Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

OSRP Source Repatriations-Case Studies: Brazil, Ecuador, Uruguay

The Global Threat Reduction Initiative's (GTRI) Offsite Source Recovery Project (OSRP) began recovering excess and unwanted radioactive sealed sources (sources) in 1999. As of February 2012, the project had recovered over 30,000 sources totaling over 820,000 Ci. OSRP grew out of early efforts at Los Alamos National Laboratory (LANL) to recover disused excess Plutonium- 239 (Pu-239) sources that were distributed in the 1960's and 1970's under the Atoms for Peace Program. Source recovery was initially considered a waste management activity. However, after the 9/11 terrorist attacks, the interagency community began to recognize that excess and unwanted radioactive sealed sources pose a national security threat, particularly those that lack a disposition path. After OSRP's transfer to the U.S. National Nuclear Security Administration (NNSA) to be part of GTRI, its mission was expanded to include all disused sealed sources that might require national security consideration. Recognizing the transnational threat posed by porous borders and the ubiquitous nature of sources, GTRI/OSRP repatriates U.S. origin sources based on threat reduction prioritization criteria. For example, several recent challenging source repatriation missions have been conducted by GTRI/OSRP in South America. These include the repatriation of a significant amount of Cs-137 and other isotopes from Brazil; re-packaging of conditioned Ra-226 sources in Ecuador for future repatriation; and, multilateral cooperation in the consolidation and export of Canadian, US, and Indian Co-60/Cs-137 sources from Uruguay. In addition, cooperation with regulators and private source owners in other countries presents opportunities for GTRI/OSRP to exchange best practices for managing disused sources. These positive experiences often result in long-term cooperation and information sharing with key foreign counterparts. International source recovery operations are essential to the preservation of U.S. national security interests. They are also mutually beneficial for fostering positive relationships with other governments and private industry, and demonstrate that responsible end-of-life options are given to legacy U.S.-origin sources in other countries. GTRI/OSRP does not take back sources that have a viable path for commercial disposal. Most US origin sources were sold commercially and were not provided by the US government. Below is a synopsis of cooperative efforts with Brazil, Ecuador, and Uruguay. Bilateral and multilateral efforts have been successful in removing hundreds of U.S.origin sealed radioactive sources from Latin American countries to the U.S. As many disused sources remain in the region, and since repatriation is not always an option, GTRI will continue to work with those countries to ensure that these sources are stored securely for the long-term. Successful Latin America operations should serve as a model for other regional cooperation in the repatriation of sealed sources, encouraging other source exporting countries to implement similar programs. Securing and removing sources, both domestically and internationally, is crucial to strengthening the life-cycle management of radioactive sources worldwide. Such efforts not only prevent these materials from being used maliciously, but also address public health and safety concerns, and under-gird the IAEA Code of Conduct on the Safety and Security of Radioactive Sources. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Selection of Russian Plutonium Beryllium Sources for Inclusion in the Nuclear Mateirals Information Program Archive

Throughout the 1960s and 1970s, the former Soviet Union produced and exported Plutonium-Beryllium (PuBe) neutron sources to various Eastern European countries. The Russian sources consist of an intermetallic compound of plutonium and beryllium encapsulated in an inner welded, sealed capsule and consisting of a body and one or more covers. The amount of plutonium in the sources ranges from 0.002 g up to 15 g. A portion of the sources was originally exported to East Germany. A portion of these sources were acquired by Los Alamos National Laboratory (LANL) in the late 1990s for destruction in the Offsite Source Recovery Program. When the OSRP was canceled, the remaining 88 PuBe neutron sources were packaged and stored in a 55-gal drum at T A-55. This storage configuration is no longer acceptable for PuBe sources, and the sources must either be repackaged or disposed of. Repackaging would place the sources into Hagan container, and depending on the dose rates, some sources may be packaged individually increasing the footprint and cost of storage. In addition, each source will be subject to leak-checking every six months. Leaks have already been detected in some of the sources, and due to the age of these sources, it is likely that additional leaks may be detected over time, which will increase the overall complexity of handling and storage. Therefore, it was decided that the sources would be disposed of at the Waste Isolation Pilot Plant (WIPP) due to the cost and labor associated with continued storage at TA-55. However, the plutonium in the sources is of Russian origin and needs to be preserved for research purposes. Therefore, it is important that a representative sample of the sources retained and archived for future studies. This report describes the criteria used to obtain a representative sample of the sources. Nine Russian PuBe neutron sources have been selected out of a collection of 77 sources for inclusion in the NMIP archive. Selection criteria were developed so that the largest sources that are representative of the collection are included. One representative source was chosen for every 20 sources in the collection, and effort was made to preserve sources unique to the collection. In total, four representative sources and five unique sources were selected for the archive. The archive samples contain 40 grams of plutonium with an isotopic composition similar to that of weapon grade material and three grams of plutonium with an isotopic composition similar to that of reactor grade plutonium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An ideal sealed source life-cycle

In the last 40 years, barriers to compliant and timely disposition of radioactive sealed sources have become apparent. The story starts with the explosive growth of nuclear gauging technologies in the 1960s. Dozens of companies in the US manufactured sources and many more created nuclear solutions to industrial gauging problems. Today they do not yet know how many Cat 1, 2, or 3 sources there are in the US. There are, at minimum, tens of thousands of sources, perhaps hundreds of thousands of sources. Affordable transportation solutions to consolidate all of these sources and disposition pathways for these sources do not exist. The root problem seems to be a lack of necessary regulatory framework that has allowed all of these problems to accumulate with no national plan for solving the problem. In the 1960s, Pu-238 displaced Pu-239 for most neutron and alpha source applications. In the 1970s, the availability of inexpensive Am-241 resulted in a proliferation of low energy gamma sources used in nuclear gauging, well logging, pacemakers, and X-ray fluorescence applications for example. In the 1980s, rapid expansion of worldwide petroleum exploration resulted in the expansion of Am-241 sources into international locations. Improvements of technology and regulation resulted in a change in isotopic distribution as Am-241 made Pu-239 and Pu-238 obsolete. Many early nuclear gauge technologies have been made obsolete as they were replaced by non-nuclear technoogies. With uncertainties in source end of life disposition and increased requirements for sealed source security, nuclear gauging technology is the last choice for modern process engineering gauging solutions. Over the same period, much was learned about licensing LLW disposition facilities as evident by the closure of early disposition facilities like Maxey Flats. The current difficulties in sealed source disposition start with adoption of the NLLW policy act of 1985, which created the state LLW compact system they we have today. This regulation created a new regulatory framework seen as promising at the time. However, now they recognize that, despite the good intentions, the NIJWP/85 has not solved any source disposition problems. The answer to these sealed source disposition problems is to adopt a philosophy to correct these regulatory issues, determine an interim solution, execute that solution until there is a minimal backlog of sources to deal with, and then let the mechanisms they have created solve this problem into the foreseeable future. The primary philosophical tenet of the ideal sealed source life cycle follows. You do not allow the creation (or importation) of any source whose use cannot be justified, which cannot be affordably shipped, or that does not have a well-delinated and affordable disposition pathway. The path forward dictates that we fix the problem by embracing the Ideal Source Life cycle. In figure 1, we can see some of the elements of the ideal source life cycle. The life cycle is broken down into four portions, manufacture, use, consolidation, and disposition. These four arbitrary elements allow them to focus on the ideal life cycle phases that every source should go through between manufacture and final disposition. As we examine the various phases of the sealed source life cycle, they pick specific examples and explore the adoption of the ideal life cycle model.

61 RADIATION PROTECTION AND DOSIMETRY↗

EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 {sup 137}Cs brachytherapy source models

Purpose: AAPM TG-56 recommends the use of a specific dosimetric dataset for each brachytherapy source model. In this study, a full dosimetric dataset for indigenously developed {sup 137}Cs source models, namely, the CSA1 and CSA2, in accordance with the AAPM TG-43U1 formalism is presented. The study includes calculation of dose-to-kerma ratio D/K in water around these sources including stainless steel encapsulated {sup 137}Cs sources such as RTR, 3M, and selectron/LDR {sup 137}Cs. Methods: The Monte Carlo-based EGSnrcMP code system is employed for modeling the sources in vacuum and in water. Calculations of air-kerma strength, S{sub K} for the investigated sources and collision kerma in water along the transverse axis of the RTR source are based on the FLURZnrc code. Simulations of water-kerma and dose in water for the CSA1, CSA2, RTR, 3M, and selectron/LDR {sup 137}Cs sources are carried out using the DOSRZnrc code. In DOSRZnrc calculations, water-kerma and dose are scored in a cylindrical water phantom having dimensions of 80 cm diameterx80 cm height. Results: The calculated dose-rate constants for the CSA1 and CSA2 sources are 0.945(1) and 1.023(1) cGy/(h U), respectively. The calculated value of S{sub K} per unit source activity, S{sub K}/A for the CSA1 and CSA2 sources is 7.393(7)x10{sup -8} cGy cm{sup 2}/(h Bq). The EGSnrcMP-based collision kerma rates for the RTR source along the transverse axis (0.25-10 cm) agree with the corresponding GEANT4-based published values within 0.5%. Anisotropy profiles of the CSA1 and CSA2 sources are significantly different from those of other sources. For the selectron/LDR single pellet {sup 137}Cs spherical source (modeled as a cylindrical pellet with dimensions similar to the seed selectron), the values of D/K at 1 and 1.25 mm from the capsule are 1.023(1) and 1.029(1), respectively. The value of D/K at 1 mm from the CSA1, CSA2, RTR, and 3M {sup 137}Cs source capsules (all sources have an external radius of 1.5 mm) is 1.017(1) and this ratio is applicable to axial positions z=0 to z={+-}L/2. This is in contrast to a published GEANT4-based Monte Carlo dosimetric study on RTR and 3M {sup 137}Cs sources wherein the authors have assumed that collision kerma is approximately equal to absorbed dose at 1 mm from the source capsules. Collision kerma is approximately equal to absorbed dose for distances {>=}2 mm from source capsules as opposed to {>=}1 mm reported in published studies. A detailed electron transport is necessary up to 2 mm from source capsules. Conclusions: The Monte Carlo-calculated dose-rate data for the CSA1 and CSA2 sources can be used as input data for treatment planning or to verify the calculations by radiotherapy treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗