Search NASA⌕ Search

SEARCH · Search NASA

Results for “separability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Progress on observations of interspecies ion separation in inertial-confinement-fusion implosions via imaging x-ray spectroscopy

We report on the analyses of x-ray-imaging spectroscopy data from experiments to study interspecies ion separation in direct-drive inertial-confinement-fusion experiments on the Omega laser facility. This is a continuation of recent, related research [S. C. Hsu et al., Euro Phys. Lett. 115, 65001 (2016); T. R. Joshi et al., Phys. Plasmas 24, 056305 (2017)]. The targets were argon (Ar)-doped, deuterium (D2)-filled spherical plastic shells of varying D2-Ar relative and total gas pressures. We used a time- and space-integrated spectrometer, streaked crystal spectrometer, and up to three time-gated multi-monochromatic x-ray imagers (MMIs) fielded along different lines of sight to record x-ray spectral features obtained from the implosions. The MMI data were recorded between first-shock convergence and slightly before the neutron bang time. We confirm the presence of interspecies ion separation as reported in our recent work. Extensions to the previous work include (a) the inclusion of shell mix in the data analysis, which slightly changes the amount of inferred species separation, (b) observation of species separation closer to the neutron bang time, and (c) fielding of the particle x-ray temporal diagnostic (PXTD) [H. Sio et al., Rev. Sci. Instrum. 87, 11D701 (2016)] to infer the relative timing between the neutron bang time and peak x-ray emission. Experimentally inferred species separation is compared with radiation-hydrodynamic simulations that include a multi-ion-species transport model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of particle arrays on phase separation composition patterns

We examine the symmetry-breaking effect of fixed constellations of particles on the surface-directed spinodal decomposition of binary blends in the presence of particles whose surfaces have a preferential affinity for one of the components. Our phase-field simulations indicate that the phase separation morphology in the presence of particle arrays can be tuned to have a continuous, droplet, lamellar, or hybrid morphology depending on the interparticle spacing, blend composition, and time. In particular, when the interparticle spacing is large compared to the spinodal wavelength, a transient target pattern composed of alternate rings of preferred and non-preferred phases emerges at early times, tending to adopt the symmetry of the particle configuration. We reveal that such target patterns stabilize for certain characteristic length, time, and composition scales characteristic of the pure phase-separating mixture. To illustrate the general range of phenomena exhibited by mixture-particle systems, we simulate the effects of single-particle, multi-particle, and cluster–particle systems having multiple geometrical configurations of the particle characteristic of pattern substrates on phase separation. Our simulations show that tailoring the particle configuration, or substrate pattern configuration, a relative fluid-particle composition should allow the desirable control of the phase separation morphology as in block copolymer materials, but where the scales accessible to this approach of organizing phase-separated fluids usually are significantly larger. Limited experiments confirm the trends observed in our simulations, which should provide some guidance in engineering patterned blend and other mixtures of technological interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

A METHOD FOR SEPARATING CORONAL MASS EJECTIONS FROM THE QUIESCENT CORONA

A method for separating coronal mass ejections (CMEs) from the quiescent corona in white-light coronagraph images is presented. Such a separation allows the study of CME structure, as well as enabling a study of the quiescent coronal structure, without contamination by the CME. The fact that the large-scale quiescent corona is very close to radial, whilst CMEs are highly non-radial, enables the separation of the two components. The method is applied to Large Angle Spectrometric Coronagraph/Solar and Heliospheric Observatory C2 and C3 observations, and is successful in revealing CME signal, faint CMEs and blobs, and dark rarefactions within a CME. The success of the separation is tested at solar minimum, a time when streamers are in general most non-radial. The technique is also compared to other commonly used methods. The separation method enables (1) the study of extremely faint CME structure, down to almost the noise level of the coronagraphs, (2) paves the way for automated categorization of CME internal structure, and (3) provides a cleaner basis for tomography of the quiescent corona, without contamination from CMEs.

79 ASTRONOMY AND ASTROPHYSICS↗

MILLIONS OF MULTIPLES: DETECTING AND CHARACTERIZING CLOSE-SEPARATION BINARY SYSTEMS IN SYNOPTIC SKY SURVEYS

The direct detection of binary systems in wide-field surveys is limited by the size of the stars' point-spread functions (PSFs). A search for elongated objects can find closer companions, but is limited by the precision to which the PSF shape can be calibrated for individual stars. Based on a technique from weak-lensing analysis, we have developed the BinaryFinder algorithm to search for close binaries by using precision measurements of PSF ellipticity across wide-field survey images. We show that the algorithm is capable of reliably detecting binary systems down to Almost-Equal-To 1/5 of the seeing limit, and can directly measure the systems' position angles, separations, and contrast ratios. To verify the algorithm's performance we evaluated 100,000 objects in Palomar Transient Factory (PTF) wide-field-survey data for signs of binarity, and then used the Robo-AO robotic laser adaptive optics system to verify the parameters of 44 high-confidence targets. We show that BinaryFinder correctly predicts the presence of close companions with a <11% false-positive rate, measures the detected binaries' position angles within 1 Degree-Sign to 4 Degree-Sign (depending on signal-to-noise ratio and separation), and separations within 25%, and weakly constrains their contrast ratios. When applied to the full PTF data set, we estimate that BinaryFinder will discover and characterize {approx}450,000 physically associated binary systems with separations <2 arcsec and magnitudes brighter than m{sub R} = 18. New wide-field synoptic surveys with high sensitivity and sub-arcsecond angular resolution, such as LSST, will allow BinaryFinder to reliably detect millions of very faint binary systems with separations as small as 0.1 arcsec.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast ground-state-to-ground-state separation of small ion crystals

Rapid separation of linear crystals of trapped ions into different subsets is critical for realizing trapped ion quantum computing architectures where ions are rearranged in trap arrays to achieve all-to-all connectivity between qubits. Here we introduce a general theoretical framework that can be used to describe the separation of same-species and mixed-species crystals into smaller subsets. The framework relies on an efficient description of the evolution of Gaussian motional states under quadratic Hamiltonians that only requires a special solution of the classical equations of motion of the ions to describe their quantum evolution under the influence of a time-dependent applied potential and the ions' mutual Coulomb repulsion. We provide time-dependent applied potentials suitable for separation of a mixed-species three-ion crystal on timescales similar to that of free expansion driven by Coulomb repulsion, with all modes along the crystal axis starting and ending close to their ground states. Three separately confined mixed-species ions can be combined into a crystal held in a single well without energy gain by time-reversal of this separation process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Separability criteria for continuous-variable systems

A general separability condition on the second moment (covariance matrix) for continuous-variable two-party systems is derived by an analysis analogous to the derivation of Kennard's uncertainty relation without referring to the non-negativity of the partially transposed density matrix. This separability criterion is generally more stringent than that used by Simon which is based on the non-negativity of partially transposed density matrix, and thus this criterion may be useful in the analysis of general continuous two-party systems. Another separability criterion used by Duan et al. is shown to be generally weaker than that of Simon. We thus have a hierarchy of separability criterions, but all these criterions when combined with suitable squeezing become equivalent at the boundary of the P-representation condition and thus turned out to be sufficient to analyze the separability of two-party Gaussian systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Range-separated density-functional theory with the random-phase approximation: Detailed formalism and illustrative applications

Using Green's-function many-body theory, we present the details of a formally exact adiabatic-connection fluctuation-dissipation density-functional theory based on range separation, which was sketched in Toulouse et al.[Phys. Rev. Lett. 102, 096404 (2009)]. Range-separated density-functional theory approaches combining short-range density-functional approximations with long-range random-phase approximations (RPAs) are then obtained as well-identified approximations on the long-range Green's-function self-energy. Range-separated RPA-type schemes with or without long-range Hartree-Fock exchange response kernel are assessed on rare-gas and alkaline-earth-metal dimers and compared to range-separated second-order perturbation theory and range-separated coupled-cluster theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Deuteron-α scattering: Separable versus nonseparable Faddeev approach

Deuteron-induced reactions are widely used to probe nuclear structure and astrophysical information. Those (d,p) reactions may be viewed as three-body reactions and described with Faddeev techniques. Faddeev-AGS equations in momentum space have a long tradition of utilizing separable interactions in order to arrive at sets of coupled integral equations in one variable. However, it needs to be demonstrated that observables calculated based on separable interactions agree exactly with those based on nonseparable forces. Momentum space AGS equations are solved with separable and nonseparable forces as coupled integral equations. Deuteron-α scattering is calculated via momentum space AGS equations using the CD-Bonn neutron-proton force and a Woods-Saxon type neutron(proton)- 4 He force, for which the Pauli-forbidden S-wave bound state is projected out. Elastic as well as breakup observables are calculated and compared to results in which the interactions in the two-body sub-systems are represented by separable interactions derived in the Ernst-Shakin-Thaler (EST) framework. We find that the calculations based on the separable representation of the interactions and the original interactions give results that are in excellent agreement. Specifically, integrated cross sections and angular distributions for elastic scattering agree within ≈ 1 %, which is well below typical experimental errors. In addition, the fivefold differential cross sections corresponding to breakup of the deuteron agree extremely well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Axially deformed relativistic Hartree Bogoliubov theory with a separable pairing force

A separable form of pairing interaction in the {sup 1}S{sub 0} channel has been introduced and successfully applied in the description of both static and dynamic properties of superfluid nuclei. By adjusting the parameters to reproduce the pairing properties of the Gogny force in nuclear matter, this separable pairing force is successful in depicting the pairing properties of ground states and vibrational excitations of spherical nuclei on almost the same footing as the original Gogny force. In this article, we extend these investigations for relativistic Hartree-Bogoliubov theory in deformed nuclei with axial symmetry (RHBZ) using the same separable pairing interaction. To preserve translational invariance we construct one- and two-dimensional Talmi-Moshinsky brackets for the cylindrical harmonic oscillator basis. We show that the matrix elements of this force can then be expanded in a series of separable terms. The convergence of this expansion is investigated for various deformations. We observe a relatively fast convergence. This allows for a considerable reduction in computing time as compared to RHBZ calculations with the full Gogny force in the pairing channel. As an example we solve the RHBZ equations with this separable pairing force for the ground states of the chain of Sm isotopes. Good agreement with the experimental data as well as with other theoretical results is achieved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Li 6 in a three-body model with realistic Forces: Separable versus nonseparable approach

Background: Deuteron induced reactions are widely used to probe nuclear structure and astrophysical information. Those (d, p) reactions may be viewed as three-body reactions and described with Faddeev techniques. Purpose: Faddeev equations in momentum space have a long tradition of utilizing separable interactions in order to arrive at sets of coupled integral equations in one variable. However, it needs to be demonstrated that their solution based on separable interactions agrees exactly with solutions based on nonseparable forces. Methods: Momentum space Faddeev equations are solved with nonseparable and separable forces as coupled integral equations. Results: The ground state of 6 Li is calculated via momentum space Faddeev equations using the CD-Bonn neutron-proton force and a Woods-Saxon type neutron(proton)- 4 He force. For the latter the Pauli-forbidden S -wave bound state is projected out. This result is compared to a calculation in which the interactions in the two-body subsystems are represented by separable interactions derived in the Ernst-Shakin-Thaler (EST) framework. Conclusions: We find that calculations based on the separable representation of the interactions and the original interactions give results that agree to four significant figures for the binding energy, provided that energy and momentum support points of the EST expansion are chosen independently. The momentum distributions computed in both approaches also fully agree with each other.

6 ≤ A ≤ 19↗

Comparing Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Full and Tapered Bump Arrays

To separate particles from carrier fluids arrays of staggered posts inserted into the flow stream can be employed. The smaller particles follow the flow stream while the larger particles move laterally to one side. During flow, the concentration of particulate increases in one direction and decreases in the other crosswise direction. This technique separates the particles from the carrier fluid. Experiments using a slurry with non-Newtonian rheology were conducted to evaluate large particle separation from the non-Newtonian carrier fluid using bump arrays. The bentonite kaolin clay slurry with non-Newtonian rheology was spiked with large diameter inert glass particles. Experiments with flow through lateral displacement arrays evaluated the performance of particle separation using two array configurations: a full array with all posts and a tapered array with posts removed in a triangular portion of the array past the rows of anticipated particle of separation. The posts are staggered posts to promote particle segregation to one side of the flow channel. Using this type of array for removing particles from non-Newtonian yield stress slurries is novel and we present unique results. In this paper, the performance of full and tapered arrays are compared. These results have many industrial applications including removing particles from slurries of nuclear waste. Large particle removal is an important step in waste processing.

slurry, solids removal, deterministic lateral disp↗

Mesofluidic Oil-Water Separation

Separating flowing multiphase solutions in process at industrial scale is challenging. A rapid continuous approach is desired. These mesofluidic oil-water separation tests were motivated by reports by Dijkshoorn et al [1] who reported separating droplets and particles using displacement with regularly spaced channels using a cross-flow microsieve.. Droplets, including deformable particles, larger than the channel migrate in one direction and thereby deplete in the other direction. Test flowrates were motivated by Burns et al. [4] who showed that separation could occur under laminar conditions, and Pease et al [8, 9] who extended the range to turbulent flow. Testing was conducted using two two-component oil-water mixtures at room temperature. Analysis showed separation of both mineral oils from their oil water mixtures at flowrates from 1-2 L/min and concentrations from 2-10 wt% oil in water.

cloud height, effective cleaning radius, effective↗

WE-G-18C-07: Accelerated Water/fat Separation in MRI for Radiotherapy Planning Using Multi-Band Imaging Techniques

Purpose: Dixon sequences are used to characterize disease processes, obtain good fat or water separation in cases where fat suppression fails and to obtain pseudo-CT datasets. Dixon's method uses at least two images acquired with different echo times and thus requires prolonged acquisition times. To overcome associated problems (e.g., for DCE/cine-MRI), we propose to use a method for water/fat separation based on spectrally selective RF pulses. Methods: Two alternating RF pulses were used, that imposes a fat selective phase cycling over the phase encoding lines, which results in a spatial shift for fat in the reconstructed image, identical to that in CAIPIRINHA. Associated aliasing artefacts were resolved using the encoding power of a multi-element receiver array, analogous to SENSE. In vivo measurements were performed on a 1.5T clinical MR-scanner in a healthy volunteer's legs, using a four channel receiver coil. Gradient echo images were acquired with TE/TR = 2.3/4.7ms, flip angle 20°, FOV 45×22.5cm{sup 2}, matrix 480×216, slice thickness 5mm. Dixon images were acquired with TE,1/TE,2/TR=2.2/4.6/7ms. All image reconstructions were done in Matlab using the ReconFrame toolbox (Gyrotools, Zurich, CH). Results: RF pulse alternation yields a fat image offset from the water image. Hence the water and fat images fold over, which is resolved using in-plane SENSE reconstruction. Using the proposed technique, we achieved excellent water/fat separation comparable to Dixon images, while acquiring images at only one echo time. Conclusion: The proposed technique yields both inphase water and fat images at arbitrary echo times and requires only one measurement, thereby shortening the acquisition time by a factor 2. In future work the technique may be extended to a multi-band water/fat separation sequence that is able to achieve single point water/fat separation in multiple slices at once and hence yields higher speed-up factors.

60 APPLIED LIFE SCIENCES↗

SU-F-T-637: Single-Isocenter Versus Multiple-Isocenter VMAT SRS for Unusual Multiple Metastasis Case with Two Widely Separated Lesions

Purpose: Single-isocenter (SI) volumetric modulated arc therapy has been shown to be an effective and efficient approach to multiple metastasis radiosurgery. However, certain extreme cases raise the question of whether multiple-isocenter (MI) approaches can still generate superior plans. In this study, we ask this question with respect to a clinical case with two very widely separated lesions. Methods: A patient with two widely separated (d = 12cm) tumors was treated with SI-VMAT SRS using 10MV flattening filter free (FFF) beam with high-definition multi-leaf collimator (HD-MLC, 2.5/5mm) in two non-coplanar arcs using concentric rings to enforce steep gradient. Because of lesion positioning with respect to collimator angle selection, lesions were treated by 5mm leaves. We re-planned the case with a congruent arc arrangement but separate isocenter for each lesion. In this manner, lesions were treated by 2.5mm leaves. Conformity index (CI), V50%, and mean brain dose were compared. Results: Neither conformity (CI-SI = 1.12, CI-MI = 1.08) nor V50% (V50%-SI =8.82cc, V50%-MI =8.81cc) were improved by utilizing a separate isocenter for each lesion. Mean brain dose was slightly reduced (dmean-SI = 118.4 cGy, dmean-MI = 88.7 cGy) by using multiple isocenters. Conclusion: For this case with a lesion at the apex of the brain and another distantly located at the base of skull, employing a separate isocenter for each target did not meaningfully improve plan quality. Single-isocenter VMAT has been shown feasible and equivalent to multiple-isocenter VMAT for multiple metastasis cases in general. In this extreme case, single- and multiple- isocenter VMAT were also equivalent. If rotational setup errors are appropriately corrected, the increased delivery efficiency of the single-isocenter approach renders it preferable to the multiple isocenter approach. Dr’s Thomas, Popple, and Fiveash have all received honoraria from Varian Medical Systems for discussing their experiences with stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of Microporous Separator in Fe/V Redox Flow Battery

The newly developed Fe/V redox flow battery has demonstrated attractive cell performance. However, the deliverable energy density is relatively inferior due to the low cell voltage. To compensate this disadvantage and compete with other redox flow battery systems, cost reduction of the Fe/V system is necessary. This paper describes evaluation of hydrocarbon-based Daramic® microporous separators for use in the Fe/V system. The separator B having ion exchange capacity demonstrated excellent capacity retention capability. Separator B exhibited energy efficiency above 65% over a broad temperature range of 5-50oC and at current densities up to 80mA/cm2. Plus, separator B is very inexpensive and has exceptional mechanical properties. Therefore, this separator shows great potential to replace the expensive Nafion® membrane. This will drive down the capital cost and make the Fe/V system a promising low-cost energy storage technology.

Wei, Xiaoliang↗

Separating Cloud and Drizzle Signals in Radar Doppler Spectra Using a Parametric Time Domain Method

The ability to separate cloud and drizzle returns in active remote sensing observations is important for understanding the microphysics of clouds and precipitation. Yet, robust separations remain challenging in radar remote sensing. Prior methods for cloud and drizzle separation for radar observations use the properties of the Doppler spectra such as skewness. However, these methods have challenges when the drizzle becomes dominant in the observation volume. This paper presents a parametric time domain method (PTDM) that separates cloud and drizzle using the Doppler spectra measurements without assuming any prior properties of cloud and drizzle. The advantage of PTDM is that it can estimate the signal properties in the time domain and can obtain the cloud and drizzle estimates simultaneously. Based on our radar signal simulations, the uncertainty in estimated power and velocity from PTDM are within 2 dB and 0.02 m s -1 , respectively. We have also evaluated the PTDM algorithm using observations from the Atmospheric Radiation Measurement (ARM) Program W-band cloud radar in the Clouds, Aerosols, and Precipitation in the Marine Boundary Layer (CAP-MBL) campaign at the Azores in 2009–10. Two cases corresponding to light and moderate drizzling conditions are considered for the study. The statistics of the estimates obtained show that the PTDM method performs well in separating the cloud and drizzle returns. Finally, the estimated cloud and drizzle reflectivity from PTDM were used to retrieve their corresponding microphysical properties, showing that the retrieved liquid water path agrees to 25 g m -2 with the benchmark microwave method.

Engineering↗

Trace Elemental Analysis of Bulk Thorium Using an Automated Separation–Inductively Coupled Plasma Optical Emission Spectroscopy Methodology

Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. Finally, while reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.

47 OTHER INSTRUMENTATION↗