Model deformation system
The development of a system to measure model deflections encountered in the National Transonic Facility is discussed. The goal is to be able to measure peak deflections of up to 3 in. with accuracies to within 0.0025 in. over an area 1 m square as the model pitches through an included angle of 30 deg. Stereophotogrammetric techniques are being implemented, with the initial system being an extension of standard techniques. A second system, which will be all electronic, is under development. Both techniques require targets to be strategically placed on the model. Active targets are being developed for location in the model in order to maximize the signal-to-noise ratio and to approximate a point source. Image processing techniques and stereophotogrammetric data reduction programs are being implemented to perform the data reduction tasks.