Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A Perspective on Quantum Computing Applications in Quantum Chemistry Using 25-100 Logical Qubits

The intersection of quantum computing and quantum chemistry represents a promising frontier for achieving quantum utility in domains of both scientific and societal relevance. Owing to the exponential growth of classical resource requirements for simulating quantum systems, quantum chemistry has long been recognized as a natural candidate for quantum computation. This perspective focuses on identifying scientifically meaningful use cases where early fault-tolerant quantum computers, which are considered to be equipped with approximately 25-100 logical qubits, could deliver tangible impact. While recent advances in classical computing have pushed the boundaries of tractable simulations to unprecedented scales, this logical-qubit regime represents the first window where quantum devices can pursue qualitatively distinct strategies, such as polynomial-scaling phase estimation, direct simulation of quantum dynamics, and active-space embedding, that remain challenging for classical solvers, such as multireference charge-transfer and conical-intersection states central to photochemistry and materials design. We highlight near-term opportunities in algorithm and software design, discuss representative chemical problems suited for quantum acceleration, and propose strategic roadmaps and collaborative pathways for advancing practical quantum utility in quantum chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities. (2016-06-06)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tokamak-independent Software Analysis Suite for Multi-Spectral Line-Polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (MSE) diagnostics. The software supports multi-spectral line-polarization MSE diagnostics which simultaneously measure emission at the MSE sigma and pi lines as well as at two `background' wavelengths that are displaced from the MSE spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially-polarized background light at the sigma and pi wavelengths even in situations where the background light changes rapidly in time and space. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the MSE photo-elastic modulators (PEMs) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to PEM retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the MSE diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge The software suite is modular, parallelized, and portable to other facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PySIDT: Subgraph Isomorphic Decision Trees for Molecular Property Prediction

Accurate molecular property prediction is important across all fields of chemistry. Deep neural networks (DNNs) have become increasingly popular due to their ability to train automatically, avoiding the incredibly tedious process of constructing and extending traditional property estimation schemes. However, DNNs require large amounts of training data, are challenging to interpret, require large amounts of memory to load even during inference, and have severe difficulties incorporating qualitative chemical knowledge, which are often desired for molecular property prediction tasks. Here, in this study, we present PySIDT (https://github.com/zadorlab/PySIDT), a software for training and running inference on Subgraph Isomorphic Decision Trees (SIDTs). SIDTs are graph-based decision trees made of nodes associated with molecular substructures. Inference is done by descending target molecular structures down the decision tree to nodes with matching subgraph isomorphic substructures and making predictions based on the final (most specific) nodes matched. SIDTs scale down well to dataset sizes much smaller than is feasible for DNNs. As trees of molecular substructures, SIDTs are inherently readable and easy to visualize, making them easy to analyze. They are also straightforward to extend and retrain, facilitate uncertainty estimation, and enable easy integration of expert knowledge. We demonstrate the SIDT approach discussing its application to a diverse range of molecular prediction tasks: rate coefficient estimation, diffusion coefficient estimation, thermochemistry estimation, transition state bond stretch prediction, p K a prediction, stability of molecular structures, stability of surface structures, and prediction of surface lateral interaction energetics. Additionally, we demonstrate the power of the SIDT algorithms in two direct learning curve vanilla comparisons with the popular DNN-based software Chemprop and the popular gradient boosted trees-based software XGBoost on enthalpy of formation and rate coefficient prediction tasks. In particular, in the enthalpy of formation case, vanilla PySIDT is able to outperform vanilla Chemprop and XGBoost across the full range of training/validation set sizes out to 11,560 data points.

Johnson, Matthew Sean [Sandia National Laboratorie↗

AI-Science for Performance Optimization and Diagnosis of Science Instrument Federations

Next generation of science workflows are expected to be executed over complex federations composed of supercomputers, science instruments, storage systems and networks, with new additions of the edge and cloud systems and services. The sheer complexity of these multi-domain federations makes it hard to manage them and optimize their performance, as small impedance mismatches (that can dynamically develop between systems) could drastically degrade the entire federation performance. Recent proliferation of Software Defined Everything (SDX) technologies combined with containerization frameworks provide custom instruments that can monitor and collect critical measurements at various levels to support diagnoses and performance optimization; but their data too enormous for human operators and analysts to process and generate decisions. Machine Learning (ML) methods that extract critical parameters, relationships and trends from the data offer general solutions. Artificial Intelligence (AI) and ML methods must be custom-developed for these problems based on solid, rigorous foundations, since black-box approaches are often ineffective and unsound.We propose to develop comprehensive AI-Science for the performance of science federations to (i) monitor and control storage, networks, experiments, and computing systems across multiple domains via softwarization layers, at speeds and scales orders of magnitude superior to current practice, (ii) optimally realize and orchestrate complex workflows with high performance by using dynamic state and performance estimation methods, and (iii) aggregate measurements across sites and time to develop infrastructure-level profiles, optimizations and diagnoses using AI-Science based on foundational principles from ML, game theory, and information fusion areas.

Rao, Nageswara↗

Design Process for the Development of a New Truck Monitoring System - 13306

Canberra Industries, Inc. has designed a new truck monitoring system for a facility in Japan. The customer desires to separately quantify the Cs-137 and Cs-134 content of truck cargo entering and leaving a Waste Consolidation Area. The content of the trucks will be some combination of sand, soil, and vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. The typical weight of the trucks will be approximately 10 tons, but can vary between 4 and 20 tons. The system must be sensitive enough to detect 100 Bq/kg in 10 seconds (with less than 10% relative standard deviation) but still have enough dynamic range to measure 1,000,000 Bq/kg material. The system will be operated in an outdoor environment. Starting from these requirements, Canberra explored all aspects of the counting system in order to provide the customer with the optimized solution. The desire to separately quantify Cs-137 and Cs-134 favors the use of a spectroscopic system as a solution. Using the In Situ Object Counting System (ISOCS) mathematical efficiency calculation tool, we explored various detector types, number, and physical arrangement for maximum performance. Given the choice of detector, the ISOCS software was used to investigate which geometric parameters (fill height, material density, etc.) caused the most fluctuations in the efficiency results. Furthermore, these variations were used to obtain quantitative estimates of the uncertainties associated with the possible physical variations in the truck size, detector positioning, and material composition, density, and fill height. Various shielding options were also explored to ensure that any measured Cs content would be from the truck and not from the surrounding area. The details of the various calculations along with the final design are given. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Advances for Sustainable Remediation: In Situ Monitoring and Climate Resiliency - 18436

Recent advances in sustainable remediation techniques show promise as solutions for contaminant removal in soil and groundwater media. Although passive remediation (or natural attenuation) has gained momentum as an acceptable technique, there are still challenges in regulatory frameworks as well as in public acceptance. Leaving contaminants in subsurface requires increased burden of proof to show that plumes are stable and residual contaminants do not pose a significant health risk. Climate changes and frequent extreme climate events contribute another level of complexity and make it difficult to demonstrate system stability and predict future plume conditions. In this study, we show two coupled approaches to tackle this challenge: (1) in situ groundwater monitoring based on advanced sensor and data analytics technologies (i.e., Big Data), and (2) state-of-art modeling for optimizing monitoring and site closure strategies. In the new monitoring approach, in situ sensors are used to continuously measure the key variables that control contaminant plume mobility and its spatial and temporal distribution (such as pH, redox potential, electrical conductivity, and groundwater level). Coupled with a limited number of groundwater sampling, the data analytics methods - data mining and machine learning - allow us to estimate contaminant concentrations, and also to detect any significant changes associated with the plume mobility. In parallel, the state-of-art numerical flow and reactive transport model - ASCEM software under DOE Office of Environmental Management - provides a physical and mechanistic understanding of the system behavior, and predicts the long-term plume migration for optimizing the monitoring and closure strategies. In particular, we focus on the effects of extreme precipitation or drought on the site closure as well as monitoring strategies. We demonstrate this approach at the Savannah River Site (SRS) F-Area, where groundwater is contaminated by various radionuclides, including uranium, tritium and technetium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculating Dose Release Factors to Obtain the Worst-Case Maximally Exposed Location by Sector

The aim of this project was to update the SRS Dose Release Factors (DRF's) for the Maximally Exposed Individual (MEI) for 20 area release points onsite. To update, potential MEIs now include onsite locations and modeled stack heights were updated to match onsite operations. The DRF's and MEI locations are used to ensure DOE and EPA compliance is met for dose standards. The Environmental Protection Agency (EPA) requires the use of the computer model CAP88 to estimate doses for demonstrating compliance with 40 CFR 61, the National Emission Standard for Hazardous Air Pollutants (NESHAP). The location of the maximally exposed individual (MEI) by sector and distance is required for execution of CAP88. The worst-case sector is the sector and distance where an offsite individual would receive the highest dose due to a potential release from a designated release location at a facility. The worst-case sector analysis addresses potential ground-level and stack-height releases from 20 areas of Savannah River Site (SRS). Weather patterns were analyzed at each of these areas relative to sixteen compass points. The analysis makes use of recently updated distance data and meteorological data. The computer model, CAP88 is EPA's software system used by the Department of Energy (DOE) to calculate the receptor dose due to routine atmospheric releases via a gaussian plume at the Savannah River Site (SRS). The dose-release factors (DRFs) are used to estimate the offsite and onsite dose from facility-specific releases and represent the dose to a receptor exposed to 1 Ci of a specified radionuclide being released into the atmosphere. The DRFs are simply a ratio of the TED to the release rate and, therefore, are directly scalable. The DRF values listed in the Appendix can be applied to expected release values from each area to estimate the potential dose to an individual adult at each location. NESHAP DRFs have been supplied to Environmental Compliance and Area Closure Projects (EC and ACP) for many years and are periodically updated to include changes in Cap88. estimate the potential dose to an individual adult at each location DRF in mrem Ci{sup -1} are estimated by modeling the total effective dose (TED) in mrem yr{sup -1} assuming an annual atmospheric release rate of 1 Ci yr-1 of the associated radionuclides. TED = Effective Dose (ED) + Committed Effective Dose (CED). TED = DRF/RR. Approach and Methods: Determine possible MEI locations Onsite/Offsite including buildings and farms; Determine the distances from the release area to the possible MEI location and the direction from the release to the MEI location; Using the most recent meteorological data (2007-2011) and parameters, run CAP88 for each release area for each compass sector and previously calculated distances to MEI locations using a 1 Ci release rate for tritium; Use the calculated the air concentration values to determine the MEI for each sector from CAP88. The relationship between air concentration and received dose is directly proportional and can be used to determine which locations to calculate DRF's and a dose for an MEI; The DRFs are found for each compass sector from 20 SRS release areas using CAP88-PC Version 4.0; Each location is calculated with ground level releases evaluated for each area for a list of radionuclides, some with and some without progenies; Compare the DRFs of the potential onsite MEIs to offsite MEIs. Based on the 2018 MEI Report, the Site worst case sector MEI is located 593 mW of B-Area. This MEI location represents a point along the main road that travels through a tract of land leased to the SC National Guard. While this location is estimated to have the highest exposure, minimal radioactivity is released from B-Area. In 2017, SRS requested and was approved by the EPA to change the location for modeling site releases from the Center of Site to H-Area, and to use six stack heights. H-Area emission account for approximately 90% of all radioactive operations onsite. The MEI for H-Area was found to be 11,458 m NNE which locates the Savannah River Ecology Lab Conference Center. Comparisons for 2018 data and 2014 shows the new methods of calculation are more conservative yet still remain well below the DOE 100 mrem limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regional heritability advanced complex trait analysis for GPU and traditional parallel architectures

Motivation: Quantification of the contribution of genetic variation to phenotypic variation for complex traits becomes increasingly computationally demanding with increasing numbers of single-nucleotide polymorphisms and individuals. To meet the challenges in making feasible large-scale studies, we present the REgional heritability advanced complex trait analysis software. Adapted from advanced complex trait analysis (and, in turn, genome-wide complex trait analysis), it is tailored to exploit the parallelism present in modern traditional and graphics processing unit (GPU)-accelerated machines, from workstations to supercomputers. Results: We adapt the genetic relationship matrix estimation algorithm to remove limitations on memory, allowing the analysis of large datasets. Further, we build on this to develop a version of the code able to efficiently exploit GPU-accelerated systems for both the genetic relationship matrix and REstricted maximum likelihood (REML) parts of the analysis, offering substantial speedup over the traditional central processing unit version. We develop the ability to analyze multiple small regions of the genome across multiple compute nodes in parallel, following the ‘regional heritability’ approach. We demonstrate the new software using 1024 GPUs in parallel on one of the world’s fastest supercomputers. Availability: The code is freely available at http://www.epcc.ed.ac.uk/software-products

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-J-92: Validating Dose Uncertainty Estimates Produced by AUTODIRECT, An Automated Program to Evaluate Deformable Image Registration Accuracy

Purpose: Deformable image registration (DIR) is a powerful tool with the potential to deformably map dose from one computed-tomography (CT) image to another. Errors in the DIR, however, will produce errors in the transferred dose distribution. We have proposed a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), which predicts voxel-specific dose mapping errors on a patient-by-patient basis. This work validates the effectiveness of AUTODIRECT to predict dose mapping errors with virtual and physical phantom datasets. Methods: AUTODIRECT requires 4 inputs: moving and fixed CT images and two noise scans of a water phantom (for noise characterization). Then, AUTODIRECT uses algorithms to generate test deformations and applies them to the moving and fixed images (along with processing) to digitally create sets of test images, with known ground-truth deformations that are similar to the actual one. The clinical DIR algorithm is then applied to these test image sets (currently 4) . From these tests, AUTODIRECT generates spatial and dose uncertainty estimates for each image voxel based on a Student’s t distribution. This work compares these uncertainty estimates to the actual errors made by the Velocity Deformable Multi Pass algorithm on 11 virtual and 1 physical phantom datasets. Results: For 11 of the 12 tests, the predicted dose error distributions from AUTODIRECT are well matched to the actual error distributions within 1–6% for 10 virtual phantoms, and 9% for the physical phantom. For one of the cases though, the predictions underestimated the errors in the tail of the distribution. Conclusion: Overall, the AUTODIRECT algorithm performed well on the 12 phantom cases for Velocity and was shown to generate accurate estimates of dose warping uncertainty. AUTODIRECT is able to automatically generate patient-, organ- , and voxel-specific DIR uncertainty estimates. This ability would be useful for patient-specific DIR quality assurance.

60 APPLIED LIFE SCIENCES↗

Engineering a modular 44 Ti/ 44 Sc generator: eluate evaluation in preclinical models and estimation of human radiation dosimetry

Background: 44 Sc/ 47 Sc is an attractive theranostic pair for targeted in vivo positron emission tomographic (PET) imaging and beta-particle treatment of cancer. The 44 Ti/ 44 Sc generator allows daily onsite production of this diagnostic isotope, which may provide an attractive alternative for PET facilities that lack in-house irradiation capabilities. Early animal and patient studies have demonstrated the utility of 44 Sc. In our current study, we built and evaluated a novel clinical-scale 44 Ti/ 44 Sc generator, explored the pharmacokinetic profiles of 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA (1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid) in naïve mice, and estimated the radiation burden of 44 ScCl 3 in humans. Methods: 44 Ti/ 44 Sc (101.2 MBq) in 6 M HCl solution was utilized to assemble a modular ZR resin containing generator. After assembly, 44 Sc was eluted with 0.05 M HCl for further PET imaging and biodistribution studies in female Swiss Webster mice. Based on the biodistribution data, absorbed doses of 44 / 47 ScCl 3 in human adults were calculated for 18 organs and tissues using the IDAC-Dose software. Results: 44 Ti in 6 M HCl was loaded onto the organic resin generator with a yield of 99.97%. After loading and initial stabilization, 44 ScCl 3 was eluted with 0.05 M HCl in typical yields of 82.9 ± 5.3% (N = 16), which was normalized to the estimated generator capacity. Estimated generator capacity was computed based on elution time interval and the total amount of 44 Ti loaded on the generator. Run in forward and reverse directions, the 44 Sc/ 44 Ti ratio from a primary column was significantly improved from 1038 ± 440 to 3557 ± 680 (Bq/Bq) when a secondary, replaceable, ZR resin cartridge was employed at the flow outlet. In vivo imaging and ex vivo distribution studies of the reversible modular generator for 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA show that free 44 Sc remained in the circulation significantly longer than the chelated 44 Sc. The dose estimation of 44 ScCl 3 reveals that the radiation burden is 0.146 mSv/MBq for a 70 kg adult male and 0.179 mSv/MBq for a 57 kg adult female. Liver, spleen and heart wall will receive the highest absorbed dose: 0.524, 0.502, and 0.303 mGy/MBq, respectively, for the adult male. Conclusions: A clinical-scale 44 Ti/ 44 Sc generator system with a modular design was developed to supply 44 ScCl 3 in 0.05 M HCl, which is suitable for further radiolabeling and in vivo use. Our data demonstrated that free 44 ScCl 3 remained in the circulation for extended periods, which resulted in approximately 10 times greater radiation burden than stably chelated 44 Sc. Stable 44 Sc/ 47 Sc-complexation will be more favorable for in vivo use and for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-201-06: Utility of Quantitative 3D SPECT/CT Imaging in Patient Specific Internal Dosimetry of 153-Samarium with GATE Monte Carlo Package

Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-T scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.

60 APPLIED LIFE SCIENCES↗

Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update

Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue composition for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite accurate under a variety of conditions. Our GPU-based fast MCS implementation took approximately 3 s to generate each angular projection for a 6 cm thick breast, which is believed to make this process acceptable for clinical applications. In addition, the clinical preferences of three radiologists were evaluated; the preference for the proposed method compared to the preference for the convolution-based method was statistically meaningful (p < 0.05, McNemar test). Conclusions: The proposed fully iterative scatter correction method and the GPU-based fast MCS using tissue-composition ratio estimation successfully improved the image quality within a reasonable computational time, which may potentially increase the clinical utility of DBT.

60 APPLIED LIFE SCIENCES↗

TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying System Level Impact of Connected and Automated Vehicles in an Urban Corridor

Numerous studies have demonstrated significant energy reduction for an ego vehicle by up to 20% leveraging Vehicle-to-Everything (V2X) technologies [1-4]. Some studies have also analyzed the impact of such vehicles on the energy consumption of other vehicles in a suburban or a highway corridor [5, 6], but the impact in an urban setting has not been studied yet. Southwest Research Institute (SwRI), in collaboration with Continental and Hyundai, is currently working on a Department of Energy funded project that is focused on quantifying the impact of multiple ego vehicles (smart vehicles) on the total energy consumption of the corridor under various traffic conditions, vehicle electrification level, vehicle-to-vehicle (V2V) technology penetration, and the number of smart (ego) vehicles in an urban setting. A six-kilometer-long urban corridor from Columbus, Ohio was modeled and calibrated with real-world data in PTV Vissim traffic microsimulation software. Five forward-looking powertrain models, consisting of two battery electric vehicles (BEVs), a hybrid electric vehicle (HEV), and two internal combustion engine (ICE) powered vehicles, were developed to estimate the energy consumption of vehicles on the corridor. A comprehensive full factorial simulation study was performed. The simulation results indicate that for a traffic mix based on projected new vehicles sales in 2025, a 15% corridor-level energy consumption reduction can be achieved. The paper details the development and validation of the simulation framework, design of experiments conducted, a discussion of challenges faced, and results under various test conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IDAC-Bio, A Software for Internal Dosimetry Based on the New ICRP Biokinetic Models and Specific Absorbed Fractions

Radiation dosimetry is central to virtually all radiation safety applications, optimization, and research. It relates to various individuals and population groups and to miscellaneous exposure situations—including planned, existing, and emergency situations. The International Commission on Radiological Protection (ICRP) has developed a new computational framework for internal dose estimations. Important components are more detailed and improved anatomical models and more realistic biokinetic models than before. The ICRP is currently producing new organ dose and effective dose coefficients for occupational intakes of radionuclides (OIR) and environmental intakes of radionuclides (EIR), which supersede the earlier dose coefficients in Publication 68 and the Publication 72 series, respectively. However, the ICRP only publishes dose coefficients for a single acute intake of a radionuclide and for an integration period of 50 years for intake by adults and to age 70 years for intakes by pre-adults. The new software, IDAC-Bio, performs committed absorbed dose and effective dose calculations for a selectable intake scenario, e.g., for a continuous intake or an intake during x hours per day and y days per week, and for any selected integration time. The software uses the primary data and models of the ICRP biokinetic models and numerically solves the biokinetic model and calculates the absorbed doses to organs and tissues in the ICRP reference human phantoms. The software calculates absorbed dose using the nuclear decay data in ICRP publication 107. IDAC-Bio is a further development and an important addition to the internal dosimetry program IDAC-Dose2.1. Here, the results generated by the software were validated against published ICRP dose coefficients. The potential of the software is illustrated by dose calculations for a nuclear power plant worker who had been exposed to varying levels of 60 Co and who had undergone repeated whole-body measurements, and for a hypothetical member of the public subject to future releases of 148 Gd from neutron spallation in tungsten at the European Spallation Source.

61 RADIATION PROTECTION AND DOSIMETRY↗

CheKiPEUQ Intro 1: Bayesian Parameter Estimation Considering Uncertainty or Error from both Experiments and Theory**

A common goal is extraction of physico-chemical parameter values such as pre-exponentials and activation energies from experiment. Ever increasing knowledge from experiments and computations is enabling semi-quantitative prior predictions of such values. When prior knowledge of physically realistic ranges is available, a method named Bayesian parameter estimation (BPE) enables more physically realistic parameter estimation relative to unsophisticated fitting by seeking the most probable value when considering together the uncertainties from prior knowledge, experimental data, and approximations in the model. An impediment to widespread use of BPE is a lack of understanding, training, and user-friendly software. Along with this invited publication, a general software package for BPE is being released that is user-friendly and that does not require understanding of the math behind the methodology. Overall, two previously unpublished catalysis science examples are provided along with considerations and guidelines for successful application of BPE. Following this work, BPE can become more widespread to enable extraction of physically meaningful parameter values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal-striping analysis methodology for sodium-cooled reactor design

Computational fluid dynamics simulations have been performed to study the applicability of engineering CFD methods for thermals striping analysis. Thermal striping is the fluctuating temperature profile in a solid caused by fluctuating fluid temperature, and the resulting fluctuating thermal stresses cause high cycle fatigue and eventual material failure. Here this study presents the methodology for thermal striping analysis that including a transient conjugate heat transfer RANS model and benchmark the results against a sodium triple jet experiment. The multiphysics calculations are implemented to analyze the thermal stresses in the solid domain caused by the coupled heat transfer between the fluid and solid domains. Validation data from a liquid sodium triple jet experiment include time-averaged temperature measurements and power spectra of the temperature signal. The numerical results agree well with these experimental measures, demonstrating key features such as the dominant frequency of temperature fluctuations. The applicability of a low-cost wall treatment method is demonstrated, enabling key computational savings. Finally, the performance of two finite element stress analysis software packages is compared, and the validity of the lower-cost method is confirmed. These results demonstrate the applicability of engineering methods for computational thermal striping calculations, enabling thermal striping estimations in large fluid systems such as the core of a Sodium-cooled nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗