Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Build Optimization Software Tools (BOOST) v2.0.0

Build Optimization Software Tools (BOOST) accelerate the design of DNA, RNA and protein sequences for their synthesis and assembly in an automated and scalable fashion. The BOOST Juggler automates the following two design tasks: - Reverse-Translation of protein sequences into DNA sequences - Codon Juggling of DNA sequences The BOOST Polisher provides the following design tasks: - The Verification of DNA sequences against DNA synthesis constraints - The Modification of DNA sequences in case they violate any DNA synthesis constraint In addition, the BOOST Polisher can be instructed to verify and modify DNA sequences against sequence patterns, such as restriction sites. The BOOST Partitioner supports both Gibson/chewback and Yeast assembly (also known as Transformation-Associated Recombination, or TAR) methods when performing the decomposition of large sequences that exceed the maximum length of DNA synthesis into synthesizable building blocks. The Partitioner can be instructed to find building blocks with appropriate overlap sequences, making their assembly into the complete construct more efficient. BOOST Workflows enable, in a customized fashion, the execution of the Juggler, Polisher, and Partitioner tools on a batch of sequences.

Sharkey, Michael↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

RELAP5-3D British and SI Unit Conversion Task

The RELAP5-3D code uses conversion factors throughout the code to convert values between British and SI units. Conversion factors are typically in each of the separate routines that perform unit conversion. This results in inconsistent unit conversion and increases the likelihood of errors being introduced in the conversion factors. Unit conversion factors were relocated to a centralized module so that these values are only entered in one location. The unit conversion values were then replaced in the various locations with a unit conversion variable. The code was tested using the verification test set after making these changes and the results were analyzed. As expected, all the cases that use British input were found to have changed. In addition, three other cases changed due to changes in conversion factors.

97 MATHEMATICS AND COMPUTING↗

Results of an In-Field Validation Exercise in Support of Wide-Area Environmental Sampling

The National Nuclear Security Administration’s (NNSA) Office of Nonproliferation and Arms Control (NA-24) is evaluating Wide-Area Environmental Sampling (WAES) as an additional safeguards verification tool for the International Atomic Energy Agency to detect undeclared nuclear activities. The NNSA is evaluating strategies for conducting a generic WAES campaign, the cost of a WAES campaign, and the effect of technological advancements that have occurred since the last major WAES review in 1999. Until now, the NNSA effort has focused on tabletop exercises (TTXs) in which high-performance computing allows for advanced modeling and simulation efforts to be applied to the WAES question. Although the modeling and simulations used in the TTXs are extremely valuable, field campaigns are still needed to validate the assumptions that underpin the models and the modeling process itself. During a 7 week period beginning in May 2023 and ending in June 2023, which included 4 weeks of active field collections, a multilaboratory team conducted its first in-field validation exercise. Prior to the in-field exercise, abbreviated TTXs were conducted to estimate the performance of all collection systems to be used during the field test. These TTXs guided the selection of materials to be released and the placement of the collection system. Based on these determinations, materials were procured to use in the field test, and an injection/release system was designed, built, and installed at the test facility. Background samples were collected during weeks one and four, and environmental collections against active releases were conducted during weeks two and three. The goals of this validation exercise included a demonstration of (1) the ability to provide controlled releases of particulates of surrogate materials, (2) the fielding and operation of collection systems (including deposition and active air collectors), and (3) the flexibility to revise equipment and campaign plans in the field. This paper presents the results and preliminary conclusions for this initial validation test. Based on these results, subsequent field campaigns are anticipated and will include the addition of other released materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-field alpha spectrometry system for uranium enrichment verification of uranium hexafluoride

A portable In-Field Alpha Spectrometry (IFAS) system was developed to support on-site uranium enrichment determination for samples taken at facilities working with gaseous UF 6 . It consists of a modified commercial alpha spectrometer, a vacuum pump, a laptop computer, and associated connectors and cables. The IFAS uses specially designed Single-Use Destructive Assay (SUDA) samplers to capture gaseous UF 6 and convert and store it as UO 2 F 2 in a thin-film zeolite. To examine the quantitative performance of the IFAS system a large number of replicate SUDA samples was acquired for natural uranium (NU, 0.72 wt%, 23 samples), low enriched uranium 1 (LEU1, 2.33 wt% 235 U, 10 samples), and low enriched uranium 2 (LEU2, 4.62 wt% 235 U, 10 samples). The standard deviation (SD) values for uranium enrichment determination with the IFAS for NU, LEU1, and LEU2, in 20-hour assays, were 0.037 wt% 235 U, 0.063 wt% 235 U, and 0.072 wt% 235 U, respectively. In addition, a separate analysis suggests that comparable SD values can be achieved in less time, approximately 8-10 hours. For context, these SD values are well below the International Atomic Energy Agency’s International Target Values for the determination of uranium enrichment in non-destructive assay measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

OC6 Phase III Definition Document

The objective of Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was to evaluate the accuracy of aerodynamic load predictions by offshore wind modeling tools for a floating offshore wind turbine as it experiences large surge-translational and pitch-rotational motion, as would occur during normal operation. A variety of models were examined in the project, with the goal of performing a three-way validation between engineering-level tools, higher-fidelity tools, and measurement data from two wind tunnel experimental campaigns. This document provides the necessary information to model and simulate the system studied in the OC6 Phase III project. This information is not only useful for project participants, but also future modelers who want to replicate this work for verification and validation purposes.

17 WIND ENERGY↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2024

Energy Savings Performance Contracts (ESPCs) are a contractual mechanism that allow a federal agency to procure energy savings and facility improvements without upfront capital costs to reduce costs and enhance mission resiliency. ESPCs are covered under FAR Part 23.2, and 42 USC § 8287. Section 8287(a)(2)(A) of Title 42 of the U.S. Code requires that each energy savings performance contract (ESPC) undergo an annual energy audit, resulting in a separate audit report for every project. The objective of the present report is to compile and analyze all annual ESPC audit reports issued between October 1, 2023, and September 30, 2024, for projects awarded under Generations 1, 2, and 3 of DOE’s ESPC IDIQ contracts. During this period, 205 measurement and verification (M&V) reports were produced for 200 projects; the total number of reports exceeds the number of projects because some projects generated more than one report (for example, a few projects measure savings twice per year and produce two audit reports annually, each covering a different six-month period). By aggregating the results from these individual audits, the report determines the portfolio-wide realization rate of energy and cost savings for all active ESPC projects awarded under DOE’s IDIQ program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Formulation, Design and Experimental Verification of an Open Circuit Electro-Hydraulic Actuator

With the recent electrification trend in the fluid power area, more research has been incentivized to the proposal of cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective mobile solution while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions and is validated by numerical as well as experimental methods. Here, a simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. The good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Impact of Increased Verification Measurements of Category III/IV Material Receipts

Revisions to the US Department of Energy (DOE) regulations for material control and accountability are expected to dramatically increase the number of verification measurements required upon receipt of nuclear material transfers. Material categories and types that were not routinely quantitatively measured upon receipt (Category III and IV) have been added to the more detailed regulations on shipments and receipts of nuclear materials. In anticipation of this change to the regulations, this project was initiated to identify measurement needs in the DOE complex with respect to performing these additional quantitative measurements. The results of surveying multiple DOE facilities to understand the scope of the impact and the potential measurement capability needs are presented.

Bean, Robert↗

Uncertainty Analysis and Software Verification

Uncertainty analyses are an important part of calibrations and testing. They allow researchers insight on how to reduce and mitigate errors in testing. Each device used in testing introduces error in a system, as well as other sources such as environmental conditions, electronics, analog to digital, and random errors. Each source is carefully examined to identify how much error it introduces to a system. These sources are then combined using various methods of uncertainty calculations. To verify and validate software, a manual calculation is required to ensure the software is performing as intended. Using Excel to verify the calculations, we can identify discrepancies within the software. The root of the sum of the squares uncertainty (RSS) is used to find the combined uncertainty of a device at one and two standard deviations of the mean. Calibrations on accelerometers are performed using a vibration system along with a back-toback reference accelerometer. The vibration system takes a reference point at 100Hz frequency at 10g amplitude. The sensitivities are collected at each dialed in frequency. The sensitivity of the device represents the electrical output of the UUT (mV, pC, etc.) per unit of acceleration (g). The full history of sensitivities of selected accelerometers are used to find the averaged, standard deviation, and uncertainty of the device at each frequency tested. The uncertainty calculations from excel and the software are then compared.

97 MATHEMATICS AND COMPUTING↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Pronghorn Porous Media Model Validation with Pressure Drop Measurements

The verification and validation (V&V) of Pronghorn is imperative to assert its accuracy when predicting the fluid velocity, temperature, and pressure in high temperature gas-cooled reactors. Pronghorn is a coarse-mesh, intermediate-fidelity, and multidimensional thermal-hydraulics (TH) code developed by the Idaho National Laboratory (INL). New pebble bed experiments are used to observe the details of the fluid motion and pressure drop in the porous bed under the reactor normal operation. This paper focuses on the validation of the Pronghorn compressible and incompressible Navier-Stokes equations using the pressure drop measurements performed at the engineering-scale pebble bed facility at the Texas A&M university (TAMU). Various pressure drop correlations and porosity functions are implemented in both Pronghorn and STAR-CCM+ to compare the pressure drop due to the combined viscous and inertial resistances in the porous bed. The correlations accounting for the near-wall effect are also utilized to observe if the pressure drop estimates can be improved. Pronghorn porous media models predict the pressure drop well relative to the STAR-CCM+ simulation results and 1D correlations, and both the finite element method (FEM) and finite volume method (FVM) perform accurately. Pronghorn models are also validated with the experimental measurements given the different Reynolds number ranges and specific aspect ratios. The likelihood of the statistical significance between the pressure drop measurements and specific correlations or simulations is low provided that the overlap of their confidence intervals is more than the half of a single arm. Several validation metrics are reasonable in regard to the similar studies from other literature. The precise average pebble bed porosity estimation has much impact on the pressure drop, and the Foumeny and Montillet (dense packing) models carry out the accurate pressure drop prediction by considering the near-wall effect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utilizing a Virtual Sodium-Cooled Fast Reactor Digital Twin to Aid in Diversion Pathway Analysis for International Safeguards Applications

We report digital twin technology has the potential to improve the effectiveness of international safeguards inspectors by providing a tool which can: first, perform an accurate diversion path analysis, identify their indicators, and required sensors to detect them; and second, monitor facilities in real-time using critical data streams that benefit from this safeguards-by-design approach. Safeguards inspectors are required to visit facilities and verify the nuclear material to ensure no diversion has taken place and detect misuse of the facility; however, this analysis and verification effort is time consuming, and with limited funding it is imperative that time spent at a nuclear facility is focused on key areas. A virtual digital twin of three prototypic sodium fast reactors was developed, where diversion and misuse scenarios were explored to determine how a digital twin could provide inspectors with an understanding of how proliferation may occur and where the most likely areas for proliferation would be. For each of the three reactors, an optimization algorithm was able to find core designs which would be difficult to detect via sensors alone; however, the use of a machine learning adapter provided by the digital twin was able to show general trends in where proliferation as likely to take place.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experiments at Sandia to Measure the Effect of Temperature on Critical Systems

Estimation of the uncertainty in a critical experiment attributable to uncertainties in the measured experiment temperature is done by calculating the variation of the eigenvalue of a benchmark configuration as a function of temperature. In the low-enriched water-moderated critical experiments performed at Sandia, this is done by 1) estimating the effects of changing the water temperature while holding the UO 2 fuel temperature constant, 2) estimating the effects of changing the UO 2 temperature while holding the water temperature constant, and 3) combining the two results. This assumes that the two effects are separable. The results of such an analysis are nonintuitive and need experimental verification. Critical experiments are being planned at Sandia National Laboratories (Sandia) to measure the effect of temperature on critical systems and will serve to test the methods used in estimating the temperature effects in critical experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiments at Sandia to Measure the Effect of Temperature on Critical Systems [Slides]

Estimation of the uncertainty in a critical experiment attributable to uncertainties in the measured experiment temperature is done by calculating the variation of the eigenvalue of a benchmark configuration as a function of temperature. In the low-enriched water-moderated critical experiments performed at Sandia, this is done by 1) estimating the effects of changing the water temperature while holding the UO 2 fuel temperature constant, 2) estimating the effects of changing the UO 2 temperature while holding the water temperature constant, and 3) combining the two results. This assumes that the two effects are separable. The results of such an analysis are nonintuitive and need experimental verification. Critical experiments are being planned at Sandia National Laboratories (Sandia) to measure the effect of temperature on critical systems and will serve to test the methods used in estimating the temperature effects in critical experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling fission product diffusion in TRISO fuel particles with BISON

Diffusion of fission products in intact TRISO particles depends on particle geometry, fission product source rates, time, temperature, and temperature-dependent diffusion coefficients. Simulating this diffusion process requires models for source rates and diffusion coefficients, plus computation of the temperature field if not prescribed. In addition, simulation quality depends on discretization of the geometry, appropriate time stepping, and the accuracy of the solution method. In this paper, we explore the simulation of fission product diffusion in TRISO fuel particles using the finite element method via the fuel performance code Bison. Recent material model development has occurred in Bison for each material present in tri-structural isotropic (TRISO) fuel particles: the buffer, inner pyrolytic carbon, silicon carbide, and outer pyrolytic carbon layers, as well as the fuel kernel. Also, new mesh generation and fission product release fraction capabilities have been added. Diffusion capabilities are shown to converge to the correct solution via formal verification tests. A large number of code benchmarking problems are also given, with good results, showing that Bison’s computed release fractions closely match those of other software tools. Finally, a significant validation effort is detailed in which fission product release, measured as part of the AGR-1 capsule experiments, is compared to Bison outputs. Bison outputs compare very well to the experimental data and to PARFUME results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensor Impacts Evaluation and Verification: Expert Interview Responses

The sensor configuration/deployment method has critical impacts on energy efficient building control and thermal comfort. However, traditional sensor techniques for building operation and fault detection and diagnostics (FDD) are not necessarily optimal in terms of energy efficiency and thermal comfort, and their global effects are not thoroughly investigated. In an effort to address and overcome this limitation, a multilaboratory and multiyear project, “Sensor Impact Evaluation and Verification,” was proposed. Its purpose is to develop a framework to investigate the impacts of sensor deployment and configuration on building energy optimization, FDD, occupant thermal comfort, and potentially grid efficiency. The first project task was a literature review to establish a solid knowledge of and a background related to sensor technologies and placement. To accomplish this task, an extensive review of previous research literature was performed. A series of expert interviews were conducted to augment the findings of the literature review. This report summarizes the interview design and interview results and findings. The interview was designed and performed to (1) investigate the current status and limitations of sensor configuration, (2) identify the research gaps and expectations for potential improvements in sensor configuration and deployment, and (3) integrate expert (e.g., researcher, building operation practitioner) knowledge and experience to develop use-case scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗