Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Improved smoke generator for low-speed wind tunnels

Device incorporates kerosene vaporization concept by electrically heating tubes that carry kerosene down the probe, smoke is emitted from orifices at probe's end. Neither the low concentration of kerosene vapor nor the 50 Vdc power supply constitutes a safety hazard.

Turner, T. R.↗

Space shuttle: Heat transfer rate measurements on Convair booster (B-15B-2) at nominal Mach number of 8

Plotted and tabulated data on heat transfer from a thin-skin thermocouple are presented. The data is representative of the reentry event of the booster alone configuration. The data were generated during wind tunnel tests of the B-15B-2 delta wing booster at Mach 8. Thermocouple measurements are reduced to heat transfer coefficient ratio and the data are presented as plotted variations versus longitudinal, lateral, and vertical local model positions.

Warmbrod, J. D.↗

A procedure for predicting internal and external noise fields of blowdown wind tunnels

The noise generated during the operation of large blowdown wind tunnels is considered. Noise calculation procedures are given to predict the test-section overall and spectrum level noise caused by both the tunnel burner and turbulent boundary layer. External tunnel noise levels due to the tunnel burner and circular jet exhaust flow are also calculated along with their respective cut-off frequency and spectrum peaks. The predicted values are compared with measured data, and the ability of the prediction procedure to estimate blowdown-wind-tunnel noise levels is shown.

Hosier, R. N.↗

Dissipation of electric fields in the ionosphere

The heating and movement of the upper atmosphere at ionospheric levels in response to electric currents are discussed. Joule dissipation, generation of winds, and pressure gradients are significant factors in the energetics of the ionospheric electric currents flowing during magnetic storms and also of the Sq current system.

Cole, K. D.↗

Development of performance criteria for advanced Viking seismic experiments

The characteristics and requirements of the seismic instrument for mapping the internal structure of the planet Mars are briefly described. The types of signals expected to exist are microseismic background generated by wind and pressure variations and thermal effects, disturbances of or in the landed vehicle, signals caused by faulting and volcanic activity, and signals due to meteoritic impacts. The advanced instrument package should include a short-period vertical component system, a long-period or wide-band 3-component system, a high frequency vertical component system, and a system for detection and rejection of lander noises. The Viking '75, Surveyor, and Apollo systems are briefly described as potential instruments to be considered for modification. Data processing and control systems are also summarized.

Source record↗

Mechanisms for Mars dust storms.

Characteristics of the Mars global dust storm are reviewed. At the Mariner 9 encounter, the dust consisted of highly absorbing particles distributed rather uniformly up to great height (about 50 km). These observations together with temperature distributions inferred from the Mariner 9 IRIS by Hanel et al. (1972) are used to estimate global wind systems during the dust storm. The global distribution and direction of light surface streaks indicate that the axisymmetric circulation was a dominant part of flow during the dust storm. The axisymmetric winds may become strong enough to raise dust over wide areas of Mars' tropics under unusual conditions: the incoming solar radiation must be near its seasonal maximum, the static stability must be low, and the atmosphere must be able to absorb and re-emit a sizeable fraction of the incoming radiation. Strong winds around the periphery of the retreating south polar cap would be driven by the temperature gradient at the cap edge and by the mass outflow due to subliming CO2. These polar winds could generate local dust storms, raising the general level of dustiness, and providing the conditions necessary for onset of a global dust storm.

Leovy, C. B.↗

Smith-Putnam wind turbine experiment

A brief outline of the many problems encountered during testing of a wind turbine generator prototype unit is given. Its feasibility was demonstrated by the generation of electricity in commercial quantities with delivery to a utility transmission network. The experiment was terminated after blade failure occurred.

Smith, B. E.↗

Wind power systems for individual applications

A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.

Clews, H. M.↗

NASTRAN use for cyclic response and fatigue analysis of wind turbing towers

A procedure is described which uses NASTRAN coupled with fatigue criteria via a postprocessor to determine the cyclic response and to assess the fatigue resistance (fatigue life) of wind turbine generator towers. The cyclic loads to which the tower may be subjected are entered either in a quasi-static approach though static load subcases (Rigid Format 1) or through the direct dynamic response (Rigid Format 9) features of NASTRAN. The fatigue criteria are applied to NASTRAN output data from either rigid format through an externally written user program embedded in a postprocessor.

Chamis, C. C.↗

Interactive image processing for meteorological applications at NASA/Goddard Space Flight Center

The paper reviews the development of the AOIPS (Atmospheric and Oceanographic Information Processing System) system for the interactive manipulation of meteorological satellite images. A block diagram of the system is presented; both software and hardware considerations are examined; and attention is given to the Image 100 processing system and to the interactive terminal. As a example the paper examines the functions of Metpak (the software package) which involve cloud tracking and wind vector generation.

Billingsley, J. B.↗

An operating 200-kW horizontal axis wind turbine

The Mod-OA wind turbine blades were rotated for the first time on November 30, 1977, establishing the Mod-OA as the first wind-driven generator in 35 years to be continually tied into an electrical power system which services a community. Tower-mounted equipment and blade structural design and fabrication are discussed.

Hunnicutt, C. L.↗

Fatigue impact on Mod-1 wind turbine design

Fatigue is a key consideration in the design of a long-life Wind Turbine Generator (WTG) system. This paper discusses the fatigue aspects of the large Mod-1 horizontal-axis WTG design starting with the characterization of the environment and proceeding through the design. Major sources of fatigue loading are discussed and methods of limiting fatigue loading are described. NASTRAN finite element models are used to determine dynamic loading and internal cyclic stresses. Recent developments in determining the allowable fatigue stress consistent with present construction codes are discussed relative to their application to WTG structural design.

Stahle, C. V., Jr.↗

The influence of the Martian polar caps on the diurnal tide

The large horizontal heating gradients that exist near the edge of the Martian polar caps during spring are shown to be capable of exciting large oscillations in the diurnal tide. To a lesser extent, the daily mass cycling between cap and atmosphere can also contribute. The calculations which demonstrate this are based on classical tidal theory as applied to the cylindrical coordinate system. This is done to facilitate the representation of the heating function. Results are presented for the horizontal surface winds only. They indicate a circulation at the cap edge somewhat analogous to the smaller scale terrestrial sea breeze. The amplitude of the zonal component is largest and is increased from 1 to 10 m/sec by the modeled influence of the polar cap. When coupled with the basic flow these cap-edge tides can produce strong surface winds during spring. Such a mechanism may contribute to the ability of the south polar cap winds to generate the local dust storms observed near the cap edge at this season.

Haberle, R. M.↗

System configuration improvement

Factors involved in the choice of the system configuration for the wind turbine generator are listed. It was found that choices among the many configuration options can be based strictly upon the resulting cost of energy results. Choices made on that basis also lead to reduced analytical complexity, less hardware complexity and reduced program risk. It was also found that many seemingly minor details turn out to have important impacts that are seen only after design, performance and cost-finding were thoroughly probed.

Doman, G. S.↗

Cost of energy evaluation

The estimated cost per kilowatt hour, the wind resources in the utilities service area, and the reliability of the units are considered in computing the cost of energy of the wind turbine generator system.

Hasbrouck, T. M.↗

MOD-2 wind turbine farm stability study

The dynamics of single and multiple 2.5 ME, Boeing MOD-2 wind turbine generators (WTGs) connected to utility power systems were investigated. The analysis was based on digital simulation. Both time response and frequency response methods were used. The dynamics of this type of WTG are characterized by two torsional modes, a low frequency 'shaft' mode below 1 Hz and an 'electrical' mode at 3-5 Hz. High turbine inertia and low torsional stiffness between turbine and generator are inherent features. Turbine control is based on electrical power, not turbine speed as in conventional utility turbine generators. Multi-machine dynamics differ very little from single machine dynamics.

Hinrichsen, E. N.↗