Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase space methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗

Overcoming potential energy distortions in constrained internal coordinate molecular dynamics simulations

The Internal Coordinate Molecular Dynamics (ICMD) method is an attractive molecular dynamics (MD) method for studying the dynamics of bonded systems such as proteins and polymers. It offers a simple venue for coarsening the dynamics model of a system at multiple hierarchical levels. For example, large scale protein dynamics can be studied using torsional dynamics, where large domains or helical structures can be treated as rigid bodies and the loops connecting them as flexible torsions. ICMD with such a dynamic model of the protein, combined with enhanced conformational sampling method such as temperature replica exchange, allows the sampling of large scale domain motion involving high energy barrier transitions. Once these large scale conformational transitions are sampled, all-torsion, or even all-atom, MD simulations can be carried out for the low energy conformations sampled via coarse grained ICMD to calculate the energetics of distinct conformations. Such hierarchical MD simulations can be carried out with standard all-atom forcefields without the need for compromising on the accuracy of the forces. Using constraints to treat bond lengths and bond angles as rigid can, however, distort the potential energy landscape of the system and reduce the number of dihedral transitions as well as conformational sampling. We present here a two-part solution to overcome such distortions of the potential energy landscape with ICMD models. To alleviate the intrinsic distortion that stems from the reduced phase space in torsional MD, we use the Fixman compensating potential. To additionally alleviate the extrinsic distortion that arises from the coupling between the dihedral angles and bond angles within a force field, we propose a hybrid ICMD method that allows the selective relaxing of bond angles. This hybrid ICMD method bridges the gap between all-atom MD and torsional MD. We demonstrate with examples that these methods together offer a solution to eliminate the potential energy distortions encountered in constrained ICMD simulations of peptide molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-JeP2-09: Minimal Skin Dose Increase in Longitudinal Rotating Biplanar Linac-MR Systems: Examination of Radiation Energy and Flattening Filter Design

Purpose: To quantify increase in entrance skin-dose due to magnetic fields of the Alberta longitudinal linac-MR by examining the effect of radiation energy and flattening filter, using Monte Carlo calculations and accurate 3-D models of the magnetic field. Methods: The 3-D magnetic fields generated by the bi-planar Linac-MR are calculated with FEM using Opera-3D. BEAMnrc simulates the particle phase-space in the presence of the rapidly decaying fringe field of 0.5T MRI assembled with a Varian 600C linac with an isocentre distance of 130 cm for 6 MV and 10 MV beams. Skin doses are calculated at an average depth of 70 µm using DOSXYZnrc with varying SSDs and field sizes. Furthermore, flattening filters are reshaped to compensate for the significant drop in dose rate due to increased SAD of 130 cm and skin-doses are evaluated. Results: The confinement effect of the MRI fringe field on the contaminant electrons is minimal. For SSDs of 100 – 120 cm the increase in skin dose is ∼6% – 19% and ∼1% – 9% for the 6 and 10 MV beams, respectively. For 6MV, skin dose increases from ∼10.5% to 1.5%. for field-size increases of 5×5 cm2 to 20×20 cm2. For 10 MV, skin dose increases by ∼6% for a 5×5 cm2 field, and decreases by ∼1.5% for a 20×20 cm2 field. The reshaped flattening filter increases the dose rate from 355 MU/min to 529 MU/min (6 MV) or 604 MU/min (10 MV), while the skin-dose increases by only an additional ∼2.6% (all percent increases in skin dose are relative to Dmax). Conclusion: There is minimal increase in the entrance skin dose and minimal/no decrease in the dose rate of the Alberta longitudinal linac-MR system. There is even lower skin-dose increase at 10 MV. Funding: Alberta Innovates - Health Solutions (AIHS) Conflict of Interest: Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

Machine-assisted discovery of integrable symplectic mappings

Integrable systems possess a hidden symmetry associated with the existence of conserved quantities known as integrals of motion. These systems play an important role in understanding general dynamics in accelerators and have potential for future designs. This work will cover two automated methods for finding integrable symplectic maps of the plane. The first algorithm is based on the observation that the evolution of an integrable system in phase space is confined to a lower-dimensional submanifold of a specific type. The second algorithm relies on an analysis of dynamical variables. Both methods rediscover some of the famous McMillan-Suris integrable mappings and ultra-discrete Painlev\'e equations. Over 100 new integrable families are presented and analyzed, some of which are isolated in the space of parameters, while others are families with one parameter (or the ratio of parameters) being either continuous or discrete. In addition, the newly discovered maps are related to a general 2D symplectic map through the use of discrete perturbation theory. A method is proposed for constructing smooth near-integrable dynamical systems based on mappings with polygon invariants.

43 PARTICLE ACCELERATORS↗

Machine-Assisted Discovery of Integrable Symplectic Mappings

Integrable systems possess a hidden symmetry associated with the existence of conserved quantities known as integrals of motion. These systems play an important role in understanding general dynamics in accelerators and have potential for future designs. This work will cover two automated methods for finding integrable symplectic maps of the plane. The first algorithm is based on the observation that the evolution of an integrable system in phase space is confined to a lower-dimensional submanifold of a specific type. The second algorithm relies on an analysis of dynamical variables. Both methods rediscover some of the famous McMillan-Suris integrable mappings and ultra-discrete Painlev\'e equations. Over 100 new integrable families are presented and analyzed, some of which are isolated in the space of parameters, while others are families with one parameter (or the ratio of parameters) being either continuous or discrete. In addition, the newly discovered maps are related to a general 2D symplectic map through the use of discrete perturbation theory. A method is proposed for constructing smooth near-integrable dynamical systems based on mappings with polygon invariants.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probability density adjoint for sensitivity analysis of the Mean of Chaos

Sensitivity analysis, especially adjoint based sensitivity analysis, is a powerful tool for engineering design which allows for the efficient computation of sensitivities with respect to many parameters. However, these methods break down when used to compute sensitivities of long-time averaged quantities in chaotic dynamical systems. This paper presents a new method for sensitivity analysis of ergodic chaotic dynamical systems, the density adjoint method. The method involves solving the governing equations for the system's invariant measure and its adjoint on the system's attractor manifold rather than in phase-space. This new approach is derived for and demonstrated on one-dimensional chaotic maps and the three-dimensional Lorenz system. It is found that the density adjoint computes very finely detailed adjoint distributions and accurate sensitivities, but suffers from large computational costs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic and ferroelectric ordering in BiMn{sub 2}O{sub 5} oxide

A group-theoretical analysis of the magnetic phase of BiMn{sub 2}O{sub 5} oxide is performed using the space symmetry group of the compound. Using the projection operator method, we determine the basis functions of the irreducible representation of the space group, which are expressed in terms of the magnetic vector components. This representation can govern two phase transitions from the paramagnetic state to the antiferromagnetic phase with close temperatures and ordering of the spins of manganese ions in two crystallographic positions. It is found from renorm group analysis of these transitions that when these transitions occur as second- order transitions, the electric polarization does not appear in the system because spin fluctuations in this case elevate the symmetry of the system. Polarization appears when at least one of these transitions becomes a first-order transition as a result of spin fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Graphical Methods for Separating Beam and Target Fragmentation Regions

For reactions involving three or more final-state particles, graphical methods can help to elucidate the dominant reaction mechanism. Van Hove [1] introduced a longitudinal phase space plot, which categorizes reaction products in terms of their longitudinal moments. We review the construction of such plots, and show how they are useful in separating beam and target fragmentation regimes. We summarize the information that can be obtained from Van Hove plots, and use these plots to analyze reactions with three or four strongly-interacting particles in the final state. As an example, we apply these methods to simulated data for the reaction ??+p???+?(??)+p. We show how cuts in the Van Hove plot can be utilized to isolate various two-body processes that contribute to this reaction. We also show how the dominant reaction processes change with the beam energy.\\[4pt] [1] L. Van Hove, Phys. Lett. B28, 429 (1969).

Londergan, J.T.↗

Soft Expansion of Double-Real-Virtual Corrections to Higgs Production at N$^3$LO

We present methods to compute higher orders in the threshold expansion for the one-loop production of a Higgs boson in association with two partons at hadron colliders. This process contributes to the N 3 LO Higgs production cross section beyond the soft-virtual approximation. We use reverse unitarity to expand the phase-space integrals in the small kinematic parameters and to reduce the coefficients of the expansion to a small set of master integrals. We describe two methods for the calculation of the master integrals. The first was introduced for the calculation of the soft triple-real radiation relevant to N 3 LO Higgs production. The second uses a particular factorization of the three body phase-space measure and the knowledge of the scaling properties of the integral itself. Our result is presented as a Laurent expansion in the dimensional regulator, although some of the master integrals are computed to all orders in this parameter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-658: Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation

Purpose: Patient dose far from the treatment field is comprised of scatter from within the patient, and treatment head leakage. We quantify the treatment head leakage for TrueBeam linear accelerator for 6X and 6X-FFF beams by comparing measurements to Monte Carlo simulations for a variety of jaw sizes and collimator rotations. This work is conceptually similar to that of Kry et al. (Medical Physics 2006; 33: 4405), who considered a Clinac linear accelerator. Methods: Measurements were made using an EXRADIN A101 ion chamber positioned in the patient plane, at distances up to 100 cm from isocenter. Simulations were done using VirtuaLinac, the GEANT4-based Monte Carlo model of the TrueBeam treatment head, and an in-house (U. Virginia) GEANT4-based code. In-house code modelled an ion chamber with build-up, based on a CT scan of the chamber. VirtuaLinac included a detailed model of the treatment head shielding, and was run on the Amazon Web Services cloud to generate spherical phase space files surrounding the treatment head. These phase space files were imported into the in-house code. Results: Initial comparisons between measurements and simulation showed an excess of dose in the in-plane direction, away from the gantry, in the simulations. This was traced to an incomplete model of the shielding—specifically, the component holding the primary collimator was smaller in the model than in the TrueBeam. Modifications were made to VirtuaLinac to more closely match the engineering drawings. In the in-plane direction, the lowest out of field dose was away from gantry (negative abscissa values) at around 60 cm from isocenter, for fields smaller than 10×10 cm2. Out of field dose decreased with decreasing jaw size. Flattening-filter free beam produced out-of-field doses as low as 65% of those with flattened beam. Conclusion: Doses determined from simulation and measurement were in close agreement. Funding support from the Jefferson Trust Foundation.

60 APPLIED LIFE SCIENCES↗

Fully-Implicit Orthogonal Reconstructed Discontinuous Galerkin for Fluid Dynamics with Phase Change

A new reconstructed Discontinuous Galerkin (rDG) method, based on orthogonal basis/test functions, is developed for fluid flows on unstructured meshes. Orthogonality of basis functions is essential for enabling robust and efficient fully-implicit Newton-Krylov based time integration. The method is designed for generic partial differential equations, including transient, hyperbolic, parabolic or elliptic operators, which are attributed to many multiphysics problems. We demonstrate the method’s capabilities for solving compressible fluid-solid systems (in the low Mach number limit), with phase change (melting/solidification), as motivated by applications in Additive Manufacturing (AM). We focus on the method’s accuracy (in both space and time), as well as robustness and solvability of the system of linear equations involved in the linearization steps of Newton-based methods. The performance of the developed method is investigated for highly-stiff problems with melting/solidification, emphasizing the advantages from tight coupling of mass, momentum and energy conservation equations, as well as orthogonality of basis functions, which leads to better conditioning of the underlying (approximate) Jacobian matrices, and rapid convergence of the Krylov-based linear solver.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-795: Validations of Dose Calculation Accuracy of Acuros BV in High-Dose-Rate (HDR) Brachytherapy with a Shielded Cylinder Applicator Using Monte Carlo Simulation

Purpose: Acuros BV has become available to perform accurate dose calculations in high-dose-rate (HDR) brachytherapy with phantom heterogeneity considered by solving the Boltzmann transport equation. In this work, we performed validation studies regarding the dose calculation accuracy of Acuros BV in cases with a shielded cylinder applicator using Monte Carlo (MC) simulations. Methods: Fifteen cases were considered in our studies, covering five different diameters of the applicator and three different shielding degrees. For each case, a digital phantom was created in Varian BrachyVision with the cylinder applicator inserted in the middle of a large water phantom. A treatment plan with eight dwell positions was generated for these fifteen cases. Dose calculations were performed with Acuros BV. We then generated a voxelized phantom of the same geometry, and the materials were modeled according to the vendor’s specifications. MC dose calculations were then performed using our in-house developed fast MC dose engine for HDR brachytherapy (gBMC) on a GPU platform, which is able to simulate both photon transport and electron transport in a voxelized geometry. A phase-space file for the Ir-192 HDR source was used as a source model for MC simulations. Results: Satisfactory agreements between the dose distributions calculated by Acuros BV and those calculated by gBMC were observed in all cases. Quantitatively, we computed point-wise dose difference within the region that receives a dose higher than 10% of the reference dose, defined to be the dose at 5mm outward away from the applicator surface. The mean dose difference was ∼0.45%–0.51% and the 95-percentile maximum difference was ∼1.24%–1.47%. Conclusion: Acuros BV is able to accurately perform dose calculations in HDR brachytherapy with a shielded cylinder applicator.

60 APPLIED LIFE SCIENCES↗

Entanglement and localization of a two-mode Bose-Einstein condensate

A simple second quantization model is used to describe a two-mode Bose-Einstein condensate (BEC), which can be written in terms of the generators of a SU(2) algebra with three parameters. We study the behavior of the entanglement entropy and localization of the system in the parameter space of the model. The phase transitions in the parameter space are determined by means of the coherent state formalism and the catastrophe theory, which besides let us get the best variational state that reproduces the ground state energy. This semiclassical method let us organize the energy spectrum in regions where there are crossings and anticrossings. The ground state of the two-mode BEC, depending on the values of the interaction strengths, is dominated by a single Dicke state, a spin collective coherent state, or a superposition of two spin collective coherent states. The entanglement entropy is determined for two recently proposed partitions of the two-mode BEC that are called separation by boxes and separation by modes of the atoms. The entanglement entropy in the boxes partition is strongly correlated to the properties of localization in phase space of the model, which is given by the evaluation of the second moment of the Husimi function. To compare the fitness of the trial wavefunction its overlap with the exact quantum solution is evaluated. The entanglement entropy for both partitions, the overlap and localization properties of the system get singular values along the separatrix of the two-mode BEC, which indicates the phase transitions which remain in the thermodynamical limit, in the parameter space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical transitions in large systems of mean field-coupled Landau-Stuart oscillators: Extensive chaos and cluster states

In this paper, we study dynamical systems in which a large number N of identical Landau-Stuart oscillators are globally coupled via a mean-field. Previously, it has been observed that this type of system can exhibit a variety of different dynamical behaviors. These behaviors include time periodic cluster states in which each oscillator is in one of a small number of groups for which all oscillators in each group have the same state which is different from group to group, as well as a behavior in which all oscillators have different states and the macroscopic dynamics of the mean field is chaotic. We argue that this second type of behavior is “extensive” in the sense that the chaotic attractor in the full phase space of the system has a fractal dimension that scales linearly with N and that the number of positive Lyapunov exponents of the attractor also scales linearly with N. An important focus of this paper is the transition between cluster states and extensive chaos as the system is subjected to slow adiabatic parameter change. We observe discontinuous transitions between the cluster states (which correspond to low dimensional dynamics) and the extensively chaotic states. Furthermore, examining the cluster state, as the system approaches the discontinuous transition to extensive chaos, we find that the oscillator population distribution between the clusters continually evolves so that the cluster state is always marginally stable. This behavior is used to reveal the mechanism of the discontinuous transition. We also apply the Kaplan-Yorke formula to study the fractal structure of the extensively chaotic attractors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗

Mapping and uncertainty analysis of energy and pitch angle phase space in the DIII-D fast ion loss detector

New phase space mapping and uncertainty analysis of energetic ion loss data in the DIII-D tokamak provides experimental results that serve as valuable constraints in first-principles simulations of energetic ion transport. Beam ion losses are measured by the fast ion loss detector (FILD) diagnostic system consisting of two magnetic spectrometers placed independently along the outer wall. Monte Carlo simulations of mono-energetic and single-pitch ions reaching the FILDs are used to determine the expected uncertainty in the measurements. Modeling shows that the variation in gyrophase of 80 keV beam ions at the FILD aperture can produce an apparent measured energy signature spanning across 50-140 keV. These calculations compare favorably with experiments in which neutral beam prompt loss provides a well known energy and pitch distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A finite-difference implementation of the Caldeira-Leggett master equation

The Caldeira-Leggett master equation for dissipative quantum dynamics has predominantly been implemented in phase space, where it plays the role of a quantum Fokker-Planck equation. Here we demonstrate the feasibility of a pure coordinate space implementation in the case of intermediate damping strength and temperature, for times long enough to observe thermal equilibration. After a thorough numerical investigation of the analytically solvable harmonic oscillator case, a Morse oscillator model is studied. This is a case in which a quantal phase space approach would be difficult to implement and we show how analytical results for thermal averages are reproduced to a surprisingly high degree.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative characterization of spatial distribution of particles in materials: Application to materials processing

Most engineering materials contain second phase particles or fibers which serve to reinforce the matrix phase. The effect of reinforcements on material properties is usually analyzed in terms of the average volume fraction and spacing of reinforcements, quantities which are global microstructural characteristics. However, material properties can also depend on local microstructural characteristics; for example, on how uniformly the reinforcing phase is distributed in the material. The analysis method will then be applied to a materials processing problem to discover how processing parameters can be selected to maximize redistribution of the reinforcing phase during processing. Several mathematical analysis methods could be adapted to the problem of characterizing the distribution of particles in materials. A tessellation-based method was selected. In the first phase of the investigation, a software package was written to automate the analysis. Typical results are shown. The analysis technique allows the degree to which particles are clustered together, the size and spacing of particle clusters, and the particle density in clusters to be found. The analysis methods were applied to computer-generated distributions and to a few real particle-containing materials. Methods for analyzing a nonuniform particle distribution in a material can be applied to two broad classes of materials science problems: understanding how the resulting particle distribution affects properties. The analysis method described is applied to a materials processing problem: how to select extrusion conditions to maximize the redistribution of reinforcing particles that are initially nonuniformly distributed. In addition, the tessellation-based method to analyze star distributions in spiral galaxies was adapted, illustrating the diverse types of problems to which the analysis method can be applied.

Parse, J. B.↗