Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Treatment planning for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Connection Between Sampling Problems in Bayesian Inference and Statistical Mechanics

The Bayesian and statistical mechanical communities often share the same objective in their work - estimating and integrating probability distribution functions (pdfs) describing stochastic systems, models or processes. Frequently, these pdfs are complex functions of random variables exhibiting multiple, well separated local minima. Conventional strategies for sampling such pdfs are inefficient, sometimes leading to an apparent non-ergodic behavior. Several recently developed techniques for handling this problem have been successfully applied in statistical mechanics. In the multicanonical and Wang-Landau Monte Carlo (MC) methods, the correct pdfs are recovered from uniform sampling of the parameter space by iteratively establishing proper weighting factors connecting these distributions. Trivial generalizations allow for sampling from any chosen pdf. The closely related transition matrix method relies on estimating transition probabilities between different states. All these methods proved to generate estimates of pdfs with high statistical accuracy. In another MC technique, parallel tempering, several random walks, each corresponding to a different value of a parameter (e.g. "temperature"), are generated and occasionally exchanged using the Metropolis criterion. This method can be considered as a statistically correct version of simulated annealing. An alternative approach is to represent the set of independent variables as a Hamiltonian system. Considerab!e progress has been made in understanding how to ensure that the system obeys the equipartition theorem or, equivalently, that coupling between the variables is correctly described. Then a host of techniques developed for dynamical systems can be used. Among them, probably the most powerful is the Adaptive Biasing Force method, in which thermodynamic integration and biased sampling are combined to yield very efficient estimates of pdfs. The third class of methods deals with transitions between states described by rate constants. These problems are isomorphic with chemical kinetics problems. Recently, several efficient techniques for this purpose have been developed based on the approach originally proposed by Gillespie. Although the utility of the techniques mentioned above for Bayesian problems has not been determined, further research along these lines is warranted

Pohorille, Andrew↗

SU-D-12A-05: Iterative Reconstruction Techniques to Enable Intrinsic Respiratory Gated CT in Mice

Purpose: Longitudinal studies of lung function in mice need the ability to image different phases of ventilation in free-breathing mice using retrospective gating. However, retrospective gating often produces under-sampled and uneven angular samples, resulting in severe reconstruction artifacts when using traditional FDK based reconstruction algorithms. We wanted to demonstrate the utility of iterative reconstruction method to enable intrinsic respiratory gating in small-animal CT. Methods: Free-breathing mice were imaged using a Siemens Inveon PET/micro-CT system. Evenly distributed projection images were acquired at 360 angles. Retrospective respiratory gating was performed using an intrinsic marker based on the average intensity in a region covering the diaphragm. Projections were classified into 4 and 6 phases (finer temporal resolution) resulting in 138 and 67 projections respectively. Reconstruction was carried out using 3 Methods: conventional FDK, iterative penalized least-square (PWLS) with total variation (TV), and PWLS with edge-preserving penalty. The performance of the methods was compared using contrast-to-noise (CNR) in a region of interest (ROI). Line profile through a specific region was plotted to evaluate the preserving of edges. Results: In both the cases with 4 and 6 phases, inadequate and non-uniform angular sampling results in artifacts using conventional FDK. However, such artifacts are minimized using both the iterative methods. Using both 4 and 6 phases, the iterative techniques outperformed FDK in terms of CNR and maintaining sharp edges. This is further evidenced especially with increased artifacts using FDK for 6 phases. Conclusion: This work indicates fewer artifacts and better image details can be achieved with iterative reconstruction methods in non-uniform under-sampled reconstruction. Using iterative methods can enable free-breathing intrinsic respiratory gating in small-animal CT. Further studies are needed to compare the computational complexity for large datasets.

60 APPLIED LIFE SCIENCES↗

Evaluation of a Multizone Impedance Eduction Method

A computational study is used to evaluate the PyCHE impedance eduction method developed at the NASA Langley Research Center. This method combines an aeroacoustic duct propagation code based on numerical solution to the convected Helmholtz equation with a global optimizer that uses the Differential Evolution algorithm. The efficacy of this method is evaluated with acoustic pressure data simulated to represent that measured with one-zone, two-zone, and three-zone liners mounted in the NASA Langley Grazing Flow Impedance Tube. The PyCHE method has a normalized impedance error of approximately 0.2 for (uniform) one-zone liners with a length of at least 5”, and produces quite reasonable results for liners as short as 2”. Whereas the impedance of the liner has an effect on eduction accuracy, the amount of attenuation is shown to be the dominant parameter. Similar results are observed for two-zone liners, for which the impedance of each zone is unique. The two-zone results also indicate it is more difficult to accurately educe resistance than reactance, and a zone length of at least 6” (slightly longer than for uniform liners) is needed to limit the normalized error to 0.2. The PyCHE method is also demonstrated to successfully educe the impedances for each zone of a three-zone liner. These results are sufficiently encouraging to warrant the continued usage of the PyCHE impedance eduction method for single and multizone liners.

Jones, M. G.↗

Noise power spectrum of the fixed pattern noise in digital radiography detectors

Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain NNPS curves of the indirect detectors, we could analyze the scintillator properties depending on the techniques for the scintillator surface processing. Conclusions: A robust measuring method for the NNPS of the fixed pattern noise of a radiography detector is proposed in this paper. The method can measure a stable gain NNPS curve, even though the fixed pattern noise level is quite low. From the measured gain NNPS curves, we can compare and analyze the detector properties in terms of producing the fixed pattern noise.

60 APPLIED LIFE SCIENCES↗

Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered (up to 30 Gy). Gafchromic{sup TM} EBT2 and EBT3 films may be considered the dosimeter of choice, and the authors here provide some additional data about uniformity correction for this new generation of radiochromic films.Methods: A new analysis method using blue channel for marker dye correction was proposed for uniformity correction both for EBT2 and EBT3 films. Symmetry, flatness, and field-width of a reference field were analyzed to provide an evaluation in a high-spatial resolution of the film uniformity for EBT3. Absolute doses were compared with thermoluminescent dosimeters (TLD) as baseline. VMAT plans with multiple noncoplanar arcs were generated with a treatment planning system on a selected pool of eleven patients with cranial lesions and then recalculated on a water-equivalent plastic phantom by Monte Carlo algorithm for patient-specific QA. 2D quantitative dose comparison parameters were calculated, for the computed and measured dose distributions, and tested for statistically significant differences.Results: Sensitometric curves showed a different behavior above dose of 5 Gy for EBT2 and EBT3 films; with the use of inhouse marker-dye correction method, the authors obtained values of 2.5% for flatness, 1.5% of symmetry, and a field width of 4.8 cm for a 5 × 5 cm{sup 2} reference field. Compared with TLD and selecting a 5% dose tolerance, the percentage of points with ICRU index below 1 was 100% for EBT2 and 83% for EBT3. Patients analysis revealed statistically significant differences (p < 0.05) between EBT2 and EBT3 in the percentage of points with gamma values <1 (p= 0.009 and p= 0.016); the percent difference as well as the mean difference between calculated and measured isodoses (20% and 80%) were found not to be significant (p= 0.074, p= 0.185, and p= 0.57).Conclusions: Excellent performances in terms of dose homogeneity were obtained using a new blue channel method for marker-dye correction on both EBT2 and EBT3 Gafchromic{sup TM} films. In comparison with TLD, the passing rates for the EBT2 film were higher than for EBT3; a good agreement with estimated data by Monte Carlo algorithm was found for both films, with some statistically significant differences again in favor of EBT2. These results suggest that the use of Gafchromic{sup TM} EBT2 and EBT3 films is appropriate for dose verification measurements in VMAT stereotactic radiosurgery; taking into account the uncertainty associated with Gafchromic film dosimetry, the use of adequate action levels is strongly advised, in particular, for EBT3.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the Crab Pulsar's Timing Noise

We present a power spectral analysis of the Crab pulsar's timing noise, mainly using radio measurements from Jodrell Bank taken over the period 1982-1989, an interval bounded by sparse data sampling and a large glitch. The power spectral analysis is complicated by nonuniform data sampling and the presence of a steep red power spectrum that can distort power spectra measurement by causing severe power 'leakage'. We develop a simple windowing method for computing red noise power spectra of uniformly sampled data sets and test it on Monte Carlo generated sample realizations of red power-law noise. We generalize time-domain methods of generating power-law red noise with even integer spectral indices to the case of noninteger spectral indices. The Jodrell Bank pulse phase residuals are dense and smooth enough that an interpolation onto a uniform time series is possible. A windowed power spectrum is computed revealing a periodic or nearly periodic component with a period of 568 +/- 10 days and a l/f(exp 3) power-law noise component in pulse phase with a noise strength S(sub infinity)=(1.24 +/- 0.067) x 10(exp 16) cycles(exp 2)/sec(exp 2) over the analysis frequency range f=0.003- 0.1 cycles/day. This result deviates from past analyses which characterized the pulse phase timing residuals as either l/f(sub 4) power-law noise or a quasiperiodic process. The analysis was checked using the Deeter polynomial method of power spectrum estimation that was developed for the case of nonuniform sampling, but has lower spectral resolution. The timing noise is consistent with a torque noise spectrum rising with analysis frequency as f implying blue torque noise, a result not predicted by current models of pulsar timing noise. If the periodic or nearly periodic component is due to a binary companion, we find a mass function f(M) = (6.8 +/- 2.4) x 10(exp -16) solar mass and a companion mass, M(sub c) is greater than or equal to 3.2 solar mass assuming a Crab pulsar mass of 1.4 solar mass.

Scott, D. M.↗

The Numerical Analysis of a Turbulent Compressible Jet

A numerical method to simulate high Reynolds number jet flows was formulated and applied to gain a better understanding of the flow physics. Large-eddy simulation was chosen as the most promising approach to model the turbulent structures due to its compromise between accuracy and computational expense. The filtered Navier-Stokes equations were developed including a total energy form of the energy equation. Subgrid scale models for the momentum and energy equations were adapted from compressible forms of Smagorinsky's original model. The effect of using disparate temporal and spatial accuracy in a numerical scheme was discovered through one-dimensional model problems and a new uniformly fourth-order accurate numerical method was developed. Results from two- and three-dimensional validation exercises show that the code accurately reproduces both viscous and inviscid flows. Numerous axisymmetric jet simulations were performed to investigate the effect of grid resolution, numerical scheme, exit boundary conditions and subgrid scale modeling on the solution and the results were used to guide the three-dimensional calculations. Three-dimensional calculations of a Mach 1.4 jet showed that this LES simulation accurately captures the physics of the turbulent flow. The agreement with experimental data was relatively good and is much better than results in the current literature. Turbulent intensities indicate that the turbulent structures at this level of modeling are not isotropic and this information could lend itself to the development of improved subgrid scale models for LES and turbulence models for RANS simulations. A two point correlation technique was used to quantify the turbulent structures. Two point space correlations were used to obtain a measure of the integral length scale, which proved to be approximately 1/2 D(sub j). Two point space-time correlations were used to obtain the convection velocity for the turbulent structures. This velocity ranged from 0.57 to 0.71 U(sub j).

DeBonis, James R.↗

A Method for the Prediction of Late Organ-at-Risk Toxicity After Radiotherapy of the Prostate Using Equivalent Uniform Dose

Purpose: To evaluate the predictive value of equivalent uniform doses (EUD) for late bladder and rectal toxicity after high-dose three-dimensional conformal radiation therapy (3D-CRT) to the prostate. Materials and Methods: Using the method developed by Kutcher et al., EUDs for whole bladder and rectum were calculated from the dose-volume histograms of 180 patients with localized prostate cancer treated to 70-74 Gy with 3D-CRT. Late complications were recorded using the Radiation Therapy Oncology Group scale, correlated against EUD and known physical predictive indicators. Results: EUD is an independent prognostic factor for Grade 2+ long-term rectal and bladder toxicity after radiation treatment to the prostate. Patients receiving an EUD >63.1 Gy to the rectum have a statistically significant (10% vs. 30%; p = 0.002) higher risk of developing Grade 2+ late complications. Patients receiving an EUD >53.4 Gy to the bladder have a statistically significant (10% vs. 33%; p = 0.001) higher risk of developing Grade 2+ late complications. Conclusions: It has been demonstrated that EUD is a strong independent predictive factor for Grade 2+ late complications after 3D-CRT to the prostate. Threshold values have been demonstrated for both bladder and rectum, above which there is a clinically significant increased risk of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Velocity Impact Performance of a Dual Layer Thermal Protection System for the Mars Sample Return Earth Entry Vehicle

The Mars Sample Return (MSR) Earth Entry Vehicle (EEV) is currently planned on being released from its Micro-Meteorite/Orbital Debri (MM/OD) shielding housing about two days before the Earth entry phase. This leaves the EEV exposed to incoming MM/OD impacts, potentially damaging the heat shield and compromising its Entry, Decent, and Landing (EDL) integrity. Currently, two materials are proposed to comprise the MSR-EEV heat shield, a dual layer material Heat-shield for Extreme Entry Environment Technology (HEEET) and Phenolic Impregnated Carbon Ablator (PICA). PICA has been well characterized for OD class impacts, ~7km/s high mass impacts, from previous testing done in the Orion program, but hasn't under-gone extensive MM impact testing. HEEET is a rela-tively new material with minimal prior testing in re-gards to High Velocity Impacts (HVI). In order to in-form selectability of a material, it is crucial to under-stand the material performance when faced with an HVI, directly affecting mission success probability.The current measure of a Thermal Protection Sys-tem's (TPS) performance against an HVI is evaluating a thermally sized material against its derived Balistic Limit Equation (BLE). A BLE is generated empirically from multiple shots of HVI testing, and is used as a first order method in evaluating TPS's performance against the expected MM/OD environment. This method has proved useful for previous uniform densi-ty TPS materials, but has never been validated against a dual layer recession material such as HEEET. Testing in the MSR program for FY19 has a re-quirement to assess the effects of a dual layer TPS by testing various thicknesses of HEEET's Recession Layer, seen in Figure 1. From this data, BLE's will be derived for the individual thickness ratio samples, as well as the material as a whole to evaluate if a heritage form of the BLE can capture the complex physics associated with a dual layer system. Crater morpholo-gy will also be assessed with post-test Non-Destructive Evaluation (NDE) methods such as CT scanning to visualize if a BLE can well predict the associated pene-tration depths, since a BLE assumes full disinigration of the impacting particle and is generally only used to size a spherical crater ? disregarding any shrapenel effects from a high density impactor.To inform this analysis, expected MM environ-ments from the Meteoroid Engineering Model (MEM) and analytical equations for mass flux of incoming MM were evaluated against the notional MSR-EEV trajectory [1]. Using those dispersions, a monte-carlo was run to determine the most probable particle pa-rameters, as well as the riskiest in terms of full bondline penetration. From these probabilities, a test matrix was designed to test against bounding cases for the various parameters of the BLE: projectile density, projectile mass, projectile velocity, and the impact angle.This presentation will discuss the performance of the dual layer TPS material HEEET against a wide range of impact kinetic energies and densitites, as well as the comparison of HEEET to PICA in terms of MM/OD performance and selectability criteria.

Libben, B. J.↗

Americium Transmutation Feasibility When Used as Burnable Absorbers - 12392

The use of plutonium in Mixed Oxide (MOX) fuel in traditional Pressurized Water Reactor (PWR) assemblies leads to greater americium production which is not addressed in MOX recycling. The transuranic nuclides (TRU) contribute the most to the radiotoxicity of nuclear waste and a reduction of the TRU stockpile would greatly reduce the overall radiotoxicity of what must be managed. Am-241 is a TRU of particular concern because it is the dominant contributor of total radiotoxicity for the first 1000 years in a repository. This research explored the feasibility of transmuting Am-241 by using varying amounts in MOX rods being used in place of burnable absorbers and evaluated with respect to the impact on incineration and transmutation of transuranics in MOX fuel as well as the impact on safety. This research concludes that the addition of americium to a non-uniform fuel assembly is a viable method of transmuting Am-241, holding down excess reactivity in the core while serving as a burnable poison, as well as reducing the radiotoxicity of high level waste that must be managed. The use of Am/MOX hybrid fuel assemblies to transmute americium was researched using multiple computer codes. Am-241 was shown in this study to be able to hold down excess reactivity at the beginning of cycle and shape the power distribution in the core with assemblies of varying americium content loaded in a pattern similar to the traditional use of assemblies with varying amounts of burnable absorbers. The feasibility, safety, and utility of using americium to create an Am/MOX hybrid non-uniform core were also evaluated. The core remained critical to a burnup of 22,000 MWD/MTM. The power coefficient of reactivity as well as the temperature and power defects were sufficiently negative to provide a prompt feedback mechanism in case of a transient and prevent a power excursion, thus ensuring inherent safety and protection of the core. As shown here as well as many other studies, this non-uniform assembly type successfully addresses the concerns of reduced control rod worth within advanced MOX assemblies because the Am/MOX hybrid fuel rods are on the periphery of the assembly. The radiotoxicity of the high level waste that must be managed from a single use of an Am/MOX hybrid batch is reduced for the first 1000 years in comparison to a regular UO{sub 2} batch. However, there is no heat-load advantage without multi-recycling the Am/MOX hybrid assemblies. As shown through numerous studies, the heterogeneous assembly model used as the basis for this research is capable of multiple recycles while still maintaining negative temperature and power coefficients of reactivity. Multi-recycling would provide an even greater reduction to the radiotoxicity of the high level waste as well as provide a heat-load advantage compared to a once through UO{sub 2} fuel cycle. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser deposition of large-area thin films

A new method for fabricating large-area thin films of uniform thickness on a rotating substrate is proposed. Its distinctive features are (i) the presence of a diaphragm, partially transmitting the evaporated material, between the target and substrate and (ii) the translatory motion of the rotating substrate with respect to the target at a certain velocity. The method proposed makes it possible to obtain thin films of uniform thickness on substrates with sizes limited by only the deposition chamber size. The method is experimentally verified by depositing thin CuO films on silicon substrates placed over the radius of a disk 300 mm in diameter. The deviation of the film thickness from the average value does not exceed {+-}3% throughout the entire radius, which confirms good prospects of this method for microelectronics, optical industry, and other modern technologies. (laser technology)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an Innovative High-Thermal Conductivity UO2 Ceramic Composites Fuel Pellets with Carbon Nano-Tubes Using Spark Plasma Sintering

Uranium dioxide (UO2) is the most common fuel material in commercial nuclear power reactors. Despite its numerous advantages such as high melting point, good high-temperature stability, good chemical compatibility with cladding and coolant, and resistance to radiation, it suffers from low thermal conductivity that can result in large temperature gradients within the UO2 fuel pellet, causing it to crack and release fission gases. Thermal swelling of the pellets also limits the lifetime of UO2 fuel in the reactor. To mitigate these problems, we propose to develop novel UO2 fuel with uniformly distributed carbon nanotubes (CNTs) that can provide high-conductivity thermal pathways and can eliminate fuel cracking and fission gas release due to high temperatures. CNTs have been investigated extensively for the past decade to explore their unique physical properties and many potential applications. CNTs have high thermal conductivity (6600 W/mK for an individual single- walled CNT and >3000 W/mK for an individual multi-walled CNT) and high temperature stability up to 2800°C in vacuum and about 750°C in air. These properties make them attractive candidates in preparing nano-composites with new functional properties. The objective of the proposed research is to develop high thermal conductivity of UO2–CNT composites without affecting the neutronic property of UO2 significantly. The concept of this goal is to utilize a rapid sintering method (5–15 min) called spark plasma sintering (SPS) in which a mixture of CNTs and UO2 powder are used to make composites with different volume fractions of CNTs. Incorporation of these nanoscale materials plays a fundamentally critical role in controlling the performance and stability of UO2 fuel. We will use a novel in situ growth process to grow CNTs on UO2 particles for rapid sintering and develop UO2-CNT composites. This method is expected to provide a uniform distribution of CNTs at various volume fractions so that a high thermally conductive UO2-CNT composite is obtained with a minimal volume fraction of CNTs. The mixtures are sintered in the SPS facility at a range of temperatures, pressures, and time durations so as to identify the optimal processing conditions to obtain the desired microstructure of sintered UO2-CNT pellets. The second objective of the proposed work is to identify the optimal volume fraction of CNTs in the microstructure of the composites that provides the desired high thermal conductivity yet retaining the mechanical strength required for efficient function as a reactor fuel. We will systematically study the resulting microstructure (grain size, porosity, distribution of CNTs, etc.) obtained at various SPS processing conditions using optical microscopy, scanning electron microscopy (SEM), and transmission electron microscope (TEM). We will conduct indentation hardness measurements and uniaxial strength measurements as a function of volume fraction of CNTs to determine the mechanical strength and compare them to the properties of UO2. The fracture surfaces will be studied to determine the fracture characteristics that may relate to the observed cracking during service. Finally, we will perform thermal conductivity measurements on all the composites up to 1000° C. This study will relate the microstructure, mechanical properties, and thermal properties at various volume fractions of CNTs. The overall intent is to identify optimal processing conditions that will provide a well-consolidated compact with optimal microstructure and thermo-mechanical properties. The deliverables include: (1) fully characterized UO2-CNT composite with optimal CNT volume fraction and high thermal conductivity and (2) processing conditions for production of UO2-CNT composite pellets using SPS method.

Subhash, Ghatu↗

Application of microscopy technology in thermo-catalytic methane decomposition to hydrogen

Hydrogen production from the direct thermo-catalytic decomposition of methane is a promising alternative for clean fuel production because it produces pure hydrogen without any CO{sub x} emissions. However, thermal decomposition of methane can hardly be of any practical and empirical interest in the industry unless highly efficient and effective catalysts, in terms of both specific activity and operational lifetime have been developed. In this work, bimetallic Ni-Pd on gamma alumina support have been developed for methane cracking process by using co-precipitation and incipient wetness impregnation method. The calcined catalysts were characterized to determine their morphologies and physico-chemical properties by using Brunauer-Emmett-Teller method, Field Emission Scanning Electron Microscopy, Energy-dispersive X-ray spectroscopy and Thermogravimetric Analysis. The results suggested that that the catalyst which is prepared by the co-precipitation method exhibits homogeneous morphology, higher surface area, have uniform nickel and palladium dispersion and higher thermal stability as compared to the catalyst which is prepared by wet impregnation method. This characteristics are significant to avoid deactivation of the catalysts due to sintering and carbon deposition during methane cracking process.

36 MATERIALS SCIENCE↗

Modification of the Langmuir–Schaefer method for fabrication of ordered protein films

A modification of the Langmuir–Schaefer method for the fabrication of high-quality protein films on a solid substrate was proposed and applied to lysozyme. The procedure relies on the use of a pre-prepared protein solution, the parameters of which correspond to crystallization conditions. A lysozyme Langmuir monolayer was shown to be formed with the involvement of complexes, namely, dimers and octamers of protein molecules that are present in such protein solutions. These complexes apparently retain the structure after spreading a protein solution onto an aqueous subphase in a Langmuir trough. The thickness of the film after the transfer of the monolayer, which was formed by the proposed procedure, onto a solid substrate corresponds to the diameter of the octamer and this film is dense, continuous, and uniform, as was demonstrated by several methods: X-ray reflectivity, total external reflection X-ray standing wave, and atomic force microscopy. A layer of chloride ions that formed under the Langmuir monolayer was found at the air–protein film interface. This fact confirms an important role of the precipitating agent (chloride ions) in all steps of the formation of lysozyme films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A biaxial method for inplane shear testing

A biaxial method for performing inplane shear tests of materials using a shear frame is described. Aluminum plate and sandwich specimens were used to characterize the uniformity of shear strain imparted by the biaxial method of loading as opposed to the uniaxial method. The inplane stiffening effect of aluminum honeycomb core was determined. Test results for (+ or - 45) graphite-epoxy laminate are presented. Some theoretical considerations of subjecting an anisotropic material to a uniform shear deformation are discussed.

Bush, H. G.↗

Assessing task performance in FFDM, DBT, and synthetic mammography using uniform and anthropomorphic physical phantoms

Purpose The purpose of this study is to quantify the differences in detectability between full field digital mammography (FFDM), digital breast tomosynthesis (DBT), and synthetic mammography (SM) for challenging, low contrast signals, in the context of both a uniform and an anthropomorphic, textured phantom. Methods Images of the phantoms were acquired using a Hologic Selenia Dimensions system. Images were taken at 50%, 100%, and 200% of the dose delivered under automatic exposure control (AEC). Low‐contrast disks, created using an inkjet printer with iodine‐doped ink, were inserted into the phantom. The disks varied in diameter from 210 to 630 μ m, and in local contrast from 1.1% to 2.8% in regular increments. Human observers located the disks in a 4 alternative forced choice experiment. Proportion correct (PC) was computed as the number of correct localizations out of the total number of tries. Results Overall, scores from FFDM and DBT were consistently greater than scores from SM. At an exposure corresponding to the AEC setting, mean PC scores for the largest disks with the uniform phantom were 0.80 for FFDM, 0.83 for DBT, and 0.66 for SM, with the same rank ordering at other doses. Scores were similar but lower for the nonuniform background. At an exposure twice the AEC setting, however, the difference between uniform and nonuniform scores was most pronounced for DBT alone. Differences between scores for FFDM and SM were statistically significant, while those between FFDM and DBT were not. Scores were used to compute the minimum contrast level needed to reach 62.5% detection rate. The minimum contrast for SM was 36%–81% higher compared to FFDM or DBT, in either background. Conclusions This study shows that an anthropomorphic phantom and lesions inserts may be used to conduct a reader study. Detectability was significantly lower for synthetic mammography than for FFDM or DBT, for all conditions. Additionally, observer performance was consistently lower for the anthropomorphic phantom, indicating the greater challenge due to anatomical background. Because of this, it may be important to use realistic phantoms in observer studies in order to draw conclusions that are more clinically relevant.

Ikejimba, Lynda C.↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗