Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Creating Accurate Methane Emission Inventories through Data-Driven Airborne Survey Strategies

Because natural gas emits less carbon than other fossil fuels, it holds promise as a green energy transition fuel. However, the overall carbon footprint of natural gas is significantly elevated by methane emissions that occur during its production and transmission (Cusworth et al. 2022). Methane “super-emitters,” while comprising only about 1% of sites, are responsible for the majority of oil- and gas-sourced methane emissions, making their detection and mitigation critical in reducing the climate impact of natural gas and in meeting national and global sustainability goals (Sherwin et al. 2024). Yet, despite advancements in detection, significant uncertainties remain regarding the size, frequency, and duration distributions of methane emissions (e.g., Frankenberg et al. 2016, Cusworth et al. 2022, Chen, Sherwin et al. 2022, Conrad et al. 2023, Johnson et al. 2023, Sherwin et al. 2024) underscoring the need for comprehensive emissions inventories segmented by basin across the US. Airborne surveys are well-suited for collecting data to build these comprehensive, basin-level inventories because they allow for extensive spatial coverage, and have the spatial resolution, and the sensitivity to pinpoint individual methane sources. As remote sensing technologies enable rapid basin-scale surveys, it is imperative to establish scientifically and statistically robust standards to generate reliable and actionable emissions inventories. Recent work has shown that differences in airborne sampling strategies, detection technologies, and analysis can lead to large differences between survey conclusions if not correctly accounted for (Chen et al. 2024). This elevates the importance of incorporating proper sampling and analysis techniques when designing a methane emissions monitoring campaign to produce accurate results and facilitate cross-study comparisons. In this paper, we describe a survey strategy designed using the latest conclusions from the literature to align results from different aerial surveys. We identify several sampling and analysis principles, including large sample sizes, balanced sampling across oil and gas production, careful survey area definition, and a unified protocol for analysis, to be vital to producing an unbiased estimate of basin-scale emissions. We present results from a Department of Energy-funded project that deployed this survey strategy in two understudied oil and gas- producing regions in the United States: the Haynesville Basin in Texas and Louisiana, and the Woodford Shale in the Anadarko Basin in Oklahoma.

03 NATURAL GAS↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

The Industry's Long-term, Yet Near-term, Issues: The Need for Radiation Protection Professionals - 20266

Since the discovery of X-rays and radioactivity, the civil use of nuclear technology has thrived for more than a half-century and has matured to be safer and more efficient. A balance between radiological and non-radiological knowledge and experience has been gained and retained through the years. Nevertheless, a slowly developing gap has emerged during the past few decades. National and international data show a declining trend in the existence of health physics programs and associated enrollment and training, which directly impact the pipeline of radiation professionals (i.e., educators, technicians, researchers, and regulators). This decline can be attributed to many factors including the lack of scientific inquisitiveness, declining funding, and the perception that existing protocols are sufficiently protective. Decommissioning and dismantling nuclear facilities is a complex and multi-phased process that generates large quantities of various levels of radioactive waste. With multiple facilities reaching their end of operational life, and others being shut down for economic reasons, the current pipeline for radiation protection experts cannot meet the future's need. Consequently, international organizations have proposed a variety of programs to transfer knowledge of radiation protection principles and practice. While many change-oriented efforts to counteract this trend aim to promote mobility, this is just a partial solution to the actual issue: long-term availability. This paper suggests multidisciplinary collaborations with modern technologies as a path forward to educate young professionals on the diversity of radiation-related applications to retain expert knowledge and foster innovation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-A-201-00: Image Guidance Technologies and Management Strategies

Recent years have seen a widespread proliferation of available in-room image guidance systems for radiation therapy target localization with many centers having multiple in-room options. In this session, available imaging systems for in-room IGRT will be reviewed highlighting the main differences in workflow efficiency, targeting accuracy and image quality as it relates to target visualization. Decision-making strategies for integrating these tools into clinical image guidance protocols that are tailored to specific disease sites like H&N, lung, pelvis, and spine SBRT will be discussed. Learning Objectives: Major system characteristics of a wide range of available in-room imaging systems for IGRT. Advantages / disadvantages of different systems for site-specific IGRT considerations. Concepts of targeting accuracy and time efficiency in designing clinical imaging protocols.

60 APPLIED LIFE SCIENCES↗

Emulation of complex open quantum systems using superconducting qubits

With quantum computers being out of reach for now, quantum simulators are alternative devices for efficient and accurate simulation of problems that are challenging to tackle using conventional computers. Quantum simulators are classified into analog and digital, with the possibility of constructing “hybrid” simulators by combining both techniques. Here we focus on analog quantum simulators of open quantum systems and address the limit that they can beat classical computers. In particular, as an example, we discuss simulation of the chlorosome light-harvesting antenna from green sulfur bacteria with over 250 phonon modes coupled to each electronic state. Furthermore, we propose physical setups that can be used to reproduce the quantum dynamics of a standard and multiple-mode Holstein model. The proposed scheme is based on currently available technology of superconducting circuits consist of flux qubits and quantum oscillators.

97 MATHEMATICS AND COMPUTING↗

Nonlocal hyperconcentration on entangled photons using photonic module system

Entanglement distribution will inevitably be affected by the channel and environment noise. Thus distillation of maximal entanglement nonlocally becomes a crucial goal in quantum information. Here we illustrate that maximal hyperentanglement on nonlocal photons could be distilled using the photonic module and cavity quantum electrodynamics, where the photons are simultaneously entangled in polarization and spatial-mode degrees of freedom. The construction of the photonic module in a photonic band-gap structure is presented, and the operation of the module is utilized to implement the photonic nondestructive parity checks on the two degrees of freedom. We first propose a hyperconcentration protocol using two identical partially hyperentangled initial states with unknown coefficients to distill a maximally hyperentangled state probabilistically, and further propose a protocol by the assistance of an ancillary single photon prepared according to the known coefficients of the initial state. In the two protocols, the total success probability can be improved greatly by introducing the iteration mechanism, and only one of the remote parties is required to perform the parity checks in each round of iteration. Estimates on the system requirements and recent experimental results indicate that our proposal is realizable with existing or near-further technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep compressed seismic learning for fast location and moment tensor inferences with natural and induced seismicity

Fast detection and characterization of seismic sources is crucial for decision-making and warning systems that monitor natural and induced seismicity. However, besides the laying out of ever denser monitoring networks of seismic instruments, the incorporation of new sensor technologies such as Distributed Acoustic Sensing (DAS) further challenges our processing capabilities to deliver short turnaround answers from seismic monitoring. In response, this work describes a methodology for the learning of the seismological parameters: location and moment tensor from compressed seismic records. In this method, data dimensionality is reduced by applying a general encoding protocol derived from the principles of compressive sensing. The data in compressed form is then fed directly to a convolutional neural network that outputs fast predictions of the seismic source parameters. Thus, the proposed methodology can not only expedite data transmission from the field to the processing center, but also remove the decompression overhead that would be required for the application of traditional processing methods. An autoencoder is also explored as an equivalent alternative to perform the same job. We observe that the CS-based compression requires only a fraction of the computing power, time, data and expertise required to design and train an autoencoder to perform the same task. Implementation of the CS-method with a continuous flow of data together with generalization of the principles to other applications such as classification are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Minimizing Fraud in the Carbon Offset Market Using Blockchain Technologies

Fraud in the Environmental Benefit Credit (EBC) markets is pervasive. To make matters worse, the cost of creating EBCs is often higher than the market price. Consequently, a method to create, validate, and verify EBCs and their relevance is needed to mitigate fraud. The EBC market has focused on geologic (fossil fuel) CO 2 sequestration projects that are often over budget and behind schedule and has failed to capture the "lowest hanging fruit" EBCs - terrestrial sequestration via the agricultural industry. This project reviews a methodology to attain possibly the least costly EBCs by tracking the reduction of inputs required to grow crops. The use of bio- stimulant products, such as humate, allows a farmer to use less nitrogen without adversely affecting crop yield. Using less nitrogen qualifies for EBCs by reducing nitrous oxide emissions and nitrate runoff from a farmer's field. A blockchain that tracks the bio-stimulant material from source to application provides a link between a tangible (bio-stimulant commodity) and the associated intangible (EBCs) assets. Covert insertion of taggants in the bio-stimulant products creates a unique barcode that allows a product to be digitally tracked from beginning to end. This process (blockchain technology) is so robust, logical, and transparent that it will enhance the value of the associated EBCs by mitigating fraud. It provides a real time method for monetizing the benefits of the material. Substantial amounts of energy are required to produce, transport, and distribute agricultural inputs including fertilizer and water. Intelligent optimization of the use of agricultural inputs can drive meaningful cost savings. Tagging and verification of product application provides a valuable understanding of the dynamics in the water/food energy nexus, a major food security and sustainability issue. As technology in agriculture evolves so to must methods to verify the Enterprise Resource Planning (ERP) potential of innovative solutions. The technology reviewed provides the ability to combine blockchain and taggants ("taggant blockchains") as the engine by which to (1) mitigate fraudulent carbon credits; (2) improve food chain security, and (3) monitor and manage sustainability. The verification of product quality and application is a requirement to validate benefits. Recent upgrades to humic and fulvic quality protocols known as ISO CD 19822 TC134 offers an analytical procedure. This work has been assisted by the Humic Products Trade Association and International Humic Substance Society. In addition, providing proof of application of these products and verification of the correct application of prescriptive humic and bio-stimulant products is required. Individual sources of humate have unique and verifiable characteristics. Additionally, methods for prescription of site- specific agricultural inputs in agricultural fields are available. (See US Patents 734867B2, US 90658633B2.) Finally, a method to assure application rate is required through the use of taggants. Sensors using organic solid to liquid phase change nanoparticles of various types and melting temperatures added to the naturally occurring materials provide a barcode. Over 100 types of nanoparticles exist ensuring numerous possible barcodes to reduce industry fraud. Taggant materials can be collected from soil samples of plant material to validate a blockchain of humic, fulvic and other soil amendment products. Other non-organic materials are also available as taggants; however, the organic tags are biodegradable and safe in the environment allowing for use during differing application timeliness.

54 ENVIRONMENTAL SCIENCES↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

Current Brachytherapy Quality Assurance Guidance: Does It Meet the Challenges of Emerging Image-Guided Technologies?

In the past decade, brachytherapy has shifted from the traditional surgical paradigm to more modern three-dimensional image-based planning and delivery approaches. The role of intraoperative and multimodality image-based planning is growing. Published American Association of Physicists in Medicine, American College of Radiology, European Society for Therapeutic Radiology and Oncology, and International Atomic Energy Agency quality assurance (QA) guidelines largely emphasize the QA of planning and delivery devices rather than processes. These protocols have been designed to verify compliance with major performance specifications and are not risk based. With some exceptions, complete and clinically practical guidance exists for sources, QA instrumentation, non-image-based planning systems, applicators, remote afterloading systems, dosimetry, and calibration. Updated guidance is needed for intraoperative imaging systems and image-based planning systems. For non-image-based brachytherapy, the American Association of Physicists in Medicine Task Group reports 56 and 59 provide reasonable guidance on procedure-specific process flow and QA. However, improved guidance is needed even for established procedures such as ultrasound-guided prostate implants. Adaptive replanning in brachytherapy faces unsolved problems similar to that of image-guided adaptive external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Communication Networks for Energy Applications: Review and Perspective

Abstract The energy sector is expected to undergo significant changes in the coming decades with the advent of new technologies, including smart grid development, microgrid expansion, increasing electric vehicle and renewable energy usage, and enhanced measures to minimize greenhouse gas emission, among others. In tandem, these changes are expected to create new opportunities for the deployment of quantum technologies within the energy sector. Building on the authors' previous reviews on the current state of and future opportunities for quantum sensing, quantum computing and quantum simulations for energy sector applications, this work provides an overview of recent progress in quantum networking and communications for the energy industry, with a focus on platforms, devices, and protocols, including quantum teleportation and quantum key distribution. Specific areas of relevance to the energy sector are then analyzed, including the role of quantum networks for greenhouse gas monitoring, secure data collection and transmission in smart grids, nuclear power plants’ safety, facilitating oil and gas exploration, and other energy‐relevant applications. This review concludes with a brief overview of areas for future innovation, including the need for platforms for simulating quantum networks, quantum material and platform design, and computational approaches to accelerate quantum protocol discovery and development.

Paudel, Hari P.↗

Wavelets in medical imaging

The aim of this study is to provide emerging applications of wavelet methods to medical signals and images, such as electrocardiogram, electroencephalogram, functional magnetic resonance imaging, computer tomography, X-ray and mammography. Interpretation of these signals and images are quite important. Nowadays wavelet methods have a significant impact on the science of medical imaging and the diagnosis of disease and screening protocols. Based on our initial investigations, future directions include neurosurgical planning and improved assessment of risk for individual patients, improved assessment and strategies for the treatment of chronic pain, improved seizure localization, and improved understanding of the physiology of neurological disorders. We look ahead to these and other emerging applications as the benefits of this technology become incorporated into current and future patient care. In this chapter by applying Fourier transform and wavelet transform, analysis and denoising of one of the important biomedical signals like EEG is carried out. The presence of rhythm, template matching, and correlation is discussed by various method. Energy of EEG signal is used to detect seizure in an epileptic patient. We have also performed denoising of EEG signals by SWT.

60 APPLIED LIFE SCIENCES↗

Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage for several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mild Catalytic methods for Alkyl-Alkyl Bond Formation

Overview of Research Goals and Accomplishments for the Period 07/01/06 – 06/30/07: Our overall research goal is to transform the rapidly emerging synthetic chemistry involving alkyl-alkyl cross-couplings into more of a mechanism-based field so that that new, rationally-designed catalysts can be performed under energy efficient conditions. Our specific objectives for the previous year were 1) to obtain a proper electronic description of an active catalyst for alkyl-alkyl cross-coupling reactions and 2) to determine the effect of ligand structure on the rate, scope, selectivity, and functional group compatibility of C(sp3)-C(sp3) cross-coupling catalysis. We have completed both of these initial objectives and established a firm base for further studies. The specific significant achievements of the current grant period include: 1) we have performed magnetic and computational studies on (terpyridine)NiMe, an active catalyst for alkyl-alkyl cross couplings, and have discovered that the unpaired electron resides heavily on the terpyridine ligand and that the proper electronic description of this nickel complex is a Ni(II)-methyl cation bound to a reduced terpyridine ligand; 2) we have for the first time shown that alkyl halide reduction by terpyridyl nickel catalysts is substantially ligand based; 3) we have shown by isotopic labeling studies that the active catalyst (terpyridine)NiMe is not produced via a mechanism that involves the formation of methyl radicals when (TMEDA)NiMe2 is used as the catalyst precursor; 4) we have performed an extensive ligand survey for the alkyl-alkyl cross-coupling reactions and have found that electronic factors only moderately influence reactivity in the terpyridine-based catalysis and that the most dramatic effects arise from steric and solubility factors; 5) we have found that the use of bis(dialkylphosphino)methanes as ligands for nickel does not produce active catalysts for cross-coupling but rather leads to bridging hydride complexes of varying geometries; 6) we have determined that the geometry of aforementioned bridging hydride complexes is largely determined by external forces such as hydrogen bonding interactions and crystal packing forces; 7) we have found that the rate of reductive elimination of alkane from a (pyridyl-2-pyrrolide)AuMe2 complex is severely inhibited due to the rigid geometry of the pyridyl-2-pyrrolide ligand; 8) we have prepared, structurally characterized, and explored the reactivity of 1-adamantylzinc reagents as model nucleophiles for sterically challenging alkyl-alkyl cross-coupling reactions. The continued success of this work will lead to alkyl-alkyl cross-coupling catalysts with broad scope and selectivities. The work has potential to significantly impact science and technologies of interest to the DOE as the chemistry is focused on developing useful reactions using reagents that can be directly prepared from petroleum and natural gas feedstocks. Moreover, the developing synthetic chemistry can profoundly affect the way materials, fine chemicals, and drugs are made. Since the methodology we are developing can shorten existing synthetic protocols, proceed at room temperature, and operate under environmentally benign conditions, it can greatly reduce energy expenditures, especially considering the contribution of the chemical manufacturing field to the gross domestic product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature‐Dependent Crystallization in Two‐Step Perovskite Deposition Revealed by In Situ GIWAXS and Machine Learning‐Guided Analysis

The performance and stability of perovskite solar cells are strongly governed by the crystallization behavior of their active layer. In two-step sequential deposition, early-stage film formation plays a decisive role in determining final phase purity and device quality. Guided by a data-driven analysis of nearly 39 000 devices in the FAIR perovskite database, we identified solvent-mediated quenching and thermal processing as key variables affecting power conversion efficiency (PCE), particularly in two-step fabrication. Here, to investigate these effects in real time, we designed and implemented a custom-built, temperature-controlled spin-coating system, enabling precise thermal modulation during precursor deposition. Using this platform, we performed in situ GIWAXS measurements to study the crystallization dynamics of FA 0.5 MA 0.5 PbI 3 films over a temperature range of 30°C–90°C. Our results reveal a non-monotonic relationship between spin-coating temperature and α-phase formation, governed by the interplay between precursor interdiffusion, PbI 2 crystallinity, and δ-phase suppression. The custom thermal control enabled us to isolate and quantify these competing effects during the earliest stages of film formation, providing mechanistic insight into how spin-coating temperature governs both phase purity and kinetic pathways in two-step perovskite systems. Temperature-dependent SEM and photovoltaic device measurements further demonstrate that early-stage crystallization pathways directly translate into differences in morphology, charge-transport continuity, and device performance. These findings inform targeted strategies for optimizing deposition protocols to balance rapid nucleation, phase stability, and device performance.

Saadawy, Ahmed [King Fahd University of Petroleum ↗

Caveats and limitations of plate reader-based high-throughput kinetic measurements of intracellular calcium levels

Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca{sup 2+} concentration ([Ca{sup 2+}]{sub i}) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca{sup 2+}]{sub i}, e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca{sup 2+}]{sub i} are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca{sup 2+}]{sub i} in plate reader systems, though the results of such plate reader-based measurements have been questioned. In view of the increasing use of plate reader systems for measurements of [Ca{sup 2+}]{sub i} a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca{sup 2+}]{sub i}. Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with caveats and limitations that require further investigation. - Research Highlights: > The use of plate readers for high-throughput screening of intracellular Ca{sup 2+} is associated with many pitfalls and limitations. > Single cell fluorescent microscopy is recommended for measurements of intracellular Ca{sup 2+}. > Dual-wavelength dyes (Fura-2) are preferred over single-wavelength dyes (Fluo-4) for measurements of intracellular Ca{sup 2+}. > Probenecid prevents dye leakage but abolishes depolarization-evoked Ca{sup 2+} influx, severely hampering measurements of Ca{sup 2+}. > In general, care should be taken when interpreting data from high-throughput kinetic measurements.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-01: Absorbed Dose Rate-To-Water at the Surface of a Beta-Emitting Planar Ophthalmic Applicator with a Planar, Windowless Extrapolation Chamber

Purpose: Currently there is no primary calibration standard for determining the absorbed dose rate-to-water at the surface of β-emitting concave ophthalmic applicators and plaques. Machining tolerances involved in the design of concave window extrapolation chambers are a limiting factor for development of such a standard. Use of a windowless extrapolation chamber avoids these window-machining tolerance issues. As a windowless extrapolation chamber has never been attempted, this work focuses on proof of principle measurements with a planar, windowless extrapolation chamber to verify the accuracy in comparison to initial calibration, which could be extended to the design of a hemispherical, windowless extrapolation chamber. Methods: The window of an extrapolation chamber defines the electrical field, aids in aligning the source parallel to the collector-guard assembly, and decreases the backscatter due to attenuation of lower electron energy. To create a uniform and parallel electric field in this research, the source was made common to the collector-guard assembly. A precise positioning protocol was designed to enhance the parallelism of the source and collector-guard assembly. Additionally, MCNP5 was used to determine a backscatter correction factor to apply to the calibration. With these issues addressed, the absorbed dose rate-to-water of a Tracerlab 90Sr planar ophthalmic applicator was determined using National Institute of Standards and Technology's (NIST) calibration formalism, and the results of five trials with this source were compared to measurements at NIST with a traditional extrapolation chamber. Results: The absorbed dose rate-to-water of the planar applicator was determined to be 0.473 Gy/s ±0.6%. Comparing these results to NIST's determination of 0.474 Gy/s yields a −0.6% difference. Conclusion: The feasibility of a planar, windowless extrapolation chamber has been demonstrated. A similar principle will be applied to developing a primary calibration standard for concave applicators and plaques. This research is funded by the customers of the University of Wisconsin Accredited Dosimetry Calibration Laboratory.

07 ISOTOPE AND RADIATION SOURCES↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗