Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Development of the Dust Ejecta Radar Technology (DERT) to Determine Plume-Surface Interaction Ejecta Velocities on Planetary Surfaces

Here we present a novel use of millimeter wave doppler radar to measure the velocity of ejecta generated by the impingement of rocket plumes on a planetary surface. The Dust Ejecta Radar Technology (DERT) provides a unique dataset based on direct measurements of ejecta particle velocities during plume-surface interactions. DERT is a continuous wave (CW) 94 GHz radar unit that is being developed at Kennedy Space Center. DERT has measured velocities of a pendulum (~ 1 m/s), a rotating strip (60 m/s), projected regolith simulant BP-1 (~ 250 m/s) and rifle rounds (~ 820 m/s). Signal-to-Noise Ratios of up to 60 dB have been demonstrated. Data collected from DERT will inform the development of high-fidelity computational models of plume-surface interaction effects and will help address NASA Strategic Knowledge Gaps related to characterizing entry, descent and landing effects, and the risks associated with high-speed ejecta on the lander and lunar surface assets.

PSI↗

Development of the Dust Ejecta Radar Technology (DERT) to Determine Plume-Surface Interaction Ejecta Velocities on Planetary Surfaces

Here we present a novel use of millimeter wave doppler radar to measure the velocity of ejecta generated by the impingement of rocket plumes on a planetary surface. The Dust Ejecta Radar Technology (DERT) provides a unique dataset based on direct measurements of ejecta particle velocities during plume-surface interactions. DERT is a continuous wave (CW) 94 GHz radar unit that is being developed at Kennedy Space Center. DERT has measured velocities of a pendulum (~ 1 m/s), a rotating strip (60 m/s), projected regolith simulant BP-1 (~ 250 m/s) and rifle rounds (~ 820 m/s). Signal-to-Noise Ratios of up to 60 dB have been demonstrated. Data collected from DERT will inform the development of high-fidelity computational models of plume-surface interaction effects and will help address NASA Strategic Knowledge Gaps related to characterizing entry, descent and landing effects, and the risks associated with high-speed ejecta on the lander and lunar surface assets.

PSI↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How Much Attenuation Extinguishes mm-Wave Vertically Pointing Radar Return Signals?

Vertically pointing radars (VPRs) operating at millimeter wavelengths measure the power return from raindrops enabling precipitation retrievals as a function of height. However, as the rain rate increases, there are combinations of rain rate and rain path length that produce sufficient attenuation to prevent the radar from detecting raindrops all the way through rain shafts. This study explores the question: Which rain rate and path length combinations completely extinguish radar return signals for VPRs operating between 3 and 200 GHz? An important step in these simulations is converting attenuated radar reflectivity factor into radar received signal-to-noise ratio (SNR) in order to determine the range where the SNR drops below the receiver detection threshold. Configuring the simulations to mimic a U.S. Department of Energy Atmospheric Radiation Mission (ARM) W-band (95 GHz) radar deployed in Brazil, the simulation results indicate that a W-band radar could observe raindrops above 3.5 km only when the rain rate was less than approximately 4 mm h -1 . The deployed W-band radar measurements confirm the simulation results with maximum observed heights ranging between 3 and 4.5 km when a surface disdrometer measured 4 mm h -1 rain rate (based on 25-to-75 percentiles from over 25,000 W-band radar profiles). In summary, this study contributes to our understanding of how rain and atmospheric gas attenuation impacts the performance of millimeter-wave VPRs and will help with the design and configuration of multi-frequency VPRs deployed in future field campaigns.

54 ENVIRONMENTAL SCIENCES↗

The laboratory millimeter- and submillimeter-wave spectrum of CH3OD

The millimeter-wave and submillimeter-wave spectrum of CH3OD, a deuterated isotope of methanol known to be present in the interstellar medium, has been studied in the laboratory. Like all isotopes of methanol, CH3OD possesses a complex dense spectrum because of the phenomenon of internal rotation, sometimes referred to as torsional motion. Approximately 300 lines in the frequency range 130-700 GHz have been assigned. These lines involve transitions between rotational states with rotational quantum number J of not greater than 9 in both the A and the E substates of the lowest torsional state (v sub t = 0). The present data and previous data at lower frequencies (longer wavelengths) have been combined and analyzed by a procedure called the 'internal axis method'. The analysis yields spectral constants for CH3OD which, in turn, have been used to predict the frequencies of a number of other transitions of this species not measured in the laboratory.

Anderson, Todd↗

Remote sensing science for the Nineties; Proceedings of IGARSS '90 - 10th Annual International Geoscience and Remote Sensing Symposium, University of Maryland, College Park, May 20-24, 1990. Vols. 1, 2, & 3

Various papers on remote sensing (RS) for the nineties are presented. The general topics addressed include: subsurface methods, radar scattering, oceanography, microwave models, atmospheric correction, passive microwave systems, RS in tropical forests, moderate resolution land analysis, SAR geometry and SNR improvement, image analysis, inversion and signal processing for geoscience, surface scattering, rain measurements, sensor calibration, wind measurements, terrestrial ecology, agriculture, geometric registration, subsurface sediment geology, radar modulation mechanisms, radar ocean scattering, SAR calibration, airborne radar systems, water vapor retrieval, forest ecosystem dynamics, land analysis, multisensor data fusion. Also considered are: geologic RS, RS sensor optical measurements, RS of snow, temperature retrieval, vegetation structure, global change, artificial intelligence, SAR processing techniques, geologic RS field experiment, stochastic modeling, topography and Digital Elevation model, SAR ocean waves, spaceborne lidar and optical, sea ice field measurements, millimeter waves, advanced spectroscopy, spatial analysis and data compression, SAR polarimetry techniques. Also discussed are: plant canopy modeling, optical RS techniques, optical and IR oceanography, soil moisture, sea ice back scattering, lightning cloud measurements, spatial textural analysis, SAR systems and techniques, active microwave sensing, lidar and optical, radar scatterometry, RS of estuaries, vegetation modeling, RS systems, EOS/SAR Alaska, applications for developing countries, SAR speckle and texture.

Source record↗

A Submillimeter Wave SIS Receiver for 547 GHz

The most sensitive heterodyne receivers used for millimeter wave and submillimeter wave radioastronomy employ superconductor-insulator-superconductor tunnel junctions as the nonlinear mixing element.

heterodyne receivers submillimeter wave SIS tunnel↗

Submillimeter-Wave Amplifier Module with Integrated Waveguide Transitions

To increase the usefulness of monolithic millimeter-wave integrated circuit (MMIC) components at submillimeter-wave frequencies, a chip has been designed that incorporates two integrated, radial E-plane probes with an MMIC amplifier in between, thus creating a fully integrated waveguide module. The integrated amplifier chip has been fabricated in 35-nm gate length InP high-electron-mobility-transistor (HEMT) technology. The radial probes were mated to grounded coplanar waveguide input and output lines in the internal amplifier. The total length of the internal HEMT amplifier is 550 m, while the total integrated chip length is 1,085 m. The chip thickness is 50 m with the chip width being 320 m. The internal MMIC amplifier is biased through wire-bond connections to the gates and drains of the chip. The chip has 3 stages, employing 35-nm gate length transistors in each stage. Wire bonds from the DC drain and gate pads are connected to off-chip shunt 51-pF capacitors, and additional off-chip capacitors and resistors are added to the gate and drain bias lines for low-frequency stability of the amplifier. Additionally, bond wires to the grounded coplanar waveguide pads at the RF input and output of the internal amplifier are added to ensure good ground connections to the waveguide package. The S-parameters of the module, not corrected for input or output waveguide loss, are measured at the waveguide flange edges. The amplifier module has over 10 dB of gain from 290 to 330 GHz, with a peak gain of over 14 dB at 307 GHz. The WR2.2 waveguide cutoff is again observed at 268 GHz. The module is biased at a drain current of 27 mA, a drain voltage of 1.24 V, and a gate voltage of +0.21 V. Return loss of the module is very good between 5 to 25 dB. This result illustrates the usefulness of the integrated radial probe transition, and the wide (over 10-percent) bandwidth that one can expect for amplifier modules with integrated radial probes in the submillimeter-regime (>300 GHz).

Samoska, Lorene↗

The Atacama Cosmology Telescope: arcminute-resolution maps of 18 000 square degrees of the microwave sky from ACT 2008–2018 data combined with Planck

This paper presents a maximum-likelihood algorithm for combining sky maps with disparate sky coverage, angular resolution and spatially varying anisotropic noise into a single map of the sky. We use this to merge hundreds of individual maps covering the 2008–2018 ACT observing seasons, resulting in by far the deepest ACT maps released so far. We also combine the maps with the full Planck maps, resulting in maps that have the best features of both Planck and ACT: Planck’s nearly white noise on intermediate and large angular scales and ACT’s high-resolution and sensitivity on small angular scales. The maps cover over 18 000 square degrees, nearly half the full sky, at 100, 150 and 220 GHz. Furthermore, they reveal 4 000 optically-confirmed clusters through the Sunyaev Zel’dovich effect (SZ) and 18 500 point source candidates at > 5σ, the largest single collection of SZ clusters and millimeter wave sources to date. The multi-frequency maps provide millimeter images of nearby galaxies and individual Milky Way nebulae, and even clear detections of several nearby stars. Other anticipated uses of these maps include, for example, thermal SZ and kinematic SZ cluster stacking, CMB cluster lensing and galactic dust science. The method itself has negligible bias. However, due to the preliminary nature of some of the component data sets, we caution that these maps should not be used for precision cosmological analysis. The maps are part of ACT DR5, and will be made available on LAMBDA no later than three months after the journal publication of this article, along with an interactive sky atlas.

79 ASTRONOMY AND ASTROPHYSICS↗

The molecular spiral arms of NGC 6946

High resolution observations of molecules in external galaxies are essential to understanding physical processes leading to the formation of stars. One question is whether there is a spiral structure in the molecular gas, but it was not possible to resolve the spiral arms of external galaxies until the advent of large millimeter-wave telescopes. With the Institute for Radio Astronomy in the Millimeter Range (IRAM) 30 m telescope, researchers are carrying through the mapping of NGC 6946 in the CO-12(1-0) and (2-1) lines. This galaxy is a large, gas-rich Scd spiral with a strong star formation activity. NGC 6946 is well studied at radio and optical wavelengths, so that it is possible to compare the location of the spiral arms tracers: HI ridge, HII regions and molecular clouds. The disk CO emission is very contrasted (no lines for some positions, 1 K in CO(1-0) for some others) and correlated with the optical spiral arms: this clearly shows up in a figure which presents superimposed contours of CO(2-1) integrated emissivity and of H alpha line emission. The agreement is very good, and there is no displacement across the arm between the CO, HI and H alpha ridges of emission. The arms are barely resolved by the 23 inch beam and the molecular contrast averaged over the map is about 4. The CO(2-1) maxima are closer to the position of the HII regions than those of CO(1-0), which could be due to variations of excitation conditions. The CO excitation in the disk of NGC 6946 is low: when all data are convolved to the same resolution of 23 inches the CO(2-1) lines are about 0.45 times fainter than the CO(1-0) ones, while in the nucleus they have roughly the same intensity. This suggests that in the disk of NGC 6946 most of the CO emission comes from cold optically thick gas located in cloud envelopes rather than from cloud cores. The molecular and atomic component in the observed regions of NGC 6946 seems to be organized in large gaseous complexes.

Casoli, F.↗

Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz

Future remote sensing instruments will require focal plane spectrometer arrays with higher resolution at high frequencies. One of the major components of spectrometers are the local oscillator (LO) signal sources that are used to drive mixers to down-convert received radio-frequency (RF) signals to intermediate frequencies (IFs) for analysis. By advancing LO technology through increasing output power and efficiency, and reducing component size, these advances will improve performance and simplify architecture of spectrometer array systems. W-band power amplifiers (PAs) are an essential element of current frequency-multiplied submillimeter-wave LO signal sources. This work utilizes GaN monolithic millimeter-wave integrated circuit (MMIC) PAs developed from a new HRL Laboratories LLC 0.15- m gate length GaN semiconductor transistor. By additionally waveguide power combining PA MMIC modules, the researchers here target the highest output power performance and efficiency in the smallest volume achievable for W-band.

Fung, King Man↗

The Atacama Cosmology Telescope: arcminute-resolution maps of 18,000 square degrees of the microwave sky from ACT 2008-2018 data combined with Planck

This paper presents a maximum-likelihood algorithm for combining sky maps with disparate sky coverage, angular resolution and spatially varying anisotropic noise into a single map of the sky. We use this to merge hundreds of individual maps covering the 2008–2018 ACT observing seasons, resulting in by far the deepest ACT maps released so far. We also combine the maps with the full Planck maps, resulting in maps that have the best features of both Planck and ACT: Planck’s nearly white noise on intermediate and large angular scales and ACT’s high-resolution and sensitivity on small angular scales. The maps cover over 18 000 square degrees, nearly half the full sky, at 100, 150 and 220 GHz. They reveal 4 000 optically-confirmed clusters through the Sunyaev Zel’dovich effect (SZ) and 18 500 point source candidates at > 5σ, the largest single collection of SZ clusters and millimeter wave sources to date. The multi-frequency maps provide millimeter images of nearby galaxies and individual Milky Way nebulae, and even clear detections of several nearby stars. Other anticipated uses of these maps include, for example, thermal SZ and kinematic SZ cluster stacking, CMB cluster lensing and galactic dust science. The method itself has negligible bias. However, due to the preliminary nature of some of the component data sets, we caution that these maps should not be used for precision cosmological analysis. The maps are part of ACT DR5, and will be made available on LAMBDA no later than three months after the journal publication of this article, along with an interactive sky atlas.

Sigurd Naess↗

Power Amplifier Module with 734-mW Continuous Wave Output Power

Research findings were reported from an investigation of new gallium nitride (GaN) monolithic millimeter-wave integrated circuit (MMIC) power amplifiers (PAs) targeting the highest output power and the highest efficiency for class-A operation in W-band (75-110 GHz). W-band PAs are a major component of many frequency multiplied submillimeter-wave LO signal sources. For spectrometer arrays, substantial W-band power is required due to the passive lossy frequency multipliers-to generate higher frequency signals in nonlinear Schottky diode-based LO sources. By advancing PA technology, the LO system performance can be increased with possible cost reductions compared to current GaAs PAs. High-power, high-efficiency GaN PAs are cross-cutting and can enable more efficient local oscillator distribution systems for new astrophysics and planetary receivers and heterodyne array instruments. It can also allow for a new, electronically scannable solid-state array technology for future Earth science radar instruments and communications platforms.

Fung, King Man↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Status of the PAPPA experiment

The Primordial Anisotropy Polarization Pathfinder Array (PAPPA) is a balloonborne instrument to measure the polarization of the cosmic microwave background and search for the signature of primordial gravity waves. PAPPA uses a novel marriage of RF phase modulation and millimeter-wave bolometric detectors to produce a "polarimeter-on-a-chip" capable of simultaneously measuring the Stokes I, Q, and U parameters on the sky. I will discuss the current status and future plans for PAPPA.

Kogut, Alan↗

Integrated 222-GHz corner-reflector antennas

A high-gain monolithic millimeter-wave antenna has been designed, fabricated, and tested at 222 GHz. The structure consists of a traveling-wave antenna integrated on a 1.2-micron dielectric membrane and suspended in a longitudinal cavity etched in a silicon wafer. A new traveling-wave antenna design yields a wideband input impedance and a low cross-polarization component in the E- and quasi-H-plane patterns. A directivity of 17.7 dB and a main-beam efficiency of 88.5 percent are calculated from the 222-GHz pattern measurements. The integrated corner-reflector antenna is well suited for millimeter- and submillimeter-wave imaging applications in large f-number systems.

Gearhart, Steven S.↗