Search NASA⌕ Search

SEARCH · Search NASA

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources: Preprint

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their \textit{autonomy} and \textit{privacy} through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

Aggregation of Real-Time System Monitoring Data for Analyzing Large-Scale Parallel and Distributed Computing Environments

We present a monitoring system for large-scale parallel and distributed computing environments that allows to trade-off accuracy in a tunable fashion to gain scalability without compromising fidelity. The approach relies on classifying each gathered monitoring metric based on individual needs and on aggregating messages containing classes of individual monitoring metrics using a tree-based overlay network. The MRNet-based prototype is able to significantly reduce the amount of gathered and stored monitoring data, e.g., by a factor of ~56 in comparison to the Ganglia distributed monitoring system. A simple scaling study reveals, however, that further efforts are needed in reducing the amount of data to monitor future-generation extreme-scale systems with up to 1,000,000 nodes. The implemented solution did not had a measurable performance impact as the 32-node test system did not produce enough monitoring data to interfere with running applications.

97 MATHEMATICS AND COMPUTING↗

SRF Test Areas Cryogenic System Controls Graphical User Interface

Fermi National Accelerator Laboratory has constructed a superconducting 1.3 GHz cavity test facility at Meson Detector Building (MDB) and a superconducting 1.3 GHz cryomodule test facility located at the New Muon Lab Building (NML). The control of these 2K cryogenic systems is accomplished by using a Synoptic graphical user interface (GUI) to interact with the underlying Fermilab Accelerator Control System. The design, testing and operational experience of employing the Synoptic client-server system for graphical representation will be discussed. Details on the Synoptic deployment to the MDB and NML cryogenic sub-systems will also be discussed. The implementation of the Synoptic as the GUI for both NML and MDB has been a success. Both facilities are currently fulfilling their individual roles in SCRF testing as a result of successful availability of the cryogenic systems. The tools available for creating Synoptic pages will continue to be developed to serve the evolving needs of users.

43 PARTICLE ACCELERATORS↗

Verification test suite for systems analysis tools

This report documents strategies and test problems to support Verification and Validation (V&V) of the systems analysis tools currently being developed under the Reactor Product Line (RPL) of DOE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. A suite of verification test cases has been developed. This test suite supports development of new codes as well as maintenance of existing codes. For advanced tools that are under development like RELAP-7 for light water reactor analysis [1] and the MOOSE based component models for SFR (M-SFR) analyses [2], verification of simulation results must be performed throughout the entire development phase. This test suite is also useful for established codes as part of automated testing to ensure that general code maintenance does not change existing results.

Sumner, T.↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Role of Concentrating Solar Power Toward High Renewable Energy Penetrated Power Systems

Achieving high renewable energy penetrated power systems requires considerable operational flexibility to hedge the variability and uncertainty of variable renewable energy (VRE) generation. Compared with VRE sources, concentrating solar power (CSP) is an emerging controllable renewable generation technique that utilizes solar thermal power to generate electricity. The operational dispatchability of CSP would contribute to the power system transition toward high renewable penetration. In this paper, we explore how the generation portfolio will change toward high renewable energy penetrations, how much cost is involved, and what role CSP will play in realizing a high renewable energy penetrated power system. This study relies on a stochastic two-stage generation and transmission expansion planning model with CSP plants. The model captures the uncertainty and variability of renewable generation and the flexibility limits of thermal plants. With the target of achieving a renewable-dominated minimum-cost system with an expected renewable energy penetration level, the investments of both generation and transmission facilities are optimized. A case study on IEEE test systems with renewable technology cost data in 2050 is performed to analyze the value of CSP toward high renewable energy penetrated power systems.

14 SOLAR ENERGY↗

Assessment of Prototypic and Closed Loop Operation during Pulse Jet Mixer Tests with Non-Cohesive Solids to Develop Scale-up Relationships

Scaled tests were conducted to develop correlations describing pulse jet mixer (PJM) performance with non-cohesive solids in water. These correlations were developed in scaled test systems that incorporated certain simplified aspects including non-prototypic refill associated with closed-loop operation of the mixing jets. When this test data was compared with experiments that used prototypic PJM refill, a difference in the critical suspension velocity (UCS) was identified. The non-prototypic aspects of the initial testing were reviewed and assessed. The effects of non-prototypic refill associated with the closed loop operation of the jets, previously known to affect solids cloud height, can be described in terms of a modified settling velocity. When the modified settling velocity is incorporated into the physical model, the adjusted new physical model does a better job of predicting UCS results for prototypic PJM refill tests. The adjusted new physical model was bench-marked with data taken during three prototypic drive tests with a mono-disperse simulant, a 3-part medium distribution stimulant and a 5-part broad distribution simulant The applicability of the non-prototypic scale-up behavior to prototypic testing was analyzed. The effects of non-prototypic refill caused measured values of UCS to be somewhat reduced at larger scales. Hence the scale-up exponents for the non-prototypic drive tests are believed to be smaller than they would have been had there been prototypic refill. Estimated scale-up exponents for the prototypic testing were developed for 8 and 12 pulse tube configurations.

comparison between prototypic and simplified drive↗

Machine Protection System Research and Development for the Fermilab PIP-II Proton Linac

PIP-II is a high intensity proton linac being design to support a world-leading physics program at Fermilab. Initially it will provide high intensity beams for Fermilab's neutrino program with a future extension to other applications requiring an upgrade to CW linac operation (e.g. muon experiments). The machine is conceived to be 2 mA CW, 800 MeV H⁻ linac capable of working initially in a pulse (0.55 ms, 20 Hz) mode for injection into the existing Booster. The planned upgrade to CW operation implies that the total beam current and damage potential will be greater than in any present HEP hadron linac. To mitigate the primary technical risk and challenges associated PIP-II an integrated system test for the PIP-II front-end technology is being developed. As part of the R&D a robust machine protection system (MPS) is being designed. This paper describes the progress and challenges associated with the MPS.

43 PARTICLE ACCELERATORS↗

Tank Side Cesium Removal for Hanford Tank Waste - Actual Waste Demonstrations - 20467

The US DOE and its contractors are evaluating several options for treating Hanford tank supernate streams to provide feed for the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant. At this time, the intent is to deploy a Tank-Side Cesium Removal system. The key unit operations for this process are filtration and cesium removal by ion exchange. To assess the anticipated performance of the system, tests with actual waste were performed with samples from Hanford tanks AW-102 and AP-107 to provide basis data regarding the performance of the system in treating these materials. The decanted supernate waste samples from tanks AW-102 and AP-107 were received directly by the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. These samples were then filtered to provide data on dead-end filtration with a Mott{sup TM} filter media grade 5. Subsequently, the samples were run through 10-milliliter ion exchange columns containing crystalline silicotitanate to assess the dynamic ion exchange performance of these feeds. Test results demonstrated that the planned TSCR operations should meet process performance expectations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are or could be practically implemented in a field test situation. These tests include: visual, infrared thermography, interdigital capacitance, indenter, relaxation time indenter, dynamic mechanical analyzer, infrared/near-infrared spectrometry, ultrasound, and distributed fiber optic temperature measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of programmable logic in a rapid, automated, and repeatable fashion for safety-related applications - 385

Digital safety platform considerations for power plant modernization or new build efforts involve a burdensome task of implementing a large number of software-based functions onto a designated platform to match the plant's architecture. This problem is not unique to any particular safety-related platform solution, but is prevalent across the landscape of current Qualified and Licensed Safety-related Instrumentation and Control (I and C) Solutions. As an example when implementing a RG 1.97 compliant Post Accident Monitoring System (PAMS) solution with the Lockheed Martin Nuclear Protection and Control (NuPAC) safety platform, 72 unique software loads are needed to configure the Qualified Display System (QDS). Large scale development and customization efforts to upgrade existing plant functions or systems require the licensee to assume the cost and technical risk necessary to undergo a digital based upgrade. Often the cost, schedule, and technical risk outweighed the benefit of modernization efforts due to the unknown hurdles and past projects that overran cost and schedule projections. Lockheed Martin's Engineering Production Suite (EPS) minimizes the licensee risk and expense associated with modernization efforts through a developer's toolkit for rapid, automated, and repeatable development of Programmable Logic used to implement plant functions and architectures for use on the Lockheed Martin NuPAC platform. This paper describes a use case where by EPS can create system level representations, simulate system functions, partition logic designs to accommodate hardware constraints through logic partitioning, automate the assembly of Application Specific Programmable Logic (ASPL), generate system test cases, program the NuPAC hardware, and perform testing throughout the design workflow. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NONDESTRUCTIVE DETECTION OF DELAMINATION IN THERMAL BARRIER COATINGS USING ULTRASONIC TECHNIQUE

Nondestructive testing using an acousto-ultrasonic technique has been utilized to detect the change of material properties and provide early warning of failure of thermal barrier coating (TBC) systems. Testing was performed on René N5 and Haynes 230 coupons with an applied NETL-bond coat, as well as on coupons containing both an applied MCrAlY bond coat and 7-YSZ top coat. The coupons were subjected to either cyclic or isothermal testing at 1100ºC. Ultrasonic testing was performed before and after thermal testing using piezoelectric sensors with dry contact on the surface of the coatings. Proof-of-concept test results indicated that changes in the properties of the 40m bond coat can be detected using the proposed technique. Waveforms generated via Pitch/Catch indicated minor changes within the bond coat applied to René N5 substrate after 400500 hours of cyclic oxidation at 1100°C. In contrast, marked differences in waveforms and travel time reflected significant crack formation and spallation of the bond coat from the Haynes 230 substrate. Finite element analysis (FEA) simulation of the wave propagation on a simplified TBC system with nonlinear effects was conducted. FEA results clearly show detection of a small embedded void incorporated to simulate delamination. Comparisons between experimental measurements and finite element simulations were used to estimate the material properties of the coatings and the substrate.

36 MATERIALS SCIENCE↗

Experience in connecting the power generating units of thermal power plants to automatic secondary frequency regulation within the united power system of Russia

The principles of central control of the power generating units of thermal power plants by automatic secondary frequency and active power overcurrent regulation systems, and the algorithms for interactions between automatic power control systems for the power production units in thermal power plants and centralized systems for automatic frequency and power regulation, are discussed. The order of switching the power generating units of thermal power plants over to control by a centralized system for automatic frequency and power regulation and by the Central Coordinating System for automatic frequency and power regulation is presented. The results of full-scale system tests of the control of power generating units of the Kirishskaya, Stavropol, and Perm GRES (State Regional Electric Power Plants) by the Central Coordinating System for automatic frequency and power regulation at the United Power System of Russia on September 23-25, 2008, are reported.

42 ENGINEERING↗

Caution on Using Tetrahydrofuran for Processing Crystalline Silica Samples From Engineered Stone for XRD Analysis

Abstract We conducted laboratory experiments to investigate a suspected effect of tetrahydrofuran (THF) on quantifying crystalline silica in samples collected from working with engineered stone when THF is used to process samples prior to the X-ray diffraction (XRD) analysis. Two groups of samples from grinding either engineered stone or granite were simultaneously taken from a laboratory testing system, with one group of samples using THF for processing and another group using muffle furnace for ashing. For each stone type, we also tested four levels of respirable dust loading on the samples by varying the grinding time from 1 to 8 min. Statistical analysis of the experimental results on crystalline silica contents of the two groups of samples showed that the difference between the two methods was not significant (P ≥ 0.05) for the granite at all four levels of respirable dust loading and for the engineered stone at the two levels of respirable dust loading greater than 0.5 mg. However, the crystalline silica content from using THF processing was significantly lower (P = 0.001) than that from using muffle furnace ashing for engineered stone when the respirable dust loading levels were less than 0.5 mg. For the engineered stone dust samples with grinding times of 1 and 2 min, the average respirable dust loading was about 0.19 and 0.34 mg, respectively; while the crystalline silica content from using THF processing was 30.9 and 21.5% lower than that from using muffle furnace ashing, respectively. Since most full-shift samples from field assessments in this industry are expected to have respirable dust loading less than 0.5 mg, muffle furnace or radio frequency plasma ashing should be specified as the preferred sample processing method instead of the THF processing method for quantification of crystalline silica when engineered stone is expected to present to avoid artificially reduced silica content values, which are likely caused by the reactions between THF and the resins in engineered stone.

Public, Environmental & Occupational Health↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

DistOPF: Advanced Solutions for Distribution Optimal Power Flow Analysis - DistOPF v0.2 Documentation

To achieve an affordable and reliable energy system, research on power distribution system is often focused on integration of distributed generators, energy storage solution, EV charging, smart meters, and other advanced assets that may benefit from or require more advanced control and optimization techniques. Despite this focus on advanced distribution system topics, early researchers and grid scientists often start from scratch when developing optimization programs for power distribution systems. This report introduces DistOPF, a Python package that consolidates years of research into a versatile and modular tool. DistOPF provides researchers with essential capabilities to solve distribution system Optimal Power Flow (OPF) problems using standard network models. Additionally, it offers a platform to benchmark both new and existing algorithms against established test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗