Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

FPGA-based Upgrade to RITS-6 Control System, Designed with EMP Considerations

The existing control system for the RITS-6, a 20-MA 3-MV pulsed-power accelerator located at Sandia National Laboratories, was built as a system of analog switches because the operators needed to be close enough to the machine to hear pulsed-power breakdowns, yet the electromagnetic pulse (EMP) emitted would disable any processor-based solutions. The resulting system requires operators to activate and deactivate a series of 110-V relays manually in a complex order. The machine is sensitive to both the order of operation and the time taken between steps. A mistake in either case would cause a misfire and possible machine damage. Based on these constraints, a field-programmable gate array (FPGA) was chosen as the core of a proposed upgrade to the control system. An FPGA is a series of logic elements connected during programming. Based on their connections, the elements can mimic primitive logic elements, a process called synthesis. The circuit is static; all paths exist simultaneously and do not depend on a processor. This should make it less sensitive to EMP. By shielding it and using good electromagnetic interference-reduction practices, it should continue to operate well in the electrically noisy environment. The FPGA has two advantages over the existing system. In manual operation mode, the synthesized logic gates keep the operators in sequence. In addition, a clock signal and synthesized countdown circuit provides an automated sequence, with adjustable delays, for quickly executing the time-critical portions of charging and firing. The FPGA is modeled as a set of states, each state being a unique set of values for the output signals. The state is determined by the input signals, and in the automated segment by the value of the synthesized countdown timer, with the default mode placing the system in a safe configuration. Unlike a processor-based system, any system stimulus that results in an abort situation immediately executes a shutdown, with only a tens-of-nanoseconds delay to propagate across the FPGA. This paper discusses the design, installation, and testing of the proposed system upgrade, including failure statistics and modifications to the original design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of EMP generation using a Lienard-Wiechert formulation, and progress toward a 3-D EMP code

Here, we describe studies of the generation of electro-magnetic pulse (EMP) fields under the idealized conditions of a delta-function gamma pulse, a spherical cap of Compton electrons located at a common radius from the burst, and the absence of the conduction current. Various processes (geomagnetic rotation, drag, and scattering) contribute to the time derivative of the Compton current density, which appears as the source term in the Lienard–Wiechert expression for the radiation field. These processes are considered separately and in combination, and their influences on the waveform of the EMP assessed. Using a separate computational approach, different numerical models of multiple scattering are tested, in an effort to assess the validity of existing codes and earlier results. We also describe plans for and progress toward a comprehensive 3-D EMP code, which is to employ recently developed numerical methods and is to offer a variety of models, including the Lienard–Wiechert formulation described here.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mg-Ion Conduction in Antiperovskite Solid Electrolytes Revealed by 25 Mg Ultrahigh Field NMR and First-Principles Calculations

Magnesium-ion batteries hold the potential to outperform the energy density of lithium-ion batteries, given the divalent charge carried by each Mg 2+ cation, but remain in an early stage of development. Here, in this study, 25 Mg solid-state nuclear magnetic resonance (ssNMR) is used to gain insight into the local structure and Mg-ion dynamics of candidate Mg-ion solid electrolytes, the antiperovskites Mg 3 SbN and Mg 3 AsN. Using the highest available magnetic field (35.2 T) for high-resolution solid-state NMR, the largest 25 Mg quadrupole coupling constants (C Q ) yet measured of up to 22 MHz are reported and corroborated by first-principles calculations. Predicted C Q values are shown to correlate with the antiperovskite’s tolerance factor; thus, 25 Mg NMR linewidths can report on lattice distortions and phase stability of these antiperovskites. Variable-temperature 25 Mg NMR spectra demonstrate changes at elevated temperatures, ascribed to Mg-ion motional effects. 25 Mg T 1 relaxometry measurements at ultrahigh field reveal a lower activation energy for the more distorted Mg 3 AsN phase, matching computational predictions of a lower energy barrier for Mg 2+ ion migration and suggesting that additional scrutiny of antiperovskites as Mg-ion conductors is warranted. Given the inherent challenges of 25 Mg NMR, this work demonstrates the benefits of combining ultrahigh field NMR spectroscopy, advanced pulse sequences, modern signal processing, and first-principles calculations to facilitate NMR of quadrupolar nuclei as a tool to probe the local structure and ion dynamics in beyond-Li battery materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

On a framework for generating PoD curves assisted by numerical simulations

The Probability of Detection (PoD) curve method has emerged as an important tool for the assessment of the performance of NDE techniques, a topic of particular interest to the nuclear industry where inspection qualification is very important. The conventional experimental means of generating PoD curves though, can be expensive, requiring large data sets (covering defects and test conditions), and equipment and operator time. Several methods of achieving faster estimates for PoD curves using physics-based modelling have been developed to address this problem. Numerical modelling techniques are also attractive, especially given the ever-increasing computational power available to scientists today. Here we develop procedures for obtaining PoD curves, assisted by numerical simulation and based on Bayesian statistics. Numerical simulations are performed using Finite Element analysis for factors that are assumed to be independent, random and normally distributed. PoD curves so generated are compared with experiments on austenitic stainless steel (SS) plates with artificially created notches. We examine issues affecting the PoD curve generation process including codes, standards, distribution of defect parameters and the choice of the noise threshold. We also study the assumption of normal distribution for signal response parameters and consider strategies for dealing with data that may be more complex or sparse to justify this. These topics are addressed and illustrated through the example case of generation of PoD curves for pulse-echo ultrasonic inspection of vertical surface-breaking cracks in SS plates.

36 MATERIALS SCIENCE↗

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon-13 NMR spectra of lignin isolated from field grown transgenic poplar

Here we present a curated dataset of a series of 13C nuclear magnetic resonance (NMR) spectra of lignin isolated from transgenic monolignol 4-O-methyltransferase (MOMT4) engineered poplar. The transgenic poplar was collected from a 3-year field trial experiment. The poplar was Soxhlet-extracted with toluene/ethanol and the extractives-free poplar was then ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h. The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96:4 (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover the lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide for NMR characterization. 13C experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence (zgpg) on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following conditions: spectra width 229 ppm, 64k data points, 1s pulse delay, and 6k scans. All the data was processed using the Bruker’s TopSpin 3.6 software. Additional meta data is embedded in the raw spectra files.

13C NMR, lignin, poplar, field trial, MOMT4, CBI↗

Light control of intramolecular nuclear dynamics by vortex electron localization

In strong-field ionization of molecules, intense light pulses are thought to have a negligible direct influence on atomic nuclei. Molecular dissociation is thus expected to be determined by the geometrical configuration of the molecular ion at the ionization instant. Contrary to this picture, we observe a counterintuitive electron-proton angular correlation and the formation of proton vortices following strong-field ionization of H 2 molecules by bicircularly polarized two-color laser fields. We explain this phenomenon by the pathway interference and localization of the residual H 2 ⁡+ electron in different angular-momentum states formed in the tail of the driving laser pulse. We validate this interpretation by combining a quantum-mechanical numerical simulation of the field-driven coupled electronic-nuclear dynamics and a semiclassical-trajectory model for the phase accumulation of the laser-driven electronic-nuclear wave packet. Our joint experimental and theoretical study reveals a general picture of vortex electron localization which can be used for controlling molecular-bond breaking with circularly polarized laser fields.

Atomic & molecular processes in external fields↗

A high-efficiency, low-Ĉerenkov Micro-Layered Fast-Neutron Detector for the $\mathrm{TREAT}$ hodoscope

Here this paper presents an enabling technology for high-efficiency fast-neutron detection for the Transient Reactor Test (TREAT) Facility hodoscope. The hodoscope is currently outfitted with 25.4-mm long Hornyak buttons for fast-neutron detection. However, they require improvements, as they suffer from low detection efficiency, Ĉerenkov radiation contaminating the signal, and non-linearity of detector response at large transients. To address these issues, a layered ZnS:Ag device has been constructed. The layered design provides various advantages: it incorporates greater scintillation volume, Ĉerenkov background is significantly reduced by eliminating the need for additional light guides, and the detection process is simplified by achieving gamma-ray rejection using only pulse-height discrimination. The result is a greater number of fast neutron counts with reduced background noise contaminating the signal. On being irradiated with a 252Cf source (whose neutron energy spectrum closely mimics a reactor fission spectrum), a 25.4-mm long layered device was found to exhibit an intrinsic fast-neutron detection efficiency of 8.1% for neutrons with an average energy of 2 MeV, while a 43-mm long device allows for a greater number of fast neutron to be detected, increasing the efficiency to 9.1%. Further lengthening of the device up to 20 cm has been numerically predicted to exhibit even higher efficiencies. The detectors can be mass-produced easily and inexpensively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser

Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray pulses and solid targets (metals and their deuterides) at the FLASH free-electron laser where power densities exceeding 10{sup 17} W/cm{sup 2} were reached. Time-of-flight ion spectrometry and crater analysis were used to characterize the interaction. The results show the onset of saturation in the ablation process at power densities above 10{sup 16} W/cm{sup 2}. This effect can be linked to a transiently induced x-ray transparency in the solid by the femtosecond x-ray pulse at high power densities. The measured kinetic energies of protons and deuterons ejected from the surface reach several keV and concur with predictions from plasma-expansion models. Simulations of the interactions were performed with a nonlocal thermodynamic equilibrium code with radiation transfer. These calculations return critical depths similar to the observed crater depths and capture the transient surface transparency at higher power densities.

36 MATERIALS SCIENCE↗

Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations and Lessons Learned from Testing of the Hanford Waste Treatment Plant Standard High Solids Vessel Design - 18635

The Hanford Waste Treatment and Immobilization Plant (WTP) recently completed qualification testing of the mixing system for the standard high solids vessel design the U.S. Department of Energy (DOE) proposed to replace several vessels in the design of the plant Pretreatment Facility. Testing was split into two phases. The first phase exercised the pulse jet mixer control system to ensure that the control software could accommodate fluids across the complete range of expected densities and viscosities within the vessel for all operational modes. The second phase of testing was focused on the mixing performance of the vessel, specifically, whether mixing was adequate to support the transfer, de-inventory, throughput, and sampling functions of the vessel. Key observations and lessons learned from testing include: - Successful transfer of waste within and beyond the design basis slurry solids concentration; - Successful resuspension and transfer of large, heavy particles; - Effective performance of multi-level bubblers for process control and monitoring; - Effective controls performance; - Reduction of sparger flowrate from nominal design flow; - Liquid blending within about 15 minutes; - Insights into sample representativeness and uniformity of transfers to inform process control strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The stellar origins of 96 Zr excesses in presolar graphites from the Murchison meteorite

Context. Zirconium-96 is a stable isotope that can be synthesized under different neutron-rich nucleosynthetic conditions. Astrophysical models predict its production to occur in various stellar environments: from low-to-intermediate-mass asymptotic giant branch (AGB) stars to massive stars and core-collapse supernovae. Aims. Detections of 96Zr excesses, in combination with other isotopic measurements from presolar grains can provide unique constraints on its stellar origin. Presolar grains are microscopic particles found in primitive Solar System materials, which formed in stellar winds and supernova ejecta. The isotopic composition of each grain can provide us a snapshot of the nucleosynthetic processes that took place during the parent star’s lifetime. Methods. In this study, we measured the stable isotopes of C, N, O, Mo, Zr, and Ru in high-density presolar graphite grains from the Murchison meteorite and found four grains that contain positive isotopic anomalies in 96 Zr carried by their internal subgrains. We analyzed multi-element isotopic datasets from each grain to explore the source of the observed 96 Zr excesses. Results. Comparisons with stellar models indicate that two grains likely condensed in an intermediate-mass AGB star with initial metallicity of Z ≤ 0.014. Their 96 Zr/ 94 Zr ratios also match those predicted for born-again AGB stars undergoing a very late thermal pulse and rapidly accreting white dwarfs. After comparing the relative populations of the aforementioned dust-producing stars, we propose rapidly accreting white dwarfs as a new, and more likely, stellar source for one of the presolar grains. The remaining two grains could have originated in the supernova ejecta of massive stars, due to correlated excesses in the p-nuclides, 92, 94 Mo. Thus, grains with 96 Zr anomalies can have a variety of stellar origins, in agreement with theoretical studies. Conclusions. Our study highlights the importance of multi-element analysis in constraining the types of stars where presolar grains have condensed. These data will help improve our understanding of various nucleosynthesis processes in different stellar phases.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of polarizers for a mega-watt long-pulse millimeter-wave transmission line on the large helical device

The polarizer is one of the critical components in a high-power millimeter-wave transmission line. It requires full and highly efficient coverage of any polarization states, high-power tolerance, and low-loss feature. Polarizers with rounded shape at the edge of the periodic groove surface are designed and fabricated by the machining process for a mega-watt long-pulse millimeter-wave transmission line of the electron cyclotron resonance heating system in the large helical device. The groove shape of λ/8- and λ/4-type polarizers for an 82.7 GHz transmission line is optimally designed in an integral method developed in the vector theories of diffraction gratings so that the efficiency to realize any polarization state can be maximized. The dependence of the polarization states on the combination of the two polarizer rotation angles (Φ{sub λ/8}, Φ{sub λ/4}) is examined experimentally in a low-power test with the newly developed polarization monitor. The results show that the measured polarization characteristics are in good agreement with the calculated ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical Refinement of the GADRAS Detector Response Function

The Gamma Detector Response and Analysis Software (GADRAS) was augmented to enable empirical refinement of the Detector Response Function (DRF) for gamma-ray detectors. This capability is included in GADRAS starting with Version 18.8.2, which was released in February 2019 Empirical refinement enables improved computational accuracy for gamma-ray spectra when detectors exhibit characteristics that are essentially unique to a particular sensor. This report discusses how to perform the empirical refinement, and examples are presented for the following scenarios where empirical refinement is appropriate: Large plastic scintillators, which are generally composed of polyvinyl toluene (PVT), often exhibit low-energy peaks that are not associated with incident gamma rays. Regardless of whether they are artifacts produced by poor light collection or pulse processing methods, accurate spectral synthesis requires replication of these features; Some detectors, particularly those using Silicon Photomultipliers (SiPM), exhibit energy shifts of Compton edges and escape peaks relative to the same scintillator material attached to a photomultiplier tube. Empirical refinement compensates for these effects, which derive from nonlinearities in the detector response; The change in the DRF as a function of displacement of the source relative to the detector axis cannot always be replicated adequately using only the few shielding parameters that are used by the response function. Empirical refinement enables improved accuracy for computation of spectra during linear transits or when the detector is close to a large radiation source. This is a particularly important consideration for collimated detectors; and, Gamma-ray imagers exhibit complex relationships between spectral response and spatial locations. Empirical refinement enables substantial improvement of the DRF accuracy for imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate activity determination of a californium neutron source

Accurately counting analog events requires constructing an electronics chain that produces one count for each input pulse. Here, in this work, we review the use of Nuclear Instrumentation Module electronic units for counting neutron capture events in a 3He tube. We identify two unique types of false trigger events in a leading-edge discriminator and show how a dual timer module can be used to produce a veto window to exclude these events. We use the constructed electronics chain to build an apparatus to measure neutron pulses from a 252 Cf neutron source. We compare the measurements with a Monte Carlo N-Particle (MCNP) model to determine the activity of the neutron source. Furthermore, by making additional measurements with borated polyethylene attenuators between the source and detector, we are able to determine the boron concentration of the polyethylene. This technique provides accurate determination of the source activity to a precision of 2.8% at the k=1 level. The method used is simple, inexpensive, and requires no additional calibrated instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18C-07: Hardware Advances for MTF Improvement in Dedicated Breast CT

Purpose: In this study, we have designed and implemented a prototype dedicated breast CT system (bCT) to improve the spatial resolution characteristics, in order to improve detection of micro-calcifications. Methods: A 10.8 kW water-cooled, tungsten anode x-ray tube, running up to 240 mA at 60 kV, coupled with an x-ray generator specifically designed for this application, and 0.3 mm of added copper filter was used to generate x-ray pulses. A CsI CMOS flat panel detector with a pixel pitch of 0.075 mm in native binning mode was used. The system geometry was designed in a way to achieve an FOV on par with similar bCT prototypes, resulting in a magnification factor of 1.39. A 0.013 mm tungsten wire was used to generate point spread functions. Multiple scans were performed with different numbers of projections, different reconstruction kernel sizes and different reconstruction filters to study the effects of each parameter on MTF. The resulting MTFs were then evaluated quantitatively using the generated PFSs. Duplicate scans with the same parameters were performed on two other dedicated breast CT systems to compare the performance of the new prototype. Results: The results of the MTF experiments demonstrate a significant improvement in the spatial resolution characteristics. In the new prototype, using the pulsed x-ray source results in a restoration of the azimuthal MTF degradation, due to motion blurring previously seen in other bCT systems. Moreover, employing the higher resolution x-ray detector considerably improves the MTF. The MTF at 10% of the new system is at 3.5 1/mm, a factor of 4.36 greater than an earlier bCT scanner. Conclusion: The MTF analysis of the new prototype bCT shows that using the new hardware and control results in a significant improvement in visualization of finer detail. This suggests that the visualization of micro-calcifications will be significantly improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of dynamic displacement current for diagnostics of subnanosecond breakdowns in an inhomogeneous electric field

The breakdown of different air gaps at high overvoltages in an inhomogeneous electric field was investigated with a time resolution of up to 100 ps. Dynamic displacement current was used for diagnostics of ionization processes between the ionization wave front and a plane anode. It is demonstrated that during the generation of a supershort avalanche electron beam (SAEB) with amplitudes of {approx}10 A and more, conductivity in the air gaps at the breakdown stage is ensured by the ionization wave, whose front propagates from the electrode of small curvature radius, and by the dynamic displacement current between the ionization wave front and the plane electrode. The amplitude of the dynamic displacement current measured by a current shunt is 100 times greater than the SAEB. It is shown that with small gaps and with a large cathode diameter, the amplitude of the dynamic displacement current during a subnanosecond rise time of applied pulse voltage can be higher than 4 kA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗