Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

An EGSnrc Monte Carlo-calculated database of TG-43 parameters

Monte Carlo methods are used to calculate a complete TG-43 dosimetry parameter data set for 27 low-energy photon emitting brachytherapy sources (18 {sup 125}I and 9 {sup 103}Pd). All Monte Carlo calculations are performed using the EGSnrc user-code BrachyDose. TG-43 dosimetry parameters, including dose rate constants, radial dose functions (with functional fitting parameters), and anisotropy data, are calculated with finer spatial resolution, greater range of distances, and smaller uncertainties than data currently available in the literature for many of these sources. In particular, for most of the seeds, this is the first time that anisotropy data have been tabulated at distances less than 0.5 cm from the source. These calculations employ the state-of-the-art XCOM photon cross sections, and detailed source geometries are modeled using Yegin's multigeometry package. This data set serves as a completely independent verification of the currently available dosimetry parameters calculated using other Monte Carlo codes, including MCNP and PTRAN. This report also describes the Carleton Laboratory for Radiotherapy Physics TG-43 Parameter Database, a publicly accessible web site (at http://www.physics.carleton.ca/clrp/seed{sub d}atabase/) through which all of the data calculated for this study can be accessed. Also available on the web site are descriptions of the methods and Monte Carlo models used in this study and comparisons of data calculated in this study with data calculated by other authors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative analysis of beam delivery parameters and treatment process time for proton beam therapy

Purpose: To evaluate patient census, equipment clinical availability, maximum daily treatment capacity, use factor for major beam delivery parameters, and treatment process time for actual treatments delivered by proton therapy systems. Methods: The authors have been recording all beam delivery parameters, including delivered dose, energy, range, spread-out Bragg peak widths, gantry angles, and couch angles for every treatment field in an electronic medical record system. We analyzed delivery system downtimes that had been recorded for every equipment failure and associated incidents. These data were used to evaluate the use factor of beam delivery parameters, the size of the patient census, and the equipment clinical availability of the facility. The duration of each treatment session from patient walk-in and to patient walk-out of the treatment room was measured for 82 patients with cancers at various sites. Results: The yearly average equipment clinical availability in the last 3 yrs (June 2007-August 2010) was 97%, which exceeded the target of 95%. Approximately 2200 patients had been treated as of August 2010. The major disease sites were genitourinary (49%), thoracic (25%), central nervous system (22%), and gastrointestinal (2%). Beams have been delivered in approximately 8300 treatment fields. The use factor for six beam delivery parameters was also evaluated. Analysis of the treatment process times indicated that approximately 80% of this time was spent for patient and equipment setup. The other 20% was spent waiting for beam delivery and beam on. The total treatment process time can be expressed by a quadratic polynomial of the number of fields per session. The maximum daily treatment capacity of our facility using the current treatment processes was estimated to be 133 {+-} 35 patients. Conclusions: This analysis shows that the facility has operated at a high performance level and has treated a large number of patients with a variety of diseases. The use factor of beam delivery parameters varies by disease site. Further improvements in efficiency may be realized in the equipment- and patient-related processes of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-95: Personalized Radiography Technical Parameters for Each Patient and Exam

Purpose: To determine exact electrical parameters (kV, mAs) a radiological technologist shall use taking account the exam and patient's structure, with guarantee of minimum dose and adequate quality image. Methods: A patient's absorbed dose equation was developed by means of Entrance Skin Dose (ESD), irradiated area and patient width for specific anatomy. ESD is calculated from a developed equation, where entrance surface air-KERMA and backscatter factor are included, with air-to-skin coefficient conversion. We developed specific Lambert-Beer attenuation equations derived from mass energy-absorption coefficients data for skin, fat, and muscle and bone as one tissue. Anatomy tissue thickness distribution at central X-ray location in anteroposterior incidence for hand and chest, was estimate by discounting constant skin and bone thickness from patient measured width, assuming the result as muscle and fat. A clinical research at a big hospital were executed when real parameters (kV, mAs, filtration, ripple) used by technologists were combined with the image quality and patient's data: anatomy width, height and weight. A correlation among the best images acquired and electrical parameters used were confronted with patient's data and dose estimation. The best combinations were used as gold standards. Results: For each anatomy, two equations were developed to calculate voltage (kV) and exposure (mAs) to reproduce and interpolate the gold standards. Patient is measured and data are input into equations, giving radiological technologists the right set of electrical parameters for that specific exam. Conclusion: This work indicates that radiological technologist can personalize the exact electrical parameters for each patient exam, instead of using standard values. It also guarantee that patients under or over-sized measures will receive the right dose for the best image. It will stop wrong empiric adjusts technologists do when examining a non-standard patient and reduce probability of radiography retaken because of over or under exposition.

60 APPLIED LIFE SCIENCES↗

SU-E-T-399: Determination of the Radiobiological Parameters That Describe the Dose-Response Relations of Xerostomia and Disgeusia From Head and Neck Radiotherapy

Purpose: To estimate the radiobiological parameters that describe the doseresponse relations of xerostomia and disgeusia from head and neck cancer radiotherapy. To identify the organs that are best correlated with the manifestation of those clinical endpoints. Finally, to evaluate the goodnessof- fit by comparing the model predictions against the actual clinical results. Methods: In this study, 349 head and neck cancer patients were included. For each patient the dose volume histograms (DVH) of parotids (separate and combined), mandible, submandibular glands (separate and combined) and salivary glands were calculated. The follow-up of those patients was recorded at different times after the completion of the treatment (7 weeks, 3, 7, 12, 18 and 24 months). Acute and late xerostomia and acute disgeusia were the clinical endpoints examined. A maximum likelihood fitting was performed to calculate the best estimates of the parameters used by the relative seriality model. The statistical methods of the error distribution, the receiver operating characteristic (ROC) curve, the Pearson's test and the Akaike's information criterion were utilized to assess the goodness-of-fit and the agreement between the pattern of the radiobiological predictions with that of the clinical records. Results: The estimated values of the radiobiological parameters of salivary glands are D50 = 25.2 Gy, γ = 0.52, s = 0.001. The statistical analysis confirmed the clinical validity of those parameters (area under the ROC curve = 0.65 and AIC = 38.3). Conclusion: The analysis proved that the treatment outcome pattern of the patient material can be reproduced by the relative seriality model and the estimated radiobiological parameters. Salivary glands were found to have strong volume dependence (low relative seriality). Diminishing the biologically effective uniform dose to salivary glands below 30 Gy may significantly reduce the risk of complications to the patients irradiated for prostate cancer.

60 APPLIED LIFE SCIENCES↗

SU-E-J-150: Four-Dimensional Cone-Beam CT Algorithm by Extraction of Physical and Motion Parameter of Mobile Targets Retrospective to Image Reconstruction with Motion Modeling

Purpose: To develop 4D-cone-beam CT (CBCT) algorithm by motion modeling that extracts actual length, CT numbers level and motion amplitude of a mobile target retrospective to image reconstruction by motion modeling. Methods: The algorithm used three measurable parameters: apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine actual length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm were tested with mobile targets that with different well-known sizes made from tissue-equivalent gel which was inserted into a thorax phantom. The phantom moved sinusoidally in one-direction to simulate respiratory motion using eight amplitudes ranging 0–20mm. Results: Using this 4D-CBCT algorithm, three unknown parameters were extracted that include: length of the target, CT number level, speed or motion amplitude for the mobile targets retrospective to image reconstruction. The motion algorithms solved for the three unknown parameters using measurable apparent length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on the actual target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, actual target length and motion amplitude. Motion frequency and phase did not affect the elongation and CT number distribution of the mobile target and could not be determined. Conclusion: A 4D-CBCT motion algorithm was developed to extract three parameters that include actual length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement to motion tracking and sorting of the images into different breathing phases which has potential applications in diagnostic CT imaging and radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-01: Head and Neck Squamous Cell Carcinoma: Short-Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T

Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients were scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.

60 APPLIED LIFE SCIENCES↗

Estimation of trabecular bone parameters in children from multisequence MRI using texture-based regression

Purpose: This paper presents a statistical approach for the prediction of trabecular bone parameters from low-resolution multisequence magnetic resonance imaging (MRI) in children, thus addressing the limitations of high-resolution modalities such as HR-pQCT, including the significant exposure of young patients to radiation and the limited applicability of such modalities to peripheral bones in vivo. Methods: A statistical predictive model is constructed from a database of MRI and HR-pQCT datasets, to relate the low-resolution MRI appearance in the cancellous bone to the trabecular parameters extracted from the high-resolution images. The description of the MRI appearance is achieved between subjects by using a collection of feature descriptors, which describe the texture properties inside the cancellous bone, and which are invariant to the geometry and size of the trabecular areas. The predictive model is built by fitting to the training data a nonlinear partial least square regression between the input MRI features and the output trabecular parameters. Results: Detailed validation based on a sample of 96 datasets shows correlations >0.7 between the trabecular parameters predicted from low-resolution multisequence MRI based on the proposed statistical model and the values extracted from high-resolution HRp-QCT. Conclusions: The obtained results indicate the promise of the proposed predictive technique for the estimation of trabecular parameters in children from multisequence MRI, thus reducing the need for high-resolution radiation-based scans for a fragile population that is under development and growth.

60 APPLIED LIFE SCIENCES↗

Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-F-T-366: Dosimetric Parameters Enhancement of 120-Leaf Millennium MLC Using EGSnrc and IAEA Phase-Space Data

Purpose: Recently, the multileaf collimators (MLC) have become an important part of any LINAC collimation systems because they reduce the treatment planning time and improves the conformity. Important factors that affects the MLCs collimation performance are leaves material composition and their thickness. In this study, we investigate the main dosimetric parameters of 120-leaf Millennium MLC including dose in the buildup point, physical penumbra as well as average and end leaf leakages. Effects of the leaves geometry and density on these parameters are evaluated Methods: From EGSnrc Monte Carlo code, BEAMnrc and DOSXYZnrc modules are used to evaluate the dosimetric parameters of a water phantom exposed to a Varian xi for 100cm SSD. Using IAEA phasespace data just above MLC (Z=46cm) and BEAMnrc, for the modified 120-leaf Millennium MLC a new phase space data at Z=52cm is produces. The MLC is modified both in leaf thickness and material composition. EGSgui code generates 521ICRU library for tungsten alloys. DOSXYZnrc with the new phase space evaluates the dose distribution in a water phantom of 60×60×20 cm3 with voxel size of 4×4×2 mm3. Using DOSXYZnrc dose distributions for open beam and closed beam as well as the leakages definition, end leakage, average leakage and physical penumbra are evaluated. Results: A new MLC with improved dosimetric parameters is proposed. The physical penumbra for proposed MLC is 4.7mm compared to 5.16 mm for Millennium. Average leakage in our design is reduced to 1.16% compared to 1.73% for Millennium, the end leaf leakage suggested design is also reduced to 4.86% compared to 7.26% of Millennium. Conclusion: The results show that the proposed MLC with enhanced dosimetric parameters could improve the conformity of treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-09: Development of a Plan Data Aggregator for Time Efficient Physics Second-Checks of Machine Parameters for External Beam Treatment Plans

Purpose: Physics second-checks for external beam radiation therapy are performed, in-part, to verify that the machine parameters in the Record-and-Verify (R&V) system that will ultimately be sent to the LINAC exactly match the values initially calculated by the Treatment Planning System (TPS). While performing the second-check, a large portion of the physicists’ time is spent navigating and arranging display windows to locate and compare the relevant numerical values (MLC position, collimator rotation, field size, MU, etc.). Here, we describe the development of a software tool that guides the physicist by aggregating and succinctly displaying machine parameter data relevant to the physics second-check process. Methods: A data retrieval software tool was developed using Python to aggregate data and generate a list of machine parameters that are commonly verified during the physics second-check process. This software tool imported values from (i) the TPS RT Plan DICOM file and (ii) the MOSAIQ (R&V) Structured Query Language (SQL) database. The machine parameters aggregated for this study included: MLC positions, X&Y jaw positions, collimator rotation, gantry rotation, MU, dose rate, wedges and accessories, cumulative dose, energy, machine name, couch angle, and more. Results: A GUI interface was developed to generate a side-by-side display of the aggregated machine parameter values for each field, and presented to the physicist for direct visual comparison. This software tool was tested for 3D conformal, static IMRT, sliding window IMRT, and VMAT treatment plans. Conclusion: This software tool facilitated the data collection process needed in order for the physicist to conduct a second-check, thus yielding an optimized second-check workflow that was both more user friendly and time-efficient. Utilizing this software tool, the physicist was able to spend less time searching through the TPS PDF plan document and the R&V system and focus the second-check efforts on assessing the patient-specific plan-quality.

60 APPLIED LIFE SCIENCES↗

On the Physical Meaning of Disperse Parameters of Frequency Dependence of Dielectric Permittivity in the Havriliak–Negami Model

This paper is devoted to an analysis of the frequency dispersion of dielectric permittivity in order to establish the physical meaning of the dispersion parameters α and β in the Havriliak–Negami model. It is found that parameter α is associated with the spectrum broadening of relaxation time τ. Examples with the appearance of a dispersion with parameter α of about 0.4 and 0.7 are presented. A conclusion is drawn that disorder creates a broadening of the relaxation times. Dispersion parameters α and β are introduced to preserve the unified relaxation time. The possibility of the analysis of experimental results on the basis of the Debye model in order to obtain the relaxation time distribution and determine parameters α and β according to the log(τ{sub HN}/τ) chart is shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-diffusion parameters in carbon-subgroup crystals

Self-diffusion parameters have been calculated for crystals of the carbon subgroup C (diamond), Si, Ge, {alpha}-Sn, Pb. It is shown that consideration of quantum effects in the delocalization of atoms leads to the following effect: at low temperatures (below the Debye temperature), the self-diffusion parameters depend strongly on temperature and the self-diffusion entropy is negative: s{sub d} < 0. With an increase in temperature, the function s{sub d} takes positive values. All thermodynamic parameters of self-diffusion in semiconductor crystals of carbon subgroup were calculated without any fitting parameters. The temperature dependences of self-diffusion parameters were studied for IVa-subgroup crystals upon isobaric heating from T = 0 K to the melting point. A good agreement with both experimental data and theoretical estimates obtained by other researchers is obtained. The correlation between the entropy and enthalpy of self-diffusion, as well as the correlation between the volume and entropy of self-diffusion for the entire temperature range under consideration, are discussed.

36 MATERIALS SCIENCE↗

Computation and consequences of high order amplitude- and parameter-dependent tune shifts in storage rings for high precision measurements

Nonlinear effects of the various electric field and magnetic field components of storage rings to confine the particles and bend their trajectory can cause substantial amplitude-dependent tune shifts within the beam. Furthermore, tune shifts are often sensitive to variations of system parameters, e.g. total particle momentum offsets $δp$. Such amplitude- and parameter-dependent tune shifts influence the dynamics and stability of a beam in particle storage rings. Thus, it is critical for high precision measurements to analyze and understand these influences. On this basis, we present in this paper normal form methods for the calculation of high order amplitude and system parameter dependencies of the horizontal and vertical tunes in storage rings using the differential algebra (DA) framework within COSY INFINITY. A storage ring is simulated using COSY INFINITY to generate a DA Poincaré return map describing the transverse phase space behavior after each revolution in the storage ring. The map is expanded around the parameter-dependent closed orbit of the system before transforming the resulting map into normal form coordinates to extract the high order tune dependencies on the phase space amplitude and variation in the system parameters. As a specific example, a storage ring similar to the Storage Ring of the Muon g-2 Experiment at Fermilab (E989) is investigated.

43 PARTICLE ACCELERATORS↗

Estimation of Transport and Kinetic Parameters of Vanadium Redox Batteries Using Static Cells

Mathematical models of Redox Flow Batteries (RFBs) can be used to analyze cell performance, optimize battery operation, and control the energy storage system efficiently. Among many other models, physics-based electrochemical models are capable of predicting internal states of the battery, such as temperature, state-of-charge, and state-of-health. In the models, estimating parameters is an important step that can study, analyze, and validate the models using experimental data. A common practice is to determine these parameters either through conducting experiments or based on the information available in the literature. However, it is not easy to investigate all proper parameters for the models through this way, and there are occasions when important information, such as diffusion coefficients and rate constants of ions, has not been studied. Also, the parameters needed for modeling charge-discharge are not always available. In this paper, an efficient way to estimate parameters of physics-based redox battery models will be proposed. Furthermore, this paper also demonstrates that the proposed approach can study and analyze aspects of capacity loss/fade, kinetics, and transport phenomena of the RFB system.

25 ENERGY STORAGE↗

Critical Parameter Identification of Fuel-Cell Models Using Sensitivity Analysis

Numerical modeling has been a vital tool in proton-exchange-membrane fuel-cell (PEMFC) analysis; however, the predictive capabilities of these models depend on the input physical parameters, several of which are either not experimentally measured or have large scatter in measured values. This article presents an uncertainty propagation-based sensitivity analysis to identify the model parameters that impact the model predictions most. A comprehensive 2-D membrane electrode assembly (MEA) model is used to perform local sensitivity analysis at multiple operating conditions, which encompass the range of environments and operating conditions a cell can encounter. While at lower humidities, cathode kinetics and membrane-ohmic-loss related parameters are crucial, gas transport and porous-media saturation behavior are more important at humidified conditions. Several of these findings are different from previous studies presented in literature. Identifying the crucial parameters helps focus future material and cell optimization studies as well as experimental studies to quantify these parameters with higher accuracy.

25 ENERGY STORAGE↗

A Tanks-in-Series Approach to Estimate Parameters for Lithium-Ion Battery Models

Advanced Battery Management Systems (BMS) play a vital role in monitoring, predicting, and controlling the performance of lithium-ion batteries. BMS employing sophisticated electrochemical models can help increase battery cycle life and minimize charging time. However, in order to realize the full potential of electrochemical model-based BMS, it is critical to ensure accurate predictions and proper model parameterization. The accuracy of the predictions of an electrochemical model is dependent on the accuracy of its parameters, the values of which might change with battery cycling and aging. Parameter estimation for an electrochemical model is generally challenging due to the nonlinear nature and computational complexity of the model equations. To this end, this work utilizes the recently proposed Tanks-in-Series model for Li-ion batteries (J.Electrochem. Soc., 167, 013534 (2020)) to perform parameter estimation. The Tanks-in-Series approach allows for substantially faster parameter estimation compared to the original pseudo two-dimensional (p2D) model. The objective of this work is thus to demonstrate the gain in computational efficiency from the Tanks-in-Series approach. A sensitivity analysis of model parameters is also performed to benchmark the fidelity of the Tanks-in-Series model.

25 ENERGY STORAGE↗

PINNSTRIPES (Physics-Informed Neural Network SurrogaTe for Rapidly Identifying Parameters in Energy Systems) [SWR-22-12]

Energy systems models typically take the form of complex partial differential equations which make multiple forward calculations prohibitively expensive. Fast and data-efficient construction of surrogate models is of utmost importance for applications that require parameter exploration such as design optimization and Bayesian calibration. In presence of a large number of parameters, surrogate models that capture correct dependencies may be difficult to construct with traditional techniques. The issue is addressed here with the formulation of the surrogate model constructed via Physics-Informed Neural Networks (PINN) which capture the dependence with respect to the parameters to estimate, while using a limited amount of data. Since forward evaluations of the surrogate model are cheap, parameter exploration is made inexpensive, even when considering a large number of parameters.

Hassanaly, Malik↗

Empirical Relations between Size Parameters of Ice Hydrometeor Populations and Radar Reflectivity

Empirical power-law relations between the equivalent radar reflectivity factor Z e and the slope parameter of the gamma function Λ (i.e., Λ = cZ $^{d}_{e}$ used to describe ice hydrometeor size distributions) are derived. The Λ parameter can also be considered as a size parameter since it is proportional to the inverse of the hydrometeor characteristic size, which is an important geophysical parameter describing the entire distribution. Two datasets from two-dimensional microphysical probes, collected during aircraft flights in subtropical and midlatitude regions, were used to obtain Λ by fitting measured size distributions. Reflectivity for different radar frequencies was calculated from microphysical probe data by using nonspherical-particle models. The derived relations have exponent d values that are approximately from -0.35 to -0.40, and the prefactors c are approximately between 30 and 55 (Λ: cm -1 ; Z e : mm 6 m -3 ). There is a tendency for d and c to decrease when radar frequency increases from K u band (~14 GHz) to W band (~94 GHz). Correlation coefficients between Z e and Λ can be very high (~0.8), especially for lower frequencies. Such correlations are similar to those for empirical relations between reflectivity and ice water content (IWC), which are used in many modeling and remote sensing applications. Close correspondences of reflectivity to both Λ and IWC are due to a relatively high correlation between these two microphysical parameters. Finally, expected uncertainties in estimating Λ from reflectivity could be as high as a factor of 2, although estimates at lower radar frequencies are more robust. Stratifying retrievals by temperature could result in relatively modest improvement of Λ estimates.

54 ENVIRONMENTAL SCIENCES↗