique, film samples collected from material recovery facilities are individually exposed to friction, ultrasonic-assisted, and a combination of both washes. Thermal analysis indicates that the polymers' melting temperature, crystallization temperature, and crystallinity remain unaffected by the washing methods, demonstrating method aptness. Confocal laser scanning microscope images show that washing results in a cleaner sample surface. 91% ash reduction during the combined wash treatment indicates a high method efficiency compared to the individual friction and ultrasonic wash procedures. This is further validated by reducing characteristic contaminant IR bands (3600–3000, 1750–1600, and 1100–1000 cm −1 ). Elements of concern such as Cd, Cr, Hg, and Pb in SUPFs after each washing technique applied conform with regulations (<100 ppm) for packaging products. This research shows the novel ultrasonic washing reduces more contamination than friction with shorter wash times and no surfactants.

42 ENGINEERING↗

High Throughput Mapping of Single Molecules’ Redox Potentials on Electrode

By synchronizing electrochemical potential scanning with a single-molecule localization super-resolution fluorescence microscope, kinetic fluorescence changes of hundreds of single molecular redox events were tracked simultaneously with high throughput, and subsequent cross-correlation function analysis mapped single molecules’ redox potentials (times) out on the imaging area from site to site in unprecedented detail by extracting electrochemically induced fluorescence change from apparently random fluorescence on/off blinking. This work paves the way toward mapping redox states at single-molecule levels in high throughput in chemical and biological systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disentangling multiple scattering with deep learning: application to strain mapping from electron diffraction patterns

Abstract A fast, robust pipeline for strain mapping of crystalline materials is important for many technological applications. Scanning electron nanodiffraction allows us to calculate strain maps with high accuracy and spatial resolutions, but this technique is limited when the electron beam undergoes multiple scattering. Deep-learning methods have the potential to invert these complex signals, but require a large number of training examples. We implement a Fourier space, complex-valued deep-neural network, FCU-Net, to invert highly nonlinear electron diffraction patterns into the corresponding quantitative structure factor images. FCU-Net was trained using over 200,000 unique simulated dynamical diffraction patterns from different combinations of crystal structures, orientations, thicknesses, and microscope parameters, which are augmented with experimental artifacts. We evaluated FCU-Net against simulated and experimental datasets, where it substantially outperforms conventional analysis methods. Our code, models, and training library are open-source and may be adapted to different diffraction measurement problems.

36 MATERIALS SCIENCE↗

Real-time 3D analysis during electron tomography using tomviz

The demand for high-throughput electron tomography is rapidly increasing in biological and material sciences. However, this 3D imaging technique is computationally bottlenecked by alignment and reconstruction which runs from hours to days. We demonstrate real-time tomography with dynamic 3D tomographic visualization to enable rapid interpretation of specimen structure immediately as data is collected on an electron microscope. Using geometrically complex chiral nanoparticles, we show volumetric interpretation can begin in less than 10 minutes and a high-quality tomogram is available within 30 minutes. Real-time tomography is integrated into tomviz, an open-source and cross-platform 3D data analysis tool that contains intuitive graphical user interfaces (GUI), to enable any scientist to characterize biological and material structure in 3D.

36 MATERIALS SCIENCE↗