Search NASA⌕ Search

SEARCH · Search NASA

Results for “time shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Gain Shift Corrections at Chi-Nu

Ambient conditions have the potential to cause changes in liquid scintillator detector gain that vary with time and temperature. These gain shifts can lead to poor resolution in both energy as well as pulse shape discrimination. In order to correct for these shifts in the Chi-Nu high energy array, a laser system has been developed for calibration of the pulse height signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion neutral coupling in the high latitude thermosphere, part 1

Measurements of the neutral wind in the polar F region from Dynamics Explorer-2 (DE-2) were used to illustrate asymmetries in the neutral circulation that are dependent on the sign of the B sub y component of the interplanetary magnetic field (IMF). Individual DE-2 orbits and averaged data sets from different Universal times are presented. The data are categorized according to the sign of the hourly averaged IMF B sub y component measured by ISEE-3 for the hour preceding the DE-2 measurement. The major features observed are: (1) an asymmetry in the polar cap neutral flow velocity with the region of most rapid antisunward flow shifting from the dawn side to the dusk side of the polar cap as B sub y changes from positive to negative; (2) a shift in magnetic local time of the region of entry of neutral gas into the polar cap from a location on the dawn side of the noon-midnight meridian for B sub y positive to one more biased towards the dusk side for B sub y negative; (3) an enhancement in the velocities associated with the dawn, anti-clockwise neutral vortex B suby y negative relative to those observed for B sub y positive. The B sub y neutral wind asymmetries can be explained by similar asymmetries, previously observed, in the polar ion convection pattern. They imply a direct causal relationship between solar wind/magnetosphere coupling and neutral thermospheric dynamics.

Killeen, T. L.↗

Temporal Response of Nonequilibrium Correlated Electrons

In this work we examine the time-resolved, instantaneous current response for the spinless Falicov-Kimball model at half-filling, on both sides of the Mott-Hubbard metal-insulator transition, driven by a strong electric field pump pulse. The results are obtained using an exact, nonequilibrium, many-body impurity solution specifically designed to treat the out-of-equilibrium evolution of electrons in time-dependent fields. We provide a brief introduction to the method and its computational details. We find that the current develops Bloch oscillations, similar to the case of DC driving fields, with an additional amplitude modulation, characterized by beats and induced by correlation effects. Correlations primarily manifest themselves through an overall reduction in magnitude and shift in the onset time of the current response with increasing interaction strength.

COMP, MATSCI, OTHER↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Vector Analysis of Prostate Patient Setup With Image-Guided Radiation Therapy via kV Cone Beam Computed Tomography

Purpose: To analyze the daily setup variations in a cohort of intensity-modulated radiation therapy (IMRT) prostate cancer patients who had received daily image-guided RT without the use of fiducial markers to determine if daily image guidance is necessary. Methods and Materials: 2134 Kilovoltage (kV) cone beam computed tomography (CBCT) images were analyzed, with three shifts recorded for each image. The number of times that the vector of the combined shifts would have exceeded the planning tumor volume (PTV) margin was tallied. Then, the average scalar shift of the first five images was removed from all subsequent images for a given patient, and the number of days for which the shift vector was greater than the three-dimensional clinical tumor volume-PTV (3D CTV-PTV) margin (8 mm, created with rolling ball technique) was recorded. Additionally, the scalar shifts from every other fraction were studied to determine if the individual patient's shift vector would be adequately sampled if CBCT was not performed daily, thus reducing patient imaging dose without compromising treatment quality. Results: There were 297 cases where the vector shift was initially greater than the PTV margin. By correcting each patient's data set by the average shift of their first five images the total was 248 cases. By considering only every other image of each patient data set (after correction for the first 5 days), only 137 days in which the CTV was outside the PTV would have been seen. Conclusions: Daily imaging is recommended for prostate cancer IMRT patients in order to know the 3D (vector) position of the CTV and to ensure that it is always within the PTV margin. Correcting the data set by the average shift from the first 5 days reduces the overall number of outlier days but does not eliminate them completely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Observation of Molecular Spinning with Angular High-Harmonic Spectroscopy

We demonstrate an angular high-harmonic spectroscopy method to probe the spinning dynamics of a molecular rotation wave packet in real time. With the excitation of two time-delayed, polarization-skewed pump pulses, the molecular ensemble is impulsively kicked to rotate unidirectionally, which is subsequently irradiated by another delayed probe pulse for high-order harmonic generation (HHG). The spatiotemporal evolution of the molecular rotation wave packet is visualized from the time-dependent angular distributions of the HHG yields and frequency shift measured at various polarization directions and time delays of the probe pulse. Here, the observed frequency shift in HHG is demonstrated to arise from the nonadiabatic effect induced by molecular spinning. Different from the previous spectroscopic and Coulomb explosion imaging techniques, the angular high-harmonic spectroscopy method can reveal additionally the electronic structure and multiple orbitals of the sampled molecule. All the experimental findings are well reproduced by numerical simulations. Further extension of this method would provide a powerful tool for probing complex polyatomic molecules with HHG spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

An OVERVIEW of MICROPHONICS in CEBAF and CURRENT MODERATION TECHNIQUES

Superconducting RF (SRF) structures are susceptible to frequency detuning from external vibrations and modal mechanical resonances in the structure. These small disturbances, known as microphonics, require additional RF power in CW accelerating structures since the frequency is constantly shifting. In the Jefferson Lab CEBAF accelerator, time and frequency data of this frequency shift have been recorded for many years, allowing a retrospective analysis of different microphonics-mitigation techniques. Some of these techniques are specific to the design of each CEBAF cryomodule, for example implementing BNNT damping material on the cavity string. Other techniques are universal such as affixing vacuum lines and reinforcing waveguide structures.

Powers, Tom↗

Lifetime predictions for dimmable two-channel drivers for color tuning luminaires

Two-channel tunable white lighting (TWL) systems represent the next wave of solid-state lighting (SSL) systems and promise flexibility in light environment while maintaining the high reliability and luminous efficacy expected with SSL devices. TWL systems utilize LED assemblies consisting of two different LED spectra (i.e., often a warm white assembly and a cool white assembly) that are integrated into modules. While these systems provide the ability to adjust the lighting spectrum to match the physiology needs of the task at hand, they also are a potentially more complex lighting system from a performance and reliability perspective. We report an initial study on the reliability performance of such lighting systems including an examination of the lumen maintenance and chromaticity stability of warm white and cool white LED assemblies and the multi-channel driver that provides power to the assemblies. Accelerated stress tests including operational bake tests conducted at 75°C and 95°C were used to age the LED modules, while more aggressive temperature and humidity tests were used for the drivers in this study. Small differences in the performance between the two LED assemblies were found and can be attributed to the different phosphor chemistries. The lumen maintenances of both LED assemblies were excellent. The warm white LED assemblies were found to shift slightly in the green color direction over time while the cool white LED assemblies shifted slightly in the yellow color direction. The net result of these chromaticity shifts is a small, barely perceptible reduction in the tuning range after 6,000 hours of exposure to an accelerating elevated temperature of 75°C.

Chromaticity↗

A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view

An MLC control algorithm for delivering intensity modulated radiation therapy (IMRT) to targets that are undergoing two-dimensional (2D) rigid motion in the beam's eye view (BEV) is presented. The goal of this method is to deliver 3D-derived fluence maps over a moving patient anatomy. Target motion measured prior to delivery is first used to design a set of planned dynamic-MLC (DMLC) sliding-window leaf trajectories. During actual delivery, the algorithm relies on real-time feedback to compensate for target motion that does not agree with the motion measured during planning. The methodology is based on an existing one-dimensional (1D) algorithm that uses on-the-fly intensity calculations to appropriately adjust the DMLC leaf trajectories in real-time during exposure delivery [McMahon et al., Med. Phys. 34, 3211-3223 (2007)]. To extend the 1D algorithm's application to 2D target motion, a real-time leaf-pair shifting mechanism has been developed. Target motion that is orthogonal to leaf travel is tracked by appropriately shifting the positions of all MLC leaves. The performance of the tracking algorithm was tested for a single beam of a fractionated IMRT treatment, using a clinically derived intensity profile and a 2D target trajectory based on measured patient data. Comparisons were made between 2D tracking, 1D tracking, and no tracking. The impact of the tracking lag time and the frequency of real-time imaging were investigated. A study of the dependence of the algorithm's performance on the level of agreement between the motion measured during planning and delivery was also included. Results demonstrated that tracking both components of the 2D motion (i.e., parallel and orthogonal to leaf travel) results in delivered fluence profiles that are superior to those that track the component of motion that is parallel to leaf travel alone. Tracking lag time effects may lead to relatively large intensity delivery errors compared to the other sources of error investigated. However, the algorithm presented is robust in the sense that it does not rely on a high level of agreement between the target motion measured during treatment planning and delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plate motion controls on back-arc spreading

The motions of the subducting and the overriding plates influence the spatial and temporal distribution of back-arc spreading. Cenozoic plate motions in hot spot-fixed and no-net-rotation reference frames were studied with attention to correlations between changes in motion and episodes of back-arc spreading in the western Pacific. The results suggest that major back-arc opening occurs when both the overriding plate retreats from the trench in an absolute sense and the subducting plate undergoes a significant speed-up. Neither phenomenon alone is sufficient to initiate spreading. Three major plate velocity increases can be identified in the Cenozoic: (1) the Pacific plate 5-9 Ma; (2) the Indian plate at 27 Ma; and (3) the Pacific plate at 43 Ma, due to its shift from northerly to more westerly motion. At the present time, the Indian and Philippine are the only overriding plates that are retreating from their Pacific trenches and back-arc spreading occurs only on these two retreating plates. Although the Indian plate has been retreating for at least 25 Ma, back-arc spreading began only following the Pacific plate speed-up 5-9 Ma. Earlier, during the Indian plate speed-up, no overriding plates were retreating strongly and no back-arc spreading epsiodes are preserved from this time. For the earliest Pacific plate shift at 43 Ma, the Eurasian plate was not advancing, thus creating the only favorable plate kinematic conditions in the Cenozoic for back-arc basin formation in this region. It is unclear whether extension in the Japan Sea is a result of these conditions.

Fein, J. B.↗

Axial resonances a$_{1}$(1260), b$_{1}$(1235) and their decays from the lattice

The light axial-vector resonances $a_1(1260)$ and $b_1(1235)$ are explored in Nf=2 lattice QCD by simulating the corresponding scattering channels $\rho\pi$ and $\omega\pi$. Interpolating fields $\bar{q} q$ and $\rho\pi$ or $\omega\pi$ are used to extract the s-wave phase shifts for the first time. The $\rho$ and $\omega$ are treated as stable and we argue that this is justified in the considered energy range and for our parameters $m_\pi\simeq 266~$MeV and $L\simeq 2~$fm. We neglect other channels that would be open when using physical masses in continuum. Assuming a resonance interpretation a Breit-Wigner fit to the phase shift gives the $a_1(1260)$ resonance mass $m_{a1}^{res}=1.435(53)(^{+0}_{-109})$ GeV compared to $m_{a1}^{exp}=1.230(40)$ GeV. The $a_1$ width $\Gamma_{a1}(s)=g^2 p/s$ is parametrized in terms of the coupling and we obtain $g_{a_1\rho\pi}=1.71(39)$ GeV compared to $g_{a_1\rho\pi}^{exp}=1.35(30)$ GeV derived from $\Gamma_{a1}^{exp}=425(175)$ MeV. In the $b_1$ channel, we find energy levels related to $\pi(0)\omega(0)$ and $b_1(1235)$, and the lowest level is found at $E_1 \gtrsim m_\omega+m_\pi$ but is within uncertainty also compatible with an attractive interaction. Lastly, assuming the coupling $g_{b_1\omega\pi}$ extracted from the experimental width we estimate $m_{b_1}^{res}=1.414(36)(^{+0}_{-83})$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Digital carrier demodulator employing components working beyond normal limits

In a digital device, having an input comprised of a digital sample stream at a frequency F, a method is disclosed for employing a component designed to work at a frequency less than F. The method, in general, is comprised of the following steps: dividing the digital sample stream into odd and even digital samples streams each at a frequency of F/2; passing one of the digital sample streams through the component designed to work at a frequency less than F where the component responds only to the odd or even digital samples in one of the digital sample streams; delaying the other digital sample streams for the time it takes the digital sample stream to pass through the component; and adding the one digital sample stream after passing through the component with the other delayed digital sample streams. In the specific example, the component is a finite impulse response filter of the order ((N + 1)/2) and the delaying step comprised passing the other digital sample streams through a shift register for a time (in sampling periods) of ((N + 1)/2) + r, where r is a pipline delay through the finite impulse response filter.

Hurd, William J.↗

On-line calibration of high-response pressure transducers during jet-engine testing

Jet engine testing is reported concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero-shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique no leak matrix valve design is used in the reference pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

On-line calibration of high-response pressure transducers during jet-engine testing

Current jet engine testing is concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique 'no leak' matrix valve design is used in the reference-pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

Global optimization of data quality checks on 2-D and 3-D networks of GPR cross-well tomographic data for automatic correction of unknown well deviations

Significant errors related to poor time zero estimation, well deviation or mislocation of the transmitter (TX) and receiver (RX) stations can render even the most sophisticated modeling and inversion routine useless. Previous examples of methods for the analysis and correction of data errors in geophysical tomography include the works of Maurer and Green (1997), Squires et al. (1992) and Peterson (2001). Here we follow the analysis and techniques of Peterson (2001) for data quality control and error correction. Through our data acquisition and quality control procedures we have very accurate control on the surface locations of wells, the travel distance of both the transmitter and receiver within the boreholes, and the change in apparent zero time. However, we often have poor control on well deviations, either because of economic constraints or the nature of the borehole itself prevented the acquisition of well deviation logs. Also, well deviation logs can sometimes have significant errors. Problems with borehole deviations can be diagnosed prior to inversion of travel-time tomography data sets by plotting the apparent velocity of a straight ray connecting a transmitter (TX) to a receiver (RX) against the take-off angle of the ray. Issues with the time-zero pick or distances between wells appear as symmetric smiles or frown in these QC plots. Well deviation or dipping-strong anisotropy will result in an asymmetric correlation between apparent velocity and take-off angle (Figure 1-B). In addition, when a network of interconnected GPR tomography data is available, one has the additional quality constraint of insuring that there is continuity in velocity between immediately adjacent tomograms. A sudden shift in the mean velocity indicates that either position deviations are present or there is a shift in the pick times. Small errors in well geometry may be effectively treated during inversion by including weighting, or relaxation, parameters into the inversion (e.g. Bautu et al., 2006). In the technique of algebraic reconstruction tomography (ART), which is used herein for the travel time inversion (Peterson et al., 1985), a small relaxation parameter will smooth imaging artifacts caused by data errors at the expense of resolution and contrast (Figure 2). However, large data errors such as unaccounted well deviations cannot be adequately suppressed through inversion weighting schemes. Previously, problems with tomograms were treated manually. However, in large data sets and/or networks of data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Mislocation of the transmitter and receiver stations of GPR cross-well tomography data sets can lead to serious imaging artifacts if not accounted for prior to inversion. Previously, problems with tomograms have been treated manually prior to inversion. In large data sets and/or networks of tomographic data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Our approach is to use cross-well data quality checks and a simplified model of borehole deviation with particle swarm optimization (PSO) to automatically correct for source and receiver locations prior to tomographic inversion. We present a simple model of well deviation, which is designed to minimize potential corruption of actual data trends. We also provide quantitative quality control measures based on minimizing correlations between take-off angle and apparent velocity, and a quality check on the continuity of velocity between adjacent wells. This methodology is shown to be accurate and robust for simple 2-D synthetic test cases. Plus, we demonstrate the method on actual field data where it is compared to deviation logs. This study shows the promise for automatic correction of well deviations in GPR tomographic data. Analysis of synthetic data shows that very precise estimates of well deviation can be made for small deviations, even in the presence of static data errors. However, the analysis of the synthetic data and the application of the method to a large network of field data show that the technique is sensitive to data errors varying between neighboring tomograms.

54 ENVIRONMENTAL SCIENCES↗

THE TYPE II SUPERNOVA RATE IN z {approx} 0.1 GALAXY CLUSTERS FROM THE MULTI-EPOCH NEARBY CLUSTER SURVEY

We present seven spectroscopically confirmed Type II cluster supernovae (SNe II) discovered in the Multi-Epoch Nearby Cluster Survey, a supernova survey targeting 57 low-redshift 0.05 < z < 0.15 galaxy clusters with the Canada-France-Hawaii Telescope. We find the rate of Type II supernovae within R{sub 200} of z {approx} 0.1 galaxy clusters to be 0.026{sup +0.085}{sub -0.018}(stat){sup +0.003}{sub -0.001}(sys) SNuM. Surprisingly, one SN II is in a red-sequence host galaxy that shows no clear evidence of recent star formation (SF). This is unambiguous evidence in support of ongoing, low-level SF in at least some cluster elliptical galaxies, and illustrates that galaxies that appear to be quiescent cannot be assumed to host only Type Ia SNe. Based on this single SN II we make the first measurement of the SN II rate in red-sequence galaxies, and find it to be 0.007{sup +0.014}{sub -0.007}(stat){sup +0.009}{sub -0.001}(sys) SNuM. We also make the first derivation of cluster specific star formation rates (sSFR) from cluster SN II rates. We find that for all galaxy types the sSFR is 5.1{sup +15.8}{sub -3.1}(stat) {+-} 0.9(sys) M{sub Sun} yr{sup -1} (10{sup 12} M{sub Sun }){sup -1}, and for red-sequence galaxies only it is 2.0{sup +4.2}{sub -0.9}(stat) {+-} 0.4(sys) M{sub Sun} yr{sup -1} (10{sup 12} M{sub Sun }){sup -1}. These values agree with SFRs measured from infrared and ultraviolet photometry, and H{alpha} emission from optical spectroscopy. Additionally, we use the SFR derived from our SNII rate to show that although a small fraction of cluster Type Ia SNe may originate in the young stellar population and experience a short delay time, these results do not preclude the use of cluster SN Ia rates to derive the late-time delay time distribution for SNe Ia.

79 ASTRONOMY AND ASTROPHYSICS↗

Arsenic induces structural and compositional colonic microbiome change and promotes host nitrogen and amino acid metabolism

Chronic exposure to arsenic in drinking water causes cancer and non-cancer diseases. However, mechanisms for chronic arsenic-induced pathogenesis, especially in response to lower exposure levels, are unclear. In addition, the importance of health impacts from xeniobiotic-promoted microbiome changes is just being realized and effects of arsenic on the microbiome with relation to disease promotion are unknown. To investigate impact of arsenic exposure on both microbiome and host metabolism, the stucture and composition of colonic microbiota, their metabolic phenotype, and host tissue and plasma metabolite levels were compared in mice exposed for 2, 5, or 10 weeks to 0, 10 (low) or 250 (high) ppb arsenite (As(III)). Genotyping of colonic bacteria revealed time and arsenic concentration dependent shifts in community composition, particularly the Bacteroidetes and Firmicutes, relative to those seen in the time-matched controls. Arsenic-induced erosion of bacterial biofilms adjacent to the mucosal lining and changes in the diversity and abundance of morphologically distinct species indicated changes in microbial community structure. Bacterical spores increased in abundance and intracellular inclusions decreased with high dose arsenic. Interestingly, expression of arsenate reductase (arsA) and the As(III) exporter arsB, remained unchanged, while the dissimilatory nitrite reductase (nrfA) gene expression increased. In keeping with the change in nitrogen metabolism, colonic and liver nitrite and nitrate levels and ratios changed with time. In addition, there was a concomitant increase in pathogenic arginine metabolites in the mouse circulation. These data suggest that arsenic exposure impacts the microbiome and microbiome/host nitrogen metabolism to support disease enhancing pathogenic phenotypes. - Highlights: • Arsenic exposure induces changes in host and host nitrogen metabolism that cause progresive change in the microbiome. • A polyphasic approach reveals changes in microbial community structure, composition and nitrite reductase expression. • The profile of nitrogen and nitroamino acid change caused by arsenic may relect increased risk of cardiovascular pathogenesis.

60 APPLIED LIFE SCIENCES↗

Noninvasive analysis of human neck muscle function

STUDY DESIGN. Muscle use evoked by exercise was determined by quantifying shifts in signal relaxation times of T2-weighted magnetic resonance images. Images were collected at rest and after exercise at each of two intensities (moderate and intense) for each of four head movements: 1) extension, 2) flexion, 3) rotation, and 4) lateral flexion. OBJECTIVE. This study examined the intensity and pattern of neck muscle use evoked by various movements of the head. The results will help elucidate the pathophysiology, and thus methods for treating disorders of the cervical musculoskeletal system. SUMMARY OF BACKGROUND DATA. Exercise-induced contrast shifts in T2 has been shown to indicate muscle use during the activity. The noninvasive nature of magnetic resonance imaging appears to make it an ideal approach for studying the function of the complex neuromuscular system of the neck. METHODS. The extent of T2 increase was examined to gauge how intensely nine different neck muscles or muscle pairs were used in seven subjects. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation was assessed to infer the pattern of use among and within individual neck muscles or muscle pairs. RESULTS. Signal relaxation increased with exercise intensity for each head movement. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation also increased with exercise load. Neck muscles or muscle pairs extensively used to perform each head movement were: extension--semispinalis capitis and cervicis and splenius capitis; flexion--sternocleidomastoid and longus capitis and colli; rotation--splenius capitis, levator scapulae, scalenus, semispinalis capitis ipsilateral to the rotation, and sternocleidomastoid contralateral; and lateral flexion--sternocleidomastoid CONCLUSION. The results of this study, in part, agree with the purported functions of neck muscles derived from anatomic location. This also was true for the few selected muscles that have been examined in human electromyographic studies. Neck muscle function and morphology can be studied at a detailed level using exercise-induced shifts in magnetic resonance images.

NASA Program Space Physiology and Countermeasures↗