Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Effect of probe configuration on radiative heating during Jovian entry

The radiative heating to the probe's surface and the effects of the recession of the heat shield caused by this heating are analyzed for five initial probe configurations for a Jovian entry. The initial configurations are spherically capped, conical bodies and hyperboloids. The results show that severe blunting of the nose region occurs for all configurations due to ablation of the heat shield caused by the large radiative heating rates. Recession at the nose region can possibly cause a concavity at the stagnation point. Furthermore, the recession of the heat shield, especially for the spherically capped, conical bodies, will be underpredicted if the change in the probe's shape during the entry is neglected in an analysis.

Sutton, K.↗

Flight characteristics of probes in the atmospheres of Mars, Venus, and the outer planets

Density, pressure, and temperature profiles of an unknown planetary atmosphere can be obtained from the high-speed entry of a probe provided the aerodynamic characteristics of the probe in this atmosphere are accurately known. An investigation of the effect of gas composition on probe aerodynamics has been conducted in the Ames Hypersonic Free Flight Facility by gun launching small-scale models into atmospheres representative of Mars, Venus, Jupiter, and Saturn. Aerodynamic data at conditions matching the velocity and Reynolds number at a number of points on the Viking trajectory (Mars) were obtained in both air and carbon dioxide and significant differences were noted. Aerodynamic data are also presented from tests in hydrogen and hydrogen-helium mixtures, gases which characterize the atmospheres of the outer planets.

Intrieri, P. F.↗

Preentry communications study. Outer planets atmospheric entry probe

A pre-entry communications study is presented for a relay link between a Jupiter entry probe and a spacecraft in hyperbolic orbit. Two generic communications links of interest are described: a pre-entry link to a spun spacecraft antenna, and a pre-entry link to a despun spacecraft antenna. The propagation environment of Jupiter is defined. Although this is one of the least well known features of Jupiter, enough information exists to reasonably establish bounds on the performance of a communications link. Within these bounds, optimal carrier frequencies are defined. The next step is to identify optimal relative geometries between the probe and the spacecraft. Optimal trajectories are established for both spun and despun spacecraft antennas. Given the optimal carrier frequencies, and the optimal trajectories, the data carrying capacities of the pre-entry links are defined. The impact of incorporating pre-entry communications into a basic post entry probe is then assessed. This assessment covers the disciplines of thermal control, power source, mass properties and design layout. A conceptual design is developed of an electronically despun antenna for use on a Pioneer class of spacecraft.

Hinrichs, C. A.↗

The 1981 Jupiter Orbiter Probe mission

Plans for the 1981 Jupiter Orbiter Probe (JOP) mission are presented in some detail. The need for a Jupiter entry probe, remote sensing of the planet, and an orbiter, in addition to flybys, is made clear. Launch hardware, using the Space Shuttle flight system and Interim Upper Stage, is described, along with scientific tasks laid out for the entry probe and the orbiter. Combined analysis of the Jovian magnetosphere and other orbiter missions calls for a two-part orbiter with one part spun and the other de-spun. Related design problems and solutions are described and diagrammed. Jovian moon flybys and orbiter path adjustments by subsequent earth-launched flybys are discussed. The importance of Jupiter data for solar system evolution and possible analysis of early stages of stellar evolution or of a binary system are also treated.

Moore, J. W.↗

Static-pressure probe for small geometries

Contoured pressure probe with static orifices located near tip is more effective than conventional probes in taking measurements in small high-Reynolds number geometries such as nozzles or flow inlets. Probe is less sensitive to pressure gradients and off axis variations in flow directions over short distances.

Pinckney, S. Z.↗

Recovery and radiation corrections and time constants of several sizes of shielded and unshielded thermocouple probes for measuring gas temperature

Performance characteristics were experimentally determined for several sizes of a shielded and unshielded thermocouple probe design. The probes are of swaged construction and were made of type K wire with a stainless steel sheath and shield and MgO insulation. The wire sizes ranged from 0.03- to 1.02-mm diameter for the unshielded design and from 0.16- to 0.81-mm diameter for the shielded design. The probes were tested through a Mach number range of 0.2 to 0.9, through a temperature range of room ambient to 1420 K, and through a total-pressure range of 0.03 to 0.2.2 MPa (0.3 to 22 atm). Tables and graphs are presented to aid in selecting a particular type and size. Recovery corrections, radiation corrections, and time constants were determined.

Glawe, G. E.↗

Criteria for the selection of focusing ultrasonic probes

The principles of operation employed in the focusing of a sound field are considered, taking into account the use of solid and liquid coupling media. The focusing limits for a given transducer are investigated. As a diffraction phenomenon, focusing is a function of the system dimensions, the frequency, and the sound velocity. The frequency and the material used for the lenses are in most cases determined in accordance with considerations regarding sound propagation. Changes in the focus are therefore effected mainly by the selection of transducer and lens dimensions. The functions of the focusing factor for a normal immersion probe and a direct contact angle probe are represented in graphs. The deviation of the appropriate parametric values for an ultrasonic probe is illustrated with the aid of examples.

Schlengermann, U.↗

Possible measurement of the coefficient of the second zonal harmonic of the sun's gravitational field with a solar probe

The use of radio tracking of a solar probe to estimate accurately the coefficient of the second zonal harmonic of the sun's gravitational field was examined. Preliminary results indicate that the coefficient can be estimated with a standard error of 10 to the minus 8th power or less, provided that the probe is equipped with a suitable drag-free system to compensate for the effects of non-gravitational accelerations. For signal paths that pass near the sun, dual-band ranging to the probe can provide the tracking accuracy needed to insure that the standard of error is equal to or less than 10 to minus 8th power. The possibility of achieving such accuracy with a single-band radio uplink and a dual-band downlink is discussed.

Reasenberg, R. D.↗

Solar probe studies of the solar convection zone

From a distance of 3 solar radii as may be attainable with a solar probe, a resolution of 5 arc second such as would be possible from a small telescope will allow observations of solar features as small as 50 km. Because the solar probe will be as close to the sun as 0.014.AU, the effective resolution is increased a factor of 70. A 3 inch telescope on the solar probe will have resolution equivalent to a 200 inch telescope on earth. Thus observations could be carried into the size scale which presumably is responsible for the turbulent viscosity. The preferred instrument for studying the dynamics of the solar convection zone is a magnetograph operated in a Doppler mode. A Fabrey-Perot etalon can provide the spectral discrimination necessary for the measurement of velocities. The instrument can provide long time base observations of the solar p-mode oscillations and permit determination of the rate of solar rotation at a depth 25% below the solar surface to an accuracy of better than 0.5 km/s.

Ulrich, R. K.↗

Time-resolved double-probe study in a He-Hg afterglow plasma

An experimental double-probe technique is described which allows the He(+) ion density to be measured directly as a function of time in the afterglow of a helium-metal-vapor discharge. As an application example, two CW laser transitions of the He-Hg(+) laser at 6150 and 7944 A are considered which both arise from excited 7p (2) P terms of Hg II. The time-resolved double-probe technique is used to measure the destruction rate of the He(+) ion density, which is then compared with the spontaneous-emission decay rate for 7p (2) P terms of Hg II. The results obtained show unambiguously and directly that the dominant excitation process for the two transitions considered is a charge-transfer collisional reaction of the form He(+) plus Hg yields He plus metastable Hg(+) plus the energy defect for this reaction. It is noted that the time-resolved double-probe technique may provide a simple method for measuring ion mobilities in a multi-ion plasma.

Shay, T.↗

Jupiter Orbiter and Probe project - Synthesis of the mission design

The Jupiter Orbiter Probe (JOP), scheduled to be launched by the Shuttle IUS in 1981, is described in terms of its scientific mission objectives. These include: analysis of the chemical composition and physical state of Jupiter's atmosphere, the chemical composition and physical state of Ganymede and Callisto, and the topology and behavior of the magnetic field and energetic particle fluxes. Attention is given to an atmospheric probe which will be launched from the main probe, and to the navigation requirements necessary to 'bounce' the JOP around the Jovian moons.

Beckman, J. C.↗

Measurement of flow angle and mass flow rate in an unknown flow field using hot film and hot wire probes

A data reduction technique applicable to constant temperature hot film and hot wire probes is presented which is used to determine flow angle and mass flow rate in an unknown flow field over a wide range of flow conditions at supersonic and hypersonic velocities. The technique virtually eliminates the effect of Reynolds number on a probe's flow angle sensitivity. Methods for extrapolating a limited amount of mass flow rate calibration data to include the range of mass flow rate encountered in an experiment are also given. This technique has been applied to data obtained using a hot film probe during surveys in the leeside flow field of a space shuttle orbiter configuration.

Helms, V. T., III↗

Integral equation formulation for probe corrected far-field reconstruction from measurements on a cylinder

A method has been developed for far-field evaluation from measurements taken on a cylinder. The antenna and probe fields are represented by superpositions of plane waves, and two integral equations are derived whose functions are the elevation and azimuthal components of the antenna pattern. The known components are the measurements taken by either two probes or a single probe with two geometrical orientations. The convolutional nature of the integral equations makes Fourier analysis techniques applicable to a straightforward solution and an efficient computational procedure. Good agreement has been found between experimental and reconstructed patterns for both nominal and cross polarized field components.

Borgiotti, G. V.↗

The free shear layer tone phenomenon and probe interference

The reported investigation shows that the hot-wire probe induces stable upstream oscillations in a free shear layer, similar to the jet edge tone mechanism. This effect can be significant also in measurements involving large-scale organized structure, conditional sampling, space-time correlation, and convection velocity, when a reference or indicator probe may be used near the origin of the free shear layer. It appears that even in a free shear layer without any wedge, an object in the flow sufficiently downstream can also provide feedback to the flow upstream. A description is given of the edge-tone phenomenon which is observed when a thin slit jet impinges on a plane wedge. Attention is given to the free shear layer tone induced by a hot-wire probe, the free shear layer tone phenomenon, and shear layer tone eigenvalues and eigenfunctions.

Hussain, A. K. M. F.↗

A subcutaneous channeling probe for implanting long leads

The channeling probe described in the present paper was designed to overcome surgical problems of the type that were encountered when a multichannel radio transmitter had to be implanted in a cow. The probe was made of a flexible but sufficiently stiff 9.5-mm-diam nylon rod, consisting of 46-cm sections for convenience in sterilization and surgical handling. Stainless steel sleaves reinforced the threaded connecting joints. At one end, arrowhead-shaped channeling heads could be attached to produce wide channels for large sensors. The other end was tapered for narrow channels. Postoperative problems were not encountered in the use of this probe in cows, sheep, and dogs.

Lund, G. F.↗

Saturn orbiter dual probe mission

The described Saturn orbiter dual probe mission and spacecraft combines three systems into a multi-purpose Saturn exploration package. The spacecraft consists of: (1) Saturn orbiter; (2) Saturn probe; and (3) Titan probe or lander. This single spacecraft provides the capability to conduct in situ measurements of the Saturn and Titan atmospheres, and, possibly the Titan surface, as well as a variety of remote sensing measurements. The remote sensing capabilities will be used to study the surfaces, interiors and environments of Saturn's satellites, the rings of Saturn, Saturn's magnetosphere, and synoptic properties of Saturn's atmosphere.

Rudd, R. P.↗

Outer planet probe missions, designs and science

The similarities and differences of atmosphere entry probe mission designs and sciences appropriate to certain solar system objects, are reviewed. Candidate payloads for Saturn and Titan probes are suggested. Significant supporting research and technology efforts are required to develop mission-peculiar technology for probe exploration of the Saturnian system.

Colin, L.↗

Calorimeter probes for measuring high thermal flux

Expendable, slug-type calorimeter probes were developed for measuring high heat-flux levels of 10-30 kW/sq cm in electric-arc jet facilities. The probes were constructed with thin tungsten caps mounted on Teflon bodies. The temperature of the back surface of the tungsten cap is measured, and its time rate of change gives the steady-state absorbed heat flux as the calorimeter probe heats to destruction when inserted into the arc jet. Design, construction, test, and performance data are presented.

Russell, L. D.↗