Search NASA⌕ Search

SEARCH · Search NASA

Results for “slicing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Neutron Characterization of Encapsulated ATF-1/LANL-1 Mockup Fuel Capsules

Twenty pellets of mock-up accident tolerant fuels UN-U3Si5 were produced at LANL and loaded in two rodlet/capsule assemblies. Tomographic imaging and diffraction measurements were performed to characterize these samples at the Flight-Path 5 and HIPPO beam lines at LANSCE/LANL between November 2016 and January 2017 as well as in August 2017. The entire ~10 cm long, ~1 cm diameter fuel volume could be characterized, however due to time constraints only 2 mm slices in 4mm increments were characterized with neutron diffraction and a 28mm subset of the entire sample was characterized with energy-resolved neutron imaging. The double encapsulation of the fuel into two steel containers does not pose a problem for the neutron analysis and the methods could be applied to enriched as well irradiated fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

JBP485 improves gentamicin-induced acute renal failure by regulating the expression and function of Oat1 and Oat3 in rats

We investigated the effects of JBP485 (an anti-inflammatory dipeptide and a substrate of OAT) on regulation of the expression and function of renal Oat1 and Oat3, which can accelerate the excretion of accumulated uremic toxins (e.g. indoxyl sulfate) in the kidney to improve gentamicin-induced ARF in rats. JBP485 caused a significant decrease in the accumulation of endogenous substances (creatinine, blood urea nitrogen and indoxyl sulfate) in vivo, an increase in the excretion of exogenous compounds (lisinopril and inulin) into urine, and up-regulation of the expressions of renal Oat1 and Oat3 in the kidney tissues and slices via substrate induction. To determine the effect of JBP485 on the accelerated excretion of uremic toxins mediated by Oat1 and Oat3, the mRNA and protein expression levels of renal basolateral Oats were assessed by quantitative real-time PCR, western blot, immunohistochemical analysis and an immunofluorescence method. Gentamicin down-regulated the expression of Oats mRNA and protein in rat kidney, and these effects were reversed after administration of JBP485. In addition, JBP485 caused a significant decrease in MPO and MDA levels in the kidney, and improved the pathological condition of rat kidney. These results indicated that JBP485 improved acute renal failure by increasing the expression and function of Oat1 and Oat3, and by decreasing overoxidation of the kidney in gentamicin-induced ARF rats. - Highlights: • JBP485 could up-regulate function and expression of Oat1 and Oat3 in kidney. • Effects of JBP485 on ARF are mediated by stimulating excretion of uremic toxins. • JBP485 protected against gentamicin-induced ARF by decreasing MPO and MDA.

60 APPLIED LIFE SCIENCES↗

Hoop conjecture in spherically symmetric spacetimes

We give general sufficient conditions for the existence of trapped surfaces due to concentration of matter in spherically symmetric initial data sets satisfying the dominant energy condition. These results are novel in that they apply and are meaningful for arbitrary spacelike slices, that is, they do not require any auxiliary assumptions such as maximality, time symmetry, or special extrinsic foliations, and most importantly they can easily be generalized to the nonspherical case once an existence theory for a modified version of the Jang equation is developed. Moreover, our methods also yield positivity and monotonicity properties of the Misner-Sharp energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-206-15: Effects of Dose Reduction On Emphysema Score

Purpose: The purpose of this study was to investigate the effects of reducing radiation dose levels on emphysema scores from lung cancer screening CT exams. Methods: 52 cases were selected from the National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data. All scans were acquired with fixed effective mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare) using 120kV, 64×0.6mm collimation and pitch 1.0. All images were reconstructed with 1mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions at 50% and 25% of the original dose (approximately 1.0- and 0.5-mGy CTDIvol). Lung segmentations were obtained via region growing from manual seed point at a threshold of 600HU followed by manual removal of trachea and major airways. Lung segmentations were only performed on original dose scans, and mapped to simulated reduced-dose scans. Emphysema scores based on relative area of lung with attenuation values lower than −950HU (RA950) were computed for all cases. Results: Average RA950 of all 50 cases were 31.6 (±5.5), 32.5 (±4.9) and 32.8 (±4.6) for 100%, 50% and 25% dose level respectively. The average absolute difference in RA950 between simulated and original dose scans were 1.0 (±0.7) and 1.4 (±1.1) for 50% and 25% dose level respectively. Conclusion: RA950 is relatively robust to dose level, with a difference of no more than 5 from the original dose scans. The average RA950 of this population was high for a two reasons: This was a high risk population of patients with substantial smoking history; The use of B50 kernel, which may be biased towards high emphysema scores. Further exploration with smoother kernels will be conducted in the future. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH grant support from U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study

Purpose: To determine the cut-off standardized uptake value (SUV) on {sup 18}F fluoro-2-deoxy-glucose (FDG) positron emission tomography/computed tomography (FDG-PET/CT) images that generates the best volumetric match to pathologic gross tumor volume (GTV{sub path}) for non-small-cell lung cancer (NSCLC). Methods and Materials: Fifteen patients with NSCLC who underwent FDG-PET/CT scans followed by lobectomy were enrolled. The surgical specimen was dissected into 5-7-mum sections at approximately 4-mm intervals and stained with hematoxylin and eosin. The tumor-containing area was outlined slice by slice and the GTV{sub path} determined by summing over all the slices, taking into account the interslice thickness and fixation-induced volume reduction. The gross tumor volume from the PET images, GTV{sub PET}, was determined as a function of cut-off SUV. The optimal threshold or optimal absolute SUV was defined as the value at which the GTV{sub PET} was the same as the GTV{sub path}. Results: The fixation process induced a volumetric reduction to 82% +- 10% (range, 62-100%) of the original. The maximal SUV was 10.1 +- 3.6 (range, 4.2-18.7). The optimal threshold and absolute SUV were 31% +- 11% and 3.0 +- 1.6, respectively. The optimal threshold was inversely correlated with GTV{sub path} and tumor diameter (p < 0.05), but the optimal absolute SUV had no significant correlation with GTV{sub path} or tumor diameter (p > 0.05). Conclusion: This study evaluated the use of GTV{sub path} as a criterion for determining the optimal cut-off SUV for NSCLC target volume delineation. Confirmatory studies including more cases are being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of cell-based diffusion acceleration for the slice balance approach

In this work, we perform analysis on the use of cell-based diffusion acceleration methodologies to accelerate the convergence of transport solutions discretized with the slice balance approach (SBA) on unstructured polygonal grids.We investigated both linear diffusion synthetic acceleration (DSA) and non linear diffusion acceleration (NDA), including its partial-current variant (pNDA). DSA and NDA were both shown to diverge for intermediate ranges of mesh optical thicknesses. However, pNDA and Krylov methods like GMRES and Broyden stabilized the acceleration schemes, including problems with degenerate cells formed by mesh refinement. (author)

42 ENGINEERING↗

A Shift Selection Strategy for Parallel Shift-Invert Spectrum Slicing in Symmetric Self-Consistent Eigenvalue Computation

The central importance of large scale eigenvalue problems in scientific computation necessitates the development massively parallel algorithms for their solution. Recent advances in dense numerical linear algebra have enabled the routine treatment of eigenvalue problems with dimensions on the order of hundreds of thousands on the world's largest supercomputers. In cases where dense treatments are not feasible, Krylov subspace methods offer an attractive alternative due to the fact that they do not require storage of the problem matrices. However, demonstration of scalability of either of these classes of eigenvalue algorithms on computing architectures capable of expressing excessive parallelism is non-trivial due to communication requirements and serial bottlenecks, respectively. In this work, we introduce the SISLICE method: a parallel shift-invert algorithm for the solution of the symmetric self-consistent field (SCF) eigenvalue problem. The SISLICE method drastically reduces the communication requirement of current parallel shift-invert eigenvalue algorithms through various shift selection and migration techniques based on density of states estimation and k-means clustering, respectively. This work demonstrates the robustness and parallel performance of the SISLICE method on a representative set of SCF eigenvalue problems and outlines research directions which will be explored in future work.

97 MATHEMATICS AND COMPUTING↗

Ureter tracking and segmentation in CT urography (CTU) using COMPASS

Purpose: The authors are developing a computerized system for automated segmentation of ureters in CTU, referred to as combined model-guided path-finding analysis and segmentation system (COMPASS). Ureter segmentation is a critical component for computer-aided diagnosis of ureter cancer. Methods: COMPASS consists of three stages: (1) rule-based adaptive thresholding and region growing, (2) path-finding and propagation, and (3) edge profile extraction and feature analysis. With institutional review board approval, 79 CTU scans performed with intravenous (IV) contrast material enhancement were collected retrospectively from 79 patient files. One hundred twenty-four ureters were selected from the 79 CTU volumes. On average, the ureters spanned 283 computed tomography slices (range: 116–399, median: 301). More than half of the ureters contained malignant or benign lesions and some had ureter wall thickening due to malignancy. A starting point for each of the 124 ureters was identified manually to initialize the tracking by COMPASS. In addition, the centerline of each ureter was manually marked and used as reference standard for evaluation of tracking performance. The performance of COMPASS was quantitatively assessed by estimating the percentage of the length that was successfully tracked and segmented for each ureter and by estimating the average distance and the average maximum distance between the computer and the manually tracked centerlines. Results: Of the 124 ureters, 120 (97%) were segmented completely (100%), 121 (98%) were segmented through at least 70%, and 123 (99%) were segmented through at least 50% of its length. In comparison, using our previous method, 85 (69%) ureters were segmented completely (100%), 100 (81%) were segmented through at least 70%, and 107 (86%) were segmented at least 50% of its length. With COMPASS, the average distance between the computer and the manually generated centerlines is 0.54 mm, and the average maximum distance is 2.02 mm. With our previous method, the average distance between the centerlines was 0.80 mm, and the average maximum distance was 3.38 mm. The improvements in the ureteral tracking length and both distance measures were statistically significant (p < 0.0001). Conclusions: COMPASS improved significantly the ureter tracking, including regions across ureter lesions, wall thickening, and the narrowing of the lumen.

60 APPLIED LIFE SCIENCES↗

SU-D-207A-06: Pediatric Abdominal Organ Motion Quantified Via a Novel 4D MRI Method

Purpose: To develop a 4D MRI method for assessing respiration-induced abdominal organ motion in children receiving radiation therapy. Methods: A 4D MRI using internal image-based respiratory surrogate has been developed and implemented on a clinical scanner (1.5T Siemens Avanto). Ten patients (younger group: N=6, 2–5 years, anesthetized; older group: N=4, 11–15 years) with neuroblastoma, Wilm’s tumor rhabdomyosarcoma, or desmoplastic small round cell tumor received free breathing 4D MRI scans for treatment planning. Coronal image slices of the entire abdomen were retrospectively constructed in 10 respiratory phases. A B-spline deformable registration (Metz et al. 2011) was performed on 4D datasets to automatically derive motion trajectories of selected anatomical landmarks, including the dome and the center of the liver, and the superior edges of kidneys and spleen. The extents of the motion in three dimensions (anteroposterior, AP; mediolateral, ML; superoinferior, SI) and the correlations between organ motion trajectories were quantified. Results: The 4D MRI scans were successfully performed in <20 minutes for all patients without the use of any external device. Organ motion extents were larger in adolescents (kidneys: 3–13 mm SI, liver and spleen: 6–18 mm SI) than in younger children (kidneys:<3mm in all directions; liver and spleen: 1–8 mm SI, 1–5 mm ML and AP). The magnitude of respiratory motion in some adolescents may warrant special motion management. Motion trajectories were not synchronized across selected anatomical landmarks, particularly in the ML and AP directions, indicating inter- and intra-organ variations of the respiratory-induced motion. Conclusion: The developed 4D MRI acquisition and motion analysis methods provide a non-ionizing, non-invasive approach to automatically measure the organ motion trajectory in the pediatric abdomen. It is useful for defining ITV and PRV, monitoring changes in target motion patterns during the treatment course, and studying interplay effects in proton scanning.

60 APPLIED LIFE SCIENCES↗

A global ensemble of ocean wave climate projections from CMIP5-driven models

This dataset, produced through the Coordinated Ocean Wave Climate Project (COWCLIP) phase 2, represents the first coordinated multivariate ensemble of 21st Century global wind-wave climate projections available (henceforth COWCLIP2.0). COWCLIP2.0 comprises general and extreme statistics of significant wave height (H S ), mean wave period (T m ), and mean wave direction (θ m ) computed over time-slices 1979–2004 and 2081–2100, at different frequency resolutions (monthly, seasonally and annually). The full ensemble comprising 155 global wave climate simulations is obtained from ten CMIP5-based state-of-the-art wave climate studies and provides data derived from alternative wind-wave downscaling methods, and different climate-model forcing and future emissions scenarios. The data has been produced, and processed, under a specific framework for consistency and quality, and follows CMIP5 Data Reference Syntax, Directory structures, and Metadata requirements. Technical comparison of model skill against 26 years of global satellite measurements of significant wave height has been undertaken at global and regional scales. This new dataset provides support for future broad scale coastal hazard and vulnerability assessments and climate adaptation studies in many offshore and coastal engineering applications.

Science & Technology - Other Topics↗

MULTI-SCALE MORPHOLOGICAL ANALYSIS OF SDSS DR5 SURVEY USING THE METRIC SPACE TECHNIQUE

Following the novel development and adaptation of the Metric Space Technique (MST), a multi-scale morphological analysis of the Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) was performed. The technique was adapted to perform a space-scale morphological analysis by filtering the galaxy point distributions with a smoothing Gaussian function, thus giving quantitative structural information on all size scales between 5 and 250 Mpc. The analysis was performed on a dozen slices of a volume of space containing many newly measured galaxies from the SDSS DR5 survey. Using the MST, observational data were compared to galaxy samples taken from N-body simulations with current best estimates of cosmological parameters and from random catalogs. By using the maximal ranking method among MST output functions, we also develop a way to quantify the overall similarity of the observed samples with the simulated samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Strong Evidence for Nucleon Resonances near 1900 MeV

Data on the reaction yp→K + A from the CLAS experiments are used to derive the leading multipoles, E 0+ , M 1- , E 1+ , and M 1+ , from the production threshold to 2180 MeV in 24 slices of the invariant mass. The four multipoles are determined without any constraints. The multipoles are fitted using a multichannel L+P model that allows us to search for singularities and to extract the positions of poles on the complex energy plane in an almost model-independent method. The multipoles are also used as additional constraints in an energy-dependent analysis of a large body of pion and photoinduced reactions within the Bonn-Gatchina partial wave analysis. The study confirms the existence of poles due to nucleon resonances with spin parity J P =1/2 - , 1/2 + , and 3/2 + in the region at about 1.9 GeV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035-2.71 Gy) and 0.34 Gy (range, 0.066-3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03-0.159 Gy) and 0.05 Gy (range, 0.015-0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056-1.97 Gy) and 0.306 Gy (range, 0.065-2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

60 APPLIED LIFE SCIENCES↗

SU-E-J-38: Improved DRR Image Quality Using Polyetheretherketone (PEEK) Fiducial in Image Guided Radiotherapy (IGRT)

Purpose Fiducial-based imaging is often used in IGRT. Traditional gold fiducial marker often has substantial reconstruction artifacts. These artifacts Result in poor image quality of DRR for online kV-to-DRR matching. This study evaluated the image quality of PEEK in DRR in static and moving phantom. Methods CT scan of the Gold and PEEK fiducial (both 1×3 mm) was acquired in a 22 cm cylindrical phantom filled with water. Image artifacts was evaluated with maximum CT value deviated from water due to artifacts; volume of artifacts in 10×10 cm in the center slice; maximum length of streak artifacts from the fiducial. DRR resolution were measured using FWHM and FWTM. 4DCT of PEEK fiducial was acquired with the phantom moving sinusoidally in superior-inferior direction. Motion artifacts were assessed for various 4D phase angles. Results The maximum CT value deviation was −174 for Gold and −24 for PEEK. The volume of artifacts in a 10x10 cm 3 mm slice was 0.369 for Gold and 0.074 cm3 for PEEK. The maximum length of streak artifact was 80mm for Gold and 7 mm for PEEK. PEEK in DRR, FWHM was close to actual (1.0 mm for Gold and 1.1 mm for PEEK). FWTM was 1.8 mm for Gold and 1.3 mm for PEEK in DRR. Barrel motion artifact of PEEK fiducial was noticeable for free-breathing scan. The apparent PEEK length due to residual motion was in close agreement with the calculated length (13 mm for 30–70 phase, 10 mm in 40–60 phase). Conclusion Streak artifacts on planning CT associated with use of gold fiducial can be significantly reduced by PEEK fiducial, while having adequate kV image contrast. DRR image resolution at FWTM was improved from 1.8 mm to 1.3 mm. Because of this improvement, we have been routinely use PEEK for liver IGRT.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-05: Evaluation of a Novel Algorithm for Improved 4DCT Resolution

Purpose: Accurate tumor motion characterization is critical for increasing the therapeutic ratio of radiation therapy. To accommodate the divergent fan-beam geometry of the scanner, the current 4D-CT algorithm utilizes a larger temporal window to ensure that pixel values are valid throughout the entire FOV. To minimize the impact on temporal resolution, a cos{sup 2} weighting is employed. We propose a novel exponential weighting (“exponential”) 4DCT reconstruction algorithm that has a sharper slope and provides a more optimal temporal resolution. Methods: A respiratory motion platform translated a lung-mimicking Styrofoam slab with several high and low-contrast inserts 2 cm in the superior-inferior direction. Breathing rates (10–15 bpm) and couch pitch (0.06–0.1 A.U.) were varied to assess interplay between parameters. Multi-slice helical 4DCTs were acquired with 0.5 sec gantry rotation and data were reconstructed with cos{sup 2} and exponential weighting. Mean and standard deviation were calculated via region of interest analysis. Intensity profiles evaluated object boundaries. Retrospective raw data reconstructions were performed for both 4DCT algorithms for 3 liver and lung cancer patients. Image quality (temporal blurring/sharpness) and subtraction images were compared between reconstructions. Results: In the phantom, profile analysis revealed that sharper boundaries were obtained with exponential reconstructions at transitioning breathing phases (i.e. mid-inhale or mid-exhale). Reductions in full-width half maximum were ∼1 mm in the superior-inferior direction and appreciable sharpness could be observed in difference maps. This reduction also yielded a slight reduction in target volume between reconstruction algorithms. For patient cases, coronal views showed less blurring at object boundaries and local intensity differences near the tumor and diaphragm with exponential weighted reconstruction. Conclusion: Exponential weighted 4DCT offers potential for improving image sharpness in 4DCT. Comparisons with true object extent using static CTs of varied phantom positions are necessary to confirm these findings. Future work with additional patient cases is warranted. Research partially sponsored by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-R-25: Automatic Identification of Suspicious Recurrent/residual Disease Regions After Prostatectomy

Purpose: To automatically identify and outline suspicious regions of recurrent or residual disease in the prostate bed using Dynamic Contrast Enhanced-MRI (DCE-MRI) in patients after prostatectomy. Methods: Twenty-two patients presenting for salvage radiotherapy and with identified Gross Tumor Volume (GTV) in the prostate bed were retrospectively analyzed. The MRI data consisted of Axial T2weighted-MRI (T2w) of the pelvis: resolution 1.25×1.25×2.5 mm; Field of View (FOV): 320×320 mm; slice thickness=2.5mm; 72 slices; and Dynamic Contrast Enhanced MRI (DCE-MRI)–12 series of T1w with identical spatial resolution to T2w and at 30–34s temporal resolution. Unsupervised pattern recognition was used to decompose the 4D DCE data as the product W.H of weights W of k patterns H. A well-perfused pattern Hwp was identified and the weight map Wwp associated to Hwp was used to delineate suspicious volumes. Threshold of Wwp set at mean(Wwp)+S*std(Wwp), S=1,1.5,2 and 2.5 defined four volumes labeled as DCE1.0 to DCE2.5. These volumes were displayed on T2w and, along with GTV, were correlated with the highest pre-treatment PSA values, and with pharmacokinetic analysis constants. Results: GTV was significantly correlated with DCE2.0(ρ= 0.60, p<0.003), and DCE 2.5 (ρ=0.58, p=0.004)). Significant correlation was found between highest pre-treatment PSA and GTV(ρ=0.42, p<0.049), DCE2.0(ρ= 0.52, p<0.012), and DCE 2.5 (ρ=0.67, p<<0.01)). Kruskal-Wallis analysis showed that Ktrans median value was statistically different between non-specific prostate bed tissue NSPBT and both GTV (p<<0.001) and DCE2.5 (p<<0.001), but while median Ve was statistically different between DCE2.5 and NSPBT (p=0.002), it was not statistically different between GTV and NSPBT (p=0.054), suggesting that automatic volumes capture more accurately the area of malignancy. Conclusion: Software developed for identification and visualization of suspicions regions in DCE-MRI from post-prostatectomy patients has been validated by PSA and pharmacokinetic constants analysis showing that it generates clinically relevant volumes.

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze the images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).

60 APPLIED LIFE SCIENCES↗