Search NASA⌕ Search

SEARCH · Search NASA

Results for “system software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

MCCCS-MN

The MCCCS‒MN (Monte Carlo for Complex Chemical Systems‒Minnesota) software is developed by the Siepmann research group at the University of Minnesota. MCCCS‒MN allows for the simulation of multi-component molecular systems in the canonical, isobaric-isothermal (including constant stress for solids), grand-canonical, semi-grand, and Gibbs (NVT, NPT, and more than two simulation boxes) ensembles. It uses the configurational-bias Monte Carlo method to efficiently sample phase space for linear, branched and cyclic chain molecules, the adiabatic nuclear and electronic sampling Monte Carlo method to treat many-body polarization effects, and the aggregation-volume-bias Monte Carlo algorithm to efficiently sample the spatial distribution of associating molecules. MCCCS-MN employs a molecular representation of the system where force fields contain bonded and non-bonded terms. Funding for the development of MCCCS-MN through grants from the National Science Foundation (simulation of fluid phase equilibria and chromatography) and the Department of Energy (simulation of adsorption equilibria) is gratefully acknowledged.

Siepmann, J.Ilja [University of Minnesota - Twin C↗

System and method of managing large data files

Disclosed are systems and software that provide a high-performance, extensible file format and web API for remote data access and a visual interface for data viewing, query, and analysis. The described system can support storage of raw spectroscopic data such as neural recording data, MSI data, metadata, and derived analyses in a single, self-describing format that may be compatible by a large range of analysis software.

Bowen, Benjamin P.↗

Long-term Spot Stability in the Post-common-envelope Binary QS Vir

We observed the post-common-envelope eclipsing binary with a white dwarf component, QS Vir, using the 1.88 m telescope of Kotammia Observatory in Egypt. The new observations were analyzed together with all multicolor light curves available online (sampling a period of 25 yr), using a full-feature binary system modeling software based on Roche geometry. This is the first time complete photometric modeling was done with most of these data. QS Vir is a detached system, with the red dwarf component underfilling its Roche lobe by a small margin. All light curves feature out-of-eclipse variability that is associated with ellipsoidal variation, mutual irradiation and irregularities in surface brightness of the tidally distorted and magnetically active red dwarf. We tested models with one, two, and three dark spots and found that one spot is sufficient to account for the light curve asymmetry in all data sets, although this does not rule out the presence of multiple spots. We also found that a single spotted model cannot fit light curves observed simultaneously in different filters. Instead, each filter requires a different spot configuration. To thoroughly explore the parameter space of spot locations, we devised a grid-search procedure and used it to find consistent solutions. Based on this, we conclude that the dark spot responsible for light curve distortions has been stable for the past 15 yr, after a major migration that happened between 1993 and 2002, possibly due to a flip-flop event.

79 ASTRONOMY AND ASTROPHYSICS↗

Peregrine

The purpose of “Peregrine” is to perform in-situ quality control of the additive manufacturing process in powder bed systems. The software is an AI-based method to automatically detect and map multiple classes of defects present in the top layer of a powder bed system, either after material deposition, i.e. raking, or after printing the layer. Relying on image data or sensing modalities that can be converted into image data, the code allows for: (1) various steps of pre-processing of the data (registration, distortion correction, etc), (2) annotation of training datasets, (3) processing of data inline or offline, (4) creating 3D rendering of the defect map, and (5) implementation of corrective actions if allowed by the manufacturing platform.

Paquit, Vincent C↗

Testing and Validation of Wireless Communication Architecture for Heliostat Fields: SIPS Final Report

This work focuses on the development and testing of a low-cost wireless communication system for heliostat fields, enabling significant capital costs reductions for concentrating solar thermal systems. Outputs of this work include a working demonstration of a multi-node communication system, clear reporting of system performance, and technical documentation of system development and architecture for reproducibility. Through this process, an open-source repository was created for manufacturing hardware at ~$30/heliostat. The system includes software for cybersecurity, achieving sub-second communication latencies and derisking of hardware for eventual scale-up to tens of thousands of heliostats. While the system is not currently off-the-shelf ready, there is now a clearly defined pathway for scaling up and completing the commercial development process.

14 SOLAR ENERGY↗

A streamlined build system foundation for developing HPC software

BLT bundles custom CMake macros, unit testing frameworks for C++ and Fortran, and a set of smoke tests for common HPC dependencies. The combination of these three provides a foundation for quickly bootstrapping a CMale-based system for developing HPC softward.

White, Chris↗

Improving Performance via Energy Efficiency JUSTIFI: Open-Source Software for Identifying and Quantifying Non-Energy Benefits

Energy efficiency is pivotal to achieving operational excellence, as it enhances value while reducing waste. This presentation explores the integration of non-energy benefits (NEBs) into energy efficiency projects, which can lead to risk reduction, value creation, and cost savings. By quantifying NEBs - such as improved safety, decreased pollution, and increased productivity - companies can strengthen their business cases for energy investments, ultimately improving payback periods and aligning with strategic goals. Designed for a diverse audience, from trained auditors to novices in energy assessments, we have developed open-source software called JUSTIFI, NEB finding methodology, and training materials which build on existing frameworks and leverages resources from the U.S. Department of Energy and Better Plants energy system analysis software suite such as MEASUR. This work aims to maximize ROI through NEB identification, utilizing tools like JUSTIFI and the NEBs Discovery Protocol.

97 MATHEMATICS AND COMPUTING↗

JSATS Detector Field Manual

The Juvenile Salmon Acoustic Telemetry System (JSATS) Detector is a software and hardware system that captures JSATS Acoustic Micro Transmitter (AMT) signals. The system uses hydrophones to capture acoustic signals in the water. This analog signal is then amplified and processed by the Analog to Digital Converter (ADC) and Digital Signal Processor (DSP) board in the computer. This board digitizes and processes the acoustic signal to determine if a possible JSATS tag is present. With this detection, the data will be saved to the computer for further analysis. This document details the features and functionality of the JSATS Detector software. The document covers how to install the software, setup and run the detector software. The document will also go over the raw binary waveform file format and CSV files containing RMS values

47 OTHER INSTRUMENTATION↗

Maximum Switching Throughput Density Estimator

SAND2024-11125O The Maximum Switching Throughput Density Estimator software performs a simple analysis that estimates the maximum logic switching throughput density that’s achieved in various CMOS technology nodes on the International Roadmap for Devices and Systems. This software utilizes simple device models and optimization techniques, performing a simple sweep over a range of possible logic supply voltages, and analytically calculating the maximum switching frequency for the given logic voltage that meets the power density constraint. It does this by using simple models of power dissipation in conventional and fully adiabatic switching. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Frank, Michael↗

Attributes of Securable Architectures

As cyber-security is becoming more and more important in systems development, engineers have begun to recognize and understand the types of errors they can introduce through hurried coding technique and design. This overall trend is certainly moving the software industry in the right direction and can lead to developing higher quality software-centric systems. Unfortunately, we have barely begun to examine the results of poor architectural choices, nor do we have much insight into what secure and securable architectures look like. In this paper, based on the past 40 years of work identifying specific security principles, we create a taxonomy of principles that address the abstract cyber-security needs of systems. We then tie these principles to studies of insecure systems architectures to demonstrate applicability. We close the paper with a description of other cyber-security taxonomies, how they specifically differ from this presented taxonomy, and add new principles to address gaps shown in taxonomic comparisons.

97 MATHEMATICS AND COMPUTING↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

SU-E-T-106: Development of a Collision Prediction Algorithm for Determining Problematic Geometry for SBRT Treatments Using a Stereotactic Body Frame

Purpose: Collision between the gantry and the couch or patient during Radiotherapy is not a common concern for conventional RT (static fields or arc). With the increase in the application of stereotactic planning techniques to the body, collisions have become a greater concern. Non-coplanar beam geometry is desirable in stereotatic treatments in order to achieve sharp gradients and a high conformality. Non-coplanar geometry is less intuitive in the body and often requires an iterative process of planning and dry runs to guarantee deliverability. Methods: Purpose written software was developed in order to predict the likelihood of collision between the head of the gantry and the couch, patient or stereotatic body frame. Using the DICOM plan and structures set, exported by the treatment planning system, this software is able to predict the possibility of a collision. Given the plan's isocenter, treatment geometry and exterior contours, the software is able to determine if a particular beam/arc is clinically deliverable or if collision is imminent. Results: The software was tested on real world treatment plans with untreatable beam geometry. Both static non-coplanar and VMAT plans were tested. Of these, the collision prediction software could identify all as having potentially problematic geometry. Re-plans of the same cases were also tested and validated as deliverable. Conclusion: This software is capable of giving good initial indication of deliverability for treatment plans that utilize complex geometry (SBRT) or have lateral isocenters. This software is not intended to replace the standard pre-treatment QA dry run. The effectiveness is limited to those portions of the patient and immobilization devices that have been included in the simulation CT and contoured in the planning system. It will however aid the planner in reducing the iterations required to create complex treatment geometries necessary to achieve ideal conformality and organ sparing.

60 APPLIED LIFE SCIENCES↗

NeuroFEM

SAND2025-00525O NeuroFEM is a software tool that demonstrates a neuromorphic algorithm for solving finite element problems. It sets up a 2D finite element problem for the Poisson equation on a disk, constructs synaptic matrices, and simulates neural dynamics to solve the resulting sparse linear system. The software illustrates how the algorithm converges to the solution and plots the results, showcasing a neuromorphic counterpart to traditional methods like Conjugate Gradient or GMRES. This tool is designed to highlight the potential of neuromorphic algorithms for solving sparse linear systems, which are prevalent in various computational applications. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

Best-estimate plus uncertainty thermal-hydraulic stability analysis of BWRs using TRACG code

Over the last decade, Boiling Water Reactor (BWR) power up-rates have increased plant rated power output significantly. Subsequent projects have expanded flow domains (e.g. MELLLA+) for operation at these higher power levels. This has resulted in an increase in the power to flow ratio in regions susceptible to reactor thermal-hydraulic instabilities. Since BWRs are susceptible to coupled thermal-hydraulic/nuclear oscillations when operating at these conditions, such oscillations must be prevented or reliably detected and suppressed. The Detect and Suppress Solution - Confirmation Density (DSS-CD) is the most sophisticated GEH BWR instability protection system ever employed. DSS-CD implements algorithms that monitor closely-spaced groups of Local Power Range Monitor (LPRM) detectors to detect periodic behavior typical of reactor instability events. This system is able to detect small, localized power variations in the core, distinguish between true instabilities and plant noise, and trip/scram the reactor while maintaining adequate safety margins. The combination of hardware, software, and system setpoints provides protection against violation of the Safety Limit Minimum Critical Power Ratio (SLMCPR) for anticipated oscillations. To support DSS-CD implementation, the TRACG system code is used to simulate events to confirm the capability of the DSS-CD solution for early oscillation detection and suppression. TRACG is a GEH proprietary version of the Transient Reactor Analysis Code (TRAC). TRACG includes a multi-dimensional, two-fluid model for the reactor thermal-hydraulics and a three-dimensional reactor kinetics model. The models are qualified to simulate a large variety of tests and reactor configurations, including thermal-hydraulic stability events. These features allow for detailed, best-estimate simulation of a wide range of BWR phenomena. A set of integrated TRACG event simulations for reasonably limiting anticipated events can be used to calculate the effect on the Minimum Critical Power Ratio (MCPR) performance. The purpose of the DSS-CD TRACG analysis is to confirm the inherent MCPR margin afforded by the solution design. This paper presents the Best Estimate Plus Uncertainty (BEPU) DSS-CD TRACG methodology and its application to BWR Thermal-Hydraulic (T-H) stability analyses. The statistical Code Scaling, Applicability and Uncertainty (CSAU) methodology (defined in NUREG/CR-5249) is used to calculate the MCPR uncertainty. The TRACG simulation includes a full core individual bundle model in which each fuel bundle is modeled as an individual T-H channel. The complete CSAU analysis of full core individual bundle model is an innovative solution represents the state-of-the-art stability analysis of BWRs and is the first ever full statistical analysis for stability safety analyses. The adoption of BEPU methodologies for stability analyses advances the understanding of the associated physical phenomena and maintains the safety of reactor plant operation in expanded operation domain with up-rated power. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BatteryPro: A Python Toolkit for Battery Data Analysis and Machine Learning Predictions

Analyzing battery test data for research & development can be time-consuming since battery tests often run on the order of months to years, generating large volumes of data. BatteryPro is a comprehensive Python package and software designed to facilitate advanced analysis and performance predictions for battery test data. Developed for battery researchers, it supports data types from widely used battery testing instruments, including MACCOR and Biologic cycling systems. The software provides a variety of tools for extracting and plotting key battery parameters such as time, voltage, capacity, current, and pressure. In addition to its extensive data analysis capabilities, BatteryPro features a dedicated machine learning module that employs a Bayesian Gaussian Mixture Model (GMM) to predict battery performance and degradation. Users can generate synthetic capacity fade data, calculate fade metrics, and leverage predictive models to forecast long-term battery behavior. The software's graphical user interface (GUI) enhances usability, allowing researchers to upload, merge, and analyze multiple data files with full customizability. The GUI also supports machine learning predictions, enabling users to fit models and make predictions based on selected data and parameters. BatteryPro is built using QtDesigner, scikit-learn, matplotlib, and pandas, ensuring a high level of customization, flexibility, and accuracy in battery data analysis. This tool aims to empower researchers with the ability to perform detailed battery analysis and make informed predictions, ultimately advancing the field of battery research.

25 - ENERGY STORAGE↗

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2021 NIRT Mini Drill (After Action Report)

During the summer and fall of 2021, several functional area drills were held that focused on exercising Consequence Management’s (CM) ability to extract and use data from RadResponder for the purpose of answering intermediate-phase questions presented as technical inject requests for information (RFI) in Sandia National Laboratories (SNL) Consequence Management Operational System (COSMOS) software. The scenario chosen was that of Northern Lights 2016 (NL16) which was a large-scale nuclear power plant (NPP) release exercise in the state of Minnesota. The NL16 data was extracted from the Radiological Assessment and Monitoring System (RAMS) event where it was created and was reformatted for implanting to a new RadResponder event. Next, the beta-version of a laboratory sample data simulator was used to generate more sample data that was injected to the event. Five “mini-drills” were devised with each prompt defined by a data-based need. For each drill, a team of assessment and NARAC scientists worked the problem using the drill prompt and the available data in RadResponder. The teams held a kickoff meeting, had several days to work the problem, and then reported their results as well as observations in a hotwash. Several areas for improvement in both the software and process were identified during the course of these drills. This report will document the process of addressing each RFI and the discovered gaps in both software capability and methodology so that they can be considered for future development and investment by the CM and NIRT programs.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗