A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-scale, precision xenon doping of liquid argon

The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Additionally, although the idea of adding small quantities of xenon (doping) to enhance the light yield has attracted considerable interest, this technique has never been demonstrated at the necessary scale or precision. Here we report on xenon doping in a 100 l cryogenic vessel. Xenon doping was performed in four concentrations of 1.00 ± 0.06 ppm, 2.0 ± 0.1 ppm, 5.0 ± 0.3 ppm, and 10.0 ± 0.5 ppm. These measurements represent the most precise xenon doping measurements as of publishing. We observed an increase in average light yield by a factor of 1.92 ± 0.12(syst) ± 0.02(stat) at a dopant concentration of 10 ppm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling event-by-event precision in γ-ray cascades for neutron-induced reactions

Neutron-induced γ-ray spectra provide key inputs for modern active interrogation applications. A precise modeling of the nuclear reaction and subsequent emission of γ rays is challenging and often impossible due to limitations on evaluated data file formats and nuclear transport simulation codes. We present a framework that addresses these challenges by combining experimental data and reaction-model calculation outputs into an extended candidate version of the Generalized Nuclear Data Structure (GNDS) file, the successor format for the legacy Evaluated Nuclear Data File (ENDF-6). This proposed GNDS hierarchical format contains all the necessary ingredients for inline γ-ray cascade reproduction with event-by-event precision, including continuum–continuum and continuum–discrete transitions following neutron-capture and inelastic neutron scattering reactions. Cascade-event generation based on our approach demonstrates improved energy conservation on an event-by-event basis and permits the use of γ-γ coincidences in applications. This work offers, for the first time, a method to generate neutron-capture and inelastic neutron-scattering γ-ray cascades where energy conservation, correlations, and experimental primaries are fully accounted for.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Dijet Acoplanarity Tomography of the Chromo Structure of Perfect QCD Fluids

Dijet acoplanarity is dominated by vacuum (Sudakov) pQCD radiation even in Pb+Pb collisions, but future higher precision measurements of the tails of the acoplanarity distributions can help to resolve separately the medium opacity, χ=L/λ and the color screening scale μ 2 from the path averaged BDMS saturation scale Q$^2_s$[χ,μ]=∫dL$\hat{q}$(E,T(L))∝μ 2 L/λ that is already well constrained by nuclear modification factor data on R AA (p T ). We compare Gaussian (BDMS) and non-Gaussian (GLV) models of medium broadening of vacuum (Sudakov) induced acoplanarity distributions in A+A. With few percent accuracy on the ratio of A+A to p+p distributions, experiments can easily identify non-Gaussian Landau and Rutherford tails due to multiple collisions. However, we find that sub-percent precision will be required to constrain χ and μ separately from Q s .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise measurement of nuclear interaction cross sections towards neutron-skin determination with R 3 B

The R 3 B (Reactions with Relativistic Radioactive Beams) experiment as a major instrument of the NUSTAR collaboration for the research facility FAIR in Darmstadt is designed for kinematically complete studies of reactions with high-energy radioactive beams. Part of the broad physics program of R 3 B is to constrain the asymmetry term in the nuclear equation-of-state and hence improve the description of highly asymmetric nuclear matter (e.g., in neutron stars). For a precise determination of the neutron-skin thickness – an observable which is directly correlated with the symmetry energy in theoretical calculations – by measuring absolute fragmentation cross sections, it is essential to quantify the uncertainty and challenge the reaction model under stable conditions. During the successful FAIR Phase-0 campaign of R 3 B, we precisely measured the energy dependence of total interaction cross sections in 12 C + 12 C collisions, for a direct comparison with calculations based on the eikonal reaction theory.

Ponnath, L. (ORCID:0000000286742624)↗

Precise mass measurements of A = 133 isobars with the Canadian Penning Trap: Resolving the Q β − anomaly at 133Te

We report precision mass measurements of 133 Sb 133g,m Te, and 133g,m I, produced at CARIBU at Argonne National Laboratory's ATLAS facility and measured using the Canadian Penning Trap mass spectrometer. These masses clarify an anomaly in the 133 Te β-decay. The masses reported in the 2020 Atomic Mass Evaluation (M. Wang et al., 2021) produce Q B - ( 133 Te)=2920(6) keV; however, the highest-lying 133 I level populated in this decay is observed at E i = 2935.83(15) keV, resulting in an anomalous Q$^i_B-$ = -16(6)keV. Our new measurements give Q B - ( 133 Te)=2934.8(11) keV, a factor of five more precise, yielding Q$^i_B$ = -1.0(12) keV, a 3σ shift from the previous results. This resolves this anomaly, but indicates further anomalies in our understanding of the structure of this isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Milky Way, coming into focus: Precision astrometry probes its evolution and its dark matter

The growing trove of precision astrometric observations from the Gaia space telescope and other surveys is revealing the structure and dynamics of the Milky Way in ever more exquisite detail. We summarize the current status of our understanding of the structure and the characteristics of the Milky Way, and we review the emerging picture: the Milky Way is evolving through interactions with the massive satellite galaxies that stud its volume, with evidence pointing to a cataclysmic past. It is also woven with stellar streams, and observations of streams, satellites, and field stars offer new constraints on its dark matter, both on its spatial distribution and its fundamental nature. The recent years have brought much focus to the study of dwarf galaxies found within our Galaxy’s halo and their internal matter distributions. In this review, we focus on the predictions of the cold dark matter paradigm at small mass scales through precision astrometric measurements, and we summarize the modern consensus on the extent to which small-scale probes are consistent with this paradigm. We note the discovery prospects of these studies, and also how they intertwine with probes of the dynamics and evolution of the Milky Way in various and distinct ways.

79 ASTRONOMY AND ASTROPHYSICS↗

High precision tests of QCD without scale or scheme ambiguities: The 40th anniversary of the Brodsky–Lepage–Mackenzie method

A key issue in making precise predictions in QCD is the uncertainty in setting the renormalization scale μ r and thus determining the correct values of the QCD running coupling α s (μ r ) at each order in the perturbative expansion of a QCD observable. It has often been conventional to simply set the renormalization scale to the typical scale of the process Q and vary it in the range μ r $\in$ [Q/2, 2Q] in order to estimate the theoretical error. This is the practice of Conventional Scale Setting (CSS). The resulting CSS prediction will however depend on the theorist’s choice of renormalization scheme and the resulting pQCD series will diverge factorially. It will also disagree with renormalization scale setting used in QED and electroweak theory thus precluding grand unification. A solution to the renormalization scale-setting problem is offered by the Principle of Maximum Conformality (PMC), which provides a systematic way to eliminate the renormalization scale-and-scheme dependence in perturbative calculations. The PMC method has rigorous theoretical foundations, it satisfies Renormalization Group Invariance (RGI) and preserves all self-consistency conditions derived from the renormalization group. The PMC cancels the renormalon growth, reduces to the Gell-Mann–Low scheme in the N c → 0 Abelian limit and leads to scale- and scheme-invariant results. The PMC has now been successfully applied to many high-energy processes. In this article we summarize recent developments and results in solving the renormalization scale and scheme ambiguities in perturbative QCD. In particular, we present a recently developed method the PMC ∞ and its applications, comparing the results with CSS. The method preserves the property of renormalizable SU(N)/U(1) gauge theories defined as Intrinsic Conformality (iCF). This property underlies the scale invariance of physical observables and leads to a remarkably efficient method to solve the conventional renormalization scale ambiguity at every order in pQCD. This new method reflects the underlying conformal properties displayed by pQCD at NNLO, eliminates the scheme dependence of pQCD predictions and is consistent with the general properties of the PMC. A new method to identify conformal and β-terms, which can be applied either to numerical or to theoretical calculations is also shown. We present results for the thrust and C-parameter distributions in e + e - annihilation showing errors and comparison with the CSS. We also show results for a recent innovative comparison between the CSS and the PMC ∞ applied to the thrust distribution investigating both the QCD conformal window and the QED N c → 0 limit. In order to determine the thrust distribution along the entire renormalization group flow from the highest energies to zero energy, we consider the number of flavors near the upper boundary of the conformal window. In this flavor-number regime the theory develops a perturbative infrared interacting fixed point. These results show that PMC ∞ leads to higher precision and introduces new interesting features in the PMC. In fact, this method preserves with continuity the position of the peak, showing perfect agreement with the experimental data already at NNLO. We also show a detailed comparison of the PMC ∞ with the other PMC approaches: the multi-scale-setting approach (PMCm) and the single-scale-setting approach (PMCs) by comparing their predictions for three important fully integrated quantities R e+e- , R$_Τ$ and Γ (H→$b\bar{b}$) up to the four-loop accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gene expression analysis of precision-cut human liver slices indicates stable expression of ADME-Tox related genes

In the process of drug development it is of high importance to test the safety of new drugs with predictive value for human toxicity. A promising approach of toxicity testing is based on shifts in gene expression profiling of the liver. Toxicity screening based on animal liver cells cannot be directly extrapolated to humans due to species differences. The aim of this study was to evaluate precision-cut human liver slices as in vitro method for the prediction of human specific toxicity by toxicogenomics. The liver slices contain all cell types of the liver in their natural architecture. This is important since drug-induced toxicity often is a multi-cellular process. Previously we showed that toxicogenomic analysis of rat liver slices is highly predictive for rat in vivo toxicity. In this study we investigated the levels of gene expression during incubation up to 24 h with Affymetrix microarray technology. The analysis was focused on a broad spectrum of genes related to stress and toxicity, and on genes encoding for phase-I, -II and -III metabolizing enzymes and transporters. Observed changes in gene expression were associated with cytoskeleton remodeling, extracellular matrix and cell adhesion, but for the ADME-Tox related genes only minor changes were observed. PCA analysis showed that changes in gene expression were not associated with age, sex or source of the human livers. Slices treated with acetaminophen showed patterns of gene expression related to its toxicity. These results indicate that precision-cut human liver slices are relatively stable during 24 h of incubation and represent a valuable model for human in vitro hepatotoxicity testing despite the human inter-individual variability.

60 APPLIED LIFE SCIENCES↗

Precision-cut liver slices as a model for the early onset of liver fibrosis to test antifibrotic drugs

Induction of fibrosis during prolonged culture of precision-cut liver slices (PCLS) was reported. In this study, the use of rat PCLS was investigated to further characterize the mechanism of early onset of fibrosis in this model and the effects of antifibrotic compounds. Rat PCLS were incubated for 48 h, viability was assessed by ATP and gene expression of PDGF-B and TGF-β1 and the fibrosis markers Hsp47, αSma and Pcol1A1 and collagen1 protein expressions were determined. The effects of the antifibrotic drugs imatinib, sorafenib and sunitinib, PDGF-pathway inhibitors, and perindopril, valproic acid, rosmarinic acid, tetrandrine and pirfenidone, TGFβ-pathway inhibitors, were determined. After 48 h of incubation, viability of the PCLS was maintained and gene expression of PDGF-B was increased while TGF-β1 was not changed. Hsp47, αSma and Pcol1A1 gene expressions were significantly elevated in PCLS after 48 h, which was further increased by PDGF-BB and TGF-β1. The increased gene expression of fibrosis markers was inhibited by all three PDGF-inhibitors, while TGFβ-inhibitors showed marginal effects. The protein expression of collagen 1 was inhibited by imatinib, perindopril, tetrandrine and pirfenidone. In conclusion, the increased gene expression of PDGF-B and the down-regulation of fibrosis markers by PDGF-pathway inhibitors, together with the absence of elevated TGF-β1 gene expression and the limited effect of the TGFβ-pathway inhibitors, indicated the predominance of the PDGF pathway in the early onset of fibrosis in PCLS. PCLS appear a useful model for research of the early onset of fibrosis and for testing of antifibrotic drugs acting on the PDGF pathway. - Highlights: • During culture, fibrosis markers increased in precision-cut liver slices (PCLS). • Gene expression of PDGF-β was increased, while TGFβ was not changed in rat PCLS. • PDGF-pathway inhibitors down-regulated this increase of fibrosis markers. • TGFβ-pathway inhibitors had only minor effects on fibrosis markers. • Rat PCLS can be used to study the early onset of fibrosis.

60 APPLIED LIFE SCIENCES↗

Applicability of rat precision-cut lung slices in evaluating nanomaterial cytotoxicity, apoptosis, oxidative stress, and inflammation

The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO{sub 2}, ZnO, CeO{sub 2}, SiO{sub 2}, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO{sub 2} NMs, CeO{sub 2} NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO{sub 2} NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO{sub 2} NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO{sub 2} only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization. - Highlights: • 16 OECD reference nanomaterials were tested in rat precision-cut lung slices. • Nanomaterial cytotoxicity, apoptose, oxidative stress, and inflammation were detected. • Investigating these early effects is not sufficient to predict in vivo outcome. • Reproducibility was not fully satisfactory in the glutathione and cytokine assays. • Further work is required to adjust effective dosages in vitro to in vivo doses.

60 APPLIED LIFE SCIENCES↗

The exit-wave power-cepstrum transform for scanning nanobeam electron diffraction: robust strain mapping at subnanometer resolution and subpicometer precision

Scanning nanobeam electron diffraction (NBED) with fast pixelated detectors is a valuable technique for rapid, spatially resolved mapping of lattice structure over a wide range of length scales. However, intensity variations caused by dynamical diffraction and sample mistilts can hinder the measurement of diffracted disk centers as necessary for quantification. Robust data processing techniques are needed to provide accurate and precise measurements for complex samples and non-ideal conditions. Here we present an approach to address these challenges using a transform, called the exit wave power cepstrum (EWPC), inspired by cepstral analysis in audio signal processing. The EWPC transforms NBED patterns into real-space patterns with sharp peaks corresponding to inter-atomic spacings. We describe a simple analytical model for interpretation of these patterns that cleanly decouples lattice information from the intensity variations in NBED patterns caused by tilt and thickness. With tracking the inter-atomic spacing peaks in EWPC patterns, strain mapping is demonstrated for two practical applications: mapping of ferroelectric domains in epitaxially strained PbTiO 3 films and mapping of strain profiles in arbitrarily oriented core-shell Pt-Co nanoparticle fuel-cell catalysts. The EWPC transform enables lattice structure measurement at sub-pm precision and sub-nm resolution that is robust to small sample mistilts and random orientations.

42 ENGINEERING↗

Accessing Atomic-scale Phosphorus Dopant Distribution in Precise Silicon Devices by Advanced STEM Imaging and Spectroscopy

The structural and chemical characterization at the atomic-scale plays a critical role in understanding the structure-property relationship in precise electrical devices such as those produced by atomic-precision advanced manufacturing (APAM). APAM, utilizing hydrogen lithography in a scanning tunneling microscope, offers a potential pathway to ultra-efficient transistors, and has been developed to produce phosphorus (P)-based donor devices integrated into bare Si substrates. Structural characterization of the buried, Si with P dopant (Si:P) delta-layer in the devices by scanning transmission electron microscopy (STEM), however, is a challenge due to similar atomic number and low concentration of the P dopants. In this paper, we describe several efforts of utilizing advanced STEM imagining and spectroscopic techniques to quantify the Si:P deltalayers. STEM imaging combining low-angle and high-angle annular dark-field (LAADF, HAADF) detectors as well as atomic-scale elemental mapping using energy-dispersive X-ray spectroscopy (EDS) are used to reveal the P and defect distribution across the delta-layer processed under various thermal conditions.

47 OTHER INSTRUMENTATION↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Precision Loading and Delivery of Molecular Cargo by Size-Controlled Coacervation of Gold Nanoparticles Functionalized with Elastin-like Peptides

Thermoresponsive elastin-like peptides (ELPs) have been extensively investigated in biotechnology and medicine, but little attention has been paid to the process by which coacervation causes ELP-decorated particles to aggregate. Here, using gold nanoparticles (AuNPs) functionalized with a cysteine-terminated 96-repeat of the VPGVG sequence (V96-Cys), we show that the size of the clusters that reversibly form above the ELP transition temperature can be finely controlled in the 250 to 930 nm range by specifying the concentration of free V96-Cys in solution and using AuNPs of different sizes. We further find that the localized surface plasmon resonance peak of the embedded AuNPs progressively red-shifts with cluster size, likely due to an increase in particle–particle contacts. We exploit this fine control over size to homogeneously load precise amounts of the dye Nile Red and the antibiotic Tetracycline into clusters of different hydrodynamic diameters and deliver cargos near-quantitatively by deconstructing the aggregates below the ELP transition temperature. Beyond establishing a key role for free ELPs in the agglomeration of ELP-functionalized particles, our results provide a path for the thermally controlled delivery of precise quantities of molecular cargo. This capability might prove useful in combination photothermal therapies and theranostic applications, and to trigger spatially and temporally uniform responses from biological, electronic, or optical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorine-Free Precise Polymer Electrolyte for Efficient Proton Transport: Experiments and Simulations

Designing polymers with controlled nanoscale morphologies and scalable synthesis is of great interest in the development of fluorine-free materials for proton-exchange membranes in fuel cells. This study focuses on a precision polyethylene with phenylsulfonic acid branches at every fifth carbon, p5PhSA, with a high ion-exchange capacity (4.2 mmol/g). The polymers self-assemble into hydrophilic and hydrophobic co-continuous nanoscale domains. In the hydrated state, the hydrophilic domain, composed of polar sulfonic acid moieties and water, serves as a pathway for efficient mesoscopic proton conductivity. The morphology and proton transport of p5PhSA are evaluated under hydrated conditions using in situ X-ray scattering and electrochemical impedance spectroscopy techniques. Additionally, at 40 °C and 95% relative humidity, the proton conductivity of p5PhSA is 0.28 S/cm, which is four times greater than Nafion 117 under the same conditions. Atomistic molecular dynamics (MD) simulations are also used to elucidate the interplay between the structure and the water dynamics. The MD simulations show strong nanophase separation between the percolated hydrophilic and hydrophobic domains over a wide range of water contents. The percolated hydrophilic nanoscale domain facilitates the rapid proton transport in p5PhSA and demonstrates the potential of precise hydrocarbon-based polymers as processible and effective proton-exchange membranes.